Journal of Low Temperature Physics

A Superconducting Cold-Electron Bolometer with SIS’ and Josephson Tunnel Junctions

L. S. Kuzmin

Published Jan 18, 2008• 12 citations
Publisher
DOI
10.1007/s10909-007-9654-9

Related papers

On the concept of an optimal hot-electron bolometer with NIS tunnel junctions

L. S. Kuzmin, Dmitry S. Golubev

Physica C Superconductivity•Aug 1, 2002•35 citations

Superconducting cold-electron bolometer with proximity traps

L. S. Kuzmin

Microelectronic Engineering•Jul 16, 2003•11 citations

A parallel/series array of superconducting cold-electron bolometers with SIS' tunnel junctions

L. S. Kuzmin

A novel concept of the parallel/series array of Cold-Electron Bolometers (CEB) with Superconductor-Insulator-Normal (SIN) Tunnel Junctions has been proposed for matching with JFET readout. The current-biased CEBs are connected in series for DC and in parallel for HF signal. A signal is concentrated to the absorber through the capacitance of tunnel junctions and additional capacitance for coupling of superconducting islands. Due to dividing power between CEBs in the array and increasing responsivity, the noise matching could be effectively optimized and the photon Noise Equivalent Power could be easily achieved at 300 mK with a room temperature JFET readout.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jul 17, 2008•3 citations

High speed hot-electron superconducting bolometer

G. N. Gol'tsman

International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz)•Aug 30, 1993•0 citations

Concept of a mixer based on a cold-electron bolometer

Michael A. Tarasov, L. S. Kuzmin

A phase-sensitive terahertz heterodyne mixer of a new type based on a cold-electron bolometer is proposed. In this mixer, a normal-metal thin-film absorber is connected to a planar antenna via superconductor-insulator-normal metal (SIN) tunnel junctions, thus forming a SINIS structure. The SINIS mixer combines the advantages of a hot-electron bolometer (HEB), such as a high signal frequency at a small local oscillator power, with the advantages of an SIS mixer, including low noise level, a high intermediate frequency, and wide working temperature range (up to a critical temperature of the superconductor). In contrast to the HEB and SIS mixers, the proposed device is less sensitive to external magnetic noise and exhibits no additional noise related to the superconducting transition and the Josephson effect.

Journal of Experimental and Theoretical Physics Letters•May 1, 2005•7 citations

The design and instrumentation of a superconducting bolometer

Jerald Ray Hyde

•Jan 1, 2015•0 citations
A novel concept of the parallel/series array of Cold-Electron Bolometers (CEB) with Superconductor-Insulator-Normal (SIN) Tunnel Junctions has been proposed for matching with JFET readout. The current-biased CEBs are connected in series for DC and in parallel for HF signal. A signal is concentrated to the absorber through the capacitance of tunnel junctions and additional capacitance for coupling of superconducting islands. Due to dividing power between CEBs in the array and increasing responsivity, the noise matching could be effectively optimized and the photon Noise Equivalent Power could be easily achieved at 300 mK with a room temperature JFET readout.
A phase-sensitive terahertz heterodyne mixer of a new type based on a cold-electron bolometer is proposed. In this mixer, a normal-metal thin-film absorber is connected to a planar antenna via superconductor-insulator-normal metal (SIN) tunnel junctions, thus forming a SINIS structure. The SINIS mixer combines the advantages of a hot-electron bolometer (HEB), such as a high signal frequency at a small local oscillator power, with the advantages of an SIS mixer, including low noise level, a high intermediate frequency, and wide working temperature range (up to a critical temperature of the superconductor). In contrast to the HEB and SIS mixers, the proposed device is less sensitive to external magnetic noise and exhibits no additional noise related to the superconducting transition and the Josephson effect.