In this paper we discuss the quantum limit of bolometric mixer receivers. The importance of the optics attenuation is emphasized. Based on a simple bolometer model we predict that the system and receiver quantum noise limits referred to the input of a double-sideband hotelectron bolometer mixer receiver are, respectively, 2(h113) and 1 (hf/3). The quantum limit to the DSB receiver noise temperature is hf/2k, in agreement with what has previously often been assumed. We suggest that an image-rejection single-sideband version of the HEB mixer would have a system quantum noise limit of WO). We also suggest that at a frequency of several THz the quantum noise may indeed be responsible for about half the total receiver noise temperature in a typical HEB receiver system.
In this paper we discuss the quantum limit of bolometric mixer receivers. The importance of the optics attenuation is emphasized. Based on a simple bolometer model we predict that the system and receiver quantum noise limits referred to the input of a double-sideband hotelectron bolometer mixer receiver are, respectively, 2(h113) and 1 (hf/3). The quantum limit to the DSB receiver noise temperature is hf/2k, in agreement with what has previously often been assumed. We suggest that an image-rejection single-sideband version of the HEB mixer would have a system quantum noise limit of WO). We also suggest that at a frequency of several THz the quantum noise may indeed be responsible for about half the total receiver noise temperature in a typical HEB receiver system.
Receiver noise and RF coupling bandwidth have been measured for a quasioptically coupled diffusion-cooled hot-electron bolometer mixer at a local oscillator frequency of 1267 GHz and an intermediate frequency of 1.4 GHz. A lowest receiver equivalent noise temperature of 1880 K double-sideband was measured, with an upper limit for the mixer noise temperature of 950 K double-sideband. The amount of absorbed local oscillator power in the bolometer device was approximately 6 nW. The effective instantaneous RF bandwidth measured with a Fourier transform spectrometer was 730 GHz.
In this article, we measure the double sideband (DSB) receiver noise temperature (TrecDSB)of an NbN hot electron bolometer (HEB) mixer at three local oscillator frequencies of 1.6, 2.5, and 5.3 THz. The HEB has cleaned contact interfaces with a 200-nm-thick Au layer. The measuredTrecDSBvalues are 530 ± 11 K, 640 ± 18 K, and 2190 ±150 K at 1.6, 2.5, and 5.3 THz, respectively, using an air setup with total optical losses of 2.60 ± 0.04, 2.63 ± 0.16, and 4.70 ± 0.24 dB, respectively. We derived low mixer noise temperatures (TmixerDSB)of 240 ± 6 K at 1.6 THz and 290 ± 13 K at 2.5 THz, achieving over 30% improvement compared to published NbN HEB mixers. This enhancement can reduce the integration time of a heterodyne instrument by roughly a factor of 2. At 5.3 THz,TmixerDSBis 620 ± 55 K, showing limited improvement due to nonoptimized antenna geometry. These results also contribute to understanding the device physics of a wide HEB (4 μm) at high frequencies. The mixer was developed for the proposed Orbiting Astronomical Satellite for Investigating Stellar Systems and Single Aperture Large Telescope for Universe Studies (concept) missions.
We report the measured sensitivities of a superconducting NbN hot electron bolometer (HEB) heterodyne receiver at 5.25 THz. The terahertz (THz) radiation is quasioptically coupled to the HEB mixer with a lens and a spiral antenna. Using a measurement setup with black body calibration sources and a beam splitter in vacuum, and an antireflection coated Si lens, we obtained a double sideband (DSB) receiver noise temperature ( ) of 1150 K, which is 4.5 times h/k (the quantum limit). In addition, the measured far field beam patterns of the integrated lens antenna from 2.5 THz to 5.3 THz show collimated beams that make it reliable to measure using the vacuum setup. Our experimental results in combination with an antenna-to-bolometer coupling simulation suggest that the HEB mixer can work well at least up to 6 THz, suitable for next generation of high-resolution spectroscopic space telescopes and, in particular, for the detection of the neutral atomic oxygen (OI) line at 4.7 THz. DSB rec T
We report on the investigation of optimal bias region of a wide-band superconducting hot electron bolometer (HEB) mixer in terms of noise temperature performance for multi-pixel heterodyne receiver application in the 5-meter Dome A Terahertz Explorer (DATE5) telescope. By evaluating the double sideband (DSB) receiver noise temperature (T rec) across a wide frequency range from 0.2 THz to 1.34 THz and with a large number of bias points, a broad optimal bias region has been observed, illustrating a good bias applicability for multipixel application since the performance of the HEB mixer is uniquely determined by each bias point. The noise temperature of the HEB mixer has been analyzed by calibrating the noise contribution of all RF components, whose transmissions have been measured by a time-domain spectroscopy. The corrected noise temperature distribution shows a frequency independence relation. The dependence of the optimal bias region on the bath temperature of the HEB mixer has also been investigated, the bath temperature has limited effect on the lowest receiver noise temperature until 7 K, however the optimal bias region deteriorates obviously with increasing bath temperature.
Low noise receivers based on superconducting niobium nitride (NbN) hot electron bolometer (HEB) mixers have been designed, fabricated and measured in the terahertz (THz) frequency range for applications in astronomy and cosmology. The NbN HEB mixer consists of a planar antenna and an NbN bridge connecting across the antenna's inner terminals on high-resistivity Si substrates. Double sideband (DSB) receiver noise temperatures of 920 K at 1.6 THz and 1630 K at 2.5 THz have been obtained at 4.2 K without corrections. Effects of Parylene C AR coating on the lens have been studied; with such a coating a lowest DSB receiver noise temperature of 1135 K at 2.5 THz has been obtained at 4.2 K.
Abstract— Superconducting NbN hot electron bolometer (HEB) mixers are so far the most sensitive detectors for\nheterodyne spectroscopy in the frequency range between 1.5 THz and 5 THz. To reach the ultimate receiver noise\ntemperatures in the high end of the THz range (3-6 THz), it is crucial to understand their fundamental noise contribution\nfrom different origins. With increasing frequency, the classical output noise contribution should remain unchanged, but\nthe quantum noise contribution is expected to play an increasing role [1].\nThis paper reports the first dedicated experiment using a single NbN HEB mixer at a number of local oscillator\nfrequencies between 1.6 to 4.3 THz to address and quantify the contribution of the quantum noise to the receiver noise\ntemperature.\nWe used a spiral antenna coupled NbN HEB mixer with a bolometer size of 2 μm×0.2 μm. In order to minimize\nuncertainties in the corrections of the optical losses, we use a vacuum hot/cold load setup [2] to eliminate the air loss, and\nan uncoated elliptical Si lens. Although other components, a 3 μm Mylar beam splitter and a QMC heat filter, also\nintroduce frequency dependent optical losses, they can be accurately calibrated. Furthermore, to reduce uncertainties in\nthe data, we measure Y-factors responding to the hot/cold load by fixing the voltage, but varying the LO power [2]. As\nLO, we use a FIR gas laser.\nWe measure the Y-factor at the optimal point at different frequencies by only varying LO frequencies, but keeping\nthe rest exactly the same. We obtain DSB receiver noise temperatures, which are 842 K (at 1.6 THz), 845 K (1.9 THz), 974\nK (2.5 THz) and 1372 K (4.3 THz). After the correction for the losses of the QMC filter and the beam splitter, the noise\ndata show a linear increase with increasing frequency.\nUsing a quantum noise model [1] for HEB mixers and using a criterion for which the classical output noise must be\nconstant at different frequencies, we analyze the results and find the excess quantum noise factor β to be around 2 and\nthat 24 % of the total receiver noise temperature at 4.3 THz (at the input of the entire receiver) can be ascribed to\nquantum noise. Clearly the quantum noise has a small but measurable effect on the receiver noise temperature at this\nfrequency.\nWe are still analyzing different alternatives of interpretation for the mismatch loss between the bolometer and\nthe spiral antenna.\n[1] E. L. Kollberg and K. S. Yngvesson, “Quantum-noise theory for terahertz hot electron bolometer mixers,” IEEE Trans.\nMicrowave Theory and Techniques, 54, 2077, 2006.\n[2] P. Khosropanah, J.R. Gao, W.M. Laauwen, M. Hajenius and T.M. Klapwijk, “Low noise NbN hot-electron bolometer mixer\nat 4.3 THz,” Appl. Phys. Lett., 91, 221111, 2007.\n