Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Metrologia

Towards an uncertainty budget in quantum-efficiency measurements with parametric fluorescence

G. Brida, Stefania Castelletto, Ivo Pietro Degiovanni, Marco Genovese, Carlo Novero, Maria Luisa Rastello

Published Oct 1, 2000• 36 citations
Publisher

Abstract

The aim of this paper is a critical investigation of some correction factors in the quantum-efficiency calibration of photodetectors, in the photon-counting regime, by means of correlated photons generated through a parametric down-conversion process inside a non-linear crystal. An analysis is given of the main correction factors found in a real experimental situation, with different techniques for performing coincidence counts.

DOI
10.1088/0026-1394/37/5/65

Related papers

Quantum efficiency measurement of photodetectors by means of correlated photons

G. Brida, Stefania Castelletto, Carlo Novero +1 more

We report the first results concerning quantum efficiency measurement of photodetectors with the technique of correlated photons generated by parametric down conversion in a nonlinear crystal. Measurements have been performed on photomultipliers in photon counting regime and will be extended to avalanche photodiodes working as single photon detectors.

Conference on Precision Electromagnetic Measurements•Nov 27, 2002•1 citation

Quantum-efficiency measurement of photodetectors by means of correlated photons

G. Brida, Stefania Castelletto, Carlo Novero +1 more

We report the first results obtained at the Istituto Elettrotecnico Nazionale Galileo Ferraris of quantum-efficiency measurements of actively quenched avalanche photodiodes in the photon-counting regime. The measurements were performed with the technique of correlated photons generated by a parametric downconversion process in a nonlinear crystal of lithium iodate, an absolute technique that does not require any standard. We pay special attention to the problem of alignment of the optical bench and to the implementation of a parametric amplifier scheme with a diode-laser source. The technique is described, and results of quantum-efficiency measurements of two photodiodes are presented.

Journal of the Optical Society of America B•Oct 1, 1999•15 citations

Absolute meter of photodetector quantum efficiency based on the parametric down-conversion effect

Vera M. Ginzburg, N. G. Keratishvili, Y. L. Korzhenevich +3 more

The quantum phenomena of parametric down conversion have been used for absolute measurement of the photodetector quantum efficiency of ultra-low-light radiation ranging from 10-12 to 10-15 W, which is equivalent to photon fluxes of 107 to 104 s-1. The process of parametric down conversion gives rise to highly correlated (in time and space) photon flux pairs. We describe the method, experimental investigation, and a new device involving the measurement of the coincidence rate of photodetection of these two correlated beams of light. The coincidence is lowered by a nonunit quantum efficiency of either detection. This fact was used for the definition of the absolute value of both photodetector's quantum efficiencies.

Optical Engineering•Nov 1, 1993•18 citations

Quantum-efficiency measurement of photodetectors based on entangled photons

Wei Zhang

The calibration of radiometric sensors is critical to ensure the accuracy of the remote sensing data and their usability.The current methods of the radiometric calibration are based on the establishment of high-precision primary standard and standard transfer chain,and the transfer chain is the main source of errors.The entangled photons-based theory creates a new technical way to realize the radiometric calibration of standardless transfer.The method of absolute calibration of photodetectors based on a nonclassical effect of the nonlinear optics in the photon-counting regime was discussed.The measurement was realized with the technique of entangled photons at 702 nm generated by a parametric down conversion process in a nonlinear crystal of BBO.The photomultiplier quantum-efficiency at the wavelength was measured during the experiment.It is estimated that the deviation is 0.1%.The technique is independent of any externally calibrated radiometric standards.

Journal of Applied Optics•Jan 1, 2007•0 citations

Measurement of quantum efficiency of avalanche photodetectors based on quantum two-photon field

A. Czitrovszky, Alexander V. Sergienko

A pair of rigorously correlated photons (biphotons) from parametric down conversion makes it possible to use them for measuring the absolute value of the quantum efficiency of the optical detectors, both in photon counting and in analog regimes, that does not use any calibrated standard light sources. Using this method the quantum efficiency of EG&G avalanche photodetectors was determined.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 19, 1998•3 citations

Realization and correction of coincidence counting setup used in correlated photon detection

吕亮 L Liang, 林延东 Lin Yandong

With the aim to realize Quantum Efficiency(QE) measurement of photon detectors based on Spontaneous Parametric Down-conversion(SPDC),two type of coincidence count systems were set up,the correction factors of coincidence count were analyzed and the real experimental methods of correction factors were given.Firstly,the principle of SPDC and the technique using SPDC to calibrate the QE of photo detectors were introduced.Then the design of two type of coincidence count systems,gated dual-photon counter coincidence count system and TAC/MCA coincidence count system,were introduced.Finally,the main correction factors,accidental coincidence,missing coincidence,dead time of counters and detectors were analyzed,and the calculation and test methods were also given.Experimental results show that the deviation between this two type of coincidence setups is less than 0.4% after correction,which indicates that the two setups can satisfy the requirement of QE measurement.

Optics and Precision Engineering•Jan 1, 2011•0 citations
The aim of this paper is a critical investigation of some correction factors in the quantum-efficiency calibration of photodetectors, in the photon-counting regime, by means of correlated photons generated through a parametric down-conversion process inside a non-linear crystal. An analysis is given of the main correction factors found in a real experimental situation, with different techniques for performing coincidence counts.
We report the first results obtained at the Istituto Elettrotecnico Nazionale Galileo Ferraris of quantum-efficiency measurements of actively quenched avalanche photodiodes in the photon-counting regime. The measurements were performed with the technique of correlated photons generated by a parametric downconversion process in a nonlinear crystal of lithium iodate, an absolute technique that does not require any standard. We pay special attention to the problem of alignment of the optical bench and to the implementation of a parametric amplifier scheme with a diode-laser source. The technique is described, and results of quantum-efficiency measurements of two photodiodes are presented.
The quantum phenomena of parametric down conversion have been used for absolute measurement of the photodetector quantum efficiency of ultra-low-light radiation ranging from 10-12 to 10-15 W, which is equivalent to photon fluxes of 107 to 104 s-1. The process of parametric down conversion gives rise to highly correlated (in time and space) photon flux pairs. We describe the method, experimental investigation, and a new device involving the measurement of the coincidence rate of photodetection of these two correlated beams of light. The coincidence is lowered by a nonunit quantum efficiency of either detection. This fact was used for the definition of the absolute value of both photodetector's quantum efficiencies.
The calibration of radiometric sensors is critical to ensure the accuracy of the remote sensing data and their usability.The current methods of the radiometric calibration are based on the establishment of high-precision primary standard and standard transfer chain,and the transfer chain is the main source of errors.The entangled photons-based theory creates a new technical way to realize the radiometric calibration of standardless transfer.The method of absolute calibration of photodetectors based on a nonclassical effect of the nonlinear optics in the photon-counting regime was discussed.The measurement was realized with the technique of entangled photons at 702 nm generated by a parametric down conversion process in a nonlinear crystal of BBO.The photomultiplier quantum-efficiency at the wavelength was measured during the experiment.It is estimated that the deviation is 0.1%.The technique is independent of any externally calibrated radiometric standards.
With the aim to realize Quantum Efficiency(QE) measurement of photon detectors based on Spontaneous Parametric Down-conversion(SPDC),two type of coincidence count systems were set up,the correction factors of coincidence count were analyzed and the real experimental methods of correction factors were given.Firstly,the principle of SPDC and the technique using SPDC to calibrate the QE of photo detectors were introduced.Then the design of two type of coincidence count systems,gated dual-photon counter coincidence count system and TAC/MCA coincidence count system,were introduced.Finally,the main correction factors,accidental coincidence,missing coincidence,dead time of counters and detectors were analyzed,and the calculation and test methods were also given.Experimental results show that the deviation between this two type of coincidence setups is less than 0.4% after correction,which indicates that the two setups can satisfy the requirement of QE measurement.