Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1807.08175 · Applied Physics Letters

Tunable microwave magnetic field detection based on Rabi resonance with a single cesium-rubidium hybrid vapor cell

Fuyu Sun, Zhiyuan Jiang, Jifeng Qu, Zhenfei Song, Jie Ma, Dong Hou, Xiaochi Liu

Published Oct 15, 2018• 17 citations
arXivHTMLPDF

Abstract

We experimentally investigated continuously frequency-tunable microwave (MW) magnetic field detection based on Rabi resonance with a single cesium-rubidium hybrid vapor cell. The multispecies atomic systems, with their tunable abilities in transition frequencies, enabled this atomic sensing head to cover a broader detectable MW field scope compared to the use of a single alkali atom. Here, we demonstrated the simultaneous observation of atomic Rabi resonance signals with 85Rb, 87Rb, and 133Cs in the same vapor cell. Using an experimentally feasible static magnetic field (DC field) below 500 G, we realized a MW magnetic field strength detection with a bandwidth of 4.8 GHz around 8.1 GHz. The use of a hybrid cell system cell also enabled the detection of an identical MW field for different atomic species with the help of the DC field, allowing us to perform a perfect comparison for different applications that require the same electromagnetic environment. The results may be useful for the realization and application of many atomic detectors based on different physical principles.

DOI
10.1063/1.5051025

Related papers

Microwave magnetic field imaging based on Rabi resonance with an alkali-atom vapor cell

Xiaochi Liu, Songbai Kang, Zhenfei Song +3 more

In this work, we demonstrate a microwave magnetic field imaging technique based on Rabi resonance with a cesium atom vapor cell. Rabi resonance signals are generated when atoms interact with a phase-modulated microwave (MW) field and are detected by a photodiode and camera. A low noise, high quantum efficiency camera is used to capture a series of frames for different phase modulation frequencies. Rabi frequencies of each spatial point in the field can be measured by scanning the frames. Thus, the strength of the MW magnetic field distribution is obtained by combing the Rabi frequencies, measured with camera pixels in the range of the probe laser beam. The simple architecture of this imaging setup holds great potential for the construction of compact/miniature MW field sensors for material testing, field imaging of MW components, and biomedical imaging.

arXiv:1902.06447•Feb 18, 2019•0 citations

High-dynamic-range microwave sensing using atomic Rabi resonances

Dong Hou, Chao Li, Fuyu Sun +6 more

Detection of the microwave (MW) field with high accuracy is very important in the physical science and engineering fields. Herein, an atomic Rabi resonance-based MW magnetic field sensor with a high-dynamic-range is reported, where α and β Rabi resonances are used to measure MW fields. In MW measurement experiments, the sensor successfully measured a magnetic field of about 10 nT at 9.2 GHz using the α Rabi resonance line on the cesium clock transition and continuously detected the MW magnetic field in the X-band over a high dynamic power range of >60 dB from the β Rabi resonance. Finally, the MW power frequency shift and power broadening are investigated to support more sensitive field measurements. The proposed MW detection method can be extended to cover a higher dynamic range and a wider frequency band by applying stronger excitations and exploring non-clock atomic transitions, respectively. In addition to MW magnetic field sensing, other potential application of the proposed method can be explored, including SI-traceable MW calibration and atomic communication.

Review of Scientific Instruments•Feb 1, 2023•4 citations

Microwave magnetic field detection based on Cs vapor cell in free space

Xiaochi Liu, Zhiyuan Jiang, Jifeng Qu +3 more

In this study, we demonstrate the direct measurement of a microwave (MW) magnetic field through the detection of atomic Rabi resonances with Cs vapor cells in a free-space low-Q cavity. The line shape (amplitude and linewidth) of detected Rabi resonances is investigated versus several experimental parameters such as the laser intensity, cell buffer gas pressure, and cell length. The specially designed low-Q cavity creates a suitable MW environment allowing easy testing of different vapor cells with distinct properties. Obtained results are analyzed to optimize the performances of a MW magnetic field sensor based on the present atom-based detection technique.

Review of Scientific Instruments•Jun 1, 2018•29 citations

Atom-based sensing technique of microwave electric and magnetic fields via a single rubidium vapor cell

Zhigang Feng, Xiaochi Liu, Yingyun Zhang +3 more

We present an atom-based approach for determining microwave electric and magnetic fields by using a single rubidium vapor cell in a microwave waveguide. For a 87Rb cascade three-level system employed in our experiment, a weak probe laser driving the lower transition, 5S1/2→5P3/2, is first used to measure the microwave magnetic field based on the atomic Rabi resonance. When a counter-propagating strong coupling laser is subsequently turned on to drive the Rydberg transition, 5P3/2→67D5/2, the same probe laser is then used as a Rydberg electromagnetically induced transparency (EIT) probe to measure the microwave electric field by investigating the resonant microwave dressed Autler-Townes splitting (ATS). By tuning the hyperfine transition frequency of the ground state using an experimentally feasible static magnetic field, we first achieved a measurement of the microwave electric and magnetic field strength at the same microwave frequency of 6.916 GHz. Based on the ideal relationship between the electric and magnetic field components, we obtained the equivalent microwave magnetic fields by fitting the inversion to the measured microwave electric fields, which demonstrated that the results were in agreement with the experimental measurement of the microwave magnetic fields in the same microwave power range. This study provides new experimental evidence for quantum-based microwave measurements of electric and magnetic fields by a single sensor in the same system.

Optics Express•Dec 23, 2022•7 citations

Microwave magnetic field sensing based on Rabi resonance using Rb vapor cell with anti-relaxation coating

Ning Ru, Xiaochi Liu, Jifeng Qu

Using a detection technique of microwave (MW) magnetic field based on Rabi resonance, we have constructed a SI-traceable MW magnetic field sensor. Unlike the uncoated cylindrical Cs vapor cell filled with buffer gas presented in our previous work, here we developed an experimental setup based on an alkali vapor cell with anti-relaxation coating. Rabi resonance signal lineshape are successfully observed when alkali atoms interact with a phase-modulated MW field. Several experimental parameters, such as optical laser intensity and cell temperature, are detailly studied and characterized. The optimal amplitude of Rabi resonance lineshape were obtained, which is well-agreed with the theoretical model.

IEEE International Conference on Signal, Information and Data Processing (ICSIDP)•Dec 1, 2019•0 citations

Atom-Based Microwave Sensing over 60 dB Dynamic Range

Dong Hou, Guangkun Guo, Ke Liu +4 more

Detection of microwave (MW) field with high accuracy is an important problem in the physical science and engineering area. In this work, we reported an atomic Rabi resonance-based MW magnetic field sensor and demonstrated its capability to continuously detect X-band MW magnetic field over a high dynamic power range of > 60 dB. The MW power frequency shift was carefully evaluated and canceled in order to support more sensitive filed measurement. A weak 9.2 GHz MW magnetic field lower than 10 nT was successful extracted from Rabi resonance line on the cesium clock transition. MW field and power detection capabilities of the presented method can be extended to cover a higher dynamic range and a wider frequency band by applying stronger excitation and exploring non-clock atomic transition. Our work enables potential applications including SI-traceable MW calibration and atomic communication.

IEEE International Conference on Communication Technology (ICCT)•Nov 11, 2022•0 citations
We experimentally investigated continuously frequency-tunable microwave (MW) magnetic field detection based on Rabi resonance with a single cesium-rubidium hybrid vapor cell. The multispecies atomic systems, with their tunable abilities in transition frequencies, enabled this atomic sensing head to cover a broader detectable MW field scope compared to the use of a single alkali atom. Here, we demonstrated the simultaneous observation of atomic Rabi resonance signals with 85Rb, 87Rb, and 133Cs in the same vapor cell. Using an experimentally feasible static magnetic field (DC field) below 500 G, we realized a MW magnetic field strength detection with a bandwidth of 4.8 GHz around 8.1 GHz. The use of a hybrid cell system cell also enabled the detection of an identical MW field for different atomic species with the help of the DC field, allowing us to perform a perfect comparison for different applications that require the same electromagnetic environment. The results may be useful for the realization and application of many atomic detectors based on different physical principles.
In this work, we demonstrate a microwave magnetic field imaging technique based on Rabi resonance with a cesium atom vapor cell. Rabi resonance signals are generated when atoms interact with a phase-modulated microwave (MW) field and are detected by a photodiode and camera. A low noise, high quantum efficiency camera is used to capture a series of frames for different phase modulation frequencies. Rabi frequencies of each spatial point in the field can be measured by scanning the frames. Thus, the strength of the MW magnetic field distribution is obtained by combing the Rabi frequencies, measured with camera pixels in the range of the probe laser beam. The simple architecture of this imaging setup holds great potential for the construction of compact/miniature MW field sensors for material testing, field imaging of MW components, and biomedical imaging.
Detection of the microwave (MW) field with high accuracy is very important in the physical science and engineering fields. Herein, an atomic Rabi resonance-based MW magnetic field sensor with a high-dynamic-range is reported, where α and β Rabi resonances are used to measure MW fields. In MW measurement experiments, the sensor successfully measured a magnetic field of about 10 nT at 9.2 GHz using the α Rabi resonance line on the cesium clock transition and continuously detected the MW magnetic field in the X-band over a high dynamic power range of >60 dB from the β Rabi resonance. Finally, the MW power frequency shift and power broadening are investigated to support more sensitive field measurements. The proposed MW detection method can be extended to cover a higher dynamic range and a wider frequency band by applying stronger excitations and exploring non-clock atomic transitions, respectively. In addition to MW magnetic field sensing, other potential application of the proposed method can be explored, including SI-traceable MW calibration and atomic communication.
In this study, we demonstrate the direct measurement of a microwave (MW) magnetic field through the detection of atomic Rabi resonances with Cs vapor cells in a free-space low-Q cavity. The line shape (amplitude and linewidth) of detected Rabi resonances is investigated versus several experimental parameters such as the laser intensity, cell buffer gas pressure, and cell length. The specially designed low-Q cavity creates a suitable MW environment allowing easy testing of different vapor cells with distinct properties. Obtained results are analyzed to optimize the performances of a MW magnetic field sensor based on the present atom-based detection technique.
We present an atom-based approach for determining microwave electric and magnetic fields by using a single rubidium vapor cell in a microwave waveguide. For a 87Rb cascade three-level system employed in our experiment, a weak probe laser driving the lower transition, 5S1/2→5P3/2, is first used to measure the microwave magnetic field based on the atomic Rabi resonance. When a counter-propagating strong coupling laser is subsequently turned on to drive the Rydberg transition, 5P3/2→67D5/2, the same probe laser is then used as a Rydberg electromagnetically induced transparency (EIT) probe to measure the microwave electric field by investigating the resonant microwave dressed Autler-Townes splitting (ATS). By tuning the hyperfine transition frequency of the ground state using an experimentally feasible static magnetic field, we first achieved a measurement of the microwave electric and magnetic field strength at the same microwave frequency of 6.916 GHz. Based on the ideal relationship between the electric and magnetic field components, we obtained the equivalent microwave magnetic fields by fitting the inversion to the measured microwave electric fields, which demonstrated that the results were in agreement with the experimental measurement of the microwave magnetic fields in the same microwave power range. This study provides new experimental evidence for quantum-based microwave measurements of electric and magnetic fields by a single sensor in the same system.
Using a detection technique of microwave (MW) magnetic field based on Rabi resonance, we have constructed a SI-traceable MW magnetic field sensor. Unlike the uncoated cylindrical Cs vapor cell filled with buffer gas presented in our previous work, here we developed an experimental setup based on an alkali vapor cell with anti-relaxation coating. Rabi resonance signal lineshape are successfully observed when alkali atoms interact with a phase-modulated MW field. Several experimental parameters, such as optical laser intensity and cell temperature, are detailly studied and characterized. The optimal amplitude of Rabi resonance lineshape were obtained, which is well-agreed with the theoretical model.
Detection of microwave (MW) field with high accuracy is an important problem in the physical science and engineering area. In this work, we reported an atomic Rabi resonance-based MW magnetic field sensor and demonstrated its capability to continuously detect X-band MW magnetic field over a high dynamic power range of > 60 dB. The MW power frequency shift was carefully evaluated and canceled in order to support more sensitive filed measurement. A weak 9.2 GHz MW magnetic field lower than 10 nT was successful extracted from Rabi resonance line on the cesium clock transition. MW field and power detection capabilities of the presented method can be extended to cover a higher dynamic range and a wider frequency band by applying stronger excitation and exploring non-clock atomic transition. Our work enables potential applications including SI-traceable MW calibration and atomic communication.