Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment

Normal metal–insulator–superconductor junction technology for bolometers

Daniel R. Schmidt, William Duncan, K. D. Irwin, Konrad W. Lehnert, N.A. Miller, Joel N. Ullom

Published Jan 5, 2006• 5 citations
Publisher
DOI
10.1016/j.nima.2005.12.043

Related papers

A superconductor–insulator–normal metal bolometer with microwave readout suitable for large-format arrays

Daniel R. Schmidt, Konrad W. Lehnert, A. M. Clark +4 more

Applied Physics Letters•Jan 27, 2005•44 citations

Thermo-electric charge-to-voltage converter with superconductor–insulator–normal tunnel junction for bolometer applications

L. S. Kuzmin

Physica C Superconductivity•Aug 7, 2010•1 citation

A Superconducting Cold-Electron Bolometer with SIS’ and Josephson Tunnel Junctions

L. S. Kuzmin

Journal of Low Temperature Physics•Jan 18, 2008•12 citations

Capacitively coupled hot-electron nanobolometer as far-infrared photon counter

Dragoş-Victor Anghel, L. S. Kuzmin

We show theoretically that hot-electron nanobolometers consisting of a small piece of normal metal, capacitively coupled to a superconducting antenna through a pair of normal metal–insulator–superconductor (NIS) tunnel junctions may be used as far-infrared photon counters. To make the device most effective at high counting rates, we suggest the use of the bolometer in the simplest configuration, when the NIS tunnel junctions are used as both an electron cooler and thermometer. The absorbtion of the photon in the normal metal produces a pulse in the electron temperature, which is measured by the NIS junctions. The counter may resolve photons up to 0.3–0.4 mm wavelength and has a typical re-equilibration time constant of about 20 ns.

arXiv:cond-mat/0212288•Applied Physics Letters•Jan 9, 2003•19 citations

Terahertz spectroscopy with a Josephson oscillator and a SINIS bolometer

Michael A. Tarasov, L. S. Kuzmin, Е. А. Степанцов +5 more

The voltage response of a thin-film normal-metal hot-electron bolometer based on a SINIS (superconductor-insulator-normal metal-insulator-superconductor) structure to the radiation of a high-temperature Josephson junction in the terahertz frequency region was measured. Bolometers were integrated with planar log-periodic and double-dipole antennas, and Josephson junctions were integrated with log-periodic antennas. Measurements showed that the Josephson junction at a temperature of 260 mK was overheated by the transport current, so that its electron temperature exceeded 3 K at a bias voltage of 1 mV. The maximum response of a bolometer with a double-dipole antenna was observed at a frequency of 300 GHz, which agreed well with the calculated value. The Josephson radiation was observed at frequencies up to 1.7 THz. The voltage response of a bolometer reached 4×10 8 V/W, and the total noise-equivalent power reached 1.5×10 −17 W/Hz 1/2 .

Journal of Experimental and Theoretical Physics Letters•Mar 1, 2004•10 citations

High speed hot-electron superconducting bolometer

G. N. Gol'tsman

International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz)•Aug 30, 1993•0 citations
We show theoretically that hot-electron nanobolometers consisting of a small piece of normal metal, capacitively coupled to a superconducting antenna through a pair of normal metal–insulator–superconductor (NIS) tunnel junctions may be used as far-infrared photon counters. To make the device most effective at high counting rates, we suggest the use of the bolometer in the simplest configuration, when the NIS tunnel junctions are used as both an electron cooler and thermometer. The absorbtion of the photon in the normal metal produces a pulse in the electron temperature, which is measured by the NIS junctions. The counter may resolve photons up to 0.3–0.4 mm wavelength and has a typical re-equilibration time constant of about 20 ns.
The voltage response of a thin-film normal-metal hot-electron bolometer based on a SINIS (superconductor-insulator-normal metal-insulator-superconductor) structure to the radiation of a high-temperature Josephson junction in the terahertz frequency region was measured. Bolometers were integrated with planar log-periodic and double-dipole antennas, and Josephson junctions were integrated with log-periodic antennas. Measurements showed that the Josephson junction at a temperature of 260 mK was overheated by the transport current, so that its electron temperature exceeded 3 K at a bias voltage of 1 mV. The maximum response of a bolometer with a double-dipole antenna was observed at a frequency of 300 GHz, which agreed well with the calculated value. The Josephson radiation was observed at frequencies up to 1.7 THz. The voltage response of a bolometer reached 4×10 8 V/W, and the total noise-equivalent power reached 1.5×10 −17 W/Hz 1/2 .