Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE Transactions on Applied Superconductivity

Cryogenic Characterization of a Superconductor Quantum-Based Microwave Reference Source for Communications and Quantum Information

Alírio Boaventura, Justus A. Brevik, Dylan Forrest Williams, Nathan E. Flowers-Jacobs, Manuel A. Castellanos-Beltran, Anna E. Fox, P. F. Hopkins, Paul D. Dresselhaus, Samuel P. Benz

Published Oct 13, 2021• 9 citations
Publisher

Abstract

We are developing a new instrument, the RF Josephson arbitrary waveform synthesizer (RF-JAWS), for communications metrology and quantum information applications. An important aspect of the RF-JAWS design is the accurate and traceable characterization of its superconducting devices. In this article, we present a procedure for characterizing microwave superconducting devices in a cryogenic RF probe station via a vector network analyzer (VNA) calibrated with a custom cryogenic calibration kit colocated with the superconducting device under test (DUT) in the cryogenic environment. By de-embedding lossy and dispersive RF interconnects linking the superconducting DUT to the measurement apparatus at room temperature, we characterize the DUT exactly at the cryogenic on-wafer reference plane. More importantly, we operate our VNA with an external modulated source and our procedure features metrology-grade multiline thru-reflect-line calibration and absolute power and phase corrections, as opposed to the more common relative scattering-parameter correction. In addition, we apply anX-parameter model to account for impedance mismatch in cryogenic Josephson microwave sources. Our techniques are also suitable for cryogenic characterization of microwave superconducting devices for solid-state quantum computers and could help to optimize the quantum-classical interfaces in these systems.

DOI
10.1109/tasc.2021.3117610

Related papers

Cryogenic Calibration of a Quantum-based Radio Frequency Source

Alírio Boaventura, Justus A. Brevik, Dylan Forrest Williams +5 more

We report on the calibration of quantum-based radio frequency waveforms generated by a Josephson arbitrary waveform synthesizer system. We measure these waveforms using a vector network analyzer and calibrate them at 4 K using a custom-designed cryogenic on-wafer multi-line thru-reflect-line calibration kit and a two-tier calibration procedure. The signals tested in this work can be used as reference signals to calibrate measurement instruments with potential benefits in terms of accuracy and flexibility compared to the conventional methods.

ARFTG Microwave Measurement Conference•Aug 4, 2020•5 citations

Traceable Validation of Calculable Quantum-Based RF Waveforms

Jeremy N. Thomas, Nathan E. Flowers-Jacobs, Anna E. Fox +2 more

We compare the calculated, quantum-based output of a radio-frequency Josephson arbitrary waveform synthesizer (RF-JAWS) with its measured output that is calibrated through the established NIST RF power traceability path, a necessary first step towards quantum-based RF metrology. An array of 1,500 Josephson junctions (JJs) is used to synthesize sinusoids from 50MHz to 3GHz, each with a nominal output power of −49.67dBm and a demonstrated quantum-locking range (QLR) exceeding 1mA. We perform a two-tier calibration of two-port vector network analyzer (VNA) measurements of the RF-JAWS waveforms with uncertainty analysis: (1) the VNA wave parameters are referenced to a NIST-calibrated coaxial power sensor, and (2) a cryogenic probe station, together with on-chip superconducting calibration standards, establishes an on-chip reference plane at the JJ-array. The calibrated measurement of the forward- and backward-propagating power is compared with the expected, calculated outputs, and, after accounting for high-frequency roll-off, we observe agreement within the expanded (k=2) uncertainty limits for most frequencies.

Conference on Precision Electromagnetic Measurements•Sep 1, 2026•0 citations

Traceable In Situ Microwave Power Measurement at the Cryogenic Device Plane in a Dilution Refrigerator

Paolo Panetta, Andrea Celotto, Alessandro Alocco +7 more

Accurate knowledge of the microwave power delivered to a cryogenic device under test (DUT) is essential for the characterization and operation of superconducting quantum circuits. However, this information is difficult to obtain inside dilution refrigerators because of distributed attenuation, impedance mismatch, switch-path repeatability, and temperature-dependent microwave components. This paper presents an in situ measurement method for RF power at the cryogenic device plane. The method uses a custom variable temperature stage (VTS) as a cryogenic thermal-transfer element. The TVS is alternately heated by a four-wire DC heater and by microwave power dissipated in a 20 dB pass-through attenuator. By fitting the thermal transients and comparing the corresponding steady-state temperatures, the absorbed microwave power is inferred from a directly measured DC electrical power through an AC/DC substitution procedure. The finite reflection and transmission of the attenuator are then accounted for by cryogenic two-port scattering-parameter measurements based on a switch-assisted Short--Open--Load--Reciprocal calibration, so that the result is referred to the DUT reference plane. The system is demonstrated in a dilution refrigerator with powers between -43 and -58 dBm at the DUT input plane. The demonstrated relative standard uncertainty ranges from about 2% at -43.9 dBm to about 40% at -57.6 dBm. The proposed approach combines thermal RF power transfer, cryogenic S-parameter correction, and uncertainty evaluation in a measurement architecture compatible with quantum-device experiments, providing a practical route toward traceable microwave-power calibration at millikelvin stages.

physics.ins-detCross-listedarXiv:2607.12751•Jul 15, 2026•0 citations

Microwave Modeling and Characterization of Superconductive Circuits for Quantum Voltage Standard Applications at 4 K

Alírio Boaventura, Dylan Forrest Williams, Richard Chamberlin +6 more

In this article, we characterize the microwave behavior of superconductive circuits for quantum voltage standard applications at 4 K. For that, we develop a cryogenic multiline thru-reflect-line (TRL) calibration procedure to calibrate the microwave measurements at the 4 K on-wafer reference plane. We model superconductive circuits, including a Josephson array transmission line, compare simulated to TRL-calibrated measured results, and find excellent agreement up to 50 GHz.

IEEE Transactions on Applied Superconductivity•Jan 1, 2020•19 citations

Cryogenic single-port calibration for superconducting microwave resonator measurements

H. Wang, Suren Singh, Corey Rae McRae +8 more

Superconducting circuit testing and materials loss characterization requires robust and reliable methods for the extraction of internal and coupling quality factors of microwave resonators. A common method, imposed by limitations on the device design or experimental configuration, is the single-port reflection geometry, i.e. reflection-mode. However, impedance mismatches in cryogenic systems must be accounted for through calibration of the measurement chain while it is at low temperatures. In this paper, we demonstrate a data-based, single-port calibration using commercial microwave standards and a vector network analyzer with samples at millikelvin temperature in a dilution refrigerator, making this method useful for measurements of quantum phenomena. Finally, we cross reference our data-based, single-port calibration and reflection measurement with over-coupled 2D- and 3D-resonators against well established two-port techniques corroborating the validity of our method.

arXiv:2103.01491•Quantum Science and Technology•Jun 28, 2021•47 citations

Quantum-Based Modulated Microwave Waveforms

Akim A. Babenko, Nathan E. Flowers-Jacobs, Anna E. Fox +3 more

This article presents a superconducting voltage source that generates modulated microwave waveforms with quantum-based stability. The voltage source—an RF Josephson Arbitrary Waveform Synthesizer (RF-JAWS)—uses a superconducting IC with an array of 4500 series-connected Josephson junctions (JJs) that are embedded in a coplanar waveguide (CPW) transmission line. The JJs are driven with 100-ps wide current pulses that force each JJ to generate voltage pulses with a quantized integrated area. A pulse sequence is created using a delta-sigma ($\Delta $–$\Sigma $) algorithm to generate a 101-tone waveform with a 40-MHz instantaneous bandwidth around 1005 MHz with a flat power distribution of −53 dBm and a Schroeder phase distribution. The JJ’s quantum-based nonlinearity produces an amplitude stability with respect to various drive and bias parameters of ±0.005 dB and a detrended phase stability of ±0.05°. The stability of the source is verified without the need for calibrated measurements. Another$\Delta $–$\Sigma $pulse sequence generates a 10-MHz quadrature-phase shift-keying (QPSK) waveform on a 1005-MHz carrier that has the same stability and the mean error vector magnitude (EVM) of −48 dB. This work is a step toward creating a quantum-based reference source for power and cross-frequency phase calibrations, as well as a reference-modulated signal source for calibrating telecommunication links.

IEEE Transactions on Microwave Theory and Techniques•Aug 4, 2023•6 citations
We are developing a new instrument, the RF Josephson arbitrary waveform synthesizer (RF-JAWS), for communications metrology and quantum information applications. An important aspect of the RF-JAWS design is the accurate and traceable characterization of its superconducting devices. In this article, we present a procedure for characterizing microwave superconducting devices in a cryogenic RF probe station via a vector network analyzer (VNA) calibrated with a custom cryogenic calibration kit colocated with the superconducting device under test (DUT) in the cryogenic environment. By de-embedding lossy and dispersive RF interconnects linking the superconducting DUT to the measurement apparatus at room temperature, we characterize the DUT exactly at the cryogenic on-wafer reference plane. More importantly, we operate our VNA with an external modulated source and our procedure features metrology-grade multiline thru-reflect-line calibration and absolute power and phase corrections, as opposed to the more common relative scattering-parameter correction. In addition, we apply anX-parameter model to account for impedance mismatch in cryogenic Josephson microwave sources. Our techniques are also suitable for cryogenic characterization of microwave superconducting devices for solid-state quantum computers and could help to optimize the quantum-classical interfaces in these systems.
We report on the calibration of quantum-based radio frequency waveforms generated by a Josephson arbitrary waveform synthesizer system. We measure these waveforms using a vector network analyzer and calibrate them at 4 K using a custom-designed cryogenic on-wafer multi-line thru-reflect-line calibration kit and a two-tier calibration procedure. The signals tested in this work can be used as reference signals to calibrate measurement instruments with potential benefits in terms of accuracy and flexibility compared to the conventional methods.
We compare the calculated, quantum-based output of a radio-frequency Josephson arbitrary waveform synthesizer (RF-JAWS) with its measured output that is calibrated through the established NIST RF power traceability path, a necessary first step towards quantum-based RF metrology. An array of 1,500 Josephson junctions (JJs) is used to synthesize sinusoids from 50MHz to 3GHz, each with a nominal output power of −49.67dBm and a demonstrated quantum-locking range (QLR) exceeding 1mA. We perform a two-tier calibration of two-port vector network analyzer (VNA) measurements of the RF-JAWS waveforms with uncertainty analysis: (1) the VNA wave parameters are referenced to a NIST-calibrated coaxial power sensor, and (2) a cryogenic probe station, together with on-chip superconducting calibration standards, establishes an on-chip reference plane at the JJ-array. The calibrated measurement of the forward- and backward-propagating power is compared with the expected, calculated outputs, and, after accounting for high-frequency roll-off, we observe agreement within the expanded (k=2) uncertainty limits for most frequencies.
Accurate knowledge of the microwave power delivered to a cryogenic device under test (DUT) is essential for the characterization and operation of superconducting quantum circuits. However, this information is difficult to obtain inside dilution refrigerators because of distributed attenuation, impedance mismatch, switch-path repeatability, and temperature-dependent microwave components. This paper presents an in situ measurement method for RF power at the cryogenic device plane. The method uses a custom variable temperature stage (VTS) as a cryogenic thermal-transfer element. The TVS is alternately heated by a four-wire DC heater and by microwave power dissipated in a 20 dB pass-through attenuator. By fitting the thermal transients and comparing the corresponding steady-state temperatures, the absorbed microwave power is inferred from a directly measured DC electrical power through an AC/DC substitution procedure. The finite reflection and transmission of the attenuator are then accounted for by cryogenic two-port scattering-parameter measurements based on a switch-assisted Short--Open--Load--Reciprocal calibration, so that the result is referred to the DUT reference plane. The system is demonstrated in a dilution refrigerator with powers between -43 and -58 dBm at the DUT input plane. The demonstrated relative standard uncertainty ranges from about 2% at -43.9 dBm to about 40% at -57.6 dBm. The proposed approach combines thermal RF power transfer, cryogenic S-parameter correction, and uncertainty evaluation in a measurement architecture compatible with quantum-device experiments, providing a practical route toward traceable microwave-power calibration at millikelvin stages.
Superconducting circuit testing and materials loss characterization requires robust and reliable methods for the extraction of internal and coupling quality factors of microwave resonators. A common method, imposed by limitations on the device design or experimental configuration, is the single-port reflection geometry, i.e. reflection-mode. However, impedance mismatches in cryogenic systems must be accounted for through calibration of the measurement chain while it is at low temperatures. In this paper, we demonstrate a data-based, single-port calibration using commercial microwave standards and a vector network analyzer with samples at millikelvin temperature in a dilution refrigerator, making this method useful for measurements of quantum phenomena. Finally, we cross reference our data-based, single-port calibration and reflection measurement with over-coupled 2D- and 3D-resonators against well established two-port techniques corroborating the validity of our method.
This article presents a superconducting voltage source that generates modulated microwave waveforms with quantum-based stability. The voltage source—an RF Josephson Arbitrary Waveform Synthesizer (RF-JAWS)—uses a superconducting IC with an array of 4500 series-connected Josephson junctions (JJs) that are embedded in a coplanar waveguide (CPW) transmission line. The JJs are driven with 100-ps wide current pulses that force each JJ to generate voltage pulses with a quantized integrated area. A pulse sequence is created using a delta-sigma ($\Delta –––\Sigma )algorithmtogeneratea101−tonewaveformwitha40−MHzinstantaneousbandwidtharound1005MHzwithaflatpowerdistributionof−53dBmandaSchroederphasedistribution.TheJJ’squantum−basednonlinearityproducesanamplitudestabilitywithrespecttovariousdriveandbiasparametersof±0.005dBandadetrendedphasestabilityof±0.05°.Thestabilityofthesourceisverifiedwithouttheneedforcalibratedmeasurements.Another) algorithm to generate a 101-tone waveform with a 40-MHz instantaneous bandwidth around 1005 MHz with a flat power distribution of −53 dBm and a Schroeder phase distribution. The JJ’s quantum-based nonlinearity produces an amplitude stability with respect to various drive and bias parameters of ±0.005 dB and a detrended phase stability of ±0.05°. The stability of the source is verified without the need for calibrated measurements. Another)algorithmtogeneratea101−tonewaveformwitha40−MHzinstantaneousbandwidtharound1005MHzwithaflatpowerdistributionof−53dBmandaSchroederphasedistribution.TheJJ’squantum−basednonlinearityproducesanamplitudestabilitywithrespecttovariousdriveandbiasparametersof±0.005dBandadetrendedphasestabilityof±0.05°.Thestabilityofthesourceisverifiedwithouttheneedforcalibratedmeasurements.Another\Delta –––\Sigma $pulse sequence generates a 10-MHz quadrature-phase shift-keying (QPSK) waveform on a 1005-MHz carrier that has the same stability and the mean error vector magnitude (EVM) of −48 dB. This work is a step toward creating a quantum-based reference source for power and cross-frequency phase calibrations, as well as a reference-modulated signal source for calibrating telecommunication links.