We present an atom-based approach for determining microwave electric and magnetic fields by using a single rubidium vapor cell in a microwave waveguide. For a 87Rb cascade three-level system employed in our experiment, a weak probe laser driving the lower transition, 5S1/2→5P3/2, is first used to measure the microwave magnetic field based on the atomic Rabi resonance. When a counter-propagating strong coupling laser is subsequently turned on to drive the Rydberg transition, 5P3/2→67D5/2, the same probe laser is then used as a Rydberg electromagnetically induced transparency (EIT) probe to measure the microwave electric field by investigating the resonant microwave dressed Autler-Townes splitting (ATS). By tuning the hyperfine transition frequency of the ground state using an experimentally feasible static magnetic field, we first achieved a measurement of the microwave electric and magnetic field strength at the same microwave frequency of 6.916 GHz. Based on the ideal relationship between the electric and magnetic field components, we obtained the equivalent microwave magnetic fields by fitting the inversion to the measured microwave electric fields, which demonstrated that the results were in agreement with the experimental measurement of the microwave magnetic fields in the same microwave power range. This study provides new experimental evidence for quantum-based microwave measurements of electric and magnetic fields by a single sensor in the same system.
We present an atom-based approach for determining microwave electric and magnetic fields by using a single rubidium vapor cell in a microwave waveguide. For a 87Rb cascade three-level system employed in our experiment, a weak probe laser driving the lower transition, 5S1/2→5P3/2, is first used to measure the microwave magnetic field based on the atomic Rabi resonance. When a counter-propagating strong coupling laser is subsequently turned on to drive the Rydberg transition, 5P3/2→67D5/2, the same probe laser is then used as a Rydberg electromagnetically induced transparency (EIT) probe to measure the microwave electric field by investigating the resonant microwave dressed Autler-Townes splitting (ATS). By tuning the hyperfine transition frequency of the ground state using an experimentally feasible static magnetic field, we first achieved a measurement of the microwave electric and magnetic field strength at the same microwave frequency of 6.916 GHz. Based on the ideal relationship between the electric and magnetic field components, we obtained the equivalent microwave magnetic fields by fitting the inversion to the measured microwave electric fields, which demonstrated that the results were in agreement with the experimental measurement of the microwave magnetic fields in the same microwave power range. This study provides new experimental evidence for quantum-based microwave measurements of electric and magnetic fields by a single sensor in the same system.
We demonstrate a multi-parameter sensing scheme for free space microwave electric and magnetic fields in single vapor cell based on the atom-based microwave detection techniques. A weak probe laser though a rubidium vapor cell first acts as magnetic probe to measure the microwave magnetic field via atomic Rabi resonance of the ground state hyperfine transition. When another strong coupling laser is subsequently counter-propagated and overlapped with the probe laser in the same atomic vapor cell, the probe laser is then used as electric probe to measure microwave electric field by off-resonant microwave dressed Rydberg Autler-Townes splitting. We achieve measurement of microwave electric and magnetic fields without any complicated tuning methods at the clock frequency of 6.835 GHz. Based on the inherent relationship between microwave electric and magnetic fields, and their good linear response characteristics in respective suitable power ranges, the equivalent microwave magnetic fields are derived from linear fitting of the measured electric fields, which are in agreement with the calibrated experimental results within the same power range. This work provides an effective approach for extending the power dynamic range of atom-based microwave quantum sensors.
Objective As the reform of the International System of Units (SI) progresses, many quantum metrology standards based on the superior characteristics of the atomic system have been successfully developed to replace physical standards, such as atomic clocks, atomic magnetometers, and atomic gravimeters. Recently, a new method of microwave electric field measurement with a wide frequency band and high sensitivity has been developed based on the quantum coherent spectroscopy of Rydberg atoms. Compared with conventional techniques, the Rydberg-atom-based microwave electric field measurement technique can transform the microwave field strength measurement into a higher-accuracy Rabi frequency measurement through atomic constants and directly link the microwave electric field strength to the SI. However, the discrete distribution of Rydberg energy levels leads to the limitations of discrete frequencies and narrow bandwidths in microwave electric field measurement. Although various methods for continuously tuning the frequency of the microwave field have been developed, such as resonant microwave tuning, far-detuned microwave AC Stark tuning, and DC Stark tuning, these methods often involve complex experimental setups and rely on discrete energy levels. Therefore, we use an off-resonant strong microwave field to measure the continuous tuning frequency range of the measured microwave electric fields through the AC Stark shift characteristics of Rydberg energy levels. Methods We conduct continuously tunable frequency measurements of the microwave electric field based on the near-off-resonant AC Stark effect in a rubidium atomic vapor cell. A ladder-type electromagnetically induced transparency (EIT) three-level configuration is formed by a ground state, 5S1/2, an excited state, 5P3/2 (F'=3), and a Rydberg state, 73S1/2. The probe laser and the coupling laser with the same linear polarization are overlapped and counter-propagated through the vapor cell. The weak probe laser with a wavelength of 780 nm is locked to the transition of 5S1/2(F=2)→5P3/2(F'=3). The strong coupling laser with a wavelength of about 480 nm is frequency scanned across the transition of 5P3/2(F'=3)→73S1/2. The near-off-resonant strong microwave tuning field and the measured microwave electric field are simultaneously applied to the atomic vapor cell through a single microwave horn antenna. When a weak resonant microwave electric field is applied, which is read out by an all-optical Rydberg electromagnetically induced transparency and exhibits Autler?Townes (AT) splitting spectrum as the measured field, the strong near-off-resonant microwave as tuning fields is then used to tune the Rydberg level by the AC Stark effect. By varying the frequency and power of the tuning field, we measure the resonance frequency of the AT splitting spectrum for 73S1/2 to adjacent nPj Rydberg states under different AC Stark shifts and obtain the continuous tuning frequency range of the measured microwave electric field. Results and Discussions We measure the coupling resonance frequency ranges from 73S1/2 to 72P1/2, 72P3/2, 73P1/2, and 73P3/2 Rydberg states by the AC Stark shift characteristics induced by the near-off-resonant strong microwave field. We investigate in detail the influence of the frequency and power of the tuning field on the resonance frequency of the measured microwave field. Under the influence of the tuning field, the resonance frequency of the measured microwave electric field changes with the frequency shift of Rydberg energy levels, with the corresponding EIT-AT splitting peak resonance frequency shift (Fig. 2). The maximum unidirectional resonance frequency tuning range of the measured microwave field is about 151 MHz. Considering the bidirectional frequency shift characteristics, the maximum continuous tunable range of the resonance frequency reaches over 200 MHz. The maximum continuous frequency tuning range reaches 400 MHz by combining the bidirectional tuning characteristics and different coupling state combinations (Fig. 3). Additionally, we investigate the variation of Autler?Townes splitting frequency intervals with microwave power under different resonance conditions. For the same resonance frequency shift, small detuning and low-power tuning fields have a smaller effect on the strength measurement of the test field compared with large detuning and high-power tuning fields and have a larger linear dynamic range (Fig. 4). Conclusions We introduce a novel method for continuous tunable microwave electric field measurement based on the near-off-resonant AC Stark effect in a Rydberg atomic vapor cell. We measure the continuous resonance frequency tuning range of microwave coupling between rubidium Rydberg atom 73S1/2 and adjacent nPj states. The maximum unidirectional tunable range for measurement is 151 MHz, and the maximum continuous frequency tuning range reaches 400 MHz by combining the bidirectional tuning characteristics and different coupling state combinations. Different from the resonant tuning method that depends on extra Rydberg levels, this method based on the AC Stark shift can achieve continuously tunable frequency measurement with a single Rydberg state and single microwave horn antenna. This approach not only overcomes the limitations of discrete frequency and narrow band of the existing Rydberg atomic microwave electric field measurement but also simplifies the system structure and enhances the practicability of the system. Our study lays the foundation for quantum metrology and the traceable measurement of microwave electric fields based on Rydberg atoms.
We provide the simultaneous traceable measurements of microwave electric fields at two different frequencies by the electromagnetically induced transparency (EIT) and Autler–Townes (AT) splitting. A static magnetic field working together with a linearly polarized probe and coupling light prepares Rydberg atoms in Zeeman sublevels with maximal |mJ| in an atomic vapor cell. Using the EIT-AT splitting of these two maximal |mJ| states, the microwave electric fields at two different frequencies are simultaneously measured, in which their frequency difference can be adjustable within the linear range of magnetic field-induced level shifts. The proposed method provides a promising prospect for calibrating multiple microwave frequencies simultaneously in the future.
Significant progress has been made in atom-based measurements of length, time, gravity and electromagnetic fields in recently years. Rydberg atom-based microwave electric field measurement, using electromagnetically induced transparency (EIT) in room temperature alkali-metal vapors, has been extensively investigated and aroused the broad interest. This approach may establish a new standard for the measurements of microwave (MW) and radio frequency (RF) electric fields.In this review, we describe the work on a new method of measuring electric fields based on quantum interference by using either cesium or rubidium atoms contained in a dielectric vapor cell. Rydberg atoms with principal quantum number n >>1 have large direct current (DC) polarizabilities and microwave transition dipole moments, thereby making them extremely sensitive to external electric fields. Using the Rydberg three-level EIT to detect the level splitting and shift that is induced by the external field, we can realize a rapid and robust self-calibration method of measuring the electric field in a frequency range from 0.01 GHz to 1000 GHz. For the MW electric field (frequency range > 1 GHz), the MW field causes the Rydberg states to split, known as an Autler-Townes splitting (A-T) effect when the applied microwave can resonate with adjacent Rydberg states. The MW coupled A-T splitting is proportional to the applied electric field strength, from which the field strength is measured. Using the EIT window, a high sensitivity of 3 μV·cm-1·Hz-1/2 and small electric field of 1 μV/cm are expected to be achieved with a modest setup, and the limitations of the sensitivity are also addressed in the review. For the RF field at frequency mj EIT lines, and avoided crossings formed with the fine-structure levels of equal mj and different J's, which is used to calibrate and measure the RF field amplitude. On the other hand, the dependence of the EIT-line strength on the RF field polarization provides a fast and robust polarization measurement of RF fields based on matching experimental data with a theoretical simulation. The measurements of minimum strengths and sensitivity of RF fields based on Rydberg atoms are one order magnitude below the values obtained by traditional antenna methods. The atom-based field measurement paves the way for determining fields through calibration-free, invariable atomic properties and miniaturization. We also propose its various potential applications in the future.
Atoms form the basis of precise measurement for many quantities (time, acceleration, rotation, magnetic field, etc.). Measurements of microwave frequency electric fields by traditional methods (i.e. engineered antennas) have limited sensitivity and can be difficult to calibrate properly. Highly-excited (Rydberg) neutral atoms have very large electric-dipole moments and many dipole allowed transitions in the range of 1 - 500 GHz. It is possible to sensitively probe the electric field in this range using the combination of two quantum interference phenomena: electromagnetically induced transparency and the Autler-Townes effect. This technique allows for very sensitive field amplitude, polarization, and sub-wavelength imaging measurements. These quantities can be extracted by measuring properties of a probe laser beam as it passes through a warm rubidium vapor cell. Thus far, Rydberg microwave electrometry has relied upon the absorption of the probe laser. We report on our use of polarization rotation, which corresponds to the real part of the susceptibility, for measuring the properties of microwave frequency electric fields. Our simulations show that when a magnetic field is present and directed along the optical propagation direction a polarization rotation signal exists and can be used for microwave electrometry. One central advantage in using the polarization rotation signal rather than the absorption signal is that common mode laser noise is naturally eliminated leading to a potentially dramatic increase in signal-to-noise ratio.
We theoretically and experimentally investigate the Rydberg electromagnetically induced transparency (EIT) and Autler-Townes (AT) splitting of 87 Rb vapor under the combined influence of a magnetic field and a microwave field. In the presence of static magnetic field, the effect of the microwave field leads to the dressing and splitting of each m F state, resulting in multiple spectral peaks in the EIT-AT spectrum. A simplified analytical formula was developed to explain the EIT-AT spectrum in a static magnetic field, and the theoretical calculations agree qualitatively with experimental results. The Rydberg atom microwave electric field sensor performance was enhanced by making use of the splitting interval between the two maximum absolute m F states separated by the static magnetic field, which was attributed to the stronger Clebsch-Gordon coefficients between the extreme m F states and the frequency detuning of the microwave electric field under the static magnetic field. The traceable measurement limit of weak electric field by EIT-AT splitting method was extended by an order of magnitude, which is promising for precise microwave electric field measurement.