Journal of the Optical Society of America B

Stability properties of an Rb CPT atomic clock with buffer-gas-free cells under dynamic excitation

Sergey M Kobtsev, Daba A. Radnatarov, Sergey Khripunov, Ivan Popkov, Valeriy Andryushkov, Tatiana Steshchenko

Published Sep 6, 2019• 15 citations
Publisher

Abstract

This work presents a study of the short-term stability properties of Rb atomic clocks based on coherent population trapping (CPT) under dynamic excitation of a CPT resonance in cells without buffer gas. It is demonstrated that in an optical cell with anti-relaxation coating of its inner walls, the best stability is achieved at the scanning frequency of the frequency difference of the bichromatic pump field equal to 2 kHz at the resonance width of 450 Hz. In cells without a wall coating, the optimal scanning frequency range is found to be 1.2–2.8 kHz at the resonance width of 29 kHz. Examination of the slope of the stabilization system’s discriminant curve at zero error signal for buffer-gas-free cells uncovered an amount of correlation between the discriminant curve slope and atomic clock stability. It is demonstrated that the highest stability of atomic clocks in dynamic excitation mode is achieved at a ratio of scanning frequency and amplitude around 1.

DOI
10.1364/josab.36.002700

Related papers

Atomic clock stability under dynamic excitation of coherent population trapping resonance in cells without buffer gas

Sergey M Kobtsev, Daba A. Radnatarov, Sergey Khripunov +3 more

The present work for the first time reports on studies of properties of dynamically excited coherent population trapping (CPT) resonances in cells without buffer gas (both with and without anti-relaxation coating of their inner walls). Over the 0−3 kHz range of CPT resonance scanning frequencies, the discriminant curve slope was determined, as well as measured stability of atomic clocks. The work provides details of the experiments and analyses prospects of application of results for improvement of atomic clock stability. The work also discusses the newly discovered different character of CPT resonance shape evolution in cells with and without buffer gas.

•Feb 22, 2018•4 citations

Atomic clock based on a coherent population trapping resonance in87Rb with improved high-frequency modulation parameters

Sergey Khripunov, Daba A. Radnatarov, Sergey M Kobtsev

This work reports for the first time development and experimental study of a laboratory prototype of an atomic clock with stability of 2×10–11τ –1/2 (Allan deviation) over time 1 s < τ < 1000 s (7×10–13 over 1000 s) on the basis of a coherent population trapping (CPT) resonance in 87Rb in a compact spherical cell having 1.3-cm diameter and without any buffer gas. Demonstrated are dependencies of the width of the studied CPT resonance upon the amplitude and modulation frequency of optical frequency difference (3.417 GHz) of a bichromatic circularly polarised pump field. For the first time, a considerable non-linearity was discovered in the dependence upon the reference difference frequency of the spectral position of the CPT resonance when the modulation frequency of the optical frequency difference is varied within a broad range.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Mar 10, 2015•19 citations

Optimization and reserach of Rb vapor cell of CPT atomic clock

Guo Jia-tai

In order to meeting the high stability of the coherent population trapping(CPT) atomic clock,we studied the relationship between CPT resonance frequency shift with pressure ratio of the buffer gases(argon and neon) through the 300μm thickness rubidium cell.When the total pressure of the buffer gases was 10 kPa,We found that the frequency shift rate varied along a bell shaped curve,and when the pressure ratio of Ar and Ne was 1:1.2 or 1.2:1,CPT resonance frequency drift rate was zero.

Laboratory Science•Jan 1, 2013•0 citations

New method of wavelength stabilisation in CPT atomic clocks

Sergey M Kobtsev, Daba A. Radnatarov, Sergey Khripunov +2 more

We propose a novel way of radiation wavelength stabilisation in atomic clocks based on coherent population trapping (CPT). It uses quadrature-phase component of the CPT signal within the CPT resonance feedback loop and automatic wavelength locking of radiation from a VCSEL to the atomic absorption line. We demonstrate advantages and limitations of the new method applied to vapour cells with buffer gas or anti-relaxation coating. Also provided are measurements of short- and long-term stability of a CPT-based atomic clock using the proposed method with various optical cells. Discussed are the prospects of this method in chip-scale atomic clocks.

Optoelectronic devices and integration. Conference•Nov 19, 2019•0 citations

Coherent population trapping in small- and chip-scale 87Rb vapor cells with buffer gas

Ермак Сергей Викторович, V. V. Semenov, Mikhail V. Petrenko +1 more

The characteristics of coherent population trapping (CPT) signal were investigated in small-size glass vapor cells containing [Formula: see text]Rb and Ne buffer gas with narrow line-width laser pumping on D2 line. The parameters of CPT signals were measured using small-size vapor cells with Ne buffer gas pressure in the range of 200–400 Torr, cell temperature in the range of 65–120 [Formula: see text]C and the values of laser pumping power of 30–400 [Formula: see text]W/cm2. Optimal conditions, under which the minimal value of short-term instability of resonance line is achieved, were obtained in experiments. Orientation frequency shifts of CPT resonance using glass [Formula: see text]Rb vapor cells containing buffer gas and anti-relaxation coating were compared. CPT signals using vapor cells based on integrated technologies containing [Formula: see text]Rb in atmosphere of Ne were also investigated. The CPT signals with typical line widths of 2–3 kHz and signal-to-noise ratio of 1500 in 1 Hz bandwidth are observed, which allows one to provide relative frequency instability of 10[Formula: see text] at 100 s.

International Journal of Modern Physics Conference Series•Jan 1, 2016•3 citations

Raman–Ramsey Interaction for Coherent Population Trapping Cs Clock

Stéphane Guérandel, T. Zanon-Willette, N. Castagna +4 more

A gas cell atomic frequency standard based on coherent population trapping (CPT) with Ramsey interrogation pulses is developed. The clock resonance is detected in a Cs cell with buffer gas using two phase-locked diode lasers tuned to the D1 line. A preliminary short-term stability of$3.5 \times 10^{-12}t^{-1/2}$is reported. The CPT specificity allows a new interrogation–detection sequence, i.e., the continuous pulse train, which, with phase modulation, could lead to better short-term stability compared to usual continuous CPT clocks. The parameters optimizing the stability include a high Rabi frequency, a very short measurement time, and an interrogation time equal to the lifetime of the hyperfine coherence.

IEEE Transactions on Instrumentation and Measurement•Mar 16, 2007•43 citations
This work presents a study of the short-term stability properties of Rb atomic clocks based on coherent population trapping (CPT) under dynamic excitation of a CPT resonance in cells without buffer gas. It is demonstrated that in an optical cell with anti-relaxation coating of its inner walls, the best stability is achieved at the scanning frequency of the frequency difference of the bichromatic pump field equal to 2 kHz at the resonance width of 450 Hz. In cells without a wall coating, the optimal scanning frequency range is found to be 1.2–2.8 kHz at the resonance width of 29 kHz. Examination of the slope of the stabilization system’s discriminant curve at zero error signal for buffer-gas-free cells uncovered an amount of correlation between the discriminant curve slope and atomic clock stability. It is demonstrated that the highest stability of atomic clocks in dynamic excitation mode is achieved at a ratio of scanning frequency and amplitude around 1.
The present work for the first time reports on studies of properties of dynamically excited coherent population trapping (CPT) resonances in cells without buffer gas (both with and without anti-relaxation coating of their inner walls). Over the 0−3 kHz range of CPT resonance scanning frequencies, the discriminant curve slope was determined, as well as measured stability of atomic clocks. The work provides details of the experiments and analyses prospects of application of results for improvement of atomic clock stability. The work also discusses the newly discovered different character of CPT resonance shape evolution in cells with and without buffer gas.
This work reports for the first time development and experimental study of a laboratory prototype of an atomic clock with stability of 2×10–11τ –1/2 (Allan deviation) over time 1 s < τ < 1000 s (7×10–13 over 1000 s) on the basis of a coherent population trapping (CPT) resonance in 87Rb in a compact spherical cell having 1.3-cm diameter and without any buffer gas. Demonstrated are dependencies of the width of the studied CPT resonance upon the amplitude and modulation frequency of optical frequency difference (3.417 GHz) of a bichromatic circularly polarised pump field. For the first time, a considerable non-linearity was discovered in the dependence upon the reference difference frequency of the spectral position of the CPT resonance when the modulation frequency of the optical frequency difference is varied within a broad range.
We propose a novel way of radiation wavelength stabilisation in atomic clocks based on coherent population trapping (CPT). It uses quadrature-phase component of the CPT signal within the CPT resonance feedback loop and automatic wavelength locking of radiation from a VCSEL to the atomic absorption line. We demonstrate advantages and limitations of the new method applied to vapour cells with buffer gas or anti-relaxation coating. Also provided are measurements of short- and long-term stability of a CPT-based atomic clock using the proposed method with various optical cells. Discussed are the prospects of this method in chip-scale atomic clocks.
The characteristics of coherent population trapping (CPT) signal were investigated in small-size glass vapor cells containing [Formula: see text]Rb and Ne buffer gas with narrow line-width laser pumping on D2 line. The parameters of CPT signals were measured using small-size vapor cells with Ne buffer gas pressure in the range of 200–400 Torr, cell temperature in the range of 65–120 [Formula: see text]C and the values of laser pumping power of 30–400 [Formula: see text]W/cm2. Optimal conditions, under which the minimal value of short-term instability of resonance line is achieved, were obtained in experiments. Orientation frequency shifts of CPT resonance using glass [Formula: see text]Rb vapor cells containing buffer gas and anti-relaxation coating were compared. CPT signals using vapor cells based on integrated technologies containing [Formula: see text]Rb in atmosphere of Ne were also investigated. The CPT signals with typical line widths of 2–3 kHz and signal-to-noise ratio of 1500 in 1 Hz bandwidth are observed, which allows one to provide relative frequency instability of 10[Formula: see text] at 100 s.
A gas cell atomic frequency standard based on coherent population trapping (CPT) with Ramsey interrogation pulses is developed. The clock resonance is detected in a Cs cell with buffer gas using two phase-locked diode lasers tuned to the D1 line. A preliminary short-term stability of3.5×10−12t−1/23.5 \times 10^{-12}t^{-1/2}3.5×10−12t−1/2is reported. The CPT specificity allows a new interrogation–detection sequence, i.e., the continuous pulse train, which, with phase modulation, could lead to better short-term stability compared to usual continuous CPT clocks. The parameters optimizing the stability include a high Rabi frequency, a very short measurement time, and an interrogation time equal to the lifetime of the hyperfine coherence.