Quantum noise contribution to NbN hot electron bolometer receiver

E. Kollberg, P. Khosropanah, Wen Zhang, K. S. Yngvesson, J. R. Gao, Tarun Bansal, Merlijn Hajenius

Published Jan 1, 2009• 0 citations
OpenAlex

Abstract

Abstract— Superconducting NbN hot electron bolometer (HEB) mixers are so far the most sensitive detectors for\nheterodyne spectroscopy in the frequency range between 1.5 THz and 5 THz. To reach the ultimate receiver noise\ntemperatures in the high end of the THz range (3-6 THz), it is crucial to understand their fundamental noise contribution\nfrom different origins. With increasing frequency, the classical output noise contribution should remain unchanged, but\nthe quantum noise contribution is expected to play an increasing role [1].\nThis paper reports the first dedicated experiment using a single NbN HEB mixer at a number of local oscillator\nfrequencies between 1.6 to 4.3 THz to address and quantify the contribution of the quantum noise to the receiver noise\ntemperature.\nWe used a spiral antenna coupled NbN HEB mixer with a bolometer size of 2 μm×0.2 μm. In order to minimize\nuncertainties in the corrections of the optical losses, we use a vacuum hot/cold load setup [2] to eliminate the air loss, and\nan uncoated elliptical Si lens. Although other components, a 3 μm Mylar beam splitter and a QMC heat filter, also\nintroduce frequency dependent optical losses, they can be accurately calibrated. Furthermore, to reduce uncertainties in\nthe data, we measure Y-factors responding to the hot/cold load by fixing the voltage, but varying the LO power [2]. As\nLO, we use a FIR gas laser.\nWe measure the Y-factor at the optimal point at different frequencies by only varying LO frequencies, but keeping\nthe rest exactly the same. We obtain DSB receiver noise temperatures, which are 842 K (at 1.6 THz), 845 K (1.9 THz), 974\nK (2.5 THz) and 1372 K (4.3 THz). After the correction for the losses of the QMC filter and the beam splitter, the noise\ndata show a linear increase with increasing frequency.\nUsing a quantum noise model [1] for HEB mixers and using a criterion for which the classical output noise must be\nconstant at different frequencies, we analyze the results and find the excess quantum noise factor β to be around 2 and\nthat 24 % of the total receiver noise temperature at 4.3 THz (at the input of the entire receiver) can be ascribed to\nquantum noise. Clearly the quantum noise has a small but measurable effect on the receiver noise temperature at this\nfrequency.\nWe are still analyzing different alternatives of interpretation for the mismatch loss between the bolometer and\nthe spiral antenna.\n[1] E. L. Kollberg and K. S. Yngvesson, “Quantum-noise theory for terahertz hot electron bolometer mixers,” IEEE Trans.\nMicrowave Theory and Techniques, 54, 2077, 2006.\n[2] P. Khosropanah, J.R. Gao, W.M. Laauwen, M. Hajenius and T.M. Klapwijk, “Low noise NbN hot-electron bolometer mixer\nat 4.3 THz,” Appl. Phys. Lett., 91, 221111, 2007.\n

Related papers

Superconducting NbN hot electron bolometer mixer at terahertz

Biaobing Jin, Jianhui Chen, Min Liang +3 more

Superconducting niobium nitride (NbN) hot electron bolometer (HEB) mixers at terahertz (THz) have been designed, fabricated and measured for applications in astronomy and cosmology. The NbN HEB mixer consists of a planar antenna and an NbN bridge connecting across the antenna's inner terminals on high-resistivity Si substrates. Double sideband (DSB) receiver noise temperatures of 698 K at 0.65 THz, 904 K at 1.6 THz, 1026 K at 2.5 THz and 1386 K at 3.1 THz have been obtained at 4.2 K without corrections and using changeable input local oscillation (LO) power to eliminate the affects of direct detection and instability of the LO power. The excess quantum noise factor beta of about 4 has been estimated using a quantum noise model.

International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz)•Sep 1, 2009•0 citations

Sensitivity of a hot electron bolometer heterodyne receiver at 4.3 THz

P. Khosropanah, W. M. Laauwen, Merlijn Hajenius +2 more

We have studied the sensitivity of a superconducting NbN hot electron bolometer mixer integrated with a spiral antenna at 4.3 THz. Using hot/cold blackbody loads and a beam splitter all in vacuum, we measured a double sideband receiver noise temperature of 1300 K at the optimum local oscillator (LO) power of 330 nW, which is about 12 times the quantum noise (hν/2kB). Our result indicates that there is no sign of degradation of the mixing process at the super-THz frequencies. Also, a measurement method is introduced where the hot/cold response of the receiver is recorded at constant voltage bias of the mixer, while varying the LO power. We argue that this method provides an accurate measurement of the receiver noise temperature, which is not influenced by the LO power fluctuations and the direct detection effect. Moreover, our sensitivity data suggests that one can achieve a receiver noise temperature of 1420 K at the frequency of [OI] line (4.7 THz), which is scaled from the sensitivity at 4.3 THz with frequency.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jun 6, 2008•0 citations

Low Noise Receivers Based on Superconducting Niobium Nitride Hot Electron Bolometer Mixers from 0.65 to 3.1 Terahertz

Min Liang, Jian Chen, Lin Kang +3 more

Low noise terahertz (THz) receivers based on superconducting niobium nitride (NbN) hot electron bolometer (HEB) mixers have been designed, fabricated and measured for applications in astronomy and cosmology. The NbN HEB mixer consists of a planar antenna and an NbN bridge connecting across the antenna's inner terminals on a high-resistivity Si substrate. To eliminate the influence of direct detection and instability of the local oscillation (LO) power, a wire grid has been used to change the input LO power for compensating the shift of bias current during Y-factor measurement. The double sideband (DSB) receiver noise temperatures at 4.2K without corrections have been measured from 0.65 to 3.1THz. The excess quantum noise factor β of about 4 has been obtained, which agrees well with the calculated value. Allan variance of the HEB has been characterized, and Allan time TA longer than 0.4s is obtained. We also estimated the temperature resolution of the HEB from the Allan variance and obtained the minimum temperature resolution of 1.1K using a Gunn oscillator with its multipliers at 0.65THz as an LO source.

IEICE Transactions on Electronics•Jan 1, 2010•7 citations

Noise temperature and beam pattern of an NbN hot electron bolometer mixer at 5.25 THz

W. Zhang, P. Khosropanah, J. R. Gao +4 more

We report the measured sensitivities of a superconducting NbN hot electron bolometer (HEB) heterodyne receiver at 5.25 THz. Terahertz (THz) radiation is quasioptically coupled to a HEB mixer with a lens and a spiral antenna. Using a measurement setup with black body calibration sources and a beam splitter in vacuo, and an antireflection coated Si lens, we obtained a double sideband (DSB) receiver noise temperature (TrecDSB) of 1150 K, which is nine times hν/2k, where h is the Planck constant, ν the frequency, and k the Boltzmann constant. In addition, the measured far field beam patterns of the integrated lens antenna show nearly collimated beams from 2.5 to 5.3 THz that allow reliable measurement of TrecDSB using the vacuum setup. Our experimental results in combination with an antenna-to-bolometer coupling simulation suggest that the HEB mixer can work well at least up to 6 THz, making it suitable for next generation of high-resolution spectroscopic space telescopes and, in particular, for the detection of the neutral atomic oxygen line at 4.7 THz.

Journal of Applied Physics•Nov 1, 2010•42 citations

Reduced Noise Temperatures of a THz NbN Hot Electron Bolometer Mixer

B. Mirzaei, J. R. G. Silva, W. J. Vreeling +3 more

In this article, we measure the double sideband (DSB) receiver noise temperature ($T_{\text{rec}}^{\text{DSB}})$of an NbN hot electron bolometer (HEB) mixer at three local oscillator frequencies of 1.6, 2.5, and 5.3 THz. The HEB has cleaned contact interfaces with a 200-nm-thick Au layer. The measured$T_{\text{rec}}^{\text{DSB}}$values are 530 ± 11 K, 640 ± 18 K, and 2190 ±150 K at 1.6, 2.5, and 5.3 THz, respectively, using an air setup with total optical losses of 2.60 ± 0.04, 2.63 ± 0.16, and 4.70 ± 0.24 dB, respectively. We derived low mixer noise temperatures ($T_{\text{mixer}}^{\text{DSB}})$of 240 ± 6 K at 1.6 THz and 290 ± 13 K at 2.5 THz, achieving over 30% improvement compared to published NbN HEB mixers. This enhancement can reduce the integration time of a heterodyne instrument by roughly a factor of 2. At 5.3 THz,$T_{\text{mixer}}^{\text{DSB}}$is 620 ± 55 K, showing limited improvement due to nonoptimized antenna geometry. These results also contribute to understanding the device physics of a wide HEB (4 μm) at high frequencies. The mixer was developed for the proposed Orbiting Astronomical Satellite for Investigating Stellar Systems and Single Aperture Large Telescope for Universe Studies (concept) missions.

IEEE Transactions on Terahertz Science and Technology•Oct 7, 2024•5 citations

Quantum noise in a terahertz hot electron bolometer mixer

Wen Zhang, P. Khosropanah, J. R. Gao +5 more

We have measured the noise temperature of a single, sensitive superconducting NbN hot electron bolometer (HEB) mixer in a frequency range from 1.6 to 5.3 THz, using a setup with all the key components in vacuum. By analyzing the measured receiver noise temperature using a quantum noise (QN) model for HEB mixers, we confirm the effect of QN. The QN is found to be responsible for about half of the receiver noise at the highest frequency in our measurements. The β-factor (the quantum efficiency of the HEB) obtained experimentally agrees reasonably well with the calculated value.

Applied Physics Letters•Mar 15, 2010•80 citations
Abstract— Superconducting NbN hot electron bolometer (HEB) mixers are so far the most sensitive detectors for\nheterodyne spectroscopy in the frequency range between 1.5 THz and 5 THz. To reach the ultimate receiver noise\ntemperatures in the high end of the THz range (3-6 THz), it is crucial to understand their fundamental noise contribution\nfrom different origins. With increasing frequency, the classical output noise contribution should remain unchanged, but\nthe quantum noise contribution is expected to play an increasing role [1].\nThis paper reports the first dedicated experiment using a single NbN HEB mixer at a number of local oscillator\nfrequencies between 1.6 to 4.3 THz to address and quantify the contribution of the quantum noise to the receiver noise\ntemperature.\nWe used a spiral antenna coupled NbN HEB mixer with a bolometer size of 2 μm×0.2 μm. In order to minimize\nuncertainties in the corrections of the optical losses, we use a vacuum hot/cold load setup [2] to eliminate the air loss, and\nan uncoated elliptical Si lens. Although other components, a 3 μm Mylar beam splitter and a QMC heat filter, also\nintroduce frequency dependent optical losses, they can be accurately calibrated. Furthermore, to reduce uncertainties in\nthe data, we measure Y-factors responding to the hot/cold load by fixing the voltage, but varying the LO power [2]. As\nLO, we use a FIR gas laser.\nWe measure the Y-factor at the optimal point at different frequencies by only varying LO frequencies, but keeping\nthe rest exactly the same. We obtain DSB receiver noise temperatures, which are 842 K (at 1.6 THz), 845 K (1.9 THz), 974\nK (2.5 THz) and 1372 K (4.3 THz). After the correction for the losses of the QMC filter and the beam splitter, the noise\ndata show a linear increase with increasing frequency.\nUsing a quantum noise model [1] for HEB mixers and using a criterion for which the classical output noise must be\nconstant at different frequencies, we analyze the results and find the excess quantum noise factor β to be around 2 and\nthat 24 % of the total receiver noise temperature at 4.3 THz (at the input of the entire receiver) can be ascribed to\nquantum noise. Clearly the quantum noise has a small but measurable effect on the receiver noise temperature at this\nfrequency.\nWe are still analyzing different alternatives of interpretation for the mismatch loss between the bolometer and\nthe spiral antenna.\n[1] E. L. Kollberg and K. S. Yngvesson, “Quantum-noise theory for terahertz hot electron bolometer mixers,” IEEE Trans.\nMicrowave Theory and Techniques, 54, 2077, 2006.\n[2] P. Khosropanah, J.R. Gao, W.M. Laauwen, M. Hajenius and T.M. Klapwijk, “Low noise NbN hot-electron bolometer mixer\nat 4.3 THz,” Appl. Phys. Lett., 91, 221111, 2007.\n
Superconducting niobium nitride (NbN) hot electron bolometer (HEB) mixers at terahertz (THz) have been designed, fabricated and measured for applications in astronomy and cosmology. The NbN HEB mixer consists of a planar antenna and an NbN bridge connecting across the antenna's inner terminals on high-resistivity Si substrates. Double sideband (DSB) receiver noise temperatures of 698 K at 0.65 THz, 904 K at 1.6 THz, 1026 K at 2.5 THz and 1386 K at 3.1 THz have been obtained at 4.2 K without corrections and using changeable input local oscillation (LO) power to eliminate the affects of direct detection and instability of the LO power. The excess quantum noise factor beta of about 4 has been estimated using a quantum noise model.
We have studied the sensitivity of a superconducting NbN hot electron bolometer mixer integrated with a spiral antenna at 4.3 THz. Using hot/cold blackbody loads and a beam splitter all in vacuum, we measured a double sideband receiver noise temperature of 1300 K at the optimum local oscillator (LO) power of 330 nW, which is about 12 times the quantum noise (hν/2kB). Our result indicates that there is no sign of degradation of the mixing process at the super-THz frequencies. Also, a measurement method is introduced where the hot/cold response of the receiver is recorded at constant voltage bias of the mixer, while varying the LO power. We argue that this method provides an accurate measurement of the receiver noise temperature, which is not influenced by the LO power fluctuations and the direct detection effect. Moreover, our sensitivity data suggests that one can achieve a receiver noise temperature of 1420 K at the frequency of [OI] line (4.7 THz), which is scaled from the sensitivity at 4.3 THz with frequency.
Low noise terahertz (THz) receivers based on superconducting niobium nitride (NbN) hot electron bolometer (HEB) mixers have been designed, fabricated and measured for applications in astronomy and cosmology. The NbN HEB mixer consists of a planar antenna and an NbN bridge connecting across the antenna's inner terminals on a high-resistivity Si substrate. To eliminate the influence of direct detection and instability of the local oscillation (LO) power, a wire grid has been used to change the input LO power for compensating the shift of bias current during Y-factor measurement. The double sideband (DSB) receiver noise temperatures at 4.2K without corrections have been measured from 0.65 to 3.1THz. The excess quantum noise factor β of about 4 has been obtained, which agrees well with the calculated value. Allan variance of the HEB has been characterized, and Allan time TA longer than 0.4s is obtained. We also estimated the temperature resolution of the HEB from the Allan variance and obtained the minimum temperature resolution of 1.1K using a Gunn oscillator with its multipliers at 0.65THz as an LO source.
We report the measured sensitivities of a superconducting NbN hot electron bolometer (HEB) heterodyne receiver at 5.25 THz. Terahertz (THz) radiation is quasioptically coupled to a HEB mixer with a lens and a spiral antenna. Using a measurement setup with black body calibration sources and a beam splitter in vacuo, and an antireflection coated Si lens, we obtained a double sideband (DSB) receiver noise temperature (TrecDSB) of 1150 K, which is nine times hν/2k, where h is the Planck constant, ν the frequency, and k the Boltzmann constant. In addition, the measured far field beam patterns of the integrated lens antenna show nearly collimated beams from 2.5 to 5.3 THz that allow reliable measurement of TrecDSB using the vacuum setup. Our experimental results in combination with an antenna-to-bolometer coupling simulation suggest that the HEB mixer can work well at least up to 6 THz, making it suitable for next generation of high-resolution spectroscopic space telescopes and, in particular, for the detection of the neutral atomic oxygen line at 4.7 THz.
In this article, we measure the double sideband (DSB) receiver noise temperature (TrecDSB)T_{\text{rec}}^{\text{DSB}})TrecDSB​)of an NbN hot electron bolometer (HEB) mixer at three local oscillator frequencies of 1.6, 2.5, and 5.3 THz. The HEB has cleaned contact interfaces with a 200-nm-thick Au layer. The measuredTrecDSBT_{\text{rec}}^{\text{DSB}}TrecDSB​values are 530 ± 11 K, 640 ± 18 K, and 2190 ±150 K at 1.6, 2.5, and 5.3 THz, respectively, using an air setup with total optical losses of 2.60 ± 0.04, 2.63 ± 0.16, and 4.70 ± 0.24 dB, respectively. We derived low mixer noise temperatures (TmixerDSB)T_{\text{mixer}}^{\text{DSB}})TmixerDSB​)of 240 ± 6 K at 1.6 THz and 290 ± 13 K at 2.5 THz, achieving over 30% improvement compared to published NbN HEB mixers. This enhancement can reduce the integration time of a heterodyne instrument by roughly a factor of 2. At 5.3 THz,TmixerDSBT_{\text{mixer}}^{\text{DSB}}TmixerDSB​is 620 ± 55 K, showing limited improvement due to nonoptimized antenna geometry. These results also contribute to understanding the device physics of a wide HEB (4 μm) at high frequencies. The mixer was developed for the proposed Orbiting Astronomical Satellite for Investigating Stellar Systems and Single Aperture Large Telescope for Universe Studies (concept) missions.
We have measured the noise temperature of a single, sensitive superconducting NbN hot electron bolometer (HEB) mixer in a frequency range from 1.6 to 5.3 THz, using a setup with all the key components in vacuum. By analyzing the measured receiver noise temperature using a quantum noise (QN) model for HEB mixers, we confirm the effect of QN. The QN is found to be responsible for about half of the receiver noise at the highest frequency in our measurements. The β-factor (the quantum efficiency of the HEB) obtained experimentally agrees reasonably well with the calculated value.