arXiv:2608.22737

Transient Dynamics and Duty-Cycle Optimization in a Pulse-Wwidth Modulation Bell--Bloom Pumping

Ying-Hao Ye, Ling-Yan Hu, Dui-Gao Yi, 于志飞 Zhi-fei YU, Bing Chen

Published Aug 24, 2026• 0 citations
arXivHTMLPDF

Abstract

We investigate the duty-cycle-dependent atomic response under full-depth intensity pulse-width modulation in Bell--Bloom optical pumping. A time-domain Bloch model explicitly resolves the pump-on/off spin dynamics, yielding piecewise analytical transient solutions and a periodic steady-state description without cycle averaging or harmonic truncation. An extended free-induction-decay method independently determines the effective dark and pump-on transverse-relaxation rates, $W_0$ and $W$. The predicted lock-in responses agree well with experimental results. We find that for each Larmor frequency $ω_0$, the slope is maximized at a finite pump rate that increases with $ω_0$. These results provide a practical framework for sensitivity-oriented optimization of the duty cycle and pump rate in PWM-driven atomic magnetometers.

DOI
10.48550/arxiv.2608.22737

Related papers

Study of the optimal duty cycle and pumping rate for square-wave amplitude-modulated Bell–Bloom magnetometers

Meiling Wang, Meng-Bing Wang, Guiying Zhang +1 more

We theoretically and experimentally study the optimal duty cycle and pumping rate for square-wave amplitude-modulated Bell–Bloom magnetometers. The theoretical and the experimental results are in good agreement for duty cycles and corresponding pumping rates ranging over 2 orders of magnitude. Our study gives the maximum field response as a function of duty cycle and pumping rate. Especially, for a fixed duty cycle, the maximum field response is obtained when the time averaged pumping rate, which is the product of pumping rate and duty cycle, is equal to the transverse relaxation rate in the dark. By using a combination of small duty cycle and large pumping rate, one can increase the maximum field response by up to a factor of 2 or π /2, relative to that of the sinusoidal modulation or the 50% duty cycle square-wave modulation respectively. We further show that the same pumping condition is also practically optimal for the sensitivity due to the fact that the signal at resonance is insensitive to the fluctuations of pumping rate and duty cycle.

Chinese Physics B•Jun 1, 2016•11 citations

Close-Loop Bell–Bloom Magnetometer with Amplitude Modulation

Haichao Huang, Haifeng Dong, Hui-Jie Hao +1 more

A high sensitive optical amplitude modulation magnetometer is investigated and demonstrated experimentally. We build an experimental platform for the atomic magnetometer and configure it as a Bell–Bloom magnetometer with amplitude modulation of 50% duty cycle square waveform. The open-loop input-output model is deduced from the Bloch equation and is verified experimentally. Instead of locking the frequency by using a voltage control oscillator, we realize a closed loop using the coils to generate a feedback field which avoids the stringent requirement of a high resolution frequency meter and markedly expands the dynamic range as well as the bandwidth. We realize an open loop sensitivity of 0.8 pT/Hz 1/2 at 20 Hz using a single light beam, which exceeds that of the state-of-the-art Bell–Bloom magnetometers, and the corresponding closed loop sensitivity is 1.2 pT/Hz 1/2 .

Chinese Physics Letters•Sep 1, 2015•13 citations

Realization and Optimization of all-optical Cs atom magnetometer based on Bell-Bloom structure

Zhang Jun-ha

In order to availably solve the crosstalk of the traditionally optically pumped magnetometer,in which an oscillating magnetic field drives transitions between Zeeman magnetic sublevels,an all-optical cesium(Cs)atomic magnetometer based on Bell-Bloom structure has been investigated and demonstrated experimentally in this paper.When there is an external magnetic field,by analyzing the Larmor precession spectrum of the polarized ground state atoms induced by a modulated pump laser,the atomic magnetometer with high sensitivity is achieved.First,we present the operating principle of the magnetometer with amplitude modulation and set up the experimental system by means of a three-layer magnetic shield.Then in the case of 100 nT field by optimizing the experimental parameters,i.e.,the frequency and intensity of the pump laser,we have obtained the atomic precession spectrum with line width(full width at half maximum)of 22 Hz and signal noise ratio(SNR)of 3.2×104 per unit hertz band width,and then have evaluated the magnetometer with an intrinsic sensitivity of 100fT/Hz1/2 and spatial resolution smaller than 1.2cm,while the experimentally closed loop test shows that the cesium atomic magnetometer would have the sensitivity of 120fT/Hz1/2 and response time of 300 ms.

Journal of Optoelectronics·laser•Jan 1, 2015•0 citations

Combined effect of pump-light intensity and modulation field on the performance of optically pumped magnetometers under zero-field parametric modulation

Jing Wang, Wenfeng Fan, Kaifeng Yin +3 more

This paper investigates the performance optimization of optically pumped magnetometers under zero-field parametric modulation. Based on the analytical solutions of the Bloch equation, both longitudinal and transverse modulations are studied experimentally. To estimate the nonuniform polarization distribution of alkali-metal atoms in the vapor cell, an average pumping rate model is proposed. Furthermore, the accuracy of this model and the measurement of the transverse relaxation rate are verified via the agreement between experimental and theoretical values. The results indicate that optimal performance can be achieved by employing a suitable modulation field, the selection of which is related to the modulation index $u$ in the Bessel series and the pump-light intensity. Although both operating modes show similar responses to weak magnetic fields, their effects on pump-light intensity are different due to the means of detecting atomic polarization. An optimal value of the pump-light intensity on the response strength exists in longitudinal modulation. However, with regard to transverse modulation, the sensitivity under weak pump-light intensity is better. This research has far-reaching significance for cases when the parametric modulation is manipulated.

Physical Review A•May 19, 2020•76 citations

Influence of Pump Light’s Duty Cycle on Cesium Atomic Magnetometer

Xian Jin Zeng, Jun Hai Zhang, Qiang Liu +2 more

Recently, atomic magnetometers have been researched widely for its ultra high sensitivity. But the influence of pump light’s duty cycle on atomic magnetometers has been concerned little. In this paper, we described a sensitive cesium atomic magnetometer based on circular dichroism, which had the advantage of easily locking the probing laser to the necessary frequency. We experimentally investigated the amplitudes and linewidths of magnetic resonance signals at different modulated duty cycle of the pump light. The result indicated that our magnetometer achieved the highest sensitivity at the duty cycle of 30%. It’s valuable for optimizing the sensitivity of most atomic magnetometers.

Advanced materials research•Sep 1, 2012•2 citations

Systematic errors from scalar slowing-down models in transient SERF magnetometry

Marek Kopciuch, Harini Raghavan, Morgan W. Mitchell

Reduced Bloch models of spin-exchange-relaxation-free (SERF) magnetometers commonly describe the coupled electron--nuclear spin dynamics using a single nuclear slowing-down factor. We show that this scalar description becomes inaccurate when the polarization magnitude changes appreciably. We derive an effective Bloch equation with separate longitudinal and transverse slowing-down factors, $q_\parallel(P)$ and $q_\perp(P)$, governing changes in polarization magnitude and direction. For $^{87}\mathrm{Rb}$ under representative SERF conditions and undergoing free-induction decay (FID), comparison with master-equation simulations shows that the dynamic scalar model produces a magnetic-field estimation bias of up to $4.2\%$ at high initial polarization, while fixing the slowing-down factor at a reference value increases the error to $10.1\%$. Lowering the polarization suppresses this bias but also reduces the magnetic-field information contained in the FID signal. We further show that the anisotropic response modifies noncollinear optical pumping and introduces an additional nonlinear contribution to the harmonic response under periodic driving. The resulting model retains the simplicity of a three-component Bloch description while improving the quantitative accuracy of transient and driven SERF magnetometry.

physics.atom-phCross-listedarXiv:2609.31865•Sep 29, 2026•0 citations
We investigate the duty-cycle-dependent atomic response under full-depth intensity pulse-width modulation in Bell--Bloom optical pumping. A time-domain Bloch model explicitly resolves the pump-on/off spin dynamics, yielding piecewise analytical transient solutions and a periodic steady-state description without cycle averaging or harmonic truncation. An extended free-induction-decay method independently determines the effective dark and pump-on transverse-relaxation rates, W0W_0W0​ and WWW. The predicted lock-in responses agree well with experimental results. We find that for each Larmor frequency ω0ω_0ω0​, the slope is maximized at a finite pump rate that increases with ω0ω_0ω0​. These results provide a practical framework for sensitivity-oriented optimization of the duty cycle and pump rate in PWM-driven atomic magnetometers.
We theoretically and experimentally study the optimal duty cycle and pumping rate for square-wave amplitude-modulated Bell–Bloom magnetometers. The theoretical and the experimental results are in good agreement for duty cycles and corresponding pumping rates ranging over 2 orders of magnitude. Our study gives the maximum field response as a function of duty cycle and pumping rate. Especially, for a fixed duty cycle, the maximum field response is obtained when the time averaged pumping rate, which is the product of pumping rate and duty cycle, is equal to the transverse relaxation rate in the dark. By using a combination of small duty cycle and large pumping rate, one can increase the maximum field response by up to a factor of 2 or π /2, relative to that of the sinusoidal modulation or the 50% duty cycle square-wave modulation respectively. We further show that the same pumping condition is also practically optimal for the sensitivity due to the fact that the signal at resonance is insensitive to the fluctuations of pumping rate and duty cycle.
A high sensitive optical amplitude modulation magnetometer is investigated and demonstrated experimentally. We build an experimental platform for the atomic magnetometer and configure it as a Bell–Bloom magnetometer with amplitude modulation of 50% duty cycle square waveform. The open-loop input-output model is deduced from the Bloch equation and is verified experimentally. Instead of locking the frequency by using a voltage control oscillator, we realize a closed loop using the coils to generate a feedback field which avoids the stringent requirement of a high resolution frequency meter and markedly expands the dynamic range as well as the bandwidth. We realize an open loop sensitivity of 0.8 pT/Hz 1/2 at 20 Hz using a single light beam, which exceeds that of the state-of-the-art Bell–Bloom magnetometers, and the corresponding closed loop sensitivity is 1.2 pT/Hz 1/2 .
In order to availably solve the crosstalk of the traditionally optically pumped magnetometer,in which an oscillating magnetic field drives transitions between Zeeman magnetic sublevels,an all-optical cesium(Cs)atomic magnetometer based on Bell-Bloom structure has been investigated and demonstrated experimentally in this paper.When there is an external magnetic field,by analyzing the Larmor precession spectrum of the polarized ground state atoms induced by a modulated pump laser,the atomic magnetometer with high sensitivity is achieved.First,we present the operating principle of the magnetometer with amplitude modulation and set up the experimental system by means of a three-layer magnetic shield.Then in the case of 100 nT field by optimizing the experimental parameters,i.e.,the frequency and intensity of the pump laser,we have obtained the atomic precession spectrum with line width(full width at half maximum)of 22 Hz and signal noise ratio(SNR)of 3.2×104 per unit hertz band width,and then have evaluated the magnetometer with an intrinsic sensitivity of 100fT/Hz1/2 and spatial resolution smaller than 1.2cm,while the experimentally closed loop test shows that the cesium atomic magnetometer would have the sensitivity of 120fT/Hz1/2 and response time of 300 ms.
This paper investigates the performance optimization of optically pumped magnetometers under zero-field parametric modulation. Based on the analytical solutions of the Bloch equation, both longitudinal and transverse modulations are studied experimentally. To estimate the nonuniform polarization distribution of alkali-metal atoms in the vapor cell, an average pumping rate model is proposed. Furthermore, the accuracy of this model and the measurement of the transverse relaxation rate are verified via the agreement between experimental and theoretical values. The results indicate that optimal performance can be achieved by employing a suitable modulation field, the selection of which is related to the modulation index uuu in the Bessel series and the pump-light intensity. Although both operating modes show similar responses to weak magnetic fields, their effects on pump-light intensity are different due to the means of detecting atomic polarization. An optimal value of the pump-light intensity on the response strength exists in longitudinal modulation. However, with regard to transverse modulation, the sensitivity under weak pump-light intensity is better. This research has far-reaching significance for cases when the parametric modulation is manipulated.
Recently, atomic magnetometers have been researched widely for its ultra high sensitivity. But the influence of pump light’s duty cycle on atomic magnetometers has been concerned little. In this paper, we described a sensitive cesium atomic magnetometer based on circular dichroism, which had the advantage of easily locking the probing laser to the necessary frequency. We experimentally investigated the amplitudes and linewidths of magnetic resonance signals at different modulated duty cycle of the pump light. The result indicated that our magnetometer achieved the highest sensitivity at the duty cycle of 30%. It’s valuable for optimizing the sensitivity of most atomic magnetometers.
Reduced Bloch models of spin-exchange-relaxation-free (SERF) magnetometers commonly describe the coupled electron--nuclear spin dynamics using a single nuclear slowing-down factor. We show that this scalar description becomes inaccurate when the polarization magnitude changes appreciably. We derive an effective Bloch equation with separate longitudinal and transverse slowing-down factors, q∥(P)q_\parallel(P)q∥​(P) and q⊥(P)q_\perp(P)q⊥​(P), governing changes in polarization magnitude and direction. For 87Rb^{87}\mathrm{Rb}87Rb under representative SERF conditions and undergoing free-induction decay (FID), comparison with master-equation simulations shows that the dynamic scalar model produces a magnetic-field estimation bias of up to 4.2%4.2\%4.2% at high initial polarization, while fixing the slowing-down factor at a reference value increases the error to 10.1%10.1\%10.1%. Lowering the polarization suppresses this bias but also reduces the magnetic-field information contained in the FID signal. We further show that the anisotropic response modifies noncollinear optical pumping and introduces an additional nonlinear contribution to the harmonic response under periodic driving. The resulting model retains the simplicity of a three-component Bloch description while improving the quantitative accuracy of transient and driven SERF magnetometry.