Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Experimental and Theoretical Physics Letters

Concept of a mixer based on a cold-electron bolometer

Michael A. Tarasov, L. S. Kuzmin

Published May 1, 2005• 7 citations
Publisher

Abstract

A phase-sensitive terahertz heterodyne mixer of a new type based on a cold-electron bolometer is proposed. In this mixer, a normal-metal thin-film absorber is connected to a planar antenna via superconductor-insulator-normal metal (SIN) tunnel junctions, thus forming a SINIS structure. The SINIS mixer combines the advantages of a hot-electron bolometer (HEB), such as a high signal frequency at a small local oscillator power, with the advantages of an SIS mixer, including low noise level, a high intermediate frequency, and wide working temperature range (up to a critical temperature of the superconductor). In contrast to the HEB and SIS mixers, the proposed device is less sensitive to external magnetic noise and exhibits no additional noise related to the superconducting transition and the Josephson effect.

DOI
10.1134/1.1996765

Related papers

Low-Noise Superconducting Mixers for the Terahertz Frequency Range

Victor Y. Belitsky, Serguei Cherednichenko, Dag Winkler

This chapter discusses the high sensitivity superconducting mixers, i.e. detectors used in heterodyne receivers. Today, there are essentially two very successful concepts of superconducting mixers, or frequency down-converters, the superconductor-insulator-superconductor tunnel junction SIS mixer and the superconducting hot-electron bolometer mixer. Moving up to higher frequencies in the microwave and millimeter wave electromagnetic spectra makes it more and more difficult to retrieve a good signal-to-noise ratio with ordinary solid-state amplifiers. The driving force for using superconducting mixers is their excellent down-conversion efficiency and capability to down-convert RF signals from microwave frequencies up to the terahertz region. The main purpose of a receiver is to pick up and amplify a weak signal, which can then be accurately determined in amplitude and phase. The mixer noise temperature and conversion gain are the most important parameters for the mixing device. The Josephson junction mixer was one of the first suggested devices based on superconducting point contacts and later tunnel junctions.

CRC Press eBooks•May 17, 2022•1 citation

Hot-electron bolometer mixers for terahertz radiation

K. Ilin, Alexei D. Semenov, Heinz‐Wilhelm Hübers +1 more

Hot-electron bolometer (HEB) mixers are used in many low noise heterodyne radio astronomical receivers. Their noise temperature is at the level of 10–15 times the quantum limit, and their gain bandwidth is from 2 GHz to slightly more than 5 GHz depending on the type of substrate material used for a device fabrication. The HEB mixers presented in this Letter are a complex multilayer thin-film structure containing an ultra-thin superconducting film of NbN as a detecting element, and a thick normal metal layer as an antenna structure. The overall performance of the device has been improved by optimisation of the HEB mixer fabrication steps starting with ultra-thin NbN films, followed by NbN/Au bi-layers for antenna structures. Patterning was achieved using electron-beam lithography and lift-off processes. The noise temperature of the HEB mixer fabricated with the improved technology is about 800 K, as measured in a cryogenic-free system with a quantum cascade laser as a local oscillator.

Electronics Letters•Dec 23, 2010•1 citation

Fabrication of high-T/sub c/ hot-electron bolometric mixers for terahertz applications

Michael J. Burns, Alan W. Kleinsasser, K. A. Delin +4 more

Superconducting hot-electron bolometers (HEB) represent a promising candidate for heterodyne mixing at frequencies exceeding 1 THz. Nb HEB mixers offer performance competitive with tunnel junctions without the frequency limit imposed by the superconducting energy gap. Although the performance of YBa/sub 2/Cu/sub 3/O/sub 7-/spl delta// HEB mixers is not projected to be superior to that of Nb devices, which operate at low temperatures, they introduce the possibility of sensitive, low power heterodyne detectors operating at temperatures approaching 90 K for applications requiring portability and closed-cycle refrigeration. We report on the fabrication and characterization, both DC and RF, of high-T/sub c/ mixers based on ultra-thin (/spl les/20 nm) YBa/sub 2/Cu/sub 3/O/sub 7-/spl delta// films patterned to micrometer dimensions and incorporated into 2.5 THz planar mixer circuits.

IEEE Transactions on Applied Superconductivity•Jun 1, 1997•11 citations

Terahertz spectroscopy with a Josephson oscillator and a SINIS bolometer

Michael A. Tarasov, L. S. Kuzmin, Е. А. Степанцов +5 more

The voltage response of a thin-film normal-metal hot-electron bolometer based on a SINIS (superconductor-insulator-normal metal-insulator-superconductor) structure to the radiation of a high-temperature Josephson junction in the terahertz frequency region was measured. Bolometers were integrated with planar log-periodic and double-dipole antennas, and Josephson junctions were integrated with log-periodic antennas. Measurements showed that the Josephson junction at a temperature of 260 mK was overheated by the transport current, so that its electron temperature exceeded 3 K at a bias voltage of 1 mV. The maximum response of a bolometer with a double-dipole antenna was observed at a frequency of 300 GHz, which agreed well with the calculated value. The Josephson radiation was observed at frequencies up to 1.7 THz. The voltage response of a bolometer reached 4×10 8 V/W, and the total noise-equivalent power reached 1.5×10 −17 W/Hz 1/2 .

Journal of Experimental and Theoretical Physics Letters•Mar 1, 2004•10 citations

Superconducting hot-electron bolometer mixers and their applications

Wen Zhang, Wei Miao, Yuan Ren +2 more

Superconducting hot electron bolometer (HEB) mixers are the most sensitive heterodyne detectors at frequencies beyond 1 THz, and are used for many astronomical observations. HEB, consisting of a narrow and short superconducting thin film patch connected to an antenna via contact pads, is brought into a highly sensitive operating regime by applying a DC current and a certain amount of local-oscillator power. Potentially, superconducting HEB mixers are capable of exhibiting high sensitivity for frequencies up to several tens of THz, as their output noise and conversion gain are nearly frequency independent according to the mixing mechanism. Moreover, the understanding of mixing mechanism has evolved over time from lumped-element model to distributed hot-spot model. In this review, we provide an overview of theoretical and experimental studies on HEBs and their applications, especially in astronomical observations on ground, airborne and space telescopes.

Superconductivity•May 8, 2022•17 citations

Terahertz Superconducting Hot Electron Bolometer Heterodyne Receivers

J. R. Gao, Merlijn Hajenius, Zhenyu Yang +4 more

We highlight the progress on NbN hot electron bolometer (HEB) mixers achieved through fruitful collaboration between SRON Netherlands Institute for Space Research and Delft University of Technology, the Netherlands. This includes the best receiver noise temperatures of 700 K at 1.63 THz using a twin-slot antenna mixer and 1050 K at 2.84 THz using a spiral antenna coupled HEB mixer. The mixers are based on thin NbN films on Si and fabricated with a new contact-process and-structure. By reducing their areas HEB mixers have shown an LO power requirement as low as 30 nW. Those small HEB mixers have demonstrated equivalent sensitivity as those with large areas provided the direct detection effect due to broadband radiation is removed. To manifest that a HEB based heterodyne receiver can in practice be used at arbitrary frequencies above 2 THz, we demonstrate a 2.8 THz receiver using a THz quantum cascade laser (QCL) as local oscillator.

IEEE Transactions on Applied Superconductivity•Jun 1, 2007•28 citations
A phase-sensitive terahertz heterodyne mixer of a new type based on a cold-electron bolometer is proposed. In this mixer, a normal-metal thin-film absorber is connected to a planar antenna via superconductor-insulator-normal metal (SIN) tunnel junctions, thus forming a SINIS structure. The SINIS mixer combines the advantages of a hot-electron bolometer (HEB), such as a high signal frequency at a small local oscillator power, with the advantages of an SIS mixer, including low noise level, a high intermediate frequency, and wide working temperature range (up to a critical temperature of the superconductor). In contrast to the HEB and SIS mixers, the proposed device is less sensitive to external magnetic noise and exhibits no additional noise related to the superconducting transition and the Josephson effect.
This chapter discusses the high sensitivity superconducting mixers, i.e. detectors used in heterodyne receivers. Today, there are essentially two very successful concepts of superconducting mixers, or frequency down-converters, the superconductor-insulator-superconductor tunnel junction SIS mixer and the superconducting hot-electron bolometer mixer. Moving up to higher frequencies in the microwave and millimeter wave electromagnetic spectra makes it more and more difficult to retrieve a good signal-to-noise ratio with ordinary solid-state amplifiers. The driving force for using superconducting mixers is their excellent down-conversion efficiency and capability to down-convert RF signals from microwave frequencies up to the terahertz region. The main purpose of a receiver is to pick up and amplify a weak signal, which can then be accurately determined in amplitude and phase. The mixer noise temperature and conversion gain are the most important parameters for the mixing device. The Josephson junction mixer was one of the first suggested devices based on superconducting point contacts and later tunnel junctions.
Hot-electron bolometer (HEB) mixers are used in many low noise heterodyne radio astronomical receivers. Their noise temperature is at the level of 10–15 times the quantum limit, and their gain bandwidth is from 2 GHz to slightly more than 5 GHz depending on the type of substrate material used for a device fabrication. The HEB mixers presented in this Letter are a complex multilayer thin-film structure containing an ultra-thin superconducting film of NbN as a detecting element, and a thick normal metal layer as an antenna structure. The overall performance of the device has been improved by optimisation of the HEB mixer fabrication steps starting with ultra-thin NbN films, followed by NbN/Au bi-layers for antenna structures. Patterning was achieved using electron-beam lithography and lift-off processes. The noise temperature of the HEB mixer fabricated with the improved technology is about 800 K, as measured in a cryogenic-free system with a quantum cascade laser as a local oscillator.
Superconducting hot-electron bolometers (HEB) represent a promising candidate for heterodyne mixing at frequencies exceeding 1 THz. Nb HEB mixers offer performance competitive with tunnel junctions without the frequency limit imposed by the superconducting energy gap. Although the performance of YBa/sub 2/Cu/sub 3/O/sub 7-/spl delta// HEB mixers is not projected to be superior to that of Nb devices, which operate at low temperatures, they introduce the possibility of sensitive, low power heterodyne detectors operating at temperatures approaching 90 K for applications requiring portability and closed-cycle refrigeration. We report on the fabrication and characterization, both DC and RF, of high-T/sub c/ mixers based on ultra-thin (/spl les/20 nm) YBa/sub 2/Cu/sub 3/O/sub 7-/spl delta// films patterned to micrometer dimensions and incorporated into 2.5 THz planar mixer circuits.
The voltage response of a thin-film normal-metal hot-electron bolometer based on a SINIS (superconductor-insulator-normal metal-insulator-superconductor) structure to the radiation of a high-temperature Josephson junction in the terahertz frequency region was measured. Bolometers were integrated with planar log-periodic and double-dipole antennas, and Josephson junctions were integrated with log-periodic antennas. Measurements showed that the Josephson junction at a temperature of 260 mK was overheated by the transport current, so that its electron temperature exceeded 3 K at a bias voltage of 1 mV. The maximum response of a bolometer with a double-dipole antenna was observed at a frequency of 300 GHz, which agreed well with the calculated value. The Josephson radiation was observed at frequencies up to 1.7 THz. The voltage response of a bolometer reached 4×10 8 V/W, and the total noise-equivalent power reached 1.5×10 −17 W/Hz 1/2 .
Superconducting hot electron bolometer (HEB) mixers are the most sensitive heterodyne detectors at frequencies beyond 1 THz, and are used for many astronomical observations. HEB, consisting of a narrow and short superconducting thin film patch connected to an antenna via contact pads, is brought into a highly sensitive operating regime by applying a DC current and a certain amount of local-oscillator power. Potentially, superconducting HEB mixers are capable of exhibiting high sensitivity for frequencies up to several tens of THz, as their output noise and conversion gain are nearly frequency independent according to the mixing mechanism. Moreover, the understanding of mixing mechanism has evolved over time from lumped-element model to distributed hot-spot model. In this review, we provide an overview of theoretical and experimental studies on HEBs and their applications, especially in astronomical observations on ground, airborne and space telescopes.
We highlight the progress on NbN hot electron bolometer (HEB) mixers achieved through fruitful collaboration between SRON Netherlands Institute for Space Research and Delft University of Technology, the Netherlands. This includes the best receiver noise temperatures of 700 K at 1.63 THz using a twin-slot antenna mixer and 1050 K at 2.84 THz using a spiral antenna coupled HEB mixer. The mixers are based on thin NbN films on Si and fabricated with a new contact-process and-structure. By reducing their areas HEB mixers have shown an LO power requirement as low as 30 nW. Those small HEB mixers have demonstrated equivalent sensitivity as those with large areas provided the direct detection effect due to broadband radiation is removed. To manifest that a HEB based heterodyne receiver can in practice be used at arbitrary frequencies above 2 THz, we demonstrate a 2.8 THz receiver using a THz quantum cascade laser (QCL) as local oscillator.