Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1902.06447

Microwave magnetic field imaging based on Rabi resonance with an alkali-atom vapor cell

Xiaochi Liu, Songbai Kang, Zhenfei Song, Zhiyuan Jiang, Wanfeng Zhang, Jifeng Qu

Published Feb 18, 2019• 0 citations
arXivHTMLPDF

Abstract

In this work, we demonstrate a microwave magnetic field imaging technique based on Rabi resonance with a cesium atom vapor cell. Rabi resonance signals are generated when atoms interact with a phase-modulated microwave (MW) field and are detected by a photodiode and camera. A low noise, high quantum efficiency camera is used to capture a series of frames for different phase modulation frequencies. Rabi frequencies of each spatial point in the field can be measured by scanning the frames. Thus, the strength of the MW magnetic field distribution is obtained by combing the Rabi frequencies, measured with camera pixels in the range of the probe laser beam. The simple architecture of this imaging setup holds great potential for the construction of compact/miniature MW field sensors for material testing, field imaging of MW components, and biomedical imaging.

DOI
10.48550/arxiv.1902.06447

Related papers

Microwave magnetic field strength imaging based on Rabi resonance with alkali-atom vapor cell

Lang Chen, Minghao Yao, Yang Shi +6 more

The present Rabi resonance microwave sensing technique cannot fully describe the microwave magnetic field strength distribution due to the signal detection method. Here, we propose an alternative Rabi resonance-based microwave imaging technique using a digital micromirror device and an alkali atomic cell. The experimental results well describe the distribution of the microwave field quantitatively and agree with the absorption imaging results. This technique can also be used as a method to analyze and measure the relaxation rate in an atomic vapor cell and offers a SI-traceable imaging approach for the microwave magnetic field. Its simple architecture holds great potential for the development of compact/miniature microwave field sensors.

Applied Physics Letters•Jun 6, 2022•7 citations

Simple microwave field imaging technique using hot atomic vapor cells

Pascal Böhi, Philipp Treutlein

We demonstrate a simple technique for microwave field imaging using alkali atoms in a vapor cell. The microwave field to be measured drives Rabi oscillations on atomic hyperfine transitions, which are detected in a spatially resolved way using a laser beam and a camera. Our vapor cell geometry enables single-shot recording of two-dimensional microwave field images with 350 μm spatial resolution. Using microfabricated vapor cell arrays, a resolution of a few micrometers seems feasible. All vector components of the microwave magnetic field can be imaged. Our apparatus is simple and compact and does not require cryogenics or ultra-high vacuum.

arXiv:1207.4964•Applied Physics Letters•Oct 29, 2012•69 citations

Microwave magnetic field sensing based on Rabi resonance using Rb vapor cell with anti-relaxation coating

Ning Ru, Xiaochi Liu, Jifeng Qu

Using a detection technique of microwave (MW) magnetic field based on Rabi resonance, we have constructed a SI-traceable MW magnetic field sensor. Unlike the uncoated cylindrical Cs vapor cell filled with buffer gas presented in our previous work, here we developed an experimental setup based on an alkali vapor cell with anti-relaxation coating. Rabi resonance signal lineshape are successfully observed when alkali atoms interact with a phase-modulated MW field. Several experimental parameters, such as optical laser intensity and cell temperature, are detailly studied and characterized. The optimal amplitude of Rabi resonance lineshape were obtained, which is well-agreed with the theoretical model.

IEEE International Conference on Signal, Information and Data Processing (ICSIDP)•Dec 1, 2019•0 citations

Tunable microwave magnetic field detection based on Rabi resonance with a single cesium-rubidium hybrid vapor cell

Fuyu Sun, Zhiyuan Jiang, Jifeng Qu +4 more

We experimentally investigated continuously frequency-tunable microwave (MW) magnetic field detection based on Rabi resonance with a single cesium-rubidium hybrid vapor cell. The multispecies atomic systems, with their tunable abilities in transition frequencies, enabled this atomic sensing head to cover a broader detectable MW field scope compared to the use of a single alkali atom. Here, we demonstrated the simultaneous observation of atomic Rabi resonance signals with 85Rb, 87Rb, and 133Cs in the same vapor cell. Using an experimentally feasible static magnetic field (DC field) below 500 G, we realized a MW magnetic field strength detection with a bandwidth of 4.8 GHz around 8.1 GHz. The use of a hybrid cell system cell also enabled the detection of an identical MW field for different atomic species with the help of the DC field, allowing us to perform a perfect comparison for different applications that require the same electromagnetic environment. The results may be useful for the realization and application of many atomic detectors based on different physical principles.

arXiv:1807.08175•Applied Physics Letters•Oct 15, 2018•17 citations

Microwave magnetic field detection based on Cs vapor cell in free space

Xiaochi Liu, Zhiyuan Jiang, Jifeng Qu +3 more

In this study, we demonstrate the direct measurement of a microwave (MW) magnetic field through the detection of atomic Rabi resonances with Cs vapor cells in a free-space low-Q cavity. The line shape (amplitude and linewidth) of detected Rabi resonances is investigated versus several experimental parameters such as the laser intensity, cell buffer gas pressure, and cell length. The specially designed low-Q cavity creates a suitable MW environment allowing easy testing of different vapor cells with distinct properties. Obtained results are analyzed to optimize the performances of a MW magnetic field sensor based on the present atom-based detection technique.

Review of Scientific Instruments•Jun 1, 2018•29 citations

Measuring magnetic field inside a microwave cavity via Rabi resonances in Cs atoms

Fuyu Sun, Dong Hou, Qingsong Bai +3 more

We present a technique for measuring microwave (MW) field based on Rabi resonances induced by the interaction of atoms with a phase-modulated MW field. A theoretical model of field measurement is used to calculate Rabi frequency. Single-peak feature of the measurement model makes the technique a valuable tool for simple and fast field measurement. As an example, we use the technique to determine the MW field strength inside a Cs vapor cell in the X-band rectangular cavity for applied power in the range of -21 dBm to 20 dBm. The results show that this proposed technique is capable for detecting the field over a broad dynamical range.

arXiv:1611.09998•Nov 30, 2016•0 citations
In this work, we demonstrate a microwave magnetic field imaging technique based on Rabi resonance with a cesium atom vapor cell. Rabi resonance signals are generated when atoms interact with a phase-modulated microwave (MW) field and are detected by a photodiode and camera. A low noise, high quantum efficiency camera is used to capture a series of frames for different phase modulation frequencies. Rabi frequencies of each spatial point in the field can be measured by scanning the frames. Thus, the strength of the MW magnetic field distribution is obtained by combing the Rabi frequencies, measured with camera pixels in the range of the probe laser beam. The simple architecture of this imaging setup holds great potential for the construction of compact/miniature MW field sensors for material testing, field imaging of MW components, and biomedical imaging.
The present Rabi resonance microwave sensing technique cannot fully describe the microwave magnetic field strength distribution due to the signal detection method. Here, we propose an alternative Rabi resonance-based microwave imaging technique using a digital micromirror device and an alkali atomic cell. The experimental results well describe the distribution of the microwave field quantitatively and agree with the absorption imaging results. This technique can also be used as a method to analyze and measure the relaxation rate in an atomic vapor cell and offers a SI-traceable imaging approach for the microwave magnetic field. Its simple architecture holds great potential for the development of compact/miniature microwave field sensors.
We demonstrate a simple technique for microwave field imaging using alkali atoms in a vapor cell. The microwave field to be measured drives Rabi oscillations on atomic hyperfine transitions, which are detected in a spatially resolved way using a laser beam and a camera. Our vapor cell geometry enables single-shot recording of two-dimensional microwave field images with 350 μm spatial resolution. Using microfabricated vapor cell arrays, a resolution of a few micrometers seems feasible. All vector components of the microwave magnetic field can be imaged. Our apparatus is simple and compact and does not require cryogenics or ultra-high vacuum.
Using a detection technique of microwave (MW) magnetic field based on Rabi resonance, we have constructed a SI-traceable MW magnetic field sensor. Unlike the uncoated cylindrical Cs vapor cell filled with buffer gas presented in our previous work, here we developed an experimental setup based on an alkali vapor cell with anti-relaxation coating. Rabi resonance signal lineshape are successfully observed when alkali atoms interact with a phase-modulated MW field. Several experimental parameters, such as optical laser intensity and cell temperature, are detailly studied and characterized. The optimal amplitude of Rabi resonance lineshape were obtained, which is well-agreed with the theoretical model.
We experimentally investigated continuously frequency-tunable microwave (MW) magnetic field detection based on Rabi resonance with a single cesium-rubidium hybrid vapor cell. The multispecies atomic systems, with their tunable abilities in transition frequencies, enabled this atomic sensing head to cover a broader detectable MW field scope compared to the use of a single alkali atom. Here, we demonstrated the simultaneous observation of atomic Rabi resonance signals with 85Rb, 87Rb, and 133Cs in the same vapor cell. Using an experimentally feasible static magnetic field (DC field) below 500 G, we realized a MW magnetic field strength detection with a bandwidth of 4.8 GHz around 8.1 GHz. The use of a hybrid cell system cell also enabled the detection of an identical MW field for different atomic species with the help of the DC field, allowing us to perform a perfect comparison for different applications that require the same electromagnetic environment. The results may be useful for the realization and application of many atomic detectors based on different physical principles.
In this study, we demonstrate the direct measurement of a microwave (MW) magnetic field through the detection of atomic Rabi resonances with Cs vapor cells in a free-space low-Q cavity. The line shape (amplitude and linewidth) of detected Rabi resonances is investigated versus several experimental parameters such as the laser intensity, cell buffer gas pressure, and cell length. The specially designed low-Q cavity creates a suitable MW environment allowing easy testing of different vapor cells with distinct properties. Obtained results are analyzed to optimize the performances of a MW magnetic field sensor based on the present atom-based detection technique.
We present a technique for measuring microwave (MW) field based on Rabi resonances induced by the interaction of atoms with a phase-modulated MW field. A theoretical model of field measurement is used to calculate Rabi frequency. Single-peak feature of the measurement model makes the technique a valuable tool for simple and fast field measurement. As an example, we use the technique to determine the MW field strength inside a Cs vapor cell in the X-band rectangular cavity for applied power in the range of -21 dBm to 20 dBm. The results show that this proposed technique is capable for detecting the field over a broad dynamical range.