Stability measurements of an NbN HEB receiver at THz frequencies

Therese Berg, Serguei Cherednichenko, Vladimir Drakinskiy, H. Merkel, E. Kollberg, J. Kooi

Published Jan 1, 2004• 4 citations
OpenAlex

Related papers

Development of NbN Terahertz, HEB Mixer Devices and Films

Eyal Gerecht, Ashok K. Bhupathiraju, John Nicholson +6 more

•Apr 1, 2003•2 citations

The bias II feedback system: Understanding and improving stability in NbN HEB Terahertz receivers

Ric Zannoni, K. S. Yngvesson

Terahertz NbN heterodyne hot electron bolometer (HEB) mixer receivers currently provide the lowest receiver noise temperatures from about 1.2 THz to 5 THz. However, it has been well documented that these receivers are less stable, as quantified by the Allan variance, than other THz receivers (SIS and Schottky barrier diode mixers). In this paper we directly address the intermediate frequency (IF) stability of (HEB) receivers by designing and implementing a feedback system to stabilize the bias of the HEB device. We report a continuum Allan time of at least 20 seconds for a THz NbN HEB receiver.

International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz)•Sep 1, 2008•1 citation

Noise performance of quasioptical ultrathin NbN hot-electron bolometer mixer at 2.5 and 3.8 THz

Sergey V. Antipov, Yu.B. Vachtornin, S. N. Maslennikov +5 more

To put space-based and airborne heterodyne instruments into operation at frequencies above 1 THz the superconducting NbN hot-electron bolometer (HEB) will be incorporated into heterodyne receiver as a mixer. At frequencies above 1.3 THz the sensitivity of the NbN HEB mixers outperform the one of the Schottky diodes and SIS-mixers, and the receiver noise temperature of the NbN HEB mixers increase with frequency. In this paper we present the results of the noise temperature measurements within one batch of NbN HEB mixers based on 3.5 mn thick superconducting NbN film grown on Si substrate with MgO buffer layer at the LO frequencies 2.5 THz and 3.8 THz.

International Kharkiv Symposium on Physics and Engineering of Microwaves, Millimeter and Submillimeter Waves•Oct 26, 2004•0 citations

Terahertz heterodyne array based on NbN HEB mixers

Serguei Cherednichenko, Vladimir Drakinskiy, B. Lecomte +7 more

•Apr 1, 2008•0 citations

NbN phonon-cooled hot-electron bolometer as a mixer for THz heterodyne receivers

H.-W. Huebers, Josef Schubert, Alexei D. Semenov +4 more

We have investigated a phonon-cooled NbN hot electron bolometric (HEB) mixer in the frequency range from 0.7 THz to 5.2 THz. The device was a 3.5 nm thin film with an in- plane dimension of 1.7 X 0.2 micrometers 2 integrated in a complementary logarithmic spiral antenna. The measured DSB receiver noise temperatures are 1500 K, 2200 K, 2600 K, 2900 K, 4000 K, 5600 K and 8800 K. The sensitivity fluctuation, the long term stability, and the antenna pattern were measured and the suitability of the mixer for a practical heterodyne receiver is discussed.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Sep 9, 1999•2 citations

Sensitivity of an NbN hot electron bolometer based heterodyne receiver at 4.3 THz

P. Khosropanah, W. M. Laauwen, J. R. Gao +3 more

•Jan 1, 2007•0 citations
Terahertz NbN heterodyne hot electron bolometer (HEB) mixer receivers currently provide the lowest receiver noise temperatures from about 1.2 THz to 5 THz. However, it has been well documented that these receivers are less stable, as quantified by the Allan variance, than other THz receivers (SIS and Schottky barrier diode mixers). In this paper we directly address the intermediate frequency (IF) stability of (HEB) receivers by designing and implementing a feedback system to stabilize the bias of the HEB device. We report a continuum Allan time of at least 20 seconds for a THz NbN HEB receiver.
To put space-based and airborne heterodyne instruments into operation at frequencies above 1 THz the superconducting NbN hot-electron bolometer (HEB) will be incorporated into heterodyne receiver as a mixer. At frequencies above 1.3 THz the sensitivity of the NbN HEB mixers outperform the one of the Schottky diodes and SIS-mixers, and the receiver noise temperature of the NbN HEB mixers increase with frequency. In this paper we present the results of the noise temperature measurements within one batch of NbN HEB mixers based on 3.5 mn thick superconducting NbN film grown on Si substrate with MgO buffer layer at the LO frequencies 2.5 THz and 3.8 THz.
We have investigated a phonon-cooled NbN hot electron bolometric (HEB) mixer in the frequency range from 0.7 THz to 5.2 THz. The device was a 3.5 nm thin film with an in- plane dimension of 1.7 X 0.2 micrometers 2 integrated in a complementary logarithmic spiral antenna. The measured DSB receiver noise temperatures are 1500 K, 2200 K, 2600 K, 2900 K, 4000 K, 5600 K and 8800 K. The sensitivity fluctuation, the long term stability, and the antenna pattern were measured and the suitability of the mixer for a practical heterodyne receiver is discussed.