Realization and Optimization of all-optical Cs atom magnetometer based on Bell-Bloom structure

Zhang Jun-ha

Published Jan 1, 2015• 0 citations
OpenAlex

Abstract

In order to availably solve the crosstalk of the traditionally optically pumped magnetometer,in which an oscillating magnetic field drives transitions between Zeeman magnetic sublevels,an all-optical cesium(Cs)atomic magnetometer based on Bell-Bloom structure has been investigated and demonstrated experimentally in this paper.When there is an external magnetic field,by analyzing the Larmor precession spectrum of the polarized ground state atoms induced by a modulated pump laser,the atomic magnetometer with high sensitivity is achieved.First,we present the operating principle of the magnetometer with amplitude modulation and set up the experimental system by means of a three-layer magnetic shield.Then in the case of 100 nT field by optimizing the experimental parameters,i.e.,the frequency and intensity of the pump laser,we have obtained the atomic precession spectrum with line width(full width at half maximum)of 22 Hz and signal noise ratio(SNR)of 3.2×104 per unit hertz band width,and then have evaluated the magnetometer with an intrinsic sensitivity of 100fT/Hz1/2 and spatial resolution smaller than 1.2cm,while the experimentally closed loop test shows that the cesium atomic magnetometer would have the sensitivity of 120fT/Hz1/2 and response time of 300 ms.

Related papers

Study on the sensitivity of laser-pumped cesium atomic magnetometer

Nan Li, Huang Kai-Kai, Xuanhui Lu

A cesium atomic magnetometer based on laser-pumped rf resonance has been investigated and demonstrated experimentally. Atoms are polarized and pumped to dark states by circularly polarized light. When there exists a magnetic field, the corresponding magnetization will be precessing around the magnetic field at Larmor frequency. By means of adding a resonant rf magnetic field, the atoms will be depolarized and absorb photons again. By detecting the spectrum of the transmitted light, one can obtain the information about the external magnetic field. We build an 894nm external cavity diode laser with a frequency stabilization device, and a low noise magnetic field measurement environment. After the optimization of the magnetometer parameter and closed-loop measurement, an ultimate sensitivity of 19 fT/Hz1/2 and an intrinsic sensitivity of 1.8 pT/Hz1/2 have been achieved with the spatial resolution smaller than 2 cm.

Acta Physica Sinica•Jan 1, 2013•4 citations

All-Optical Cesium Atomic Magnetometer with High Sensitivity

Jun-Hai Zhang, Qiang Liu, Xianjin Zeng +2 more

An all-optical cesium magnetometer with high sensitivity based on absorptive detection is reported. The experiment achieves a polarized rotational spectrum of the probe light which is induced by circular dichroism and a quarter wave plate together. The frequency response of the rotational spectrum is 1.8 mrad/Hz at Larmor precession resonance. Analyzing the signal-to-noise ratio from the experimentally observed spectrum, we predict that the magnetic measurement sensitivity of 0.3 pT/Hz 1/2 would be obtained in the responsive range from 20 nT to 2000 nT.

Chinese Physics Letters•Jun 1, 2012•15 citations

A highly drift-stable atomic magnetometer for fundamental physics experiments

Martin Rosner, BECK Douglas howard, P. Fierlinger +7 more

We report the design and performance of a nonmagnetic drift stable optically pumped cesium magnetometer with a measured sensitivity of 35 fT at 200 s integration time and stability below 50 fT between 70 and 600 s. The sensor is based on the nonlinear magneto-optical rotation effect: in a Bell–Bloom configuration, a higher order polarization moment (alignment) of Cs atoms is created with a pump laser beam in an anti-relaxation coated Pyrex cell under vacuum, filled with Cs vapor at room temperature. The polarization plane of light passing through the cell is modulated due the precession of the atoms in an external magnetic field of 2.1 μT, used to optically determine the Larmor precession frequency. Operation is based on a sequence of optical pumping and observation of freely precessing spins at a repetition rate of 8 Hz. This free precession decay readout scheme separates optical pumping and probing and, thus, ensures a systematically highly clean measurement. Due to the residual offset of the sensor of <15 pT together with negligible crosstalk of adjacent sensors, this device is uniquely suitable for a variety of experiments in low-energy particle physics with extreme precision, here as a highly stable and systematically clean reference probe in search for time-reversal symmetry violating electric dipole moments.

arXiv:2201.06936•Applied Physics Letters•Apr 18, 2022•30 citations

Enhanced fully optically pumped magnetic resonance with optical sideband auxiliary pumping

Zhiyuan Jiang, Xiaochi Liu, Pingwei Lin +2 more

We have proposed a new technique to obtain highly polarized atoms for improving the sensitivity of the all-optical Cs atomic magnetometer. In a Bell–Bloom magnetometer, the resonance pumping from the ground state F g = 3 to the excited state F e = 4 at the D1 line is used to polarize the Cs atoms and populate the sublevels of the | F g = 4 , m F = 4 ⟩ partly as the transition F g = 4 → F e = 3 remains leaking. Here we utilize a modulation technique to generate a sideband frequency to pump both transitions simultaneously, which drives more atoms to the target state | F g = 4 , m F = 4 ⟩ . This improvement significantly increases the magnetic resonance signal but with little effect on its linewidth. It is very suitable for the miniaturization of the atomic magnetometer in the future.

Optics Letters•Dec 17, 2019•7 citations

Vector measurements using all optical scalar atomic magnetometers

Rui Zhang, Rahul Mhaskar, Ken Smith +2 more

Vector field measurement is demonstrated with an all-optical scalar atomic magnetometer using intrinsic parameters related to its scalar operation. The Bell-Bloom type atomic magnetometer measures the Larmor precession of cesium atoms through on-resonant absorption of a probe beam. While the AC component of the probe signal is used for the field magnitude measurement, the probe DC signal contains information about the polar angle, defined as the angle between the magnetic field and the probe beam. Additional polar angle information is obtained from the light-shift-induced magnetic field caused by the frequency modulation of the probe beam. With a measurement time of 100 ms, better than 0.02° sensitivity has been achieved using a commercial miniaturized sensor at the optimal sensor orientation. The angle measurement accuracy is checked against an optical encoder over the entire polar angle range of 0°–180°. Better than 1° error is recorded over most set polar angles. Azimuthal angle measurement is also exhibited with two orthogonally oriented sensors.

arXiv:2011.08943•Journal of Applied Physics•Jan 28, 2021•17 citations

All Optical Scalar Atomic Magnetometer Capable of Vector Measurement

Rui Zhang, Rahul R. Mhaskar, Ken A. Smith +2 more

Vector field measurement is demonstrated with an all-optical scalar atomic magnetometer using intrinsic parameters related to its scalar operation. The Bell-Bloom type atomic magnetometer measures the Larmor precession of cesium atoms through on-resonant absorption of a probe beam. While the AC component of the probe signal is used for the field magnitude measurement, the probe DC signal contains information about the polar angle, defined as the angle between the magnetic field and the probe beam. Additional polar angle information is obtained from the light-shift-induced magnetic field caused by the frequency modulation of the probe beam. With a measurement time of 100 milliseconds, better than 0.02 degree sensitivity has been achieved using a commercial miniaturized sensor at the optimal sensor orientation. The angle measurement accuracy is checked against an optical encoder over the entire polar angle range of 0 to 180 degrees. Better than 1 degree error is recorded over most set polar angles. Azimuthal angle measurement is also exhibited with an additional orthogonally oriented sensor.

•Nov 17, 2020•0 citations
In order to availably solve the crosstalk of the traditionally optically pumped magnetometer,in which an oscillating magnetic field drives transitions between Zeeman magnetic sublevels,an all-optical cesium(Cs)atomic magnetometer based on Bell-Bloom structure has been investigated and demonstrated experimentally in this paper.When there is an external magnetic field,by analyzing the Larmor precession spectrum of the polarized ground state atoms induced by a modulated pump laser,the atomic magnetometer with high sensitivity is achieved.First,we present the operating principle of the magnetometer with amplitude modulation and set up the experimental system by means of a three-layer magnetic shield.Then in the case of 100 nT field by optimizing the experimental parameters,i.e.,the frequency and intensity of the pump laser,we have obtained the atomic precession spectrum with line width(full width at half maximum)of 22 Hz and signal noise ratio(SNR)of 3.2×104 per unit hertz band width,and then have evaluated the magnetometer with an intrinsic sensitivity of 100fT/Hz1/2 and spatial resolution smaller than 1.2cm,while the experimentally closed loop test shows that the cesium atomic magnetometer would have the sensitivity of 120fT/Hz1/2 and response time of 300 ms.
A cesium atomic magnetometer based on laser-pumped rf resonance has been investigated and demonstrated experimentally. Atoms are polarized and pumped to dark states by circularly polarized light. When there exists a magnetic field, the corresponding magnetization will be precessing around the magnetic field at Larmor frequency. By means of adding a resonant rf magnetic field, the atoms will be depolarized and absorb photons again. By detecting the spectrum of the transmitted light, one can obtain the information about the external magnetic field. We build an 894nm external cavity diode laser with a frequency stabilization device, and a low noise magnetic field measurement environment. After the optimization of the magnetometer parameter and closed-loop measurement, an ultimate sensitivity of 19 fT/Hz1/2 and an intrinsic sensitivity of 1.8 pT/Hz1/2 have been achieved with the spatial resolution smaller than 2 cm.
An all-optical cesium magnetometer with high sensitivity based on absorptive detection is reported. The experiment achieves a polarized rotational spectrum of the probe light which is induced by circular dichroism and a quarter wave plate together. The frequency response of the rotational spectrum is 1.8 mrad/Hz at Larmor precession resonance. Analyzing the signal-to-noise ratio from the experimentally observed spectrum, we predict that the magnetic measurement sensitivity of 0.3 pT/Hz 1/2 would be obtained in the responsive range from 20 nT to 2000 nT.
We report the design and performance of a nonmagnetic drift stable optically pumped cesium magnetometer with a measured sensitivity of 35 fT at 200 s integration time and stability below 50 fT between 70 and 600 s. The sensor is based on the nonlinear magneto-optical rotation effect: in a Bell–Bloom configuration, a higher order polarization moment (alignment) of Cs atoms is created with a pump laser beam in an anti-relaxation coated Pyrex cell under vacuum, filled with Cs vapor at room temperature. The polarization plane of light passing through the cell is modulated due the precession of the atoms in an external magnetic field of 2.1 μT, used to optically determine the Larmor precession frequency. Operation is based on a sequence of optical pumping and observation of freely precessing spins at a repetition rate of 8 Hz. This free precession decay readout scheme separates optical pumping and probing and, thus, ensures a systematically highly clean measurement. Due to the residual offset of the sensor of <15 pT together with negligible crosstalk of adjacent sensors, this device is uniquely suitable for a variety of experiments in low-energy particle physics with extreme precision, here as a highly stable and systematically clean reference probe in search for time-reversal symmetry violating electric dipole moments.
We have proposed a new technique to obtain highly polarized atoms for improving the sensitivity of the all-optical Cs atomic magnetometer. In a Bell–Bloom magnetometer, the resonance pumping from the ground state F g = 3 to the excited state F e = 4 at the D1 line is used to polarize the Cs atoms and populate the sublevels of the | F g = 4 , m F = 4 ⟩ partly as the transition F g = 4 → F e = 3 remains leaking. Here we utilize a modulation technique to generate a sideband frequency to pump both transitions simultaneously, which drives more atoms to the target state | F g = 4 , m F = 4 ⟩ . This improvement significantly increases the magnetic resonance signal but with little effect on its linewidth. It is very suitable for the miniaturization of the atomic magnetometer in the future.
Vector field measurement is demonstrated with an all-optical scalar atomic magnetometer using intrinsic parameters related to its scalar operation. The Bell-Bloom type atomic magnetometer measures the Larmor precession of cesium atoms through on-resonant absorption of a probe beam. While the AC component of the probe signal is used for the field magnitude measurement, the probe DC signal contains information about the polar angle, defined as the angle between the magnetic field and the probe beam. Additional polar angle information is obtained from the light-shift-induced magnetic field caused by the frequency modulation of the probe beam. With a measurement time of 100 ms, better than 0.02° sensitivity has been achieved using a commercial miniaturized sensor at the optimal sensor orientation. The angle measurement accuracy is checked against an optical encoder over the entire polar angle range of 0°–180°. Better than 1° error is recorded over most set polar angles. Azimuthal angle measurement is also exhibited with two orthogonally oriented sensors.
Vector field measurement is demonstrated with an all-optical scalar atomic magnetometer using intrinsic parameters related to its scalar operation. The Bell-Bloom type atomic magnetometer measures the Larmor precession of cesium atoms through on-resonant absorption of a probe beam. While the AC component of the probe signal is used for the field magnitude measurement, the probe DC signal contains information about the polar angle, defined as the angle between the magnetic field and the probe beam. Additional polar angle information is obtained from the light-shift-induced magnetic field caused by the frequency modulation of the probe beam. With a measurement time of 100 milliseconds, better than 0.02 degree sensitivity has been achieved using a commercial miniaturized sensor at the optimal sensor orientation. The angle measurement accuracy is checked against an optical encoder over the entire polar angle range of 0 to 180 degrees. Better than 1 degree error is recorded over most set polar angles. Azimuthal angle measurement is also exhibited with an additional orthogonally oriented sensor.