Physical Review A

Combined effect of pump-light intensity and modulation field on the performance of optically pumped magnetometers under zero-field parametric modulation

Jing Wang, Wenfeng Fan, Kaifeng Yin, Yeguang Yan, Binquan Zhou, Xinda Song

Published May 19, 2020• 75 citations
Publisher

Abstract

This paper investigates the performance optimization of optically pumped magnetometers under zero-field parametric modulation. Based on the analytical solutions of the Bloch equation, both longitudinal and transverse modulations are studied experimentally. To estimate the nonuniform polarization distribution of alkali-metal atoms in the vapor cell, an average pumping rate model is proposed. Furthermore, the accuracy of this model and the measurement of the transverse relaxation rate are verified via the agreement between experimental and theoretical values. The results indicate that optimal performance can be achieved by employing a suitable modulation field, the selection of which is related to the modulation index $u$ in the Bessel series and the pump-light intensity. Although both operating modes show similar responses to weak magnetic fields, their effects on pump-light intensity are different due to the means of detecting atomic polarization. An optimal value of the pump-light intensity on the response strength exists in longitudinal modulation. However, with regard to transverse modulation, the sensitivity under weak pump-light intensity is better. This research has far-reaching significance for cases when the parametric modulation is manipulated.

DOI
10.1103/physreva.101.053427

Related papers

Optimal Magneto‐Optical Angle in Single‐Beam Optically Pumped Atomic Magnetometers Considering the Spatial Distribution of Spin Polarization

Yuntian Zou, Chi Fang, Jiali Liu +7 more

ABSTRACT Single‐beam optically pumped atomic magnetometers (OPAMs) are promising tools for biomagnetic measurements in nonzero‐field environments owing to their high sensitivity and compactness. However, the angle between the external bias magnetic field and the pump light affects the spin polarization of the atomic ensemble, thereby influencing the magnetometer performance and making the optimization of the magneto‐optical angle essential. In this study, a spatially resolved steady‐state spin polarization model incorporating the magneto‐optical angle is established for the first time, and an analytical expression of the spin precession signal under RF magnetic field excitation is derived. It is demonstrated that an optimal angle exists at which the magnetometer exhibits the maximum response and the highest sensitivity, which is experimentally determined to be 26° in our single‐beam OPAM. At this angle, the combined influence of the steady‐state spin polarization, spin precession projection, transmitted light intensity, and transverse spin relaxation reaches an optimal overall state, leading to a 14% enhancement in sensitivity and a 32% reduction in detection noise compared with the conventional 45° configuration. These findings provide guidance for optimizing the experimental parameters of single‐beam OPAMs for weak magnetic signal detection in nonzero‐field environments.

Advanced Quantum Technologies•Jan 1, 2026•1 citation

Influence of skew light propagation on electron spin polarization in an atomic magnetometer

Zekun Wu, Yuchen Jia, Zhen Chai +1 more

Atomics magnetometers achieve remarkable accuracy, applying to production and scientific research. However, their size and bulk components make it difficult to achieve higher accuracy. We investigate the influence of the skew angle of the pump beam on the optical pumping rate in an atomic magnetometer. An analysis based on the Bloch equation is proposed to decrease evaluate optical errors in the process of production and assembly. When the incident angle is non-zero, the pumping rate has a projection in the direction of a static magnetic field. By establishing the pumping rate equation, the pumping rate of each position in the vapor cell in the direction of static magnetic field at different pump light skew angles is calculated in our study. The sensitivity was measured experimentally to demonstrate the simulation results. The results indicate that the optical pumping rate decreases as the amplitude of skew angle and propagation distance increasing which can be evaluated by one-dimensional distribution while the decay rate increases with the rise of the angle. The simulation values of the rubidium pumping rate, obtained with an incident angle of 0.5° , in the center of the vapor cell are reduced by 46%. The sensitivity decreases with the increasing skew angle similar to the attenuation trend of the optical pumping rate but not the same. Our work provides a reference for evaluating the optical error of atomic magnetometer which is useful for miniaturization design.

Optics Frontier Conference (OFS)•Jun 18, 2021•4 citations

In-Situ Relaxation Rate Measurement in Magnetic Modulated Atomic Magnetometers

Kaifeng Yin, Binquan Zhou, Jixi Lu +4 more

Traditional practice of suppressing low-frequency noise in atomic magnetometers is mainly through the application of magnetic field modulation, while magnetic fields of this kind introduce extra transverse relaxation, which results in a decrease of sensitivity. In this study, a novel method of measuring relaxation rate induced by spin-destruction, wall collisions and modulation magnetic fields is proposed. The optical pumping model is studied both in optical-thin and optical-thick vapor cell through the analysis of total relaxation, thus the optical pumping rate can be separated from total relaxation by analyzing the optical depth. Furthermore, based on the analysis of optical pumping rate and relaxation rate, the polarization of the electron ensemble was evaluated. A compact magnetometer with single-beam configuration is developed for the proof of concept, and the experimental results show good agreements with theoretical calculation. Our method provides a simple and feasible approach to in-situ measurement of transverse relaxation rate and optical pumping rate with physical structure of the device untouched, which is especially advantageous for designing and optimizing compact atomic magnetometers.

IEEE Sensors Journal•Nov 30, 2021•14 citations

Multi-objective Optimization for SERF Atomic Magnetometer using Zero-field Parameter Modulation

Shushan Gao, Bangcheng Han, Zhuo Shi +5 more

The spin-exchange relaxation-free (SERF) atomic magnetometers exhibit ultrahigh sensitivity for the magnetic field measurement, and their performance is further enhanced through zero-field parameter modulation. However, this modulation introduces additional parameter coupling that limits the performance of magnetometers in multi-axis measurement. In this paper, we develop a modified dual-axis output equation based on the nonlinear interaction between the optical pumping rate and modulation field amplitude, mediated by the spin-exchange relaxation and polarization. We employ a multi-objective optimization algorithm incorporating the implicit constraints among these parameters to enable efficient, simultaneous optimization of both the pump rate and modulation amplitude. Experimental results show that under optimal parameters obtained by the algorithm, the dual-axis signal responses improve by approximately 20% and 30% over conventional optimization methods, achieving 2.5 fT/Hz1/2magnetic measurement sensitivities for the y-axis and 4.0 fT/Hz1/2for the x-axis, respectively.

IEEE International Conference on Electronic Measurement & Instruments•Aug 22, 2025•0 citations

Optimization and vectorization of an Mz-type optically pumped rubidium magnetometer

Zhengyu Su, Yang Li, Yongbiao Yang +3 more

Optically pumped magnetometers (OPMs) have demonstrated significant potential in weak magnetic field detection due to their high sensitivity. In this study, we developed an Mz-type optically pumped rubidium magnetometer using a paraffin-coated anti-relaxation vapor cell. The system optimization and performance characterization were conducted inside a magnetic shield. Specifically, the pump light intensity and radio-frequency (RF) magnetic field were jointly optimized by using the linewidth-amplitude ratio as the core metric. Based on the frequency-domain noise spectrum, the sensitivity in open-loop mode was measured to be approximately 30.8pT/Hz 1/2 . Furthermore, a closed-loop feedback locking technique was applied, reducing the measured noise floor under the tested conditions and improving the sensitivity to 22.9pT/Hz 1/2 , with a measured −3dB bandwidth of 123 Hz. The dynamic characteristics were evaluated via magnetic-field step response, showing that the system could track magnetic-field changes stably under closed-loop operation. Finally, by using tri-axial modulation and frequency-domain demodulation, we overcame the scalar measurement limitation of traditional Mz magnetometers. This work realizes vector magnetic field detection and provides a technical basis for applications such as geomagnetic navigation and magnetic anomaly detection.

Journal of the Optical Society of America B•Jun 24, 2026•1 citation

Detuned square-wave optical modulation zero-field atomic magnetometer

Xiaoyu Li, Bangcheng Han, Jixi Lu +2 more

In recent years, arrayed atomic magnetometers have been continuously applied in biomagnetic scenarios. However, the crosstalk between adjacent sensors introduced by the modulated magnetic fields significantly compromises the imaging accuracy of arrayed atomic magnetometers. To solve this problem, a detuned square-wave optical modulation zero-field atomic magnetometer configuration is developed and we provide an analytical solution of this method. In this scheme, the circularly polarized pump light is used to polarize alkali metal atoms longitudinally, and a beam of detuned square-wave modulated circularly polarized light is applied transversely to generate a light-shift modulation instead of the coil-generated modulated magnetic field. Then the transverse magnetic field is measured by the optical absorption method of longitudinally circularly polarized pump light. This scheme maintains the inherent advantage of high sensitivity in spinexchange relaxation-free (SERF) atomic magnetometers. Additionally, the all-optical configuration eliminates the need for additional modulated magnetic fields or radio frequency (RF) fields, thereby mitigating crosstalk issues associated with modulated magnetic fields in array applications. Consequently, this scheme exhibits great potential for arraying and is expected to be employed in magnetocardiography (MCG) and magnetoencephalography (MEG).

Optics Young Scientist Summit (OYSS)•Dec 29, 2023•0 citations
This paper investigates the performance optimization of optically pumped magnetometers under zero-field parametric modulation. Based on the analytical solutions of the Bloch equation, both longitudinal and transverse modulations are studied experimentally. To estimate the nonuniform polarization distribution of alkali-metal atoms in the vapor cell, an average pumping rate model is proposed. Furthermore, the accuracy of this model and the measurement of the transverse relaxation rate are verified via the agreement between experimental and theoretical values. The results indicate that optimal performance can be achieved by employing a suitable modulation field, the selection of which is related to the modulation index uuu in the Bessel series and the pump-light intensity. Although both operating modes show similar responses to weak magnetic fields, their effects on pump-light intensity are different due to the means of detecting atomic polarization. An optimal value of the pump-light intensity on the response strength exists in longitudinal modulation. However, with regard to transverse modulation, the sensitivity under weak pump-light intensity is better. This research has far-reaching significance for cases when the parametric modulation is manipulated.
ABSTRACT Single‐beam optically pumped atomic magnetometers (OPAMs) are promising tools for biomagnetic measurements in nonzero‐field environments owing to their high sensitivity and compactness. However, the angle between the external bias magnetic field and the pump light affects the spin polarization of the atomic ensemble, thereby influencing the magnetometer performance and making the optimization of the magneto‐optical angle essential. In this study, a spatially resolved steady‐state spin polarization model incorporating the magneto‐optical angle is established for the first time, and an analytical expression of the spin precession signal under RF magnetic field excitation is derived. It is demonstrated that an optimal angle exists at which the magnetometer exhibits the maximum response and the highest sensitivity, which is experimentally determined to be 26° in our single‐beam OPAM. At this angle, the combined influence of the steady‐state spin polarization, spin precession projection, transmitted light intensity, and transverse spin relaxation reaches an optimal overall state, leading to a 14% enhancement in sensitivity and a 32% reduction in detection noise compared with the conventional 45° configuration. These findings provide guidance for optimizing the experimental parameters of single‐beam OPAMs for weak magnetic signal detection in nonzero‐field environments.
Atomics magnetometers achieve remarkable accuracy, applying to production and scientific research. However, their size and bulk components make it difficult to achieve higher accuracy. We investigate the influence of the skew angle of the pump beam on the optical pumping rate in an atomic magnetometer. An analysis based on the Bloch equation is proposed to decrease evaluate optical errors in the process of production and assembly. When the incident angle is non-zero, the pumping rate has a projection in the direction of a static magnetic field. By establishing the pumping rate equation, the pumping rate of each position in the vapor cell in the direction of static magnetic field at different pump light skew angles is calculated in our study. The sensitivity was measured experimentally to demonstrate the simulation results. The results indicate that the optical pumping rate decreases as the amplitude of skew angle and propagation distance increasing which can be evaluated by one-dimensional distribution while the decay rate increases with the rise of the angle. The simulation values of the rubidium pumping rate, obtained with an incident angle of 0.5° , in the center of the vapor cell are reduced by 46%. The sensitivity decreases with the increasing skew angle similar to the attenuation trend of the optical pumping rate but not the same. Our work provides a reference for evaluating the optical error of atomic magnetometer which is useful for miniaturization design.
Traditional practice of suppressing low-frequency noise in atomic magnetometers is mainly through the application of magnetic field modulation, while magnetic fields of this kind introduce extra transverse relaxation, which results in a decrease of sensitivity. In this study, a novel method of measuring relaxation rate induced by spin-destruction, wall collisions and modulation magnetic fields is proposed. The optical pumping model is studied both in optical-thin and optical-thick vapor cell through the analysis of total relaxation, thus the optical pumping rate can be separated from total relaxation by analyzing the optical depth. Furthermore, based on the analysis of optical pumping rate and relaxation rate, the polarization of the electron ensemble was evaluated. A compact magnetometer with single-beam configuration is developed for the proof of concept, and the experimental results show good agreements with theoretical calculation. Our method provides a simple and feasible approach to in-situ measurement of transverse relaxation rate and optical pumping rate with physical structure of the device untouched, which is especially advantageous for designing and optimizing compact atomic magnetometers.
The spin-exchange relaxation-free (SERF) atomic magnetometers exhibit ultrahigh sensitivity for the magnetic field measurement, and their performance is further enhanced through zero-field parameter modulation. However, this modulation introduces additional parameter coupling that limits the performance of magnetometers in multi-axis measurement. In this paper, we develop a modified dual-axis output equation based on the nonlinear interaction between the optical pumping rate and modulation field amplitude, mediated by the spin-exchange relaxation and polarization. We employ a multi-objective optimization algorithm incorporating the implicit constraints among these parameters to enable efficient, simultaneous optimization of both the pump rate and modulation amplitude. Experimental results show that under optimal parameters obtained by the algorithm, the dual-axis signal responses improve by approximately 20% and 30% over conventional optimization methods, achieving 2.5 fT/Hz1/2magnetic measurement sensitivities for the y-axis and 4.0 fT/Hz1/2for the x-axis, respectively.
Optically pumped magnetometers (OPMs) have demonstrated significant potential in weak magnetic field detection due to their high sensitivity. In this study, we developed an Mz-type optically pumped rubidium magnetometer using a paraffin-coated anti-relaxation vapor cell. The system optimization and performance characterization were conducted inside a magnetic shield. Specifically, the pump light intensity and radio-frequency (RF) magnetic field were jointly optimized by using the linewidth-amplitude ratio as the core metric. Based on the frequency-domain noise spectrum, the sensitivity in open-loop mode was measured to be approximately 30.8pT/Hz 1/2 . Furthermore, a closed-loop feedback locking technique was applied, reducing the measured noise floor under the tested conditions and improving the sensitivity to 22.9pT/Hz 1/2 , with a measured −3dB bandwidth of 123 Hz. The dynamic characteristics were evaluated via magnetic-field step response, showing that the system could track magnetic-field changes stably under closed-loop operation. Finally, by using tri-axial modulation and frequency-domain demodulation, we overcame the scalar measurement limitation of traditional Mz magnetometers. This work realizes vector magnetic field detection and provides a technical basis for applications such as geomagnetic navigation and magnetic anomaly detection.
In recent years, arrayed atomic magnetometers have been continuously applied in biomagnetic scenarios. However, the crosstalk between adjacent sensors introduced by the modulated magnetic fields significantly compromises the imaging accuracy of arrayed atomic magnetometers. To solve this problem, a detuned square-wave optical modulation zero-field atomic magnetometer configuration is developed and we provide an analytical solution of this method. In this scheme, the circularly polarized pump light is used to polarize alkali metal atoms longitudinally, and a beam of detuned square-wave modulated circularly polarized light is applied transversely to generate a light-shift modulation instead of the coil-generated modulated magnetic field. Then the transverse magnetic field is measured by the optical absorption method of longitudinally circularly polarized pump light. This scheme maintains the inherent advantage of high sensitivity in spinexchange relaxation-free (SERF) atomic magnetometers. Additionally, the all-optical configuration eliminates the need for additional modulated magnetic fields or radio frequency (RF) fields, thereby mitigating crosstalk issues associated with modulated magnetic fields in array applications. Consequently, this scheme exhibits great potential for arraying and is expected to be employed in magnetocardiography (MCG) and magnetoencephalography (MEG).