Optical Engineering

Absolute meter of photodetector quantum efficiency based on the parametric down-conversion effect

Vera M. Ginzburg, N. G. Keratishvili, Y. L. Korzhenevich, G. V. Lunev, Alexander N. Penin, Victor I. Sapritsky

Published Nov 1, 1993• 18 citations
Publisher

Abstract

The quantum phenomena of parametric down conversion have been used for absolute measurement of the photodetector quantum efficiency of ultra-low-light radiation ranging from 10-12 to 10-15 W, which is equivalent to photon fluxes of 107 to 104 s-1. The process of parametric down conversion gives rise to highly correlated (in time and space) photon flux pairs. We describe the method, experimental investigation, and a new device involving the measurement of the coincidence rate of photodetection of these two correlated beams of light. The coincidence is lowered by a nonunit quantum efficiency of either detection. This fact was used for the definition of the absolute value of both photodetector's quantum efficiencies.

DOI
10.1117/12.147702

Related papers

Absolute measurement of photodetector quantum efficiency based on spontaneous parametric down-conversion biphoton field

Liqun Sun, Yanpeng Zhang, Tiantong Tang +2 more

A new method of absolute measurement of photodetector quantum efficiency based on spontaneous parametric down- conversion (SPDC) biphoton field is discussed. The process of SPDC is studied theoretically. The single photon detection probability and two-photon coincidence probability are derived and the measurement principle of photodetectors is explained. An experimental system has been set up. The quantum efficiency of a photon-counting photomultiplier tube was measured, and the results were compared with that obtained using conventional method.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Nov 4, 1999•0 citations

Measurement of quantum efficiency of avalanche photodetectors based on quantum two-photon field

A. Czitrovszky, Alexander V. Sergienko

A pair of rigorously correlated photons (biphotons) from parametric down conversion makes it possible to use them for measuring the absolute value of the quantum efficiency of the optical detectors, both in photon counting and in analog regimes, that does not use any calibrated standard light sources. Using this method the quantum efficiency of EG&G avalanche photodetectors was determined.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 19, 1998•3 citations

Absolute Measurement of Quantum Efficiency Based on Parametric Down-conversion Effect

V. M. Ginzburg, N. G. Keratishvili, Y. L. Korzhenevich +2 more

A new radiometric method which employs quantum properties of radiation and does not require the use of standard radiation sources and receivers has been suggested. This method uses the process of three-photon down conversion in non-central-symmetrical media to measure the quantum efficiency of photodetectors.

Metrologia•Jan 1, 1993•10 citations

Absolute standardless calibration of photodetectors based on quantum two-photon fields

Alexander N. Penin, Alexander V. Sergienko

A new method of absolute calibration of photodetectors based on a nonclassical effect in nonlinear optics is discussed. The combined influence of a monochromatic flux of pump photons and quantum vacuum noise on a nonlinear crystal with no center of symmetry results in the appearance of rigorously correlated pairs of photons with continuous spectral distribution in the spontaneous parametric scattering of light (spontaneous parametric downconversion) process. The presence of an optical field in a broad spectral range created by the two-photon states (biphotons) makes it possible to develop a new method of measuring the spectral distribution of the absolute value of the quantum efficiency of photodetectors, both in photon counting and in analog regimes, that does not use any calibrated standard light sources (étalons). The feasibility of the method is demonstrated on different types of photomultiplier tube.

Applied Optics•Sep 1, 1991•65 citations

Measuring the absolute photodetection efficiency using photon number correlations

Michael Lindenthal, Johannes Kofler

We present two methods for determining the absolute detection efficiency of photon-counting detectors directly from their singles rates under illumination from a nonclassical light source. One method is based on a continuous variable analog to coincidence counting in discrete photon experiments, but it does not actually rely on high detector time resolutions. The second method is based on difference detection, which is a typical detection scheme in continuous variable quantum optics experiments. Since no coincidence detection is required with either method, they are useful for detection efficiency measurements of photodetectors with detector time resolutions far too low to resolve coincidence events.

arXiv:quant-ph/0606041•Applied Optics•Aug 20, 2006•10 citations

Absolute self-calibration of single-photon detectors with cw and pulsed spontaneous parametric down-conversion

Ling-An Wu, Xi-Hao Chen, Yanhua Zhai +2 more

Single-photon detectors are of great importance in spectroscopy, laser ranging, astronomy and wherever weak light detection is required, so a precise knowledge of their quantum efficiency is essential, but their calibration is by no means trivial. Traditional methods need a black body radiation source or a highly attenuated laser beam as a reference standard, or an already calibrated reference detector. It is well known that absolute measurement of the quantum efficiency, absolute in the sense that the calibration is independent of any radiometric standard or the properties of another detector, can be performed using entangled twin photons generated in optical spontaneous parametric down-conversion together with a reference detector. We have performed the first proof-of-principle experiment to determine the quantum efficiency by which no second detector or reference standard is required. This absolute self-calibration method is also based on the time correlation of photons emitted in parametric down-conversion, but with the introduction of a suitable time delay between the arrival times of the twin photons. Furthermore, we describe a scheme for absolute self-calibration of the quantum efficiency at different wavelengths by means of a pulsed source of nondegenerate down-converted photons. This method should have even greater potential for applications.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 31, 2006•0 citations
The quantum phenomena of parametric down conversion have been used for absolute measurement of the photodetector quantum efficiency of ultra-low-light radiation ranging from 10-12 to 10-15 W, which is equivalent to photon fluxes of 107 to 104 s-1. The process of parametric down conversion gives rise to highly correlated (in time and space) photon flux pairs. We describe the method, experimental investigation, and a new device involving the measurement of the coincidence rate of photodetection of these two correlated beams of light. The coincidence is lowered by a nonunit quantum efficiency of either detection. This fact was used for the definition of the absolute value of both photodetector's quantum efficiencies.
A new method of absolute measurement of photodetector quantum efficiency based on spontaneous parametric down- conversion (SPDC) biphoton field is discussed. The process of SPDC is studied theoretically. The single photon detection probability and two-photon coincidence probability are derived and the measurement principle of photodetectors is explained. An experimental system has been set up. The quantum efficiency of a photon-counting photomultiplier tube was measured, and the results were compared with that obtained using conventional method.
A new method of absolute calibration of photodetectors based on a nonclassical effect in nonlinear optics is discussed. The combined influence of a monochromatic flux of pump photons and quantum vacuum noise on a nonlinear crystal with no center of symmetry results in the appearance of rigorously correlated pairs of photons with continuous spectral distribution in the spontaneous parametric scattering of light (spontaneous parametric downconversion) process. The presence of an optical field in a broad spectral range created by the two-photon states (biphotons) makes it possible to develop a new method of measuring the spectral distribution of the absolute value of the quantum efficiency of photodetectors, both in photon counting and in analog regimes, that does not use any calibrated standard light sources (étalons). The feasibility of the method is demonstrated on different types of photomultiplier tube.
We present two methods for determining the absolute detection efficiency of photon-counting detectors directly from their singles rates under illumination from a nonclassical light source. One method is based on a continuous variable analog to coincidence counting in discrete photon experiments, but it does not actually rely on high detector time resolutions. The second method is based on difference detection, which is a typical detection scheme in continuous variable quantum optics experiments. Since no coincidence detection is required with either method, they are useful for detection efficiency measurements of photodetectors with detector time resolutions far too low to resolve coincidence events.
Single-photon detectors are of great importance in spectroscopy, laser ranging, astronomy and wherever weak light detection is required, so a precise knowledge of their quantum efficiency is essential, but their calibration is by no means trivial. Traditional methods need a black body radiation source or a highly attenuated laser beam as a reference standard, or an already calibrated reference detector. It is well known that absolute measurement of the quantum efficiency, absolute in the sense that the calibration is independent of any radiometric standard or the properties of another detector, can be performed using entangled twin photons generated in optical spontaneous parametric down-conversion together with a reference detector. We have performed the first proof-of-principle experiment to determine the quantum efficiency by which no second detector or reference standard is required. This absolute self-calibration method is also based on the time correlation of photons emitted in parametric down-conversion, but with the introduction of a suitable time delay between the arrival times of the twin photons. Furthermore, we describe a scheme for absolute self-calibration of the quantum efficiency at different wavelengths by means of a pulsed source of nondegenerate down-converted photons. This method should have even greater potential for applications.