Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2411.00162

In-situ electro-optic sampling of microwave signals under cryogenic conditions and for superconducting applications

Shekhar Priyadarshi, Ferizaj, Rinis, Oliver Kieler, Alexander Fernández Scarioni, Judith Felgner, Abdulrahman H. A. Widaa, J. Kohlmann, Thomas Fordell, J. Nissilä, A. Kemppinen, Mark Bieler

Published Oct 31, 2024• 0 citations
arXivHTMLPDF

Abstract

We demonstrate a cryogenic electro-optic sampling (EOS) setup that allows for the measurement of microwave signals at arbitrary positions on a cryogenic chip-scale device. We use a Josephson Arbitrary Waveform Synthesizer (JAWS) to generate quantum-accurate voltage signals and measure them with the EOS setup, allowing for the calibration of its response, yielding traceability of the microwave measurements to a quantum standard. We use the EOS setup to determine the time-domain response of ultrafast cryogenic photodiodes and the electrical reflection coefficient, i.e., the S11 scattering parameter, in a superconducting transmission line. Finally, we introduce an optical femtosecond pulse source which can be used to study the fidelity of superconducting transmission lines and terminations, as well as reflections from elements like Josephson junction arrays imbedded in them.

DOI
10.48550/arxiv.2411.00162

Related papers

In-situ electro-optic sampling of microwave signals applied to superconducting circuits

Shekhar Priyadarshi, Oliver Kieler, Alexander Fernández Scarioni +5 more

We report on electro-optic sampling (EOS) of microwave signals under cryogenic conditions employing a fully fiber-coupled measurement scheme. We use this setup to characterize the time response of ultrafast photodiodes at a temperature of 4 K. We additionally integrate a Josephson Arbitrary Waveform Synthesizer (JAWS) to the EOS platform, which allows us to calibrate the EOS response, yielding traceability of the microwave measurements to a quantum standard. Finally, we determine the electrical reflection coefficient, i.e., the S11 scattering parameter, in a Niobium transmission line using EOS at different positions. Our work denotes an important step for traceable in-situ microwave measurements in superconducting circuits.

Conference on Precision Electromagnetic Measurements•Jul 8, 2024•0 citations

Cryogenic Characterization of a Superconductor Quantum-Based Microwave Reference Source for Communications and Quantum Information

Alírio Boaventura, Justus A. Brevik, Dylan Forrest Williams +6 more

We are developing a new instrument, the RF Josephson arbitrary waveform synthesizer (RF-JAWS), for communications metrology and quantum information applications. An important aspect of the RF-JAWS design is the accurate and traceable characterization of its superconducting devices. In this article, we present a procedure for characterizing microwave superconducting devices in a cryogenic RF probe station via a vector network analyzer (VNA) calibrated with a custom cryogenic calibration kit colocated with the superconducting device under test (DUT) in the cryogenic environment. By de-embedding lossy and dispersive RF interconnects linking the superconducting DUT to the measurement apparatus at room temperature, we characterize the DUT exactly at the cryogenic on-wafer reference plane. More importantly, we operate our VNA with an external modulated source and our procedure features metrology-grade multiline thru-reflect-line calibration and absolute power and phase corrections, as opposed to the more common relative scattering-parameter correction. In addition, we apply anX-parameter model to account for impedance mismatch in cryogenic Josephson microwave sources. Our techniques are also suitable for cryogenic characterization of microwave superconducting devices for solid-state quantum computers and could help to optimize the quantum-classical interfaces in these systems.

IEEE Transactions on Applied Superconductivity•Oct 13, 2021•8 citations

Quantum-Based Modulated Microwave Waveforms

Akim A. Babenko, Nathan E. Flowers-Jacobs, Anna E. Fox +3 more

This article presents a superconducting voltage source that generates modulated microwave waveforms with quantum-based stability. The voltage source—an RF Josephson Arbitrary Waveform Synthesizer (RF-JAWS)—uses a superconducting IC with an array of 4500 series-connected Josephson junctions (JJs) that are embedded in a coplanar waveguide (CPW) transmission line. The JJs are driven with 100-ps wide current pulses that force each JJ to generate voltage pulses with a quantized integrated area. A pulse sequence is created using a delta-sigma ($\Delta $–$\Sigma $) algorithm to generate a 101-tone waveform with a 40-MHz instantaneous bandwidth around 1005 MHz with a flat power distribution of −53 dBm and a Schroeder phase distribution. The JJ’s quantum-based nonlinearity produces an amplitude stability with respect to various drive and bias parameters of ±0.005 dB and a detrended phase stability of ±0.05°. The stability of the source is verified without the need for calibrated measurements. Another$\Delta $–$\Sigma $pulse sequence generates a 10-MHz quadrature-phase shift-keying (QPSK) waveform on a 1005-MHz carrier that has the same stability and the mean error vector magnitude (EVM) of −48 dB. This work is a step toward creating a quantum-based reference source for power and cross-frequency phase calibrations, as well as a reference-modulated signal source for calibrating telecommunication links.

IEEE Transactions on Microwave Theory and Techniques•Aug 4, 2023•5 citations

Microwave Modeling and Characterization of Superconductive Circuits for Quantum Voltage Standard Applications at 4 K

Alírio Boaventura, Dylan Forrest Williams, Richard Chamberlin +6 more

In this article, we characterize the microwave behavior of superconductive circuits for quantum voltage standard applications at 4 K. For that, we develop a cryogenic multiline thru-reflect-line (TRL) calibration procedure to calibrate the microwave measurements at the 4 K on-wafer reference plane. We model superconductive circuits, including a Josephson array transmission line, compare simulated to TRL-calibrated measured results, and find excellent agreement up to 50 GHz.

IEEE Transactions on Applied Superconductivity•Jan 1, 2020•16 citations

Cryogenic Calibration of the RF Josephson Arbitrary Waveform Synthesizer

Justus A. Brevik, Alírio Boaventura, Akim A. Babenko +7 more

We performed a preliminary calibrated measurement of the output power of a Josephson arbitrary waveform synthesizer up to 1 GHz. We present the results and measurement procedure for generating quantum-based signals using an array of Josephson junctions operating at cryogenic temperature and calibrating those signals to transfer the on-wafer quantum-based accuracy to room temperature.

Conference on Precision Electromagnetic Measurements•Aug 1, 2020•12 citations

Cryogenic On-Chip In Situ S -Parameter Calibration Using Superconducting Coplanar Waveguides

Jeremy N. Thomas, Johannes Paul Hoffmann, Nathan E. Flowers-Jacobs +5 more

This article presents a new multiimpedance-state line (MISL) in situ scattering parameter (S-parameter) calibration technique using on-chip superconducting transmission lines at 4 K that enables cryogenic calibration in a fixed signal path without the need for cryogenic switches or a cryogenic probe station. The method uses coplanar waveguide (CPW) models based on various impedance states of niobium (Nb), which has zero dc resistance below 9 K and a monotonically increasing resistance from 10 K to room temperature. The different impedance states are accessed by heating the 4 K stage of a cryostat and injecting up to 245 mA of current into the line. Using these states, we solve for the unknowns in an eight-term error model through a least-squares analysis. We first validate the MISL calibration technique by comparing it with short-open-load-reciprocal (SOLR) calibrated measurements in a cryogenic probe station, finding transmission agreement within 0.2 dB and uncertainty overlap for nearly all frequencies up to 26.5 GHz. We then apply the method to calibrate Nb CPWs with and without embedded Josephson junctions (JJs), using a fixed wire bonded connection, and without the use of cryogenic switches or movable probes. Strong agreement with the CPW models is demonstrated, with uncertainty overlap and differences below 0.1 dB up to 4.6 GHz without JJs and up to 2.4 GHz with JJs; resonances cause interruptions beyond these frequencies.

IEEE Transactions on Microwave Theory and Techniques•Jul 16, 2025•0 citations
We demonstrate a cryogenic electro-optic sampling (EOS) setup that allows for the measurement of microwave signals at arbitrary positions on a cryogenic chip-scale device. We use a Josephson Arbitrary Waveform Synthesizer (JAWS) to generate quantum-accurate voltage signals and measure them with the EOS setup, allowing for the calibration of its response, yielding traceability of the microwave measurements to a quantum standard. We use the EOS setup to determine the time-domain response of ultrafast cryogenic photodiodes and the electrical reflection coefficient, i.e., the S11 scattering parameter, in a superconducting transmission line. Finally, we introduce an optical femtosecond pulse source which can be used to study the fidelity of superconducting transmission lines and terminations, as well as reflections from elements like Josephson junction arrays imbedded in them.
We report on electro-optic sampling (EOS) of microwave signals under cryogenic conditions employing a fully fiber-coupled measurement scheme. We use this setup to characterize the time response of ultrafast photodiodes at a temperature of 4 K. We additionally integrate a Josephson Arbitrary Waveform Synthesizer (JAWS) to the EOS platform, which allows us to calibrate the EOS response, yielding traceability of the microwave measurements to a quantum standard. Finally, we determine the electrical reflection coefficient, i.e., the S11 scattering parameter, in a Niobium transmission line using EOS at different positions. Our work denotes an important step for traceable in-situ microwave measurements in superconducting circuits.
We are developing a new instrument, the RF Josephson arbitrary waveform synthesizer (RF-JAWS), for communications metrology and quantum information applications. An important aspect of the RF-JAWS design is the accurate and traceable characterization of its superconducting devices. In this article, we present a procedure for characterizing microwave superconducting devices in a cryogenic RF probe station via a vector network analyzer (VNA) calibrated with a custom cryogenic calibration kit colocated with the superconducting device under test (DUT) in the cryogenic environment. By de-embedding lossy and dispersive RF interconnects linking the superconducting DUT to the measurement apparatus at room temperature, we characterize the DUT exactly at the cryogenic on-wafer reference plane. More importantly, we operate our VNA with an external modulated source and our procedure features metrology-grade multiline thru-reflect-line calibration and absolute power and phase corrections, as opposed to the more common relative scattering-parameter correction. In addition, we apply anX-parameter model to account for impedance mismatch in cryogenic Josephson microwave sources. Our techniques are also suitable for cryogenic characterization of microwave superconducting devices for solid-state quantum computers and could help to optimize the quantum-classical interfaces in these systems.
This article presents a superconducting voltage source that generates modulated microwave waveforms with quantum-based stability. The voltage source—an RF Josephson Arbitrary Waveform Synthesizer (RF-JAWS)—uses a superconducting IC with an array of 4500 series-connected Josephson junctions (JJs) that are embedded in a coplanar waveguide (CPW) transmission line. The JJs are driven with 100-ps wide current pulses that force each JJ to generate voltage pulses with a quantized integrated area. A pulse sequence is created using a delta-sigma ($\Delta –––\Sigma )algorithmtogeneratea101−tonewaveformwitha40−MHzinstantaneousbandwidtharound1005MHzwithaflatpowerdistributionof−53dBmandaSchroederphasedistribution.TheJJ’squantum−basednonlinearityproducesanamplitudestabilitywithrespecttovariousdriveandbiasparametersof±0.005dBandadetrendedphasestabilityof±0.05°.Thestabilityofthesourceisverifiedwithouttheneedforcalibratedmeasurements.Another) algorithm to generate a 101-tone waveform with a 40-MHz instantaneous bandwidth around 1005 MHz with a flat power distribution of −53 dBm and a Schroeder phase distribution. The JJ’s quantum-based nonlinearity produces an amplitude stability with respect to various drive and bias parameters of ±0.005 dB and a detrended phase stability of ±0.05°. The stability of the source is verified without the need for calibrated measurements. Another)algorithmtogeneratea101−tonewaveformwitha40−MHzinstantaneousbandwidtharound1005MHzwithaflatpowerdistributionof−53dBmandaSchroederphasedistribution.TheJJ’squantum−basednonlinearityproducesanamplitudestabilitywithrespecttovariousdriveandbiasparametersof±0.005dBandadetrendedphasestabilityof±0.05°.Thestabilityofthesourceisverifiedwithouttheneedforcalibratedmeasurements.Another\Delta –––\Sigma $pulse sequence generates a 10-MHz quadrature-phase shift-keying (QPSK) waveform on a 1005-MHz carrier that has the same stability and the mean error vector magnitude (EVM) of −48 dB. This work is a step toward creating a quantum-based reference source for power and cross-frequency phase calibrations, as well as a reference-modulated signal source for calibrating telecommunication links.
This article presents a new multiimpedance-state line (MISL) in situ scattering parameter (S-parameter) calibration technique using on-chip superconducting transmission lines at 4 K that enables cryogenic calibration in a fixed signal path without the need for cryogenic switches or a cryogenic probe station. The method uses coplanar waveguide (CPW) models based on various impedance states of niobium (Nb), which has zero dc resistance below 9 K and a monotonically increasing resistance from 10 K to room temperature. The different impedance states are accessed by heating the 4 K stage of a cryostat and injecting up to 245 mA of current into the line. Using these states, we solve for the unknowns in an eight-term error model through a least-squares analysis. We first validate the MISL calibration technique by comparing it with short-open-load-reciprocal (SOLR) calibrated measurements in a cryogenic probe station, finding transmission agreement within 0.2 dB and uncertainty overlap for nearly all frequencies up to 26.5 GHz. We then apply the method to calibrate Nb CPWs with and without embedded Josephson junctions (JJs), using a fixed wire bonded connection, and without the use of cryogenic switches or movable probes. Strong agreement with the CPW models is demonstrated, with uncertainty overlap and differences below 0.1 dB up to 4.6 GHz without JJs and up to 2.4 GHz with JJs; resonances cause interruptions beyond these frequencies.