Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics Letters

Quantum noise in a terahertz hot electron bolometer mixer

Wen Zhang, P. Khosropanah, J. R. Gao, E. Kollberg, K. S. Yngvesson, Tarun Bansal, R. Barends, T. M. Klapwijk

Published Mar 15, 2010• 80 citations
Publisher

Abstract

We have measured the noise temperature of a single, sensitive superconducting NbN hot electron bolometer (HEB) mixer in a frequency range from 1.6 to 5.3 THz, using a setup with all the key components in vacuum. By analyzing the measured receiver noise temperature using a quantum noise (QN) model for HEB mixers, we confirm the effect of QN. The QN is found to be responsible for about half of the receiver noise at the highest frequency in our measurements. The β-factor (the quantum efficiency of the HEB) obtained experimentally agrees reasonably well with the calculated value.

DOI
10.1063/1.3364936

Related papers

Quantum noise contribution to NbN hot electron bolometer receiver

E. Kollberg, P. Khosropanah, Wen Zhang +4 more

Abstract— Superconducting NbN hot electron bolometer (HEB) mixers are so far the most sensitive detectors for\nheterodyne spectroscopy in the frequency range between 1.5 THz and 5 THz. To reach the ultimate receiver noise\ntemperatures in the high end of the THz range (3-6 THz), it is crucial to understand their fundamental noise contribution\nfrom different origins. With increasing frequency, the classical output noise contribution should remain unchanged, but\nthe quantum noise contribution is expected to play an increasing role [1].\nThis paper reports the first dedicated experiment using a single NbN HEB mixer at a number of local oscillator\nfrequencies between 1.6 to 4.3 THz to address and quantify the contribution of the quantum noise to the receiver noise\ntemperature.\nWe used a spiral antenna coupled NbN HEB mixer with a bolometer size of 2 μm×0.2 μm. In order to minimize\nuncertainties in the corrections of the optical losses, we use a vacuum hot/cold load setup [2] to eliminate the air loss, and\nan uncoated elliptical Si lens. Although other components, a 3 μm Mylar beam splitter and a QMC heat filter, also\nintroduce frequency dependent optical losses, they can be accurately calibrated. Furthermore, to reduce uncertainties in\nthe data, we measure Y-factors responding to the hot/cold load by fixing the voltage, but varying the LO power [2]. As\nLO, we use a FIR gas laser.\nWe measure the Y-factor at the optimal point at different frequencies by only varying LO frequencies, but keeping\nthe rest exactly the same. We obtain DSB receiver noise temperatures, which are 842 K (at 1.6 THz), 845 K (1.9 THz), 974\nK (2.5 THz) and 1372 K (4.3 THz). After the correction for the losses of the QMC filter and the beam splitter, the noise\ndata show a linear increase with increasing frequency.\nUsing a quantum noise model [1] for HEB mixers and using a criterion for which the classical output noise must be\nconstant at different frequencies, we analyze the results and find the excess quantum noise factor β to be around 2 and\nthat 24 % of the total receiver noise temperature at 4.3 THz (at the input of the entire receiver) can be ascribed to\nquantum noise. Clearly the quantum noise has a small but measurable effect on the receiver noise temperature at this\nfrequency.\nWe are still analyzing different alternatives of interpretation for the mismatch loss between the bolometer and\nthe spiral antenna.\n[1] E. L. Kollberg and K. S. Yngvesson, “Quantum-noise theory for terahertz hot electron bolometer mixers,” IEEE Trans.\nMicrowave Theory and Techniques, 54, 2077, 2006.\n[2] P. Khosropanah, J.R. Gao, W.M. Laauwen, M. Hajenius and T.M. Klapwijk, “Low noise NbN hot-electron bolometer mixer\nat 4.3 THz,” Appl. Phys. Lett., 91, 221111, 2007.\n

•Jan 1, 2009•0 citations

Low Noise Receivers Based on Superconducting Niobium Nitride Hot Electron Bolometer Mixers from 0.65 to 3.1 Terahertz

Min Liang, Jian Chen, Lin Kang +3 more

Low noise terahertz (THz) receivers based on superconducting niobium nitride (NbN) hot electron bolometer (HEB) mixers have been designed, fabricated and measured for applications in astronomy and cosmology. The NbN HEB mixer consists of a planar antenna and an NbN bridge connecting across the antenna's inner terminals on a high-resistivity Si substrate. To eliminate the influence of direct detection and instability of the local oscillation (LO) power, a wire grid has been used to change the input LO power for compensating the shift of bias current during Y-factor measurement. The double sideband (DSB) receiver noise temperatures at 4.2K without corrections have been measured from 0.65 to 3.1THz. The excess quantum noise factor β of about 4 has been obtained, which agrees well with the calculated value. Allan variance of the HEB has been characterized, and Allan time TA longer than 0.4s is obtained. We also estimated the temperature resolution of the HEB from the Allan variance and obtained the minimum temperature resolution of 1.1K using a Gunn oscillator with its multipliers at 0.65THz as an LO source.

IEICE Transactions on Electronics•Jan 1, 2010•7 citations

Superconducting NbN hot electron bolometer mixer at terahertz

Biaobing Jin, Jianhui Chen, Min Liang +3 more

Superconducting niobium nitride (NbN) hot electron bolometer (HEB) mixers at terahertz (THz) have been designed, fabricated and measured for applications in astronomy and cosmology. The NbN HEB mixer consists of a planar antenna and an NbN bridge connecting across the antenna's inner terminals on high-resistivity Si substrates. Double sideband (DSB) receiver noise temperatures of 698 K at 0.65 THz, 904 K at 1.6 THz, 1026 K at 2.5 THz and 1386 K at 3.1 THz have been obtained at 4.2 K without corrections and using changeable input local oscillation (LO) power to eliminate the affects of direct detection and instability of the LO power. The excess quantum noise factor beta of about 4 has been estimated using a quantum noise model.

International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz)•Sep 1, 2009•0 citations

Noise performance of quasioptical ultrathin NbN hot-electron bolometer mixer at 2.5 and 3.8 THz

Sergey V. Antipov, Yu.B. Vachtornin, S. N. Maslennikov +5 more

To put space-based and airborne heterodyne instruments into operation at frequencies above 1 THz the superconducting NbN hot-electron bolometer (HEB) will be incorporated into heterodyne receiver as a mixer. At frequencies above 1.3 THz the sensitivity of the NbN HEB mixers outperform the one of the Schottky diodes and SIS-mixers, and the receiver noise temperature of the NbN HEB mixers increase with frequency. In this paper we present the results of the noise temperature measurements within one batch of NbN HEB mixers based on 3.5 mn thick superconducting NbN film grown on Si substrate with MgO buffer layer at the LO frequencies 2.5 THz and 3.8 THz.

International Kharkiv Symposium on Physics and Engineering of Microwaves, Millimeter and Submillimeter Waves•Oct 26, 2004•0 citations

Prop erties of Terahertz Superconducting Hot Electron Bolometer Mixers

J. Chen, Biao Jin, Weizong Xu +3 more

A quasi-optical superconducting niobium nitride (NbN) hot electron bolometer (HEB) mixer has been fabricated and measured in the terahertz (THz) frequency range of 0.5~2.52 THz. A receiver noise temperature of 2000 K at 2.52 THz has been obtained for the mixer without corrections. Also, the effect of a Parylene C anti-reflection (AR) coating on the silicon (Si) lens has been studied.

•Jan 1, 2008•3 citations

Noise Behaviour of a THz Superconducting Hot-Electron Bolometer Mixer

Wen Zhang, Ning Li, Ling Jiang +11 more

A quasi-optical superconducting NbN hot-electron bolometer (HEB) mixer is measured in the frequency range of 0.5–2.5 THz for understanding of the frequency dependence of noise temperature of THz coherent detectors. It has been found that noise temperature increasing with frequency is mainly due to the coupling loss between the quasi-optical planar antenna and the superconducting HEB bridge when taking account of non-uniform distribution of high-frequency current. With the coupling loss corrected, the superconducting HEB mixer demonstrates a noise temperature nearly independent of frequency.

Chinese Physics Letters•Jun 1, 2007•8 citations
We have measured the noise temperature of a single, sensitive superconducting NbN hot electron bolometer (HEB) mixer in a frequency range from 1.6 to 5.3 THz, using a setup with all the key components in vacuum. By analyzing the measured receiver noise temperature using a quantum noise (QN) model for HEB mixers, we confirm the effect of QN. The QN is found to be responsible for about half of the receiver noise at the highest frequency in our measurements. The β-factor (the quantum efficiency of the HEB) obtained experimentally agrees reasonably well with the calculated value.
Abstract— Superconducting NbN hot electron bolometer (HEB) mixers are so far the most sensitive detectors for\nheterodyne spectroscopy in the frequency range between 1.5 THz and 5 THz. To reach the ultimate receiver noise\ntemperatures in the high end of the THz range (3-6 THz), it is crucial to understand their fundamental noise contribution\nfrom different origins. With increasing frequency, the classical output noise contribution should remain unchanged, but\nthe quantum noise contribution is expected to play an increasing role [1].\nThis paper reports the first dedicated experiment using a single NbN HEB mixer at a number of local oscillator\nfrequencies between 1.6 to 4.3 THz to address and quantify the contribution of the quantum noise to the receiver noise\ntemperature.\nWe used a spiral antenna coupled NbN HEB mixer with a bolometer size of 2 μm×0.2 μm. In order to minimize\nuncertainties in the corrections of the optical losses, we use a vacuum hot/cold load setup [2] to eliminate the air loss, and\nan uncoated elliptical Si lens. Although other components, a 3 μm Mylar beam splitter and a QMC heat filter, also\nintroduce frequency dependent optical losses, they can be accurately calibrated. Furthermore, to reduce uncertainties in\nthe data, we measure Y-factors responding to the hot/cold load by fixing the voltage, but varying the LO power [2]. As\nLO, we use a FIR gas laser.\nWe measure the Y-factor at the optimal point at different frequencies by only varying LO frequencies, but keeping\nthe rest exactly the same. We obtain DSB receiver noise temperatures, which are 842 K (at 1.6 THz), 845 K (1.9 THz), 974\nK (2.5 THz) and 1372 K (4.3 THz). After the correction for the losses of the QMC filter and the beam splitter, the noise\ndata show a linear increase with increasing frequency.\nUsing a quantum noise model [1] for HEB mixers and using a criterion for which the classical output noise must be\nconstant at different frequencies, we analyze the results and find the excess quantum noise factor β to be around 2 and\nthat 24 % of the total receiver noise temperature at 4.3 THz (at the input of the entire receiver) can be ascribed to\nquantum noise. Clearly the quantum noise has a small but measurable effect on the receiver noise temperature at this\nfrequency.\nWe are still analyzing different alternatives of interpretation for the mismatch loss between the bolometer and\nthe spiral antenna.\n[1] E. L. Kollberg and K. S. Yngvesson, “Quantum-noise theory for terahertz hot electron bolometer mixers,” IEEE Trans.\nMicrowave Theory and Techniques, 54, 2077, 2006.\n[2] P. Khosropanah, J.R. Gao, W.M. Laauwen, M. Hajenius and T.M. Klapwijk, “Low noise NbN hot-electron bolometer mixer\nat 4.3 THz,” Appl. Phys. Lett., 91, 221111, 2007.\n
Low noise terahertz (THz) receivers based on superconducting niobium nitride (NbN) hot electron bolometer (HEB) mixers have been designed, fabricated and measured for applications in astronomy and cosmology. The NbN HEB mixer consists of a planar antenna and an NbN bridge connecting across the antenna's inner terminals on a high-resistivity Si substrate. To eliminate the influence of direct detection and instability of the local oscillation (LO) power, a wire grid has been used to change the input LO power for compensating the shift of bias current during Y-factor measurement. The double sideband (DSB) receiver noise temperatures at 4.2K without corrections have been measured from 0.65 to 3.1THz. The excess quantum noise factor β of about 4 has been obtained, which agrees well with the calculated value. Allan variance of the HEB has been characterized, and Allan time TA longer than 0.4s is obtained. We also estimated the temperature resolution of the HEB from the Allan variance and obtained the minimum temperature resolution of 1.1K using a Gunn oscillator with its multipliers at 0.65THz as an LO source.
Superconducting niobium nitride (NbN) hot electron bolometer (HEB) mixers at terahertz (THz) have been designed, fabricated and measured for applications in astronomy and cosmology. The NbN HEB mixer consists of a planar antenna and an NbN bridge connecting across the antenna's inner terminals on high-resistivity Si substrates. Double sideband (DSB) receiver noise temperatures of 698 K at 0.65 THz, 904 K at 1.6 THz, 1026 K at 2.5 THz and 1386 K at 3.1 THz have been obtained at 4.2 K without corrections and using changeable input local oscillation (LO) power to eliminate the affects of direct detection and instability of the LO power. The excess quantum noise factor beta of about 4 has been estimated using a quantum noise model.
To put space-based and airborne heterodyne instruments into operation at frequencies above 1 THz the superconducting NbN hot-electron bolometer (HEB) will be incorporated into heterodyne receiver as a mixer. At frequencies above 1.3 THz the sensitivity of the NbN HEB mixers outperform the one of the Schottky diodes and SIS-mixers, and the receiver noise temperature of the NbN HEB mixers increase with frequency. In this paper we present the results of the noise temperature measurements within one batch of NbN HEB mixers based on 3.5 mn thick superconducting NbN film grown on Si substrate with MgO buffer layer at the LO frequencies 2.5 THz and 3.8 THz.
A quasi-optical superconducting NbN hot-electron bolometer (HEB) mixer is measured in the frequency range of 0.5–2.5 THz for understanding of the frequency dependence of noise temperature of THz coherent detectors. It has been found that noise temperature increasing with frequency is mainly due to the coupling loss between the quasi-optical planar antenna and the superconducting HEB bridge when taking account of non-uniform distribution of high-frequency current. With the coupling loss corrected, the superconducting HEB mixer demonstrates a noise temperature nearly independent of frequency.