Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1611.09998

Measuring magnetic field inside a microwave cavity via Rabi resonances in Cs atoms

Fuyu Sun, Dong Hou, Qingsong Bai, Xianhe Huang, Ma, Jie, Xiaofeng Li

Published Nov 30, 2016• 0 citations
arXivHTMLPDF

Abstract

We present a technique for measuring microwave (MW) field based on Rabi resonances induced by the interaction of atoms with a phase-modulated MW field. A theoretical model of field measurement is used to calculate Rabi frequency. Single-peak feature of the measurement model makes the technique a valuable tool for simple and fast field measurement. As an example, we use the technique to determine the MW field strength inside a Cs vapor cell in the X-band rectangular cavity for applied power in the range of -21 dBm to 20 dBm. The results show that this proposed technique is capable for detecting the field over a broad dynamical range.

DOI
10.48550/arxiv.1611.09998

Related papers

Rabi resonance in Cs atoms and its application to microwave magnetic field measurement

Fuyu Sun, Dong Hou, Qingsong Bai +1 more

We have recently presented a technique for measuring unknown microwave (MW) fields based on Rabi resonances induced by the interaction of atoms with a phase-modulated MW field. The single-peak feature of the measurement model makes the technique a valuable tool for simple and fast field measurement. Here we demonstrated a detailed investigation of Rabi resonance of Cs atoms inside a vapour cell. For illustration, we used the Rabi resonance-based field detection technique to determine the field strength inside an X-band cavity for applied power in the range of −21 to 20 dBm. The difference between the practical measurement and the simulation was approximately about 3% for an applied power of 20 dBm, and a higher accuracy could be expected for a larger power input.

Journal of Physics Communications•Dec 12, 2017•23 citations

Microwave magnetic field detection based on Cs vapor cell in free space

Xiaochi Liu, Zhiyuan Jiang, Jifeng Qu +3 more

In this study, we demonstrate the direct measurement of a microwave (MW) magnetic field through the detection of atomic Rabi resonances with Cs vapor cells in a free-space low-Q cavity. The line shape (amplitude and linewidth) of detected Rabi resonances is investigated versus several experimental parameters such as the laser intensity, cell buffer gas pressure, and cell length. The specially designed low-Q cavity creates a suitable MW environment allowing easy testing of different vapor cells with distinct properties. Obtained results are analyzed to optimize the performances of a MW magnetic field sensor based on the present atom-based detection technique.

Review of Scientific Instruments•Jun 1, 2018•29 citations

Microwave magnetic field imaging based on Rabi resonance with an alkali-atom vapor cell

Xiaochi Liu, Songbai Kang, Zhenfei Song +3 more

In this work, we demonstrate a microwave magnetic field imaging technique based on Rabi resonance with a cesium atom vapor cell. Rabi resonance signals are generated when atoms interact with a phase-modulated microwave (MW) field and are detected by a photodiode and camera. A low noise, high quantum efficiency camera is used to capture a series of frames for different phase modulation frequencies. Rabi frequencies of each spatial point in the field can be measured by scanning the frames. Thus, the strength of the MW magnetic field distribution is obtained by combing the Rabi frequencies, measured with camera pixels in the range of the probe laser beam. The simple architecture of this imaging setup holds great potential for the construction of compact/miniature MW field sensors for material testing, field imaging of MW components, and biomedical imaging.

arXiv:1902.06447•Feb 18, 2019•0 citations

Measuring microwave cavity response using atomic Rabi resonances

Fuyu Sun, Jie Ma, Qingsong Bai +3 more

In this letter, an atom-based approach for measuring the microwave (MW) cavity response (including cavity frequency and Q-factor) is presented, which utilizes a MW magnetic field detection technique based on atomic Rabi resonances. We first identify the Rabi resonances on seven π transitions in Cs atoms and demonstrate their uses in continuously frequency-tunable field detectors. With the atom-based field detectors, we then indicate the possibility of reconstructing the MW cavity response by measuring the MW frequency-dependent Rabi frequency (i.e., MW field strength) inside the cavity. To demonstrate this approach, we measured the response curves of a 9.2-GHz cavity and a cavity resonating at 8.3 GHz and 9.7 GHz using π transitions and σ transitions, respectively. We compared the results measured by our approach with those measured by Vector Networker Analyzer and obtained good agreement. From such atom-based, SI-traceable measurements, the MW cavity response can be linked directly to the Rabi frequency, which could be referred to an atomic clock.

Applied Physics Letters•Jul 31, 2017•41 citations

Microwave magnetic field sensing based on Rabi resonance using Rb vapor cell with anti-relaxation coating

Ning Ru, Xiaochi Liu, Jifeng Qu

Using a detection technique of microwave (MW) magnetic field based on Rabi resonance, we have constructed a SI-traceable MW magnetic field sensor. Unlike the uncoated cylindrical Cs vapor cell filled with buffer gas presented in our previous work, here we developed an experimental setup based on an alkali vapor cell with anti-relaxation coating. Rabi resonance signal lineshape are successfully observed when alkali atoms interact with a phase-modulated MW field. Several experimental parameters, such as optical laser intensity and cell temperature, are detailly studied and characterized. The optimal amplitude of Rabi resonance lineshape were obtained, which is well-agreed with the theoretical model.

IEEE International Conference on Signal, Information and Data Processing (ICSIDP)•Dec 1, 2019•0 citations

High-dynamic-range microwave sensing using atomic Rabi resonances

Dong Hou, Chao Li, Fuyu Sun +6 more

Detection of the microwave (MW) field with high accuracy is very important in the physical science and engineering fields. Herein, an atomic Rabi resonance-based MW magnetic field sensor with a high-dynamic-range is reported, where α and β Rabi resonances are used to measure MW fields. In MW measurement experiments, the sensor successfully measured a magnetic field of about 10 nT at 9.2 GHz using the α Rabi resonance line on the cesium clock transition and continuously detected the MW magnetic field in the X-band over a high dynamic power range of >60 dB from the β Rabi resonance. Finally, the MW power frequency shift and power broadening are investigated to support more sensitive field measurements. The proposed MW detection method can be extended to cover a higher dynamic range and a wider frequency band by applying stronger excitations and exploring non-clock atomic transitions, respectively. In addition to MW magnetic field sensing, other potential application of the proposed method can be explored, including SI-traceable MW calibration and atomic communication.

Review of Scientific Instruments•Feb 1, 2023•4 citations
We present a technique for measuring microwave (MW) field based on Rabi resonances induced by the interaction of atoms with a phase-modulated MW field. A theoretical model of field measurement is used to calculate Rabi frequency. Single-peak feature of the measurement model makes the technique a valuable tool for simple and fast field measurement. As an example, we use the technique to determine the MW field strength inside a Cs vapor cell in the X-band rectangular cavity for applied power in the range of -21 dBm to 20 dBm. The results show that this proposed technique is capable for detecting the field over a broad dynamical range.
We have recently presented a technique for measuring unknown microwave (MW) fields based on Rabi resonances induced by the interaction of atoms with a phase-modulated MW field. The single-peak feature of the measurement model makes the technique a valuable tool for simple and fast field measurement. Here we demonstrated a detailed investigation of Rabi resonance of Cs atoms inside a vapour cell. For illustration, we used the Rabi resonance-based field detection technique to determine the field strength inside an X-band cavity for applied power in the range of −21 to 20 dBm. The difference between the practical measurement and the simulation was approximately about 3% for an applied power of 20 dBm, and a higher accuracy could be expected for a larger power input.
In this study, we demonstrate the direct measurement of a microwave (MW) magnetic field through the detection of atomic Rabi resonances with Cs vapor cells in a free-space low-Q cavity. The line shape (amplitude and linewidth) of detected Rabi resonances is investigated versus several experimental parameters such as the laser intensity, cell buffer gas pressure, and cell length. The specially designed low-Q cavity creates a suitable MW environment allowing easy testing of different vapor cells with distinct properties. Obtained results are analyzed to optimize the performances of a MW magnetic field sensor based on the present atom-based detection technique.
In this work, we demonstrate a microwave magnetic field imaging technique based on Rabi resonance with a cesium atom vapor cell. Rabi resonance signals are generated when atoms interact with a phase-modulated microwave (MW) field and are detected by a photodiode and camera. A low noise, high quantum efficiency camera is used to capture a series of frames for different phase modulation frequencies. Rabi frequencies of each spatial point in the field can be measured by scanning the frames. Thus, the strength of the MW magnetic field distribution is obtained by combing the Rabi frequencies, measured with camera pixels in the range of the probe laser beam. The simple architecture of this imaging setup holds great potential for the construction of compact/miniature MW field sensors for material testing, field imaging of MW components, and biomedical imaging.
In this letter, an atom-based approach for measuring the microwave (MW) cavity response (including cavity frequency and Q-factor) is presented, which utilizes a MW magnetic field detection technique based on atomic Rabi resonances. We first identify the Rabi resonances on seven π transitions in Cs atoms and demonstrate their uses in continuously frequency-tunable field detectors. With the atom-based field detectors, we then indicate the possibility of reconstructing the MW cavity response by measuring the MW frequency-dependent Rabi frequency (i.e., MW field strength) inside the cavity. To demonstrate this approach, we measured the response curves of a 9.2-GHz cavity and a cavity resonating at 8.3 GHz and 9.7 GHz using π transitions and σ transitions, respectively. We compared the results measured by our approach with those measured by Vector Networker Analyzer and obtained good agreement. From such atom-based, SI-traceable measurements, the MW cavity response can be linked directly to the Rabi frequency, which could be referred to an atomic clock.
Using a detection technique of microwave (MW) magnetic field based on Rabi resonance, we have constructed a SI-traceable MW magnetic field sensor. Unlike the uncoated cylindrical Cs vapor cell filled with buffer gas presented in our previous work, here we developed an experimental setup based on an alkali vapor cell with anti-relaxation coating. Rabi resonance signal lineshape are successfully observed when alkali atoms interact with a phase-modulated MW field. Several experimental parameters, such as optical laser intensity and cell temperature, are detailly studied and characterized. The optimal amplitude of Rabi resonance lineshape were obtained, which is well-agreed with the theoretical model.
Detection of the microwave (MW) field with high accuracy is very important in the physical science and engineering fields. Herein, an atomic Rabi resonance-based MW magnetic field sensor with a high-dynamic-range is reported, where α and β Rabi resonances are used to measure MW fields. In MW measurement experiments, the sensor successfully measured a magnetic field of about 10 nT at 9.2 GHz using the α Rabi resonance line on the cesium clock transition and continuously detected the MW magnetic field in the X-band over a high dynamic power range of >60 dB from the β Rabi resonance. Finally, the MW power frequency shift and power broadening are investigated to support more sensitive field measurements. The proposed MW detection method can be extended to cover a higher dynamic range and a wider frequency band by applying stronger excitations and exploring non-clock atomic transitions, respectively. In addition to MW magnetic field sensing, other potential application of the proposed method can be explored, including SI-traceable MW calibration and atomic communication.