Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

URSI General Assembly and Scientific Symposium

Update on the development of cesium atomic fountain at NPL, India

Poonam Arora, Ashish Agarwal, Kavindra Pant, Suchi Yadav, Amitava Sen Gupta

Published Aug 1, 2011• 0 citations
Publisher

Abstract

National Physical Laboratory India (NPLI) has been developing a cesium atomic fountain primary frequency standard. We have succeeded in trapping about 107Cs atoms, cool them to about 5 μK by both magneto-optical trap (MOT) and polarization gradient cooling (PGC) and launch them up by moving molasses method. We have demonstrated the fountain action by launching the atoms up to 72.9 cm up and detection of the return signal by measuring the fluorescence. Work is underway to interrogate the launched atoms with microwaves and observe Ramsey fringes.

DOI
10.1109/ursigass.2011.6050322

Related papers

Characterization of cold atomic cloud in a magneto-optical trap

Poonam Arora, Swatilekha Chowdhury, Ashish Agarwal +2 more

The results of characterization of cold cloud of cesium (Cs) atoms trapped in a magneto-optical trap (MOT) have been presented. The MOT is a part of the Physics package of the Cs Fountain Clock being developed at National Physical Laboratory (NPL), India. The number of atoms, size and temperature of the cloud have been measured and calculated. It is also been investigated how the number of trapped atoms changes with the trapping laser’s beam intensity, detuning and magnetic-field gradient of the trap.

•Sep 1, 2011•0 citations

Article

Marie-Claude Gagné, J.-S. Boulanger, R J W Douglas

The accelerated development of laser methods for manipulating the internal state and motion of atoms, and the recent primary evaluation in France of a cesium frequency standard using cold atoms in an atomic fountain configuration, allow the frontiers of time metrology, accuracy, and stability to be pushed near parts in the 1016 level, a factor of 100 over the present primary laboratory clocks. These positive results revived the development of more accurate cesium atomic clocks, and the Institute of National Measurement Standards (INMS), of the National Research Council of Canada (NRC) is undertaking a cesium-fountain project aimed at reaching these new levels of accuracy and stability. This paper reviews its present status. To appreciate the considerable impact of cold atoms in time and frequency metrology, we begin by recalling the background principles of traditional cesium frequency standards, their typical performance and main limitations. After introducing the important theoretical results essential to understanding the techniques of laser cooling and magneto-optical trapping, we focus on describing the characterization and control of our magneto-optical trap (MOT) and report the parameters that allow us to fill the trap with a few million atoms in less than a second and cool them to a temperature lower than 5 muK using optical molasses. We will describe the specifics of our cesium-fountain prototype, which operates with a 2-dimensional moving molasses. This special configuration is applicable for multipulse operation of the fountain, which can greatly relax the local oscillator requirements for time keeping. Finally, progress toward our objective of launching cooled atoms, at a rate of one ensemble per second, at speeds of 7 m/s, for a fountain with an interrogation time of about 1 s, will be analysed.PACS Nos.: 06.20, 06.30, and 32.80P

Canadian Journal of Physics•Aug 1, 1998•0 citations

Cold atoms and cesium fountains at NRC

J.-S. Boulanger, Marie-Claude Gagné, R.J. Douglas

We present a progress report on laser-cooled cesium atoms at NRC, work which was started a few years ago in order to realize a cesium fountain frequency standard. We selected an acceleration with two-dimensional moving molasses, which can increase both the force and the interaction time by a factor of /spl radic/2 over the more common 1-D molasses scheme. This configuration also allows for trapping and cooling of atoms while previously launched atoms are still moving in the clock section of the system. We report measurements on the number of atoms, temperature, friction coefficient and spring constant of our magneto-optical trap and 1-D molasses for various conditions.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Dec 24, 2002•4 citations

Design and preliminary results of NIM cesium fountain primary frequency standard

Wang Liji, Wu Changhua, Huang Bingying +3 more

We have designed and constructed a cesium fountain as our new generation primary frequency standard. Serial performance measurements of components and assemblies are finished. A cold atomic cloud with diameter 1.5 mm and temperature /spl les/150 /spl mu/K has been observed in a magneto-optical trap set-up. It is used to obtain the optical molasses designed for the fountain clock.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jan 22, 2003•1 citation

Laser-cooled cesium atomic fountain experiment for atomic frequency standard

Jun Umezu, Yasusada Ohta, K. Hukuda +2 more

A cesium frequency standard based on the atomic fountain configuration has the potential of improving the accuracy of primary frequency standard. For the first step toward a realization of slow vertical atomic beam (that is an atomic fountain), we have succeeded to decelerate the horizontal cesium atomic beam by laser cooling with the Zeeman tuning method. Then those slowed atoms are confined with a magneto-optical trap by four laser beams in the tetrahedral configuration. By using these trapped atoms, one can launch them upward with the upstream laser pulses.>

Conference proceedings - IEEE Instrumentation/Measurement Technology Conference•Dec 17, 2002•0 citations

Study of a bright, slow, and cold cesium source for a continuous beam frequency standard

P. Berthoud, E. Fretel, P. Thomann

To achieve a primary frequency standard based on a continuous fountain of laser cooled cesium atoms, we report on the production of a bright, slow and cold continuous atomic beam. Atoms are cooled from a thermal vapor in a 45/spl deg/ laser geometry and launched directly from the optical molasses by the moving molasses technique. The effects of the source fluorescence on the continuous beam (average velocity, temperature and flux) have been observed, and ways to optimize simultaneously the atomic capture and the continuous beam are presented. Flux measurements rise to 2/spl times/10/sup 8/ at/s from a 2D magneto-optical trap at 7 m/s. The initial velocity is easily tunable from 1 to 10 m/s. If the longitudinal temperature is about 70 /spl mu/K, additional transverse cooling even reduces the transverse temperature in one dimension below 30 /spl mu/K. By extrapolating the obtained atomic flux to the continuous fountain under construction, we expect a short-term stability of 7/spl times/10/sup -14//spl tau//sup -1/2/. Other applications of continuous beams of cold atoms are suggested.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jan 22, 2003•2 citations
National Physical Laboratory India (NPLI) has been developing a cesium atomic fountain primary frequency standard. We have succeeded in trapping about 107Cs atoms, cool them to about 5 μK by both magneto-optical trap (MOT) and polarization gradient cooling (PGC) and launch them up by moving molasses method. We have demonstrated the fountain action by launching the atoms up to 72.9 cm up and detection of the return signal by measuring the fluorescence. Work is underway to interrogate the launched atoms with microwaves and observe Ramsey fringes.
The results of characterization of cold cloud of cesium (Cs) atoms trapped in a magneto-optical trap (MOT) have been presented. The MOT is a part of the Physics package of the Cs Fountain Clock being developed at National Physical Laboratory (NPL), India. The number of atoms, size and temperature of the cloud have been measured and calculated. It is also been investigated how the number of trapped atoms changes with the trapping laser’s beam intensity, detuning and magnetic-field gradient of the trap.
The accelerated development of laser methods for manipulating the internal state and motion of atoms, and the recent primary evaluation in France of a cesium frequency standard using cold atoms in an atomic fountain configuration, allow the frontiers of time metrology, accuracy, and stability to be pushed near parts in the 1016 level, a factor of 100 over the present primary laboratory clocks. These positive results revived the development of more accurate cesium atomic clocks, and the Institute of National Measurement Standards (INMS), of the National Research Council of Canada (NRC) is undertaking a cesium-fountain project aimed at reaching these new levels of accuracy and stability. This paper reviews its present status. To appreciate the considerable impact of cold atoms in time and frequency metrology, we begin by recalling the background principles of traditional cesium frequency standards, their typical performance and main limitations. After introducing the important theoretical results essential to understanding the techniques of laser cooling and magneto-optical trapping, we focus on describing the characterization and control of our magneto-optical trap (MOT) and report the parameters that allow us to fill the trap with a few million atoms in less than a second and cool them to a temperature lower than 5 muK using optical molasses. We will describe the specifics of our cesium-fountain prototype, which operates with a 2-dimensional moving molasses. This special configuration is applicable for multipulse operation of the fountain, which can greatly relax the local oscillator requirements for time keeping. Finally, progress toward our objective of launching cooled atoms, at a rate of one ensemble per second, at speeds of 7 m/s, for a fountain with an interrogation time of about 1 s, will be analysed.PACS Nos.: 06.20, 06.30, and 32.80P
We present a progress report on laser-cooled cesium atoms at NRC, work which was started a few years ago in order to realize a cesium fountain frequency standard. We selected an acceleration with two-dimensional moving molasses, which can increase both the force and the interaction time by a factor of /spl radic/2 over the more common 1-D molasses scheme. This configuration also allows for trapping and cooling of atoms while previously launched atoms are still moving in the clock section of the system. We report measurements on the number of atoms, temperature, friction coefficient and spring constant of our magneto-optical trap and 1-D molasses for various conditions.
A cesium frequency standard based on the atomic fountain configuration has the potential of improving the accuracy of primary frequency standard. For the first step toward a realization of slow vertical atomic beam (that is an atomic fountain), we have succeeded to decelerate the horizontal cesium atomic beam by laser cooling with the Zeeman tuning method. Then those slowed atoms are confined with a magneto-optical trap by four laser beams in the tetrahedral configuration. By using these trapped atoms, one can launch them upward with the upstream laser pulses.>
To achieve a primary frequency standard based on a continuous fountain of laser cooled cesium atoms, we report on the production of a bright, slow and cold continuous atomic beam. Atoms are cooled from a thermal vapor in a 45/spl deg/ laser geometry and launched directly from the optical molasses by the moving molasses technique. The effects of the source fluorescence on the continuous beam (average velocity, temperature and flux) have been observed, and ways to optimize simultaneously the atomic capture and the continuous beam are presented. Flux measurements rise to 2/spl times/10/sup 8/ at/s from a 2D magneto-optical trap at 7 m/s. The initial velocity is easily tunable from 1 to 10 m/s. If the longitudinal temperature is about 70 /spl mu/K, additional transverse cooling even reduces the transverse temperature in one dimension below 30 /spl mu/K. By extrapolating the obtained atomic flux to the continuous fountain under construction, we expect a short-term stability of 7/spl times/10/sup -14//spl tau//sup -1/2/. Other applications of continuous beams of cold atoms are suggested.