Journal of the Optical Society of America B

Quantum-efficiency measurement of photodetectors by means of correlated photons

G. Brida, Stefania Castelletto, Carlo Novero, Maria Luisa Rastello

Published Oct 1, 1999• 15 citations
Publisher

Abstract

We report the first results obtained at the Istituto Elettrotecnico Nazionale Galileo Ferraris of quantum-efficiency measurements of actively quenched avalanche photodiodes in the photon-counting regime. The measurements were performed with the technique of correlated photons generated by a parametric downconversion process in a nonlinear crystal of lithium iodate, an absolute technique that does not require any standard. We pay special attention to the problem of alignment of the optical bench and to the implementation of a parametric amplifier scheme with a diode-laser source. The technique is described, and results of quantum-efficiency measurements of two photodiodes are presented.

DOI
10.1364/josab.16.001623

Related papers

Quantum efficiency measurement of photodetectors by means of correlated photons

G. Brida, Stefania Castelletto, Carlo Novero +1 more

We report the first results concerning quantum efficiency measurement of photodetectors with the technique of correlated photons generated by parametric down conversion in a nonlinear crystal. Measurements have been performed on photomultipliers in photon counting regime and will be extended to avalanche photodiodes working as single photon detectors.

Conference on Precision Electromagnetic Measurements•Nov 27, 2002•1 citation

Intercomparison of a correlated-photon-based method to measure detector quantum efficiency

Alan L. Migdall, Stefania Castelletto, Ivo Pietro Degiovanni +1 more

We report on the absolute calibration of photodetector quantum efficiency by using correlated photon sources, performed independently at two laboratories, the National Institute of Standards and Technology and the Istituto Elettrotecnico Nazionale (IEN). The goal is to use an interlaboratory comparison to demonstrate the inherent absoluteness of the photon correlation technique by showing its independence from the particular experimental setup. We find that detector nonuniformity limited this comparison rather than uncertainty inherent in the method itself. The ultimate goal of these investigations is development of a robust measurement protocol that allows the uncertainties of individual measurements to be determined experimentally and verified operationally. Furthermore, to demonstrate the generality of the procedure, the IEN measurement setup was also used to calibrate a fiber-coupled avalanche photodiode module. Uncertainties are evaluated for the detector both with and without fiber coupling and differences are discussed. The current IEN setup using a thinner and higher transmittance nonlinear crystal for the generation of correlated photons shows a significant improvement in overall accuracy with respect to previously reported results from IEN [Metrologia 32, 501-503 (1996)].

Applied Optics•May 20, 2002•33 citations

Measurement of quantum efficiency of avalanche photodetectors based on quantum two-photon field

A. Czitrovszky, Alexander V. Sergienko

A pair of rigorously correlated photons (biphotons) from parametric down conversion makes it possible to use them for measuring the absolute value of the quantum efficiency of the optical detectors, both in photon counting and in analog regimes, that does not use any calibrated standard light sources. Using this method the quantum efficiency of EG&G avalanche photodetectors was determined.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 19, 1998•3 citations

Quantum-efficiency measurement of photodetectors based on entangled photons

Wei Zhang

The calibration of radiometric sensors is critical to ensure the accuracy of the remote sensing data and their usability.The current methods of the radiometric calibration are based on the establishment of high-precision primary standard and standard transfer chain,and the transfer chain is the main source of errors.The entangled photons-based theory creates a new technical way to realize the radiometric calibration of standardless transfer.The method of absolute calibration of photodetectors based on a nonclassical effect of the nonlinear optics in the photon-counting regime was discussed.The measurement was realized with the technique of entangled photons at 702 nm generated by a parametric down conversion process in a nonlinear crystal of BBO.The photomultiplier quantum-efficiency at the wavelength was measured during the experiment.It is estimated that the deviation is 0.1%.The technique is independent of any externally calibrated radiometric standards.

Journal of Applied Optics•Jan 1, 2007•0 citations

Towards an uncertainty budget in quantum-efficiency measurements with parametric fluorescence

G. Brida, Stefania Castelletto, Ivo Pietro Degiovanni +3 more

The aim of this paper is a critical investigation of some correction factors in the quantum-efficiency calibration of photodetectors, in the photon-counting regime, by means of correlated photons generated through a parametric down-conversion process inside a non-linear crystal. An analysis is given of the main correction factors found in a real experimental situation, with different techniques for performing coincidence counts.

Metrologia•Oct 1, 2000•36 citations

Correlated photon metrology of detectors and sources.

Jessica Y. Cheung, M. P. Vaughan, John R. Mountford +1 more

Many of the schemes under study for Quantum Information Processing technology based on photon states involve active and passive optical components as well as detectors. In order to able to establish fidelity levels for these schemes, the performance of the optical components and the quantum efficiency (q.e.) of the detectors require careful and accurate characterization. Correlated photons produced from spontaneous parametric downconversion, which are also the basis of entangled photon states, conveniently offer a direct means of measuring detector q.e. in the photon counting regime, while stimulated parametric downconversion can be used to measure source radiance. Detector and source calibration using correlated photon techniques therefore addresses some of the key issues critical to the development of QIP technology and the development of correlated/entangled photon metrology. This paper reports work being undertaken at NPL to establish the accuracy limitations of these correlated photon techniques. Significant sources of uncertainty are the need to measure losses due to any optical components used and the requirement to obtain and maintain good geometrical and spectral alignment.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jan 1, 2004•3 citations
We report the first results obtained at the Istituto Elettrotecnico Nazionale Galileo Ferraris of quantum-efficiency measurements of actively quenched avalanche photodiodes in the photon-counting regime. The measurements were performed with the technique of correlated photons generated by a parametric downconversion process in a nonlinear crystal of lithium iodate, an absolute technique that does not require any standard. We pay special attention to the problem of alignment of the optical bench and to the implementation of a parametric amplifier scheme with a diode-laser source. The technique is described, and results of quantum-efficiency measurements of two photodiodes are presented.
We report on the absolute calibration of photodetector quantum efficiency by using correlated photon sources, performed independently at two laboratories, the National Institute of Standards and Technology and the Istituto Elettrotecnico Nazionale (IEN). The goal is to use an interlaboratory comparison to demonstrate the inherent absoluteness of the photon correlation technique by showing its independence from the particular experimental setup. We find that detector nonuniformity limited this comparison rather than uncertainty inherent in the method itself. The ultimate goal of these investigations is development of a robust measurement protocol that allows the uncertainties of individual measurements to be determined experimentally and verified operationally. Furthermore, to demonstrate the generality of the procedure, the IEN measurement setup was also used to calibrate a fiber-coupled avalanche photodiode module. Uncertainties are evaluated for the detector both with and without fiber coupling and differences are discussed. The current IEN setup using a thinner and higher transmittance nonlinear crystal for the generation of correlated photons shows a significant improvement in overall accuracy with respect to previously reported results from IEN [Metrologia 32, 501-503 (1996)].
The calibration of radiometric sensors is critical to ensure the accuracy of the remote sensing data and their usability.The current methods of the radiometric calibration are based on the establishment of high-precision primary standard and standard transfer chain,and the transfer chain is the main source of errors.The entangled photons-based theory creates a new technical way to realize the radiometric calibration of standardless transfer.The method of absolute calibration of photodetectors based on a nonclassical effect of the nonlinear optics in the photon-counting regime was discussed.The measurement was realized with the technique of entangled photons at 702 nm generated by a parametric down conversion process in a nonlinear crystal of BBO.The photomultiplier quantum-efficiency at the wavelength was measured during the experiment.It is estimated that the deviation is 0.1%.The technique is independent of any externally calibrated radiometric standards.
Many of the schemes under study for Quantum Information Processing technology based on photon states involve active and passive optical components as well as detectors. In order to able to establish fidelity levels for these schemes, the performance of the optical components and the quantum efficiency (q.e.) of the detectors require careful and accurate characterization. Correlated photons produced from spontaneous parametric downconversion, which are also the basis of entangled photon states, conveniently offer a direct means of measuring detector q.e. in the photon counting regime, while stimulated parametric downconversion can be used to measure source radiance. Detector and source calibration using correlated photon techniques therefore addresses some of the key issues critical to the development of QIP technology and the development of correlated/entangled photon metrology. This paper reports work being undertaken at NPL to establish the accuracy limitations of these correlated photon techniques. Significant sources of uncertainty are the need to measure losses due to any optical components used and the requirement to obtain and maintain good geometrical and spectral alignment.