RF-Interrogated End-State Chip-Scale Atomic Clock

Alan M. Braun, Timothy J. Davis, Martin H. Kwakernaak, J. J. Michalchuk, A. Ulmer, W. K. Chan, Joseph H. Abeles, Zane A. Shellenbarger, Yuan‐Yu Jau, W. Happer, T. McClelland, Hugo Fruehauf, R. Drap, W. Weidemann, M. Variakojis

Published Nov 29, 2007• 19 citations
OpenAlex

Abstract

A chip-scale atomic clock implemented with end-state physics has been fabricated and characterized. Batch-fabricated components were specifically designed and developed to enable integration within a small form-factor package. The full physics package, implemented with CW VCSEL optical pump, direct end-state hyperfine RF and Zeeman interrogation for magnetic field stabilization, was demonstrated within a 4 cm3 volume, consuming 25 mW of power, and exhibiting an Allan deviation stability. In addition, end-state signal contrast exceeded 40% from millimeter-scale vapor cells with buffer-gas pressures exceeding 2.5 atmospheres, demonstrating the route to submillimeter vapor-cells within high-performance CSACs for high shock/vibration environments.

Related papers

Components for Batch-Fabricated Chip-Scale Atomic Clocks

Martin H. Kwakernaak, Steven A. Lipp, Stacy A. McBride +7 more

We describe chip-scale batch-fabricated cesium cells utilizing semiconductor wafer processing, pin transfer of cesium, and silicon/Pyrex anodic bonding for cell sealing. Highspeed, single-mode linearly polarized VCSELs emitting at the 133Cs D1 line were fabricated, optimized for low threshold and high-speed operation with overall small power dissipation. Coherent population trapping (CPT) end-resonance signals with a contrast and linewidth of 5.4% and 7.1 kHz respectively are achieved using 1 mm optical path length cells and VCSEL driven with 1.25 mW RF modulation and 2.76 mW DC power dissipation. We demonstrate short-term stability with an atomic clock built with these components operating on the CPT end-resonance. The magnetic field is stabilized with a novel magnetic field locking scheme tapping the Zeeman resonance.

•Dec 1, 2004•7 citations

The Chip-Scale Atomic Clock - Recent Development Progress

Robert Lutwak, Donald A. Emmons, Thomas C. English +1 more

We have undertaken the development of a chip-scale atomic clock (CSAC) whose design goals include short-term stability, sigma(sub y)(tau=1 hour), of 1x10(exp 11) with a total power consumption of 30 mW and an overall device volume of 1 cu cm. The stringent power requirement dominates the physics package architecture, dictating a small (<5 mm(exp 3) gaseous atomic ensemble interrogated by a low-power semiconductor laser. At PTTI 2002, we reported on initial experimental investigations leading to the decision to employ the coherent population trapping (CPT) interrogation technique. This paper describes our further progress on the CSAC effort, including the development of custom vertical cavity surface emitting laser (VCSEL) sources and techniques for microfabricating miniature cesium vapor cells comprised of anodically bonded silicon and glass. Measurements of the signal contrast and linewidth of both the cesium D1 and D2 resonance transitions are compared, and frequency stability measurements of the CSAC testbed are presented.

•Sep 1, 2004•71 citations

Integrated physics package of a chip-scale atomic clock

Shao-Liang Li, Jing Chao Xu, Zhiqiang Zhang +3 more

The physics package of a chip-scale atomic clock (CSAC) has been successfully realized by integrating vertical cavity surface emitting laser (VCSEL), neutral density (ND) filter, λ/4 wave plate, 87 Rb vapor cell, photodiode (PD), and magnetic coil into a cuboid metal package with a volume of about 2.8 cm 3 . In this physics package, the critical component, 87 Rb vapor cell, is batch-fabricated based on MEMS technology and in-situ chemical reaction method. Pt heater and thermistors are integrated in the physics package. A PTFE pillar is used to support the optical elements in the physics package, in order to reduce the power dissipation. The optical absorption spectrum of 87 Rb D1 line and the microwave frequency correction signal are successfully observed while connecting the package with the servo circuit system. Using the above mentioned packaging solution, a CSAC with short-term frequency stability of about 7 × 10 −10 τ −1/2 has been successfully achieved, which demonstrates that this physics package would become one promising solution for the CSAC.

Chinese Physics B•Jul 1, 2014•17 citations

Long-Term Stability of NIST Chip-Scale Atomic Clock Physics Packages

Svenja A. Knappe, Vishal Shah, Vladislav P. Gerginov +3 more

We present measurements regarding the long-term frequency stability of NIST chip-scale atomic clock (CSAC) physics packages. Changes of the clock frequency are caused mainly through time-dependent light shifts by the frequency-modulated VCSEL and properties of the vapor cell. We suggest advanced CPT interrogation schemes to relax the requirements on the temperature stability of the VCSEL as well as the power of the local oscillator. Finally, we discuss the advantages and limitations of these techniques when implemented into a small package.

•Dec 9, 2006•6 citations

The Chip-Scale Atomic Clock - Low-Power Physics Package

Robert Lutwak, Jinyi Deng, William Riley +7 more

We have undertaken a development effort to produce a prototype chip-scale atomic clock (CSAC). The design goals include short-term stability, with a total power consumption of less than 30 mW and overall device volume <1 cubic cm. The stringent power requirement dominates the physics package architecture, necessarily dictating a small volume gaseous atomic ensemble interrogated by a low-power semiconductor laser. At PTTI 2002 and PTTI 2003, we reported on laboratory experiments that underlie the fundamental architecture of our CSAC, based on interrogation of the cesium D1 transition by the technique of coherent population trapping (CPT). In the past year, the development effort has shifted from fundamental research and feasibility investigation to engineering and prototype development. In this paper, we report on the design of a rugged and compact physics package that is expected to exceed the ultimate performance and power requirements of the CSAC.

•Dec 1, 2004•79 citations

Next-Generation Chip Scale Atomic Clocks

John E. Kitching, Matthew T. Hummon, William McGehee +2 more

We describe three independent research directions focussed on the development of next-generation chip-scale atomic clocks, which combine small size, low power consumption and manufacturability with high frequency stability. The use of optical transitions in microfabricated vapor cells improves both short- and long-term frequency stability to near 10−13 at the cost of the added complexity of a chip-scale optical frequency comb. Chip-scale atomic beam microwave clocks have been successfully demonstrated and offer the potential for microsecond-level timing accuracy over one week. And finally, Sr vapor cells have been developed with lifetimes exceeding 250 hours and residual gas pressures below 1 Torr.

Journal of Physics Conference Series•Nov 1, 2024•12 citations
A chip-scale atomic clock implemented with end-state physics has been fabricated and characterized. Batch-fabricated components were specifically designed and developed to enable integration within a small form-factor package. The full physics package, implemented with CW VCSEL optical pump, direct end-state hyperfine RF and Zeeman interrogation for magnetic field stabilization, was demonstrated within a 4 cm3 volume, consuming 25 mW of power, and exhibiting an Allan deviation stability. In addition, end-state signal contrast exceeded 40% from millimeter-scale vapor cells with buffer-gas pressures exceeding 2.5 atmospheres, demonstrating the route to submillimeter vapor-cells within high-performance CSACs for high shock/vibration environments.
We describe chip-scale batch-fabricated cesium cells utilizing semiconductor wafer processing, pin transfer of cesium, and silicon/Pyrex anodic bonding for cell sealing. Highspeed, single-mode linearly polarized VCSELs emitting at the 133Cs D1 line were fabricated, optimized for low threshold and high-speed operation with overall small power dissipation. Coherent population trapping (CPT) end-resonance signals with a contrast and linewidth of 5.4% and 7.1 kHz respectively are achieved using 1 mm optical path length cells and VCSEL driven with 1.25 mW RF modulation and 2.76 mW DC power dissipation. We demonstrate short-term stability with an atomic clock built with these components operating on the CPT end-resonance. The magnetic field is stabilized with a novel magnetic field locking scheme tapping the Zeeman resonance.
We have undertaken the development of a chip-scale atomic clock (CSAC) whose design goals include short-term stability, sigma(sub y)(tau=1 hour), of 1x10(exp 11) with a total power consumption of 30 mW and an overall device volume of 1 cu cm. The stringent power requirement dominates the physics package architecture, dictating a small (<5 mm(exp 3) gaseous atomic ensemble interrogated by a low-power semiconductor laser. At PTTI 2002, we reported on initial experimental investigations leading to the decision to employ the coherent population trapping (CPT) interrogation technique. This paper describes our further progress on the CSAC effort, including the development of custom vertical cavity surface emitting laser (VCSEL) sources and techniques for microfabricating miniature cesium vapor cells comprised of anodically bonded silicon and glass. Measurements of the signal contrast and linewidth of both the cesium D1 and D2 resonance transitions are compared, and frequency stability measurements of the CSAC testbed are presented.
The physics package of a chip-scale atomic clock (CSAC) has been successfully realized by integrating vertical cavity surface emitting laser (VCSEL), neutral density (ND) filter, λ/4 wave plate, 87 Rb vapor cell, photodiode (PD), and magnetic coil into a cuboid metal package with a volume of about 2.8 cm 3 . In this physics package, the critical component, 87 Rb vapor cell, is batch-fabricated based on MEMS technology and in-situ chemical reaction method. Pt heater and thermistors are integrated in the physics package. A PTFE pillar is used to support the optical elements in the physics package, in order to reduce the power dissipation. The optical absorption spectrum of 87 Rb D1 line and the microwave frequency correction signal are successfully observed while connecting the package with the servo circuit system. Using the above mentioned packaging solution, a CSAC with short-term frequency stability of about 7 × 10 −10 τ −1/2 has been successfully achieved, which demonstrates that this physics package would become one promising solution for the CSAC.
We present measurements regarding the long-term frequency stability of NIST chip-scale atomic clock (CSAC) physics packages. Changes of the clock frequency are caused mainly through time-dependent light shifts by the frequency-modulated VCSEL and properties of the vapor cell. We suggest advanced CPT interrogation schemes to relax the requirements on the temperature stability of the VCSEL as well as the power of the local oscillator. Finally, we discuss the advantages and limitations of these techniques when implemented into a small package.
We have undertaken a development effort to produce a prototype chip-scale atomic clock (CSAC). The design goals include short-term stability, with a total power consumption of less than 30 mW and overall device volume <1 cubic cm. The stringent power requirement dominates the physics package architecture, necessarily dictating a small volume gaseous atomic ensemble interrogated by a low-power semiconductor laser. At PTTI 2002 and PTTI 2003, we reported on laboratory experiments that underlie the fundamental architecture of our CSAC, based on interrogation of the cesium D1 transition by the technique of coherent population trapping (CPT). In the past year, the development effort has shifted from fundamental research and feasibility investigation to engineering and prototype development. In this paper, we report on the design of a rugged and compact physics package that is expected to exceed the ultimate performance and power requirements of the CSAC.
We describe three independent research directions focussed on the development of next-generation chip-scale atomic clocks, which combine small size, low power consumption and manufacturability with high frequency stability. The use of optical transitions in microfabricated vapor cells improves both short- and long-term frequency stability to near 10−13 at the cost of the added complexity of a chip-scale optical frequency comb. Chip-scale atomic beam microwave clocks have been successfully demonstrated and offer the potential for microsecond-level timing accuracy over one week. And finally, Sr vapor cells have been developed with lifetimes exceeding 250 hours and residual gas pressures below 1 Torr.