arXiv:2607.12751

Traceable In Situ Microwave Power Measurement at the Cryogenic Device Plane in a Dilution Refrigerator

Paolo Panetta, Andrea Celotto, Alessandro Alocco, Bernardo Galvano, Luca Fasolo, Emanuele Palumbo, Luca Callegaro, Luca Oberto, Patrizia Livreri, Emanuele Enrico

physics.ins-detphysics.app-phquant-phSubmitted Jul 14, 2026• Announced Jul 15, 2026• 0 citations
arXivHTMLPDF

Abstract

Accurate knowledge of the microwave power delivered to a cryogenic device under test (DUT) is essential for the characterization and operation of superconducting quantum circuits. However, this information is difficult to obtain inside dilution refrigerators because of distributed attenuation, impedance mismatch, switch-path repeatability, and temperature-dependent microwave components. This paper presents an in situ measurement method for RF power at the cryogenic device plane. The method uses a custom variable temperature stage (VTS) as a cryogenic thermal-transfer element. The TVS is alternately heated by a four-wire DC heater and by microwave power dissipated in a 20 dB pass-through attenuator. By fitting the thermal transients and comparing the corresponding steady-state temperatures, the absorbed microwave power is inferred from a directly measured DC electrical power through an AC/DC substitution procedure. The finite reflection and transmission of the attenuator are then accounted for by cryogenic two-port scattering-parameter measurements based on a switch-assisted Short--Open--Load--Reciprocal calibration, so that the result is referred to the DUT reference plane. The system is demonstrated in a dilution refrigerator with powers between -43 and -58 dBm at the DUT input plane. The demonstrated relative standard uncertainty ranges from about 2% at -43.9 dBm to about 40% at -57.6 dBm. The proposed approach combines thermal RF power transfer, cryogenic S-parameter correction, and uncertainty evaluation in a measurement architecture compatible with quantum-device experiments, providing a practical route toward traceable microwave-power calibration at millikelvin stages.

Comments
7 pages, 3 figures, 4 tables

Related papers

Cryogenic Characterization of a Superconductor Quantum-Based Microwave Reference Source for Communications and Quantum Information

Alírio Boaventura, Justus A. Brevik, Dylan Forrest Williams +6 more

We are developing a new instrument, the RF Josephson arbitrary waveform synthesizer (RF-JAWS), for communications metrology and quantum information applications. An important aspect of the RF-JAWS design is the accurate and traceable characterization of its superconducting devices. In this article, we present a procedure for characterizing microwave superconducting devices in a cryogenic RF probe station via a vector network analyzer (VNA) calibrated with a custom cryogenic calibration kit colocated with the superconducting device under test (DUT) in the cryogenic environment. By de-embedding lossy and dispersive RF interconnects linking the superconducting DUT to the measurement apparatus at room temperature, we characterize the DUT exactly at the cryogenic on-wafer reference plane. More importantly, we operate our VNA with an external modulated source and our procedure features metrology-grade multiline thru-reflect-line calibration and absolute power and phase corrections, as opposed to the more common relative scattering-parameter correction. In addition, we apply anX-parameter model to account for impedance mismatch in cryogenic Josephson microwave sources. Our techniques are also suitable for cryogenic characterization of microwave superconducting devices for solid-state quantum computers and could help to optimize the quantum-classical interfaces in these systems.

IEEE Transactions on Applied Superconductivity•Oct 13, 2021•8 citations

Device-Agnostic Microwave Noise Metrology for Nonlinear Cryogenic Quantum Devices

Andrea Celotto, Alessandro Alocco, Bernardo Galvano +6 more

Microwave devices capable of near-quantum-limited signal processing are essential components in the toolbox of solid-state quantum technologies. The manipulation and readout of single-photon microwave signals through amplifiers, mixers, isolators, etc. must fulfill strict requirements in terms of signal integrity to ensure reliable operation. These active microwave quantum devices operate in complex cryo-electronic setups. This poses challenges to their characterization, since all relevant figures of merit must be expressed at the reference planes of their ports. Even though cryogenic S-parameter calibration is non-trivial, metrological approaches are converging toward rigorous methods. Furthermore, preserving signal integrity must be quantified via absolute noise levels at the ports of the Device Under Test (DUT), requiring an absolute power reference. In this work, we present an in situ noise metrology protocol based on substituting a controllable noise source for the DUT. We motivate this choice by showing that placing the noise source at the DUT input impacts the separability of the calibration from the DUT characteristics. Our proposed architecture combines Planck spectroscopy using a Variable Temperature Stage with Short-Open-Load-Reciprocal scattering-parameter calibration, so that noise and scattering quantities are referred to the same cryogenic reference planes. In this configuration, the readout-chain calibration is separated from the internal dynamics of the DUT. As a demanding use case, we apply the protocol to a Josephson Traveling Wave Parametric Amplifier and extract its gain and input-referred added noise under pump conditions activating multimode nonlinear behavior. This illustrates how our device-agnostic protocol supports portable noise characterization of nonlinear cryogenic microwave devices.

quant-pharXiv:2605.28808•May 28, 2026•0 citations

In situ calibration of microwave attenuation and gain using a cryogenic on-chip attenuator

Thomas Descamps, Linus Andersson, Vittorio Buccheri +3 more

Accurate in situ calibration of microwave attenuation and amplification-chain noise is essential for superconducting quantum circuits. We demonstrate a compact, self-calibrating cryogenic noise source based on an on-chip chromium attenuator that can be resistively heated with nanowatt-level power and directly integrated into a coaxial microwave line at the mixing-chamber stage. By comparing Johnson-Nyquist noise generated by Joule and microwave heating, measured through the amplification chain, the attenuation of the input line, and hence the gain of the chain, is determined without requiring knowledge of the attenuator temperature. The device exhibits millisecond-scale response times and negligible heating of the cryostat base plate. Using this approach, we determine the gain and added noise of a cryogenic amplification chain over the 4-8 GHz band. Our results provide a simple and accurate method to characterize near-quantum-limited parametric amplifiers used in superconducting-qubit readout.

quant-pharXiv:2602.16889•Feb 20, 2026•0 citations

Broadband calibrated scattering parameters characterization of a superconducting quantum interference device amplifier

Leonardo Ranzani, Lafe Spietz, José Aumentado

In this work, we characterize the 2-port scattering parameters of a superconducting quantum interference device amplifier at ∼20 mK over several gigahertz of bandwidth. The measurement reference plane is positioned on a 6.25 Ω microstrip line situated directly at the input and output of the device by means of a thru-reflect-line cryogenic calibration procedure. From the scattering parameters, we derive the device available power gain, isolation, and input impedance over the 2–8 GHz range. This measurement methodology provides a path towards designing wide-band matching circuits for low impedance superconducting amplifiers operating at dilution refrigerator temperatures.

Applied Physics Letters•Jul 8, 2013•14 citations

Cryogenic single-port calibration for superconducting microwave resonator measurements

H. Wang, Suren Singh, Corey Rae McRae +8 more

Abstract Superconducting circuit testing and materials loss characterization requires robust and reliable methods for the extraction of internal and coupling quality factors of microwave resonators. A common method, imposed by limitations on the device design or experimental configuration, is the single-port reflection geometry, i.e. reflection-mode. However, impedance mismatches in cryogenic systems must be accounted for through calibration of the measurement chain while it is at low temperatures. In this paper, we demonstrate a data-based, single-port calibration using commercial microwave standards and a vector network analyzer with samples at millikelvin temperature in a dilution refrigerator, making this method useful for measurements of quantum phenomena. Finally, we cross reference our data-based, single-port calibration and reflection measurement with over-coupled 2D- and 3D-resonators against well established two-port techniques corroborating the validity of our method.

arXiv:2103.01491•Quantum Science and Technology•Jun 1, 2021•34 citations

Characterizing Scattering Parameters of Superconducting Quantum Integrated Circuits at Milli-Kelvin Temperatures

Manoj Stanley, Sebastian E. de Graaf, T. Hönigl-Decrinis +2 more

Designing large-scale superconducting quantum circuits involves complex microwave engineering to minimize loss, spurious reflections, and signal crosstalk. Essential for engineering more complex circuits is precise knowledge of devices’ microwave performance, which can be characterized by measuring its calibrated scattering parameters (S-parameters) at mK temperatures. In this work, we introduce a full 2-port calibrated S-parameter measurement setup which can characterize superconducting quantum integrated circuits and other RF integrated circuits operating at mK temperatures. The design and architecture of the measurement system consisting of in-house developed microwave calibration unit (MCU) housing the newly designed cryogenic calibration standards and the device under test (DUT) is discussed in detail. The measurement setup is then used to demonstrate the first calibrated S-parameter measurements of an in-house developed superconducting qubit integrated circuit at mK temperature.

IEEE Access•Jan 1, 2022•18 citations
Accurate knowledge of the microwave power delivered to a cryogenic device under test (DUT) is essential for the characterization and operation of superconducting quantum circuits. However, this information is difficult to obtain inside dilution refrigerators because of distributed attenuation, impedance mismatch, switch-path repeatability, and temperature-dependent microwave components. This paper presents an in situ measurement method for RF power at the cryogenic device plane. The method uses a custom variable temperature stage (VTS) as a cryogenic thermal-transfer element. The TVS is alternately heated by a four-wire DC heater and by microwave power dissipated in a 20 dB pass-through attenuator. By fitting the thermal transients and comparing the corresponding steady-state temperatures, the absorbed microwave power is inferred from a directly measured DC electrical power through an AC/DC substitution procedure. The finite reflection and transmission of the attenuator are then accounted for by cryogenic two-port scattering-parameter measurements based on a switch-assisted Short--Open--Load--Reciprocal calibration, so that the result is referred to the DUT reference plane. The system is demonstrated in a dilution refrigerator with powers between -43 and -58 dBm at the DUT input plane. The demonstrated relative standard uncertainty ranges from about 2% at -43.9 dBm to about 40% at -57.6 dBm. The proposed approach combines thermal RF power transfer, cryogenic S-parameter correction, and uncertainty evaluation in a measurement architecture compatible with quantum-device experiments, providing a practical route toward traceable microwave-power calibration at millikelvin stages.
We are developing a new instrument, the RF Josephson arbitrary waveform synthesizer (RF-JAWS), for communications metrology and quantum information applications. An important aspect of the RF-JAWS design is the accurate and traceable characterization of its superconducting devices. In this article, we present a procedure for characterizing microwave superconducting devices in a cryogenic RF probe station via a vector network analyzer (VNA) calibrated with a custom cryogenic calibration kit colocated with the superconducting device under test (DUT) in the cryogenic environment. By de-embedding lossy and dispersive RF interconnects linking the superconducting DUT to the measurement apparatus at room temperature, we characterize the DUT exactly at the cryogenic on-wafer reference plane. More importantly, we operate our VNA with an external modulated source and our procedure features metrology-grade multiline thru-reflect-line calibration and absolute power and phase corrections, as opposed to the more common relative scattering-parameter correction. In addition, we apply anX-parameter model to account for impedance mismatch in cryogenic Josephson microwave sources. Our techniques are also suitable for cryogenic characterization of microwave superconducting devices for solid-state quantum computers and could help to optimize the quantum-classical interfaces in these systems.
Microwave devices capable of near-quantum-limited signal processing are essential components in the toolbox of solid-state quantum technologies. The manipulation and readout of single-photon microwave signals through amplifiers, mixers, isolators, etc. must fulfill strict requirements in terms of signal integrity to ensure reliable operation. These active microwave quantum devices operate in complex cryo-electronic setups. This poses challenges to their characterization, since all relevant figures of merit must be expressed at the reference planes of their ports. Even though cryogenic S-parameter calibration is non-trivial, metrological approaches are converging toward rigorous methods. Furthermore, preserving signal integrity must be quantified via absolute noise levels at the ports of the Device Under Test (DUT), requiring an absolute power reference. In this work, we present an in situ noise metrology protocol based on substituting a controllable noise source for the DUT. We motivate this choice by showing that placing the noise source at the DUT input impacts the separability of the calibration from the DUT characteristics. Our proposed architecture combines Planck spectroscopy using a Variable Temperature Stage with Short-Open-Load-Reciprocal scattering-parameter calibration, so that noise and scattering quantities are referred to the same cryogenic reference planes. In this configuration, the readout-chain calibration is separated from the internal dynamics of the DUT. As a demanding use case, we apply the protocol to a Josephson Traveling Wave Parametric Amplifier and extract its gain and input-referred added noise under pump conditions activating multimode nonlinear behavior. This illustrates how our device-agnostic protocol supports portable noise characterization of nonlinear cryogenic microwave devices.
Accurate in situ calibration of microwave attenuation and amplification-chain noise is essential for superconducting quantum circuits. We demonstrate a compact, self-calibrating cryogenic noise source based on an on-chip chromium attenuator that can be resistively heated with nanowatt-level power and directly integrated into a coaxial microwave line at the mixing-chamber stage. By comparing Johnson-Nyquist noise generated by Joule and microwave heating, measured through the amplification chain, the attenuation of the input line, and hence the gain of the chain, is determined without requiring knowledge of the attenuator temperature. The device exhibits millisecond-scale response times and negligible heating of the cryostat base plate. Using this approach, we determine the gain and added noise of a cryogenic amplification chain over the 4-8 GHz band. Our results provide a simple and accurate method to characterize near-quantum-limited parametric amplifiers used in superconducting-qubit readout.
In this work, we characterize the 2-port scattering parameters of a superconducting quantum interference device amplifier at ∼20 mK over several gigahertz of bandwidth. The measurement reference plane is positioned on a 6.25 Ω microstrip line situated directly at the input and output of the device by means of a thru-reflect-line cryogenic calibration procedure. From the scattering parameters, we derive the device available power gain, isolation, and input impedance over the 2–8 GHz range. This measurement methodology provides a path towards designing wide-band matching circuits for low impedance superconducting amplifiers operating at dilution refrigerator temperatures.
Abstract Superconducting circuit testing and materials loss characterization requires robust and reliable methods for the extraction of internal and coupling quality factors of microwave resonators. A common method, imposed by limitations on the device design or experimental configuration, is the single-port reflection geometry, i.e. reflection-mode. However, impedance mismatches in cryogenic systems must be accounted for through calibration of the measurement chain while it is at low temperatures. In this paper, we demonstrate a data-based, single-port calibration using commercial microwave standards and a vector network analyzer with samples at millikelvin temperature in a dilution refrigerator, making this method useful for measurements of quantum phenomena. Finally, we cross reference our data-based, single-port calibration and reflection measurement with over-coupled 2D- and 3D-resonators against well established two-port techniques corroborating the validity of our method.
Designing large-scale superconducting quantum circuits involves complex microwave engineering to minimize loss, spurious reflections, and signal crosstalk. Essential for engineering more complex circuits is precise knowledge of devices’ microwave performance, which can be characterized by measuring its calibrated scattering parameters (S-parameters) at mK temperatures. In this work, we introduce a full 2-port calibrated S-parameter measurement setup which can characterize superconducting quantum integrated circuits and other RF integrated circuits operating at mK temperatures. The design and architecture of the measurement system consisting of in-house developed microwave calibration unit (MCU) housing the newly designed cryogenic calibration standards and the device under test (DUT) is discussed in detail. The measurement setup is then used to demonstrate the first calibrated S-parameter measurements of an in-house developed superconducting qubit integrated circuit at mK temperature.