Conference on Precision Electromagnetic Measurements

Quantum efficiency measurement of photodetectors by means of correlated photons

G. Brida, Stefania Castelletto, Carlo Novero, Maria Luisa Rastello

Published Nov 27, 2002• 1 citation
Publisher

Abstract

We report the first results concerning quantum efficiency measurement of photodetectors with the technique of correlated photons generated by parametric down conversion in a nonlinear crystal. Measurements have been performed on photomultipliers in photon counting regime and will be extended to avalanche photodiodes working as single photon detectors.

DOI
10.1109/cpem.1998.699934

Related papers

Quantum-efficiency measurement of photodetectors by means of correlated photons

G. Brida, Stefania Castelletto, Carlo Novero +1 more

We report the first results obtained at the Istituto Elettrotecnico Nazionale Galileo Ferraris of quantum-efficiency measurements of actively quenched avalanche photodiodes in the photon-counting regime. The measurements were performed with the technique of correlated photons generated by a parametric downconversion process in a nonlinear crystal of lithium iodate, an absolute technique that does not require any standard. We pay special attention to the problem of alignment of the optical bench and to the implementation of a parametric amplifier scheme with a diode-laser source. The technique is described, and results of quantum-efficiency measurements of two photodiodes are presented.

Journal of the Optical Society of America B•Oct 1, 1999•15 citations

Measurement of quantum efficiency of avalanche photodetectors based on quantum two-photon field

A. Czitrovszky, Alexander V. Sergienko

A pair of rigorously correlated photons (biphotons) from parametric down conversion makes it possible to use them for measuring the absolute value of the quantum efficiency of the optical detectors, both in photon counting and in analog regimes, that does not use any calibrated standard light sources. Using this method the quantum efficiency of EG&G avalanche photodetectors was determined.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 19, 1998•3 citations

Measurement of quantum efficiency using correlated photon pairs and a single-detector technique

A. Czitrovszky, Alexander V. Sergienko, Peter J. Jani +1 more

A new approach is proposed to the calibration of photodetectors and the determination of the absolute value of the quantum efficiency of photon-counting photomultipliers using entangled-photon pairs. It is based on a new single-photodetector technique and a special modulation of the entangled-photon flux. The absolute values of the quantum efficiency have been determined for several photon-counting photomultipliers.

Metrologia•Oct 1, 2000•14 citations

Towards an uncertainty budget in quantum-efficiency measurements with parametric fluorescence

G. Brida, Stefania Castelletto, Ivo Pietro Degiovanni +3 more

The aim of this paper is a critical investigation of some correction factors in the quantum-efficiency calibration of photodetectors, in the photon-counting regime, by means of correlated photons generated through a parametric down-conversion process inside a non-linear crystal. An analysis is given of the main correction factors found in a real experimental situation, with different techniques for performing coincidence counts.

Metrologia•Oct 1, 2000•36 citations

Quantum-efficiency measurement of photodetectors based on entangled photons

Wei Zhang

The calibration of radiometric sensors is critical to ensure the accuracy of the remote sensing data and their usability.The current methods of the radiometric calibration are based on the establishment of high-precision primary standard and standard transfer chain,and the transfer chain is the main source of errors.The entangled photons-based theory creates a new technical way to realize the radiometric calibration of standardless transfer.The method of absolute calibration of photodetectors based on a nonclassical effect of the nonlinear optics in the photon-counting regime was discussed.The measurement was realized with the technique of entangled photons at 702 nm generated by a parametric down conversion process in a nonlinear crystal of BBO.The photomultiplier quantum-efficiency at the wavelength was measured during the experiment.It is estimated that the deviation is 0.1%.The technique is independent of any externally calibrated radiometric standards.

Journal of Applied Optics•Jan 1, 2007•0 citations

Absolute self-calibration of the quantum efficiency of single-photon detectors

Xihao Chen, Yanhua Zhai, Da Zhang +1 more

Single-photon detectors are finding increasingly wide application in all branches of science and technology thus a precise knowledge of their quantum efficiency is an essential prerequisite. We have performed the first proof-of-principle demonstration of a means to determine the quantum efficiency by which no second detector or reference standard is required. This absolute self-calibration method is based on the time correlation of entangled photons pairs emitted in spontaneous parametric down conversion. The measured quantum efficiency of a Si avalanche photodiode single-photon detector agrees well with the product specifications.

Optics Letters•Jul 25, 2006•21 citations
We report the first results concerning quantum efficiency measurement of photodetectors with the technique of correlated photons generated by parametric down conversion in a nonlinear crystal. Measurements have been performed on photomultipliers in photon counting regime and will be extended to avalanche photodiodes working as single photon detectors.
We report the first results obtained at the Istituto Elettrotecnico Nazionale Galileo Ferraris of quantum-efficiency measurements of actively quenched avalanche photodiodes in the photon-counting regime. The measurements were performed with the technique of correlated photons generated by a parametric downconversion process in a nonlinear crystal of lithium iodate, an absolute technique that does not require any standard. We pay special attention to the problem of alignment of the optical bench and to the implementation of a parametric amplifier scheme with a diode-laser source. The technique is described, and results of quantum-efficiency measurements of two photodiodes are presented.
The calibration of radiometric sensors is critical to ensure the accuracy of the remote sensing data and their usability.The current methods of the radiometric calibration are based on the establishment of high-precision primary standard and standard transfer chain,and the transfer chain is the main source of errors.The entangled photons-based theory creates a new technical way to realize the radiometric calibration of standardless transfer.The method of absolute calibration of photodetectors based on a nonclassical effect of the nonlinear optics in the photon-counting regime was discussed.The measurement was realized with the technique of entangled photons at 702 nm generated by a parametric down conversion process in a nonlinear crystal of BBO.The photomultiplier quantum-efficiency at the wavelength was measured during the experiment.It is estimated that the deviation is 0.1%.The technique is independent of any externally calibrated radiometric standards.
Single-photon detectors are finding increasingly wide application in all branches of science and technology thus a precise knowledge of their quantum efficiency is an essential prerequisite. We have performed the first proof-of-principle demonstration of a means to determine the quantum efficiency by which no second detector or reference standard is required. This absolute self-calibration method is based on the time correlation of entangled photons pairs emitted in spontaneous parametric down conversion. The measured quantum efficiency of a Si avalanche photodiode single-photon detector agrees well with the product specifications.