Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

OPTIMUM RECEIVER NOISE TEMPERATURE FOR NbN HEB MIXERS ACCORDING TO IRE STANDARD MODEL

K. S. Yngvesson, E. Kollberg

Published Mar 1, 1999• 7 citations
OpenAlex

Related papers

Stability measurements of an NbN HEB receiver at THz frequencies

Therese Berg, Serguei Cherednichenko, Vladimir Drakinskiy +3 more

•Jan 1, 2004•4 citations

Terahertz heterodyne array based on NbN HEB mixers

Serguei Cherednichenko, Vladimir Drakinskiy, B. Lecomte +7 more

•Apr 1, 2008•0 citations

Development of NbN Terahertz, HEB Mixer Devices and Films

Eyal Gerecht, Ashok K. Bhupathiraju, John Nicholson +6 more

•Apr 1, 2003•2 citations

IF Bandwidth of Phonon Cooled HEB Mixers Made from NbN films on MgO Substrates

Serguei Cherednichenko, M. Kroug, Pavel A. Yagoubov +5 more

Softwaretechnik-Trends•May 1, 2000•6 citations

Gain Bandwidth and Noise Temperature of NbTiN HEB Mixer

Gregory N Gol'tsman, Matvey I. Finkel, Yu. B. Vachtomin +4 more

•Apr 1, 2003•4 citations

QUANTUM NOISE CONTRIBUTION TO THE RECEIVER NOISE TEMPERATURE OF HEB THZ HETERODYNE RECEIVERS

E. Kollberg, Sigfrid Yngvesson

In this paper we discuss the quantum limit of bolometric mixer receivers. The importance of the optics attenuation is emphasized. Based on a simple bolometer model we predict that the system and receiver quantum noise limits referred to the input of a double-sideband hotelectron bolometer mixer receiver are, respectively, 2(h113) and 1 (hf/3). The quantum limit to the DSB receiver noise temperature is hf/2k, in agreement with what has previously often been assumed. We suggest that an image-rejection single-sideband version of the HEB mixer would have a system quantum noise limit of WO). We also suggest that at a frequency of several THz the quantum noise may indeed be responsible for about half the total receiver noise temperature in a typical HEB receiver system.

•Mar 1, 2002•5 citations
In this paper we discuss the quantum limit of bolometric mixer receivers. The importance of the optics attenuation is emphasized. Based on a simple bolometer model we predict that the system and receiver quantum noise limits referred to the input of a double-sideband hotelectron bolometer mixer receiver are, respectively, 2(h113) and 1 (hf/3). The quantum limit to the DSB receiver noise temperature is hf/2k, in agreement with what has previously often been assumed. We suggest that an image-rejection single-sideband version of the HEB mixer would have a system quantum noise limit of WO). We also suggest that at a frequency of several THz the quantum noise may indeed be responsible for about half the total receiver noise temperature in a typical HEB receiver system.