Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

OSA Quantum 2.0 Conference

Calibration of free-space and fiber-coupled single-photon detectors

Thomas Gerrits, Alan L. Migdall, Joshua C. Bienfang, John H. Lehman, Sae Woo Nam, Oliver Slattery, Jolene D. Splett, Igor Vayshenker, Jack Wang

Published Jan 1, 2020• 5 citations
Publisher

Abstract

We present our measurements of the detection efficiency of free-space and fiber-coupled single-photon detectors at wavelengths near 851 nm and 1533.6 nm. We investigate the spatial uniformity of one free-space-coupled silicon single-photon avalanche diode (SPAD) and present a comparison between fusion-spliced and connectorized fiber-coupled single-photon detectors. We find that our expanded relative uncertainty for a single measurement of the detection efficiency is as low as 0.7 % for fiber-coupled measurements at 1533.6 nm and as high as 1.8 % for our free-space characterization at 851.8 nm.

DOI
10.1364/quantum.2020.qw6b.7

Related papers

Calibration of free-space and fiber-coupled single-photon detectors *

Thomas Gerrits, Alan L. Migdall, Joshua C Bienfang +5 more

Abstract We measure the detection efficiency of single-photon detectors at wavelengths near 851 nm and 1533.6 nm. We investigate the spatial uniformity of one free-space-coupled single-photon avalanche diode and present a comparison between fusion-spliced and connectorized fiber-coupled single-photon detectors. We find that our expanded relative uncertainty for a single measurement of the detection efficiency is as low as 0.70% for fiber-coupled measurements at 1533.6 nm and as high as 1.78% for our free-space characterization at 851.7 nm. The detection-efficiency determination includes corrections for afterpulsing, dark count, and count-rate effects of the single-photon detector with the detection efficiency interpolated to operation at a specified detected count rate.

arXiv:1906.02258•Metrologia•Sep 18, 2019•58 citations

Radiometric calibration of single photon detectors by a single photon source based on NV-centers in diamond

Waldemar Schmunk, M. Rodenberger, Silke Peters +2 more

A widespread use of various relative calibration techniques is established in order to realize reliable and low uncertainty measurements of the detection efficiency, which is one key parameter characterizing single photon detectors. In the following paper we will present an approach to evaluate the relative detection efficiency of single photon avalanche photo diode (SPAD) detectors compared to a standard detector. This calibration technique is based upon the fiber-coupled relative efficiency calibration of analogue detectors, used in fiber-optic communication. For the first time, to our knowledge, an intrinsic single photon source based on the nitrogen-vacancy center in diamond was used for this purpose. Furthermore, the possible influence of different photon statistics, arising from different irradiation sources like thermal sources or lasers on the calibration results for the fiber exchange method has been theoretically studied.

Journal of Modern Optics•Aug 4, 2011•34 citations

A study to develop a robust method for measuring the detection efficiency of free-running InGaAs/InP single-photon detectors

Marco López, Alice Meda, Geiland Porrovecchio +7 more

Abstract The challenges faced in a comparison of measuring the detection efficiency of free-running InGaAs/InP single-photon avalanche detectors (InGaAs/InP SPAD) were studied by four European National Metrology Institutes (NMIs) meeting at a single laboratory. The main purpose of this study is to develop a trustable measurement technique and to provide a snapshot of the methods used by the four NMIs for measuring such photon-counting detectors at telecom wavelengths in order to establish proper procedures for characterising such devices. The detection efficiency measurements were performed using different experimental setups and reference standards with independent traceability chains at the wavelength of 1550 nm. A dedicated model to correct the dead time and dark count effects on the SPAD’s free-running counting process was developed, allowing the correct value of the photon rate impinging on the detector to be recovered from simple ratemeter measurements. The detection efficiency was measured for mean photon number per pulse between 0.01 and 2.4, corresponding to photon rates between approximately 1100 photon/s and 193,000 photon/s, respectively. We found that the measured values reported by the participants are all consistent within the stated uncertainties, proving the consistency of the measurement approach developed.

EPJ Quantum Technology•Nov 25, 2020•13 citations

Detection efficiency characterization for free-space single-photon detectors

Alice Meda, Salvatore Virzì, G. Brida +4 more

We introduce an experimental setup for measuring the detection efficiency of free-space single-photon detectors with excellent reproducibility and minimized uncertainty . Our analysis extends to account for the wavelength-dependent effects caused by the transmissivity of the optical window in front of the detector’s active area. The proposed approach involves measuring the detector’s response at different wavelengths and comparing it with a calibrated reference detector, enabling precise quantification of efficiency variations due to the optical window. The results provide a detailed understanding of wavelength-dependent efficiency, which is essential for optimizing the performance of single-photon detectors in applications such as quantum communication and photonics research. This characterization technique represents a significant step forward in enhancing the accuracy and reliability of single-photon detection efficiency measurements.

•Jan 1, 2025•0 citations

Calibration on the detection efficiency of the Si-APD and InGaAs-APD single-photon detectors by correlated photon pairs

Xueshun Shi, Kun Zhao, Changming Liu +3 more

We demonstrated calibration on the detection efficiency of Si-avalanche photodiode (APD) and InGaAs-APD singlephoton detectors by correlated photon pairs at 780 nm and 1550 nm, respectively. The correlated photons were generated by spontaneous frequency down-conversion in a periodically poled potassium titanyl phosphate crystal (PPKTP) pumped by a pulsed fiber laser. The uncertainty of ~10-4 on detection efficiency was obtained for both single-photon detectors.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 27, 2017•2 citations

Detection and spectral measurement of single photons in communication bands using up-conversion technology

Long Ma, Oliver Slattery, Xiao Hong Tang

Quantum information systems are commonly operated in conventional communication bands (1310 and 1550 nm) over an optical fiber to take advantage of low transmission loss. However, the detection and spectral measurement of single photons in these communication bands are limited due to high noise and low sensitivity of single photon detectors in the wavelength ranges. To demonstrate high efficiency detection and high sensitivity spectral measurement, we have implemented a single photon detector and a spectrometer based on frequency up-conversion technology. This detector and spectrometer uses a 5-cm periodically poled lithium niobate (PPLN) waveguide and a tunable pump laser around 1550 nm, to convert signal photons around 1310 to 710 nm. The converted photons are then detected by a silicon-based avalanche photodiode (APD). The overall detection efficiency of the single photon detector is as high as 32%, which is three times higher than commercial InGaAs APDs. The sensitivity of the spectrometer is measured to be −126 dBm, which is at least three orders-of-magnitude better than any commercial optical spectrum analyzer in this wavelength range.

Laser Physics•Apr 2, 2010•11 citations
We present our measurements of the detection efficiency of free-space and fiber-coupled single-photon detectors at wavelengths near 851 nm and 1533.6 nm. We investigate the spatial uniformity of one free-space-coupled silicon single-photon avalanche diode (SPAD) and present a comparison between fusion-spliced and connectorized fiber-coupled single-photon detectors. We find that our expanded relative uncertainty for a single measurement of the detection efficiency is as low as 0.7 % for fiber-coupled measurements at 1533.6 nm and as high as 1.8 % for our free-space characterization at 851.8 nm.
Abstract We measure the detection efficiency of single-photon detectors at wavelengths near 851 nm and 1533.6 nm. We investigate the spatial uniformity of one free-space-coupled single-photon avalanche diode and present a comparison between fusion-spliced and connectorized fiber-coupled single-photon detectors. We find that our expanded relative uncertainty for a single measurement of the detection efficiency is as low as 0.70% for fiber-coupled measurements at 1533.6 nm and as high as 1.78% for our free-space characterization at 851.7 nm. The detection-efficiency determination includes corrections for afterpulsing, dark count, and count-rate effects of the single-photon detector with the detection efficiency interpolated to operation at a specified detected count rate.
A widespread use of various relative calibration techniques is established in order to realize reliable and low uncertainty measurements of the detection efficiency, which is one key parameter characterizing single photon detectors. In the following paper we will present an approach to evaluate the relative detection efficiency of single photon avalanche photo diode (SPAD) detectors compared to a standard detector. This calibration technique is based upon the fiber-coupled relative efficiency calibration of analogue detectors, used in fiber-optic communication. For the first time, to our knowledge, an intrinsic single photon source based on the nitrogen-vacancy center in diamond was used for this purpose. Furthermore, the possible influence of different photon statistics, arising from different irradiation sources like thermal sources or lasers on the calibration results for the fiber exchange method has been theoretically studied.
Abstract The challenges faced in a comparison of measuring the detection efficiency of free-running InGaAs/InP single-photon avalanche detectors (InGaAs/InP SPAD) were studied by four European National Metrology Institutes (NMIs) meeting at a single laboratory. The main purpose of this study is to develop a trustable measurement technique and to provide a snapshot of the methods used by the four NMIs for measuring such photon-counting detectors at telecom wavelengths in order to establish proper procedures for characterising such devices. The detection efficiency measurements were performed using different experimental setups and reference standards with independent traceability chains at the wavelength of 1550 nm. A dedicated model to correct the dead time and dark count effects on the SPAD’s free-running counting process was developed, allowing the correct value of the photon rate impinging on the detector to be recovered from simple ratemeter measurements. The detection efficiency was measured for mean photon number per pulse between 0.01 and 2.4, corresponding to photon rates between approximately 1100 photon/s and 193,000 photon/s, respectively. We found that the measured values reported by the participants are all consistent within the stated uncertainties, proving the consistency of the measurement approach developed.
We introduce an experimental setup for measuring the detection efficiency of free-space single-photon detectors with excellent reproducibility and minimized uncertainty . Our analysis extends to account for the wavelength-dependent effects caused by the transmissivity of the optical window in front of the detector’s active area. The proposed approach involves measuring the detector’s response at different wavelengths and comparing it with a calibrated reference detector, enabling precise quantification of efficiency variations due to the optical window. The results provide a detailed understanding of wavelength-dependent efficiency, which is essential for optimizing the performance of single-photon detectors in applications such as quantum communication and photonics research. This characterization technique represents a significant step forward in enhancing the accuracy and reliability of single-photon detection efficiency measurements.
Quantum information systems are commonly operated in conventional communication bands (1310 and 1550 nm) over an optical fiber to take advantage of low transmission loss. However, the detection and spectral measurement of single photons in these communication bands are limited due to high noise and low sensitivity of single photon detectors in the wavelength ranges. To demonstrate high efficiency detection and high sensitivity spectral measurement, we have implemented a single photon detector and a spectrometer based on frequency up-conversion technology. This detector and spectrometer uses a 5-cm periodically poled lithium niobate (PPLN) waveguide and a tunable pump laser around 1550 nm, to convert signal photons around 1310 to 710 nm. The converted photons are then detected by a silicon-based avalanche photodiode (APD). The overall detection efficiency of the single photon detector is as high as 32%, which is three times higher than commercial InGaAs APDs. The sensitivity of the spectrometer is measured to be −126 dBm, which is at least three orders-of-magnitude better than any commercial optical spectrum analyzer in this wavelength range.