arXiv:1906.02258 · Metrologia

Calibration of free-space and fiber-coupled single-photon detectors *

Thomas Gerrits, Alan L. Migdall, Joshua C Bienfang, John Lehman, Sae Woo Nam, Jolene Splett, Igor Vayshenker, Jack Wang

Published Sep 18, 2019• 58 citations
arXivHTMLPDF

Abstract

Abstract We measure the detection efficiency of single-photon detectors at wavelengths near 851 nm and 1533.6 nm. We investigate the spatial uniformity of one free-space-coupled single-photon avalanche diode and present a comparison between fusion-spliced and connectorized fiber-coupled single-photon detectors. We find that our expanded relative uncertainty for a single measurement of the detection efficiency is as low as 0.70% for fiber-coupled measurements at 1533.6 nm and as high as 1.78% for our free-space characterization at 851.7 nm. The detection-efficiency determination includes corrections for afterpulsing, dark count, and count-rate effects of the single-photon detector with the detection efficiency interpolated to operation at a specified detected count rate.

DOI
10.1088/1681-7575/ab4533

Related papers

Calibration of free-space and fiber-coupled single-photon detectors

Thomas Gerrits, Alan L. Migdall, Joshua C. Bienfang +6 more

We present our measurements of the detection efficiency of free-space and fiber-coupled single-photon detectors at wavelengths near 851 nm and 1533.6 nm. We investigate the spatial uniformity of one free-space-coupled silicon single-photon avalanche diode (SPAD) and present a comparison between fusion-spliced and connectorized fiber-coupled single-photon detectors. We find that our expanded relative uncertainty for a single measurement of the detection efficiency is as low as 0.7 % for fiber-coupled measurements at 1533.6 nm and as high as 1.8 % for our free-space characterization at 851.8 nm.

OSA Quantum 2.0 Conference•Jan 1, 2020•5 citations

A study to develop a robust method for measuring the detection efficiency of free-running InGaAs/InP single-photon detectors

Marco López, Alice Meda, Geiland Porrovecchio +7 more

Abstract The challenges faced in a comparison of measuring the detection efficiency of free-running InGaAs/InP single-photon avalanche detectors (InGaAs/InP SPAD) were studied by four European National Metrology Institutes (NMIs) meeting at a single laboratory. The main purpose of this study is to develop a trustable measurement technique and to provide a snapshot of the methods used by the four NMIs for measuring such photon-counting detectors at telecom wavelengths in order to establish proper procedures for characterising such devices. The detection efficiency measurements were performed using different experimental setups and reference standards with independent traceability chains at the wavelength of 1550 nm. A dedicated model to correct the dead time and dark count effects on the SPAD’s free-running counting process was developed, allowing the correct value of the photon rate impinging on the detector to be recovered from simple ratemeter measurements. The detection efficiency was measured for mean photon number per pulse between 0.01 and 2.4, corresponding to photon rates between approximately 1100 photon/s and 193,000 photon/s, respectively. We found that the measured values reported by the participants are all consistent within the stated uncertainties, proving the consistency of the measurement approach developed.

EPJ Quantum Technology•Nov 25, 2020•13 citations

Radiometric calibration of single photon detectors by a single photon source based on NV-centers in diamond

Waldemar Schmunk, M. Rodenberger, Silke Peters +2 more

A widespread use of various relative calibration techniques is established in order to realize reliable and low uncertainty measurements of the detection efficiency, which is one key parameter characterizing single photon detectors. In the following paper we will present an approach to evaluate the relative detection efficiency of single photon avalanche photo diode (SPAD) detectors compared to a standard detector. This calibration technique is based upon the fiber-coupled relative efficiency calibration of analogue detectors, used in fiber-optic communication. For the first time, to our knowledge, an intrinsic single photon source based on the nitrogen-vacancy center in diamond was used for this purpose. Furthermore, the possible influence of different photon statistics, arising from different irradiation sources like thermal sources or lasers on the calibration results for the fiber exchange method has been theoretically studied.

Journal of Modern Optics•Aug 4, 2011•34 citations

Recent Nanowire Superconducting Single-Photon Detector Optimization for Practical Applications

Alexander A. Korneev, Y. Korneeva, N. N. Manova +7 more

In this paper, we present our approaches to the development of fiber-coupled superconducting single photon detectors with enhanced photon absorption. For such devices we have measured detection efficiency in wavelength range from 500 to 2000 nm. The best fiber coupled devices exhibit detection efficiency of 44.5% at 1310 nm wavelength and 35.5% at 1550 nm at 10 dark counts per second.

IEEE Transactions on Applied Superconductivity•Mar 6, 2013•14 citations

Pilot comparison on the measurement of detection efficiency of InGaAs/InP single-photon detectors (Conference Presentation)

Marco López

InGaAs/InP single-photon detectors are today the most frequently used detectors for fibre-based Quantum Key Distribution (QKD) [1,2]. The performance of the QKD-systems greatly depends on the optical properties of its detector, such as quantum efficiency, dead time, dark counts, gating rate, etc., which need to be metrologically characterized to fully grantee the QKD network security. Therefore, several European National Metrological Institutes (NMIs) are putting today great efforts in developing novel measurement methods and calibration facilities, which allow to perform the traceable characterisation of single-photon detectors by using reference standards [3, 4]. From the metrological, and specifically radiometric, point of view, the detection efficiency of the single-photon detector is the main parameter that needs to be traceable to the primary standard for optical power (i.e. the cryogenic radiometer), which is maintained by most of the NMIs. Recently, four European NMIs have carried out a pilot comparison on the detection efficiency of a free-running InGaAs/InP single-photon detector, which main purpose has been to provide a snapshot of the measurement capabilities of the four European NMIs in the field of photon counting detection. The comparison was carried out in the framework of the EMPIR project 14IND05 “Optical metrology for quantum-enhanced secure telecommunication (MIQC2)” at the telecom wavelength of 1550 nm by using different reference standards with independently traceability chains. The results of this comparison, including the different experimental setups, the measurement methods, the traceability chain and the uncertainty evaluation of each participant, will be presented in this conference. References: [1] Akihisa Tomita, et al., “High speed quantum key distribution system”, Optical Fiber Technology, 16, Issue 1, 55-62 (2010). [2] Damien Stucki, et al., “Photon counting for quantum key distribution with peltier cooled InGaAs/InP APDs”, Journal of Modern Optics, 48, Issue 13, 1967-1981 (2001). [3] M. López, et al, “Detection efficiency calibration of single-photon silicon avalanche photodiodes traceable using double attenuator technique, Journal of Modern Optics 62, S21 – S27, 2015. [4] G. Porrovecchio, et al., “Comparison at the sub-100 fW optical power level of calibrating a single-photon detector using a high-sensitive, low-noise silicon photodiode and the double attenuator technique”, Metrologia 53, 1115-1122 (2016).

SPIE Quantum Technologies•May 29, 2018•0 citations

Single-Photon Detection System for Quantum Optics Applications

Alexander A. Korneev, Yu. B. Vachtomin, Olga V. Minaeva +17 more

We describe the design and characterization of a fiber-coupled double-channel single-photon detection system based on superconducting single-photon detectors (SSPD), and its application for quantum optics experiments on semiconductor nanostructures. When operated at 2-K temperature, the system shows 10% quantum efficiency at 1.3-¿m wavelength with dark count rate below 10 counts per second and timing resolution <100 ps. The short recovery time and absence of afterpulsing leads to counting frequencies as high as 40 MHz. Moreover, the low dark count rate allows operation in continuous mode (without gating). These characteristics are very attractive-as compared to InGaAs avalanche photodiodes-for quantum optics experiments at telecommunication wavelengths. We demonstrate the use of the system in time-correlated fluorescence spectroscopy of quantum wells and in the measurement of the intensity correlation function of light emitted by semiconductor quantum dots at 1300 nm.

IEEE Journal of Selected Topics in Quantum Electronics•Jan 1, 2007•48 citations
Abstract We measure the detection efficiency of single-photon detectors at wavelengths near 851 nm and 1533.6 nm. We investigate the spatial uniformity of one free-space-coupled single-photon avalanche diode and present a comparison between fusion-spliced and connectorized fiber-coupled single-photon detectors. We find that our expanded relative uncertainty for a single measurement of the detection efficiency is as low as 0.70% for fiber-coupled measurements at 1533.6 nm and as high as 1.78% for our free-space characterization at 851.7 nm. The detection-efficiency determination includes corrections for afterpulsing, dark count, and count-rate effects of the single-photon detector with the detection efficiency interpolated to operation at a specified detected count rate.
We present our measurements of the detection efficiency of free-space and fiber-coupled single-photon detectors at wavelengths near 851 nm and 1533.6 nm. We investigate the spatial uniformity of one free-space-coupled silicon single-photon avalanche diode (SPAD) and present a comparison between fusion-spliced and connectorized fiber-coupled single-photon detectors. We find that our expanded relative uncertainty for a single measurement of the detection efficiency is as low as 0.7 % for fiber-coupled measurements at 1533.6 nm and as high as 1.8 % for our free-space characterization at 851.8 nm.
Abstract The challenges faced in a comparison of measuring the detection efficiency of free-running InGaAs/InP single-photon avalanche detectors (InGaAs/InP SPAD) were studied by four European National Metrology Institutes (NMIs) meeting at a single laboratory. The main purpose of this study is to develop a trustable measurement technique and to provide a snapshot of the methods used by the four NMIs for measuring such photon-counting detectors at telecom wavelengths in order to establish proper procedures for characterising such devices. The detection efficiency measurements were performed using different experimental setups and reference standards with independent traceability chains at the wavelength of 1550 nm. A dedicated model to correct the dead time and dark count effects on the SPAD’s free-running counting process was developed, allowing the correct value of the photon rate impinging on the detector to be recovered from simple ratemeter measurements. The detection efficiency was measured for mean photon number per pulse between 0.01 and 2.4, corresponding to photon rates between approximately 1100 photon/s and 193,000 photon/s, respectively. We found that the measured values reported by the participants are all consistent within the stated uncertainties, proving the consistency of the measurement approach developed.
A widespread use of various relative calibration techniques is established in order to realize reliable and low uncertainty measurements of the detection efficiency, which is one key parameter characterizing single photon detectors. In the following paper we will present an approach to evaluate the relative detection efficiency of single photon avalanche photo diode (SPAD) detectors compared to a standard detector. This calibration technique is based upon the fiber-coupled relative efficiency calibration of analogue detectors, used in fiber-optic communication. For the first time, to our knowledge, an intrinsic single photon source based on the nitrogen-vacancy center in diamond was used for this purpose. Furthermore, the possible influence of different photon statistics, arising from different irradiation sources like thermal sources or lasers on the calibration results for the fiber exchange method has been theoretically studied.
InGaAs/InP single-photon detectors are today the most frequently used detectors for fibre-based Quantum Key Distribution (QKD) [1,2]. The performance of the QKD-systems greatly depends on the optical properties of its detector, such as quantum efficiency, dead time, dark counts, gating rate, etc., which need to be metrologically characterized to fully grantee the QKD network security. Therefore, several European National Metrological Institutes (NMIs) are putting today great efforts in developing novel measurement methods and calibration facilities, which allow to perform the traceable characterisation of single-photon detectors by using reference standards [3, 4]. From the metrological, and specifically radiometric, point of view, the detection efficiency of the single-photon detector is the main parameter that needs to be traceable to the primary standard for optical power (i.e. the cryogenic radiometer), which is maintained by most of the NMIs. Recently, four European NMIs have carried out a pilot comparison on the detection efficiency of a free-running InGaAs/InP single-photon detector, which main purpose has been to provide a snapshot of the measurement capabilities of the four European NMIs in the field of photon counting detection. The comparison was carried out in the framework of the EMPIR project 14IND05 “Optical metrology for quantum-enhanced secure telecommunication (MIQC2)” at the telecom wavelength of 1550 nm by using different reference standards with independently traceability chains. The results of this comparison, including the different experimental setups, the measurement methods, the traceability chain and the uncertainty evaluation of each participant, will be presented in this conference. References: [1] Akihisa Tomita, et al., “High speed quantum key distribution system”, Optical Fiber Technology, 16, Issue 1, 55-62 (2010). [2] Damien Stucki, et al., “Photon counting for quantum key distribution with peltier cooled InGaAs/InP APDs”, Journal of Modern Optics, 48, Issue 13, 1967-1981 (2001). [3] M. López, et al, “Detection efficiency calibration of single-photon silicon avalanche photodiodes traceable using double attenuator technique, Journal of Modern Optics 62, S21 – S27, 2015. [4] G. Porrovecchio, et al., “Comparison at the sub-100 fW optical power level of calibrating a single-photon detector using a high-sensitive, low-noise silicon photodiode and the double attenuator technique”, Metrologia 53, 1115-1122 (2016).
We describe the design and characterization of a fiber-coupled double-channel single-photon detection system based on superconducting single-photon detectors (SSPD), and its application for quantum optics experiments on semiconductor nanostructures. When operated at 2-K temperature, the system shows 10% quantum efficiency at 1.3-¿m wavelength with dark count rate below 10 counts per second and timing resolution <100 ps. The short recovery time and absence of afterpulsing leads to counting frequencies as high as 40 MHz. Moreover, the low dark count rate allows operation in continuous mode (without gating). These characteristics are very attractive-as compared to InGaAs avalanche photodiodes-for quantum optics experiments at telecommunication wavelengths. We demonstrate the use of the system in time-correlated fluorescence spectroscopy of quantum wells and in the measurement of the intensity correlation function of light emitted by semiconductor quantum dots at 1300 nm.