Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Laboratory Science

Optimization and reserach of Rb vapor cell of CPT atomic clock

Guo Jia-tai

Published Jan 1, 2013• 0 citations
OpenAlex

Abstract

In order to meeting the high stability of the coherent population trapping(CPT) atomic clock,we studied the relationship between CPT resonance frequency shift with pressure ratio of the buffer gases(argon and neon) through the 300μm thickness rubidium cell.When the total pressure of the buffer gases was 10 kPa,We found that the frequency shift rate varied along a bell shaped curve,and when the pressure ratio of Ar and Ne was 1:1.2 or 1.2:1,CPT resonance frequency drift rate was zero.

Related papers

Effect of buffer gas ratios on the relationship between cell temperature and frequency shifts of the coherent population trapping resonance

Ke Deng, T. Guo, Dingwu He +5 more

We studied the relationship between pressure ratio of the buffer gases (argon and neon) and the rate of coherent population trapping resonance frequency shift with cell temperature in Rb85. We found that when the total pressure of the buffer gases varies within the range of 5–15kPa, the frequency shift rate varies along a bell shaped curve. Every curve crossed the horizontal axis at two points that are roughly symmetrical with respect to the midpoint at 1:1. This allows us to minimize the rate of frequency shift by adjusting the pressure ratio of the buffer gases to these two points.

Applied Physics Letters•May 26, 2008•33 citations

Study and Optimization of CPT Resonance Parameters in 87 Rb/Ar/Ne Microcells Aimed for Application in Metrology

Y. Masian, A. V. Sivak, D. I. Sevostianov +2 more

The paper shows the presents results of studies of small-size rubidium cells with argon and neon buffer gases, produced by a patent pended technique of laser welding [Fishman et al. (2014)]. Cells were designed for miniature frequency standard. Temperature dependence of the frequency of the coherent population trapping (CPT) resonance was measured and used to optimize the ratio of partial pressures of buffer gases. The influence of duration and regime of annealing on the CPT-resonance frequency drift was investigated. The parameters of the FM modulation of laser current for two cases which correspond to the highest amplitude of CPT resonance and to the smallest light shifts of the resonance frequency were determined. The temperature dependences of the CPT resonance frequency were found to be surprisingly different in the two cases. A non-linear dependence of CPT resonance frequency on the temperature of the cell with the two extremes was revealed for one of these cases.

Physics Procedia•Jan 1, 2015•6 citations

Nitrogen-Pressure Dependence of Coherent Population Trapping Signal Characteristics in Microfabricated Rubidium Vapor Cells

Shun Kiyose, Masahiro Fukuoka, Yusuke Odagiri +4 more

Controlling buffer-gas conditions in vapor cells is essential for frequency stabilization and atomic-clock performance. This study investigated the dependence of coherent population trapping (CPT) signal characteristics on nitrogen (N ${}_{2}$ ) buffer-gas pressure in micro-fabricated vapor cells containing natural-abundance rubidium (Rb) generated from Rb azide (RbN ${}_{3}$ ) for chip-scale atomic clocks. A wafer-level fabrication method enabling individual control of N2 pressure was developed by inkjet patterning of RbN3 and subsequent krypton fluoride (KrF) excimer laser decomposition. An increasing N2 pressure was found to reduce the CPT linewidth and cause a significant decrease in the signal amplitude, which resulted in monotonic degradation in the CPT figure of merit with higher pressures. A CPT-based laser frequency stabilization method that locked the laser wavelength to the CPT resonance peak yielded significantly larger signal amplitudes than a conventional absorption-based method in the low-pressure regime below 8 kPa. These results show that CPT performance in micro-fabricated Rb vapor cells is more restricted by the signal amplitude rather than the linewidth. They also offer practical buffer-gas design guidelines for enhancing short-term frequency stability in chip-scale atomic clocks.

IEEE Open Journal of Ultrasonics Ferroelectrics and Frequency Control•Jan 1, 2026•0 citations

Stability properties of an Rb CPT atomic clock with buffer-gas-free cells under dynamic excitation

Sergey M Kobtsev, Daba A. Radnatarov, Sergey Khripunov +3 more

This work presents a study of the short-term stability properties of Rb atomic clocks based on coherent population trapping (CPT) under dynamic excitation of a CPT resonance in cells without buffer gas. It is demonstrated that in an optical cell with anti-relaxation coating of its inner walls, the best stability is achieved at the scanning frequency of the frequency difference of the bichromatic pump field equal to 2 kHz at the resonance width of 450 Hz. In cells without a wall coating, the optimal scanning frequency range is found to be 1.2–2.8 kHz at the resonance width of 29 kHz. Examination of the slope of the stabilization system’s discriminant curve at zero error signal for buffer-gas-free cells uncovered an amount of correlation between the discriminant curve slope and atomic clock stability. It is demonstrated that the highest stability of atomic clocks in dynamic excitation mode is achieved at a ratio of scanning frequency and amplitude around 1.

Journal of the Optical Society of America B•Sep 10, 2019•15 citations

A 85Rb coherent population trapping atomic clock

Ke Deng, Xuzong Chen, Zhong Wang

This paper introduce three main technologies in our coherent population trapping clock. The rubidium vapor cell is fabricated by glass-silicon anodic bonding techniques. We use two different buffer gases (Ar and Ne) that produce opposite shift rates to reduce the dependence of the clock frequency stability on the temperature stability of the atoms. We use the ceramic-filled coaxial resonator as the RF resource.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jun 1, 2010•2 citations

Characterizing passive coherent population trapping resonance in a cesium vapor cell filled with neon buffer gas

Zhi Liu, Jieying Wang, Wen-Ting Diao +2 more

We present a pair of phase-locked lasers with a 9.2-GHz frequency difference through the injection locking of a master laser to the RF-modulation sideband of a slave diode laser. Using this laser system, a coherent population trapping (CPT) signal with a typical linewidth of ∼ 182 Hz is obtained in a cesium vapor cell filled with 30 Torr (4 kPa) of neon as the buffer gas. We investigate the influence of the partial pressure of the neon buffer gas on the CPT linewidth, amplitude, and frequency shift. The results may offer some references for CPT atomic clocks and CPT atomic magnetometers.

Chinese Physics B•Apr 1, 2013•4 citations
In order to meeting the high stability of the coherent population trapping(CPT) atomic clock,we studied the relationship between CPT resonance frequency shift with pressure ratio of the buffer gases(argon and neon) through the 300μm thickness rubidium cell.When the total pressure of the buffer gases was 10 kPa,We found that the frequency shift rate varied along a bell shaped curve,and when the pressure ratio of Ar and Ne was 1:1.2 or 1.2:1,CPT resonance frequency drift rate was zero.
We studied the relationship between pressure ratio of the buffer gases (argon and neon) and the rate of coherent population trapping resonance frequency shift with cell temperature in Rb85. We found that when the total pressure of the buffer gases varies within the range of 5–15kPa, the frequency shift rate varies along a bell shaped curve. Every curve crossed the horizontal axis at two points that are roughly symmetrical with respect to the midpoint at 1:1. This allows us to minimize the rate of frequency shift by adjusting the pressure ratio of the buffer gases to these two points.
The paper shows the presents results of studies of small-size rubidium cells with argon and neon buffer gases, produced by a patent pended technique of laser welding [Fishman et al. (2014)]. Cells were designed for miniature frequency standard. Temperature dependence of the frequency of the coherent population trapping (CPT) resonance was measured and used to optimize the ratio of partial pressures of buffer gases. The influence of duration and regime of annealing on the CPT-resonance frequency drift was investigated. The parameters of the FM modulation of laser current for two cases which correspond to the highest amplitude of CPT resonance and to the smallest light shifts of the resonance frequency were determined. The temperature dependences of the CPT resonance frequency were found to be surprisingly different in the two cases. A non-linear dependence of CPT resonance frequency on the temperature of the cell with the two extremes was revealed for one of these cases.
Controlling buffer-gas conditions in vapor cells is essential for frequency stabilization and atomic-clock performance. This study investigated the dependence of coherent population trapping (CPT) signal characteristics on nitrogen (N 2{}_{2}2​ ) buffer-gas pressure in micro-fabricated vapor cells containing natural-abundance rubidium (Rb) generated from Rb azide (RbN 3{}_{3}3​ ) for chip-scale atomic clocks. A wafer-level fabrication method enabling individual control of N2 pressure was developed by inkjet patterning of RbN3 and subsequent krypton fluoride (KrF) excimer laser decomposition. An increasing N2 pressure was found to reduce the CPT linewidth and cause a significant decrease in the signal amplitude, which resulted in monotonic degradation in the CPT figure of merit with higher pressures. A CPT-based laser frequency stabilization method that locked the laser wavelength to the CPT resonance peak yielded significantly larger signal amplitudes than a conventional absorption-based method in the low-pressure regime below 8 kPa. These results show that CPT performance in micro-fabricated Rb vapor cells is more restricted by the signal amplitude rather than the linewidth. They also offer practical buffer-gas design guidelines for enhancing short-term frequency stability in chip-scale atomic clocks.
This work presents a study of the short-term stability properties of Rb atomic clocks based on coherent population trapping (CPT) under dynamic excitation of a CPT resonance in cells without buffer gas. It is demonstrated that in an optical cell with anti-relaxation coating of its inner walls, the best stability is achieved at the scanning frequency of the frequency difference of the bichromatic pump field equal to 2 kHz at the resonance width of 450 Hz. In cells without a wall coating, the optimal scanning frequency range is found to be 1.2–2.8 kHz at the resonance width of 29 kHz. Examination of the slope of the stabilization system’s discriminant curve at zero error signal for buffer-gas-free cells uncovered an amount of correlation between the discriminant curve slope and atomic clock stability. It is demonstrated that the highest stability of atomic clocks in dynamic excitation mode is achieved at a ratio of scanning frequency and amplitude around 1.
We present a pair of phase-locked lasers with a 9.2-GHz frequency difference through the injection locking of a master laser to the RF-modulation sideband of a slave diode laser. Using this laser system, a coherent population trapping (CPT) signal with a typical linewidth of ∼ 182 Hz is obtained in a cesium vapor cell filled with 30 Torr (4 kPa) of neon as the buffer gas. We investigate the influence of the partial pressure of the neon buffer gas on the CPT linewidth, amplitude, and frequency shift. The results may offer some references for CPT atomic clocks and CPT atomic magnetometers.