Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

A 85Rb coherent population trapping atomic clock

Ke Deng, Xuzong Chen, Zhong Wang

Published Jun 1, 2010• 2 citations
Publisher

Abstract

This paper introduce three main technologies in our coherent population trapping clock. The rubidium vapor cell is fabricated by glass-silicon anodic bonding techniques. We use two different buffer gases (Ar and Ne) that produce opposite shift rates to reduce the dependence of the clock frequency stability on the temperature stability of the atoms. We use the ceramic-filled coaxial resonator as the RF resource.

DOI
10.1109/freq.2010.5556287

Related papers

Microfabrication of 85Rb vapor cell for chip-scale atomic clocks

Juan Su, Ke Deng, Zhong Wang +1 more

We describe the fabrication of Rubidium (Rb) vapor cells using glass-silicon anodic bonding techniques and chemical reaction between rubidium chloride and barium azide. The pure metallic Rb drops and buffer gases were obtained in the cells with few mm3internal volumes. The optical absorption resonance of85Rb D1 transition with proper broadening and the corresponding coherent population trapping (CPT) resonance, with a signal contrast of 1.5% and linewidth of about 1.7 KHz, have been detected at 90degC.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2009•8 citations

Stable85Rb micro vapour cells: fabrication based on anodic bonding and application in chip-scale atomic clocks

苏娟, Ke Deng, Deng-Zhu Guo +4 more

We describe the microfabrication of 85 Rb vapour cells using a glass-silicon anodic bonding technique and in situ chemical reaction between rubidium chloride and barium azide to produce Rb. Under controlled conditions, the pure metallic Rb drops and buffer gases were obtained in the cells with a few mm 3 internal volumes during the cell sealing process. At an ambient temperature of 90 °C the optical absorption resonance of 85 Rb D1 transition with proper broadening and the corresponding coherent population trapping (CPT) resonance, with a signal contrast of 1.5% and linewidth of about 1.7 kHz, have been detected. The sealing quality and the stability of the cells have also been demonstrated experimentally by using the helium leaking detection and the after-9-month optoelectronics measurement which shows a similar CPT signal as its original status. In addition, the physics package of chip-scale atomic clock (CSAC) based on the cell was realized. The measured frequency stability of the physics package can reach to 2.1 × 10 −10 at one second when the cell was heated to 100 °C which proved that the cell has the quality to be used in portable and battery-operated devices.

Chinese Physics B•Nov 1, 2010•13 citations

Fabrication of Cesium Vapor Cells for Chip-Scale Atomic Clock Based on Coherent Population Trapping

Alexey Kazakin, Yu. D. Akul'shin, Yakov Enns +3 more

The article presents the results of the development, fabrication and investigation of miniature cesium vapor cells for quantum frequency standards with optical pumping, working on the effect of coherent population trapping. Microelectromechanical systems technologies were used in the manufacture of cells. For the first time, the dry silicon etching in inductively coupled plasma of sulfur hexafluoride and freon gas in a mixed mode was used to form internal cavities of cells with a thickness of 1.5 mm. Vacuum-tight sealing of cells containing a solid-state source of cesium vapor and buffer gas was carried out by anodic bonding of glass and silicon in a neon atmosphere. The coherent population trapping signal with a linewidth of 750 Hz and a signal-to-noise ratio of 1190 in the 1-Hz bandwidth was observed. Experimental results show that these microcells are appropriate for applications to atomic clock with a relative frequency stability of$6\cdot 10^{-11}$at 1 s.

International Conference on Electrical Engineering and Photonics (EExPolytech)•Oct 20, 2022•1 citation

Optimization and reserach of Rb vapor cell of CPT atomic clock

Guo Jia-tai

In order to meeting the high stability of the coherent population trapping(CPT) atomic clock,we studied the relationship between CPT resonance frequency shift with pressure ratio of the buffer gases(argon and neon) through the 300μm thickness rubidium cell.When the total pressure of the buffer gases was 10 kPa,We found that the frequency shift rate varied along a bell shaped curve,and when the pressure ratio of Ar and Ne was 1:1.2 or 1.2:1,CPT resonance frequency drift rate was zero.

Laboratory Science•Jan 1, 2013•0 citations

Microfabrication and Measurement of Rb-Ne Microcell for Chip-Scale Atomic Clocks

Fan Zhang, Yong Ruan, Yanying Feng +1 more

We report the fabrication of a micro vapor cell which has Rb and Ne inside with internal volumes of several millimeters, which is the key component of chip-scale atomic devices like clocks and magnetometers. The cells were filled with Ne at a controlled pressure as the buffer gas by using glass-silicon anodic bonding techniques and dispenser pills of SAES Getters. And a special two-step bonding method was taken to avoid breakdown caused by the buffer gas and to secure the quality of the bonding. We also built an optical measuring system and measured the coherent population trapping (CPT) resonance of85Rb D1 line with a linewidth below 2.0 kHz and a contrast about 1.1%. Zeeman spectrum for CPT resonance was also detected in these microcells. These results show that these vapor cells are capable to be used in atomic clocks or magnetometers.

IEEE CSAA Guidance, Navigation and Control Conference (CGNCC)•Aug 1, 2018•0 citations

Microfabricated cells for chip-scale atomic clock based on coherent population trapping: Fabrication and investigation

Ермак Сергей Викторович, V. V. Semenov, Пятышев Евгений Нилович +5 more

A universal method for fabrication of miniature cells for frequency standards and quantum magnetometers containing 87Rb atoms in the atmosphere of inert gas neon based on integrated technologies is considered. The results of experimental studies of coherent population trapping signals observed for a series of cells which provided recovery of vapors of an alkali metal from the rubidium dichromate salt with the help of laser radiation are presented. The coherent population trapping signals with a typical linewidth of 2–3 kHz and a signal-to-noise ratio of 1500 in the 1-Hz bandwidth were observed, which allows one to provide a relative frequency stability of atomic clock of 10−11 at 100 s.

St Petersburg Polytechnical University Journal Physics and Mathematics•Mar 1, 2015•10 citations
This paper introduce three main technologies in our coherent population trapping clock. The rubidium vapor cell is fabricated by glass-silicon anodic bonding techniques. We use two different buffer gases (Ar and Ne) that produce opposite shift rates to reduce the dependence of the clock frequency stability on the temperature stability of the atoms. We use the ceramic-filled coaxial resonator as the RF resource.
We describe the fabrication of Rubidium (Rb) vapor cells using glass-silicon anodic bonding techniques and chemical reaction between rubidium chloride and barium azide. The pure metallic Rb drops and buffer gases were obtained in the cells with few mm3internal volumes. The optical absorption resonance of85Rb D1 transition with proper broadening and the corresponding coherent population trapping (CPT) resonance, with a signal contrast of 1.5% and linewidth of about 1.7 KHz, have been detected at 90degC.
We describe the microfabrication of 85 Rb vapour cells using a glass-silicon anodic bonding technique and in situ chemical reaction between rubidium chloride and barium azide to produce Rb. Under controlled conditions, the pure metallic Rb drops and buffer gases were obtained in the cells with a few mm 3 internal volumes during the cell sealing process. At an ambient temperature of 90 °C the optical absorption resonance of 85 Rb D1 transition with proper broadening and the corresponding coherent population trapping (CPT) resonance, with a signal contrast of 1.5% and linewidth of about 1.7 kHz, have been detected. The sealing quality and the stability of the cells have also been demonstrated experimentally by using the helium leaking detection and the after-9-month optoelectronics measurement which shows a similar CPT signal as its original status. In addition, the physics package of chip-scale atomic clock (CSAC) based on the cell was realized. The measured frequency stability of the physics package can reach to 2.1 × 10 −10 at one second when the cell was heated to 100 °C which proved that the cell has the quality to be used in portable and battery-operated devices.
The article presents the results of the development, fabrication and investigation of miniature cesium vapor cells for quantum frequency standards with optical pumping, working on the effect of coherent population trapping. Microelectromechanical systems technologies were used in the manufacture of cells. For the first time, the dry silicon etching in inductively coupled plasma of sulfur hexafluoride and freon gas in a mixed mode was used to form internal cavities of cells with a thickness of 1.5 mm. Vacuum-tight sealing of cells containing a solid-state source of cesium vapor and buffer gas was carried out by anodic bonding of glass and silicon in a neon atmosphere. The coherent population trapping signal with a linewidth of 750 Hz and a signal-to-noise ratio of 1190 in the 1-Hz bandwidth was observed. Experimental results show that these microcells are appropriate for applications to atomic clock with a relative frequency stability of6⋅10−116\cdot 10^{-11}6⋅10−11at 1 s.
We report the fabrication of a micro vapor cell which has Rb and Ne inside with internal volumes of several millimeters, which is the key component of chip-scale atomic devices like clocks and magnetometers. The cells were filled with Ne at a controlled pressure as the buffer gas by using glass-silicon anodic bonding techniques and dispenser pills of SAES Getters. And a special two-step bonding method was taken to avoid breakdown caused by the buffer gas and to secure the quality of the bonding. We also built an optical measuring system and measured the coherent population trapping (CPT) resonance of85Rb D1 line with a linewidth below 2.0 kHz and a contrast about 1.1%. Zeeman spectrum for CPT resonance was also detected in these microcells. These results show that these vapor cells are capable to be used in atomic clocks or magnetometers.
A universal method for fabrication of miniature cells for frequency standards and quantum magnetometers containing 87Rb atoms in the atmosphere of inert gas neon based on integrated technologies is considered. The results of experimental studies of coherent population trapping signals observed for a series of cells which provided recovery of vapors of an alkali metal from the rubidium dichromate salt with the help of laser radiation are presented. The coherent population trapping signals with a typical linewidth of 2–3 kHz and a signal-to-noise ratio of 1500 in the 1-Hz bandwidth were observed, which allows one to provide a relative frequency stability of atomic clock of 10−11 at 100 s.