Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE

Sensitivity of a hot electron bolometer heterodyne receiver at 4.3 THz

P. Khosropanah, W. M. Laauwen, Merlijn Hajenius, J. R. Gao, T. M. Klapwijk

Published Jun 6, 2008• 0 citations
Publisher

Abstract

We have studied the sensitivity of a superconducting NbN hot electron bolometer mixer integrated with a spiral antenna at 4.3 THz. Using hot/cold blackbody loads and a beam splitter all in vacuum, we measured a double sideband receiver noise temperature of 1300 K at the optimum local oscillator (LO) power of 330 nW, which is about 12 times the quantum noise (hν/2kB). Our result indicates that there is no sign of degradation of the mixing process at the super-THz frequencies. Also, a measurement method is introduced where the hot/cold response of the receiver is recorded at constant voltage bias of the mixer, while varying the LO power. We argue that this method provides an accurate measurement of the receiver noise temperature, which is not influenced by the LO power fluctuations and the direct detection effect. Moreover, our sensitivity data suggests that one can achieve a receiver noise temperature of 1420 K at the frequency of [OI] line (4.7 THz), which is scaled from the sensitivity at 4.3 THz with frequency.

DOI
10.1117/12.789387

Related papers

Low noise NbN hot electron bolometer mixer at 4.3THz

P. Khosropanah, J. R. Gao, W. M. Laauwen +2 more

We have studied the sensitivity of a superconducting NbN hot electron bolometer mixer integrated with a spiral antenna at 4.3THz. Using hot/cold blackbody loads and a beam splitter all in vacuum, we measured a double sideband receiver noise temperature of 1300K at the optimum local oscillator (LO) power of 330nW, which is about 12 times the quantum noise (hν∕2kB). Our result indicates that there is no sign of degradation of the mixing process at the superterahertz frequencies. Moreover, a measurement method is introduced which allows us for an accurate determination of the sensitivity despite LO power fluctuations.

Applied Physics Letters•Nov 26, 2007•75 citations

Noise temperature of a 4.3 THz HEB receiver

P. Khosropanah, W. M. Laauwen, J. R. Gao +3 more

We have characterized a heterodyne receiver based on an NbN hot electron bolometer integrated with spiral antenna as mixer and an optically pumped FIR ring laser at 4.3 THz as local oscillator (LO). We succeeded in measuring the receiver output power, responding to the hot/cold load, as a function of bias voltage at optimum LO power. From the resulted receiver noise temperature versus the bias voltage, we found a DSB receiver noise temperature of 3500 K at a bath temperature of 4 K, which is a minimum average value. This is the highest sensitivity reported so far at frequencies above 4 THz.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Sep 13, 2007•0 citations

Noise Temperature and Beam Pattern of a Quasioptical Heterodyne Receiver based on NbN Hot Electron Bolometer Mixer at 5.25 THz

W. Zhang, P. Khosropanah, J. R. Gao +4 more

We report the measured sensitivities of a superconducting NbN hot electron bolometer (HEB) heterodyne receiver at 5.25 THz. The terahertz (THz) radiation is quasioptically coupled to the HEB mixer with a lens and a spiral antenna. Using a measurement setup with black body calibration sources and a beam splitter in vacuum, and an antireflection coated Si lens, we obtained a double sideband (DSB) receiver noise temperature ( ) of 1150 K, which is 4.5 times h/k (the quantum limit). In addition, the measured far field beam patterns of the integrated lens antenna from 2.5 THz to 5.3 THz show collimated beams that make it reliable to measure using the vacuum setup. Our experimental results in combination with an antenna-to-bolometer coupling simulation suggest that the HEB mixer can work well at least up to 6 THz, suitable for next generation of high-resolution spectroscopic space telescopes and, in particular, for the detection of the neutral atomic oxygen (OI) line at 4.7 THz. DSB rec T

Softwaretechnik-Trends•Mar 1, 2010•0 citations

Noise temperature and beam pattern of an NbN hot electron bolometer mixer at 5.25 THz

W. Zhang, P. Khosropanah, J. R. Gao +4 more

We report the measured sensitivities of a superconducting NbN hot electron bolometer (HEB) heterodyne receiver at 5.25 THz. Terahertz (THz) radiation is quasioptically coupled to a HEB mixer with a lens and a spiral antenna. Using a measurement setup with black body calibration sources and a beam splitter in vacuo, and an antireflection coated Si lens, we obtained a double sideband (DSB) receiver noise temperature (TrecDSB) of 1150 K, which is nine times hν/2k, where h is the Planck constant, ν the frequency, and k the Boltzmann constant. In addition, the measured far field beam patterns of the integrated lens antenna show nearly collimated beams from 2.5 to 5.3 THz that allow reliable measurement of TrecDSB using the vacuum setup. Our experimental results in combination with an antenna-to-bolometer coupling simulation suggest that the HEB mixer can work well at least up to 6 THz, making it suitable for next generation of high-resolution spectroscopic space telescopes and, in particular, for the detection of the neutral atomic oxygen line at 4.7 THz.

Journal of Applied Physics•Nov 1, 2010•42 citations

NbN hot electron bolometer mixer at 5.3 THz

Wen Zhang, J. R. Gao, P. Khosropanah +4 more

We report the sensitivity of a superconducting NbN hot electron bolometer mixer integrated with a tight spiral antenna at 5.3 THz. Using a measurement setup with black body calibration sources and a beam splitter in vacuo, and an antireflection coated Si lens, we obtained a double sideband receiver noise temperature of 1150 K, which is 4.5 times hν/kB (quantum limit). Our experimental results in combination with an antenna-to-bolometer coupling simulation suggest that HEB mixer can work well at least up to 6 THz, suitable for next generation of high-resolution spectroscopic of the neutral atomic oxygen (OI) line at 4.7 THz.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jun 16, 2010•1 citation

Quantum noise contribution to NbN hot electron bolometer receiver

E. Kollberg, P. Khosropanah, Wen Zhang +4 more

Abstract— Superconducting NbN hot electron bolometer (HEB) mixers are so far the most sensitive detectors for\nheterodyne spectroscopy in the frequency range between 1.5 THz and 5 THz. To reach the ultimate receiver noise\ntemperatures in the high end of the THz range (3-6 THz), it is crucial to understand their fundamental noise contribution\nfrom different origins. With increasing frequency, the classical output noise contribution should remain unchanged, but\nthe quantum noise contribution is expected to play an increasing role [1].\nThis paper reports the first dedicated experiment using a single NbN HEB mixer at a number of local oscillator\nfrequencies between 1.6 to 4.3 THz to address and quantify the contribution of the quantum noise to the receiver noise\ntemperature.\nWe used a spiral antenna coupled NbN HEB mixer with a bolometer size of 2 μm×0.2 μm. In order to minimize\nuncertainties in the corrections of the optical losses, we use a vacuum hot/cold load setup [2] to eliminate the air loss, and\nan uncoated elliptical Si lens. Although other components, a 3 μm Mylar beam splitter and a QMC heat filter, also\nintroduce frequency dependent optical losses, they can be accurately calibrated. Furthermore, to reduce uncertainties in\nthe data, we measure Y-factors responding to the hot/cold load by fixing the voltage, but varying the LO power [2]. As\nLO, we use a FIR gas laser.\nWe measure the Y-factor at the optimal point at different frequencies by only varying LO frequencies, but keeping\nthe rest exactly the same. We obtain DSB receiver noise temperatures, which are 842 K (at 1.6 THz), 845 K (1.9 THz), 974\nK (2.5 THz) and 1372 K (4.3 THz). After the correction for the losses of the QMC filter and the beam splitter, the noise\ndata show a linear increase with increasing frequency.\nUsing a quantum noise model [1] for HEB mixers and using a criterion for which the classical output noise must be\nconstant at different frequencies, we analyze the results and find the excess quantum noise factor β to be around 2 and\nthat 24 % of the total receiver noise temperature at 4.3 THz (at the input of the entire receiver) can be ascribed to\nquantum noise. Clearly the quantum noise has a small but measurable effect on the receiver noise temperature at this\nfrequency.\nWe are still analyzing different alternatives of interpretation for the mismatch loss between the bolometer and\nthe spiral antenna.\n[1] E. L. Kollberg and K. S. Yngvesson, “Quantum-noise theory for terahertz hot electron bolometer mixers,” IEEE Trans.\nMicrowave Theory and Techniques, 54, 2077, 2006.\n[2] P. Khosropanah, J.R. Gao, W.M. Laauwen, M. Hajenius and T.M. Klapwijk, “Low noise NbN hot-electron bolometer mixer\nat 4.3 THz,” Appl. Phys. Lett., 91, 221111, 2007.\n

•Jan 1, 2009•0 citations
We have studied the sensitivity of a superconducting NbN hot electron bolometer mixer integrated with a spiral antenna at 4.3 THz. Using hot/cold blackbody loads and a beam splitter all in vacuum, we measured a double sideband receiver noise temperature of 1300 K at the optimum local oscillator (LO) power of 330 nW, which is about 12 times the quantum noise (hν/2kB). Our result indicates that there is no sign of degradation of the mixing process at the super-THz frequencies. Also, a measurement method is introduced where the hot/cold response of the receiver is recorded at constant voltage bias of the mixer, while varying the LO power. We argue that this method provides an accurate measurement of the receiver noise temperature, which is not influenced by the LO power fluctuations and the direct detection effect. Moreover, our sensitivity data suggests that one can achieve a receiver noise temperature of 1420 K at the frequency of [OI] line (4.7 THz), which is scaled from the sensitivity at 4.3 THz with frequency.
We have studied the sensitivity of a superconducting NbN hot electron bolometer mixer integrated with a spiral antenna at 4.3THz. Using hot/cold blackbody loads and a beam splitter all in vacuum, we measured a double sideband receiver noise temperature of 1300K at the optimum local oscillator (LO) power of 330nW, which is about 12 times the quantum noise (hν∕2kB). Our result indicates that there is no sign of degradation of the mixing process at the superterahertz frequencies. Moreover, a measurement method is introduced which allows us for an accurate determination of the sensitivity despite LO power fluctuations.
We have characterized a heterodyne receiver based on an NbN hot electron bolometer integrated with spiral antenna as mixer and an optically pumped FIR ring laser at 4.3 THz as local oscillator (LO). We succeeded in measuring the receiver output power, responding to the hot/cold load, as a function of bias voltage at optimum LO power. From the resulted receiver noise temperature versus the bias voltage, we found a DSB receiver noise temperature of 3500 K at a bath temperature of 4 K, which is a minimum average value. This is the highest sensitivity reported so far at frequencies above 4 THz.
We report the measured sensitivities of a superconducting NbN hot electron bolometer (HEB) heterodyne receiver at 5.25 THz. The terahertz (THz) radiation is quasioptically coupled to the HEB mixer with a lens and a spiral antenna. Using a measurement setup with black body calibration sources and a beam splitter in vacuum, and an antireflection coated Si lens, we obtained a double sideband (DSB) receiver noise temperature ( ) of 1150 K, which is 4.5 times h/k (the quantum limit). In addition, the measured far field beam patterns of the integrated lens antenna from 2.5 THz to 5.3 THz show collimated beams that make it reliable to measure using the vacuum setup. Our experimental results in combination with an antenna-to-bolometer coupling simulation suggest that the HEB mixer can work well at least up to 6 THz, suitable for next generation of high-resolution spectroscopic space telescopes and, in particular, for the detection of the neutral atomic oxygen (OI) line at 4.7 THz. DSB rec T
We report the measured sensitivities of a superconducting NbN hot electron bolometer (HEB) heterodyne receiver at 5.25 THz. Terahertz (THz) radiation is quasioptically coupled to a HEB mixer with a lens and a spiral antenna. Using a measurement setup with black body calibration sources and a beam splitter in vacuo, and an antireflection coated Si lens, we obtained a double sideband (DSB) receiver noise temperature (TrecDSB) of 1150 K, which is nine times hν/2k, where h is the Planck constant, ν the frequency, and k the Boltzmann constant. In addition, the measured far field beam patterns of the integrated lens antenna show nearly collimated beams from 2.5 to 5.3 THz that allow reliable measurement of TrecDSB using the vacuum setup. Our experimental results in combination with an antenna-to-bolometer coupling simulation suggest that the HEB mixer can work well at least up to 6 THz, making it suitable for next generation of high-resolution spectroscopic space telescopes and, in particular, for the detection of the neutral atomic oxygen line at 4.7 THz.
We report the sensitivity of a superconducting NbN hot electron bolometer mixer integrated with a tight spiral antenna at 5.3 THz. Using a measurement setup with black body calibration sources and a beam splitter in vacuo, and an antireflection coated Si lens, we obtained a double sideband receiver noise temperature of 1150 K, which is 4.5 times hν/kB (quantum limit). Our experimental results in combination with an antenna-to-bolometer coupling simulation suggest that HEB mixer can work well at least up to 6 THz, suitable for next generation of high-resolution spectroscopic of the neutral atomic oxygen (OI) line at 4.7 THz.
Abstract— Superconducting NbN hot electron bolometer (HEB) mixers are so far the most sensitive detectors for\nheterodyne spectroscopy in the frequency range between 1.5 THz and 5 THz. To reach the ultimate receiver noise\ntemperatures in the high end of the THz range (3-6 THz), it is crucial to understand their fundamental noise contribution\nfrom different origins. With increasing frequency, the classical output noise contribution should remain unchanged, but\nthe quantum noise contribution is expected to play an increasing role [1].\nThis paper reports the first dedicated experiment using a single NbN HEB mixer at a number of local oscillator\nfrequencies between 1.6 to 4.3 THz to address and quantify the contribution of the quantum noise to the receiver noise\ntemperature.\nWe used a spiral antenna coupled NbN HEB mixer with a bolometer size of 2 μm×0.2 μm. In order to minimize\nuncertainties in the corrections of the optical losses, we use a vacuum hot/cold load setup [2] to eliminate the air loss, and\nan uncoated elliptical Si lens. Although other components, a 3 μm Mylar beam splitter and a QMC heat filter, also\nintroduce frequency dependent optical losses, they can be accurately calibrated. Furthermore, to reduce uncertainties in\nthe data, we measure Y-factors responding to the hot/cold load by fixing the voltage, but varying the LO power [2]. As\nLO, we use a FIR gas laser.\nWe measure the Y-factor at the optimal point at different frequencies by only varying LO frequencies, but keeping\nthe rest exactly the same. We obtain DSB receiver noise temperatures, which are 842 K (at 1.6 THz), 845 K (1.9 THz), 974\nK (2.5 THz) and 1372 K (4.3 THz). After the correction for the losses of the QMC filter and the beam splitter, the noise\ndata show a linear increase with increasing frequency.\nUsing a quantum noise model [1] for HEB mixers and using a criterion for which the classical output noise must be\nconstant at different frequencies, we analyze the results and find the excess quantum noise factor β to be around 2 and\nthat 24 % of the total receiver noise temperature at 4.3 THz (at the input of the entire receiver) can be ascribed to\nquantum noise. Clearly the quantum noise has a small but measurable effect on the receiver noise temperature at this\nfrequency.\nWe are still analyzing different alternatives of interpretation for the mismatch loss between the bolometer and\nthe spiral antenna.\n[1] E. L. Kollberg and K. S. Yngvesson, “Quantum-noise theory for terahertz hot electron bolometer mixers,” IEEE Trans.\nMicrowave Theory and Techniques, 54, 2077, 2006.\n[2] P. Khosropanah, J.R. Gao, W.M. Laauwen, M. Hajenius and T.M. Klapwijk, “Low noise NbN hot-electron bolometer mixer\nat 4.3 THz,” Appl. Phys. Lett., 91, 221111, 2007.\n