Photonics Research

Achievement of record short-term frequency stability of a cesium atomic fountain clock

Mingming Liu, YAN ZHENG, Yijun Luo, Zhiyuan Wang, Yuanbo Du, Hongli liu, Jie Zhang, Zehuang Lu

Published Nov 12, 2026• 0 citations
Publisher

Abstract

Frequency stability is one of the key performance indicators of primary atomic clocks. The short-term frequency stability of the cesium atomic fountain clock, defined by the closed-loop Allan deviation in the white-noise averaging regime ( τ −1/2 ), is fundamentally limited by two mechanisms: the atomic detection signal-to-noise ratio (SNR) and the Dick effect. The former is governed by the atom-number-dependent quantum projection noise (QPN), while the latter stems from the phase noise of the local oscillator (LO). Here, we report the development of improved short-term frequency stability for the cesium atomic fountain clock, HUST-CsF1. A high-loading-efficiency two-dimensional magneto-optical trap (2D-MOT) with optical molasses is employed, boosting the SNR of the Ramsey fringe to 2730±112, corresponding to a QPN limit of 1.33(5)×10 −14 τ −1/2 . A photonic microwave generation source with a single-sideband phase noise of −112 dBc / Hz at 1 Hz offset is developed, with the calculated Dick effect contribution reduced to 1.4×10 −15 τ −1/2 . Ultimately, a short-term frequency stability of 1.4×10 −14 τ −1/2 is achieved, representing the best performance reported for atomic fountain clocks in the literature to date.

DOI
10.1364/prj.612100

Related papers

Quantum Projection Noise in an Atomic Fountain: A High Stability Cesium Frequency Standard

Giorgio Santarelli, Philippe Laurent, P. Lemonde +5 more

We describe the operation of a laser cooled cesium fountain clock in the quantum limited regime. An ultrastable cryogenic sapphire oscillator is used to measure the short-term frequency stability of the fountain as a function of the number of detected atoms ${N}_{\mathrm{at}}$. For ${N}_{\mathrm{at}}$ varying from $4\ifmmode\times\else\texttimes\fi{}{10}^{4}$ to $6\ifmmode\times\else\texttimes\fi{}{10}^{5}$ the Allan standard deviation of the frequency fluctuations is in excellent agreement with the ${N}_{\mathrm{at}}^{\ensuremath{-}1/2}$ law of atomic projection noise. With $6\ifmmode\times\else\texttimes\fi{}{10}^{5}$ atoms, the relative frequency stability is $4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$, where \ensuremath{\tau} is the integration time in seconds. This is the best short-term stability ever reported for primary frequency standards, a factor of 5 improvement over previous results.

Physical Review Letters•Jun 7, 1999•646 citations

An intense, highly collimated continuous Cesium fountain

N. Castagna

The realisation of cold and slow atomic beams has opened the way to a series of precision measurements of high scientific interest, as atom interferometry, Bose-Einstein Condensation and atomic fountain clocks. The latter are used since several years as reference clocks, given the high performance that they can reach both in accuracy and stability. The common philosophy in the construction of atomic fountains has been the pulsed technique, where an atoms sample is launched vertically and then falls down under the effect of the gravity. The Observatoire de Neuchâtel had a different approach and has built a fountain clock (FOCS1) operating in a continuous mode. This technique offers two main advantages: the diminution of the undesirable effects due to the atomic density (e.g. collisions between the atoms and cavity pulling) and to the noise of the local oscillator (intermodulation effect). To take full advantage of the continuous fountain approach however, we need to increase the atomic flux. The techniques chosen to reach this goal are an efficient transverse collimation together with more atoms to begin with. Here we report on a study of different transverse collimation techniques performed in a two-dimensional phase stable optical lattice (namely gray molasses and magnetically induced laser cooling) as well as the development and characterisation of a 2D-magneto-optical trap used to load the fountain. Best performances are reached in a 2D+-MOT configuration of such a pre-source, for which we detect an atomic flux 20 times greater than the one measured when the fountain is loaded by a Cs vapour. This gain could improve the atomic clock stability by a factor 6. An even better stability is expected after introducing a pre-cooling stage before performing the transverse collimation. This new configuration is currently under investigation and will be implemented in a second continuous fountain (FOCS2).

•Jan 1, 2006•0 citations

An intense, highly collimated continous cesium fountain

N. Castagna

The realisation of cold and slow atomic beams has opened the way to a series of precision measurements of high scientific interest, as atom interferometry, Bose-Einstein Condensation and atomic fountain clocks. The latter are used since several years as reference clocks, given the high performance that they can reach both in accuracy and stability. The common philosophy in the construction of atomic fountains has been the pulsed technique, where an atoms sample is launched vertically and then falls down under the effect of the gravity. The Observatoire de Neuchâtel had a different approach and has built a fountain clock (FOCS1) operating in a continuous mode. This technique offers two main advantages: the diminution of the undesirable effects due to the atomic density (e.g. collisions between the atoms and cavity pulling) and to the noise of the local oscillator (intermodulation effect). To take full advantage of the continuous fountain approach however, we need to increase the atomic flux. The techniques chosen to reach this goal are an efficient transverse collimation together with more atoms to begin with. Here we report on a study of different transverse collimation techniques performed in a two-dimensional phase stable optical lattice (namely gray molasses and magnetically induced laser cooling) as well as the development and characterisation of a 2D-magneto-optical trap used to load the fountain. Best performances are reached in a 2D+-MOT configuration of such a pre-source, for which we detect an atomic flux 20 times greater than the one measured when the fountain is loaded by a Cs vapour. This gain could improve the atomic clock stability by a factor 6. An even better stability is expected after introducing a pre-cooling stage before performing the transverse collimation. This new configuration is currently under investigation and will be implemented in a second continuous fountain (FOCS2).

•Jan 1, 2006•0 citations

A CPT-based Cs vapor cell atomic clock with a short-term fractional frequency stability of 3 x 10-13τ-1/2

Moustafa Abdel Hafiz, Xiaochi Liu, Stéphane Guérandel +2 more

This article reports on the development and short-term fractional frequency stability of a continuous-regime (CW) Cs vapor cell atomic clock based on coherent population trapping (CPT). The push-pull optical pumping technique is used to increase the number of atoms that participate to the clock transition, yielding a typical CPT resonance contrast of 25% for a CPT linewidth of about 450 Hz. The clock short-term fractional frequency stability is measured to be 3 x 10 -13 τ -1/2 up to 100 seconds averaging time, in correct agreement with the signal-to-noise ratio limit. The mid-term frequency stability results are currently mainly limited by laser power effects. The detection of high-contrast narrow Raman-Ramsey fringes is demonstrated with this setup by making the atoms interact with a light pulse sequence.

Journal of Physics Conference Series•Jun 1, 2016•9 citations

Reaching the quantum limit in a fountain clock using a microwave oscillator phase locked to an ultrastable laser

S. Weyers, B. Lipphardt, H. Schnatz

A cesium fountain clock is operated utilizing a microwave oscillator that derives its frequency stability from a stable laser by means of a fiber-laser femtosecond frequency comb. This oscillator is based on the technology developed for optical clocks and replaces the quartz-based microwave oscillator commonly used in fountain clocks. As a result, a significant decrease in the frequency instability of the fountain clock is obtained, reaching $7.4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}{[\ensuremath{\tau}\text{ }(\text{s})]}^{\ensuremath{-}1/2}$. We could demonstrate that for a significant range of detected atom numbers the instability is limited by quantum projection noise only, and that for the current status of this fountain clock the microwave source poses no limit on the achievable frequency instability.

arXiv:0901.2788•Physical Review A•Mar 11, 2009•87 citations

Improvement of the short-term stability of atomic fountain clock with state preparation by two-laser optical pumping*

Lei Han, Fang Fang, Weiliang Chen +4 more

To improve the signal to noise ratio (SNR) and the short-term stability of cesium atomic fountain clocks, the work of two-laser optical pumping is presented theoretically and experimentally. The short-term stability of the NIM6 fountain clock has been improved by preparing more cold atoms in the | F = 4, mF = 0〉 clock state with a shortened cycle time. Two π-polarized laser beams overlapped in the horizontal plane have been applied after launching, one is resonant with | F = 4〉 → | F′ = 4〉 transition and the other is resonant with | F = 3〉 → | F′ = 4〉 transition. With optical pumping, the population accumulated in the | mF = 0〉 clock state is improved from 11% to 63%, and the detection signal is increased by a factor of 4.2, the SNR of the clock transition probability and the short-term stability are also improved accordingly.

Chinese Physics B•Feb 2, 2021•4 citations
Frequency stability is one of the key performance indicators of primary atomic clocks. The short-term frequency stability of the cesium atomic fountain clock, defined by the closed-loop Allan deviation in the white-noise averaging regime ( τ −1/2 ), is fundamentally limited by two mechanisms: the atomic detection signal-to-noise ratio (SNR) and the Dick effect. The former is governed by the atom-number-dependent quantum projection noise (QPN), while the latter stems from the phase noise of the local oscillator (LO). Here, we report the development of improved short-term frequency stability for the cesium atomic fountain clock, HUST-CsF1. A high-loading-efficiency two-dimensional magneto-optical trap (2D-MOT) with optical molasses is employed, boosting the SNR of the Ramsey fringe to 2730±112, corresponding to a QPN limit of 1.33(5)×10 −14 τ −1/2 . A photonic microwave generation source with a single-sideband phase noise of −112 dBc / Hz at 1 Hz offset is developed, with the calculated Dick effect contribution reduced to 1.4×10 −15 τ −1/2 . Ultimately, a short-term frequency stability of 1.4×10 −14 τ −1/2 is achieved, representing the best performance reported for atomic fountain clocks in the literature to date.
We describe the operation of a laser cooled cesium fountain clock in the quantum limited regime. An ultrastable cryogenic sapphire oscillator is used to measure the short-term frequency stability of the fountain as a function of the number of detected atoms Nat{N}_{\mathrm{at}}Nat​. For Nat{N}_{\mathrm{at}}Nat​ varying from $4\ifmmode\times\else\texttimes\fi{}{10}^{4}$ to $6\ifmmode\times\else\texttimes\fi{}{10}^{5}$ the Allan standard deviation of the frequency fluctuations is in excellent agreement with the ${N}_{\mathrm{at}}^{\ensuremath{-}1/2}$ law of atomic projection noise. With $6\ifmmode\times\else\texttimes\fi{}{10}^{5}$ atoms, the relative frequency stability is $4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$, where \ensuremath{\tau} is the integration time in seconds. This is the best short-term stability ever reported for primary frequency standards, a factor of 5 improvement over previous results.
The realisation of cold and slow atomic beams has opened the way to a series of precision measurements of high scientific interest, as atom interferometry, Bose-Einstein Condensation and atomic fountain clocks. The latter are used since several years as reference clocks, given the high performance that they can reach both in accuracy and stability. The common philosophy in the construction of atomic fountains has been the pulsed technique, where an atoms sample is launched vertically and then falls down under the effect of the gravity. The Observatoire de Neuchâtel had a different approach and has built a fountain clock (FOCS1) operating in a continuous mode. This technique offers two main advantages: the diminution of the undesirable effects due to the atomic density (e.g. collisions between the atoms and cavity pulling) and to the noise of the local oscillator (intermodulation effect). To take full advantage of the continuous fountain approach however, we need to increase the atomic flux. The techniques chosen to reach this goal are an efficient transverse collimation together with more atoms to begin with. Here we report on a study of different transverse collimation techniques performed in a two-dimensional phase stable optical lattice (namely gray molasses and magnetically induced laser cooling) as well as the development and characterisation of a 2D-magneto-optical trap used to load the fountain. Best performances are reached in a 2D+-MOT configuration of such a pre-source, for which we detect an atomic flux 20 times greater than the one measured when the fountain is loaded by a Cs vapour. This gain could improve the atomic clock stability by a factor 6. An even better stability is expected after introducing a pre-cooling stage before performing the transverse collimation. This new configuration is currently under investigation and will be implemented in a second continuous fountain (FOCS2).
The realisation of cold and slow atomic beams has opened the way to a series of precision measurements of high scientific interest, as atom interferometry, Bose-Einstein Condensation and atomic fountain clocks. The latter are used since several years as reference clocks, given the high performance that they can reach both in accuracy and stability. The common philosophy in the construction of atomic fountains has been the pulsed technique, where an atoms sample is launched vertically and then falls down under the effect of the gravity. The Observatoire de Neuchâtel had a different approach and has built a fountain clock (FOCS1) operating in a continuous mode. This technique offers two main advantages: the diminution of the undesirable effects due to the atomic density (e.g. collisions between the atoms and cavity pulling) and to the noise of the local oscillator (intermodulation effect). To take full advantage of the continuous fountain approach however, we need to increase the atomic flux. The techniques chosen to reach this goal are an efficient transverse collimation together with more atoms to begin with. Here we report on a study of different transverse collimation techniques performed in a two-dimensional phase stable optical lattice (namely gray molasses and magnetically induced laser cooling) as well as the development and characterisation of a 2D-magneto-optical trap used to load the fountain. Best performances are reached in a 2D+-MOT configuration of such a pre-source, for which we detect an atomic flux 20 times greater than the one measured when the fountain is loaded by a Cs vapour. This gain could improve the atomic clock stability by a factor 6. An even better stability is expected after introducing a pre-cooling stage before performing the transverse collimation. This new configuration is currently under investigation and will be implemented in a second continuous fountain (FOCS2).
This article reports on the development and short-term fractional frequency stability of a continuous-regime (CW) Cs vapor cell atomic clock based on coherent population trapping (CPT). The push-pull optical pumping technique is used to increase the number of atoms that participate to the clock transition, yielding a typical CPT resonance contrast of 25% for a CPT linewidth of about 450 Hz. The clock short-term fractional frequency stability is measured to be 3 x 10 -13 τ -1/2 up to 100 seconds averaging time, in correct agreement with the signal-to-noise ratio limit. The mid-term frequency stability results are currently mainly limited by laser power effects. The detection of high-contrast narrow Raman-Ramsey fringes is demonstrated with this setup by making the atoms interact with a light pulse sequence.
A cesium fountain clock is operated utilizing a microwave oscillator that derives its frequency stability from a stable laser by means of a fiber-laser femtosecond frequency comb. This oscillator is based on the technology developed for optical clocks and replaces the quartz-based microwave oscillator commonly used in fountain clocks. As a result, a significant decrease in the frequency instability of the fountain clock is obtained, reaching $7.4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}{[\ensuremath{\tau}\text{ }(\text{s})]}^{\ensuremath{-}1/2}$. We could demonstrate that for a significant range of detected atom numbers the instability is limited by quantum projection noise only, and that for the current status of this fountain clock the microwave source poses no limit on the achievable frequency instability.
To improve the signal to noise ratio (SNR) and the short-term stability of cesium atomic fountain clocks, the work of two-laser optical pumping is presented theoretically and experimentally. The short-term stability of the NIM6 fountain clock has been improved by preparing more cold atoms in the | F = 4, mF = 0〉 clock state with a shortened cycle time. Two π-polarized laser beams overlapped in the horizontal plane have been applied after launching, one is resonant with | F = 4〉 → | F′ = 4〉 transition and the other is resonant with | F = 3〉 → | F′ = 4〉 transition. With optical pumping, the population accumulated in the | mF = 0〉 clock state is improved from 11% to 63%, and the detection signal is increased by a factor of 4.2, the SNR of the clock transition probability and the short-term stability are also improved accordingly.