Low-Noise Wide Bandwith, Hot Electron Bolometer Mixers for Submillimeter Wavelengths

William R. McGrath

Published Sep 1, 1995• 0 citations
OpenAlex

Abstract

Recently a novel superconductive hot-electron micro-bolometer has been proposed which is both fast and sensitive (D. E. Prober, Appl. Phys. Lett. 62, 2119, 1993). This device has several important properties which make it useful as a heterodyne sensor for radioastronomy applications at frequencies above 1 THz. The thermal response time of the device is fast enough, several 10's of picoseconds, to allow for IF's of several GHz. This bolometer mixer should operate well up to at least 10 THz. There is no energy gap limitation as in an SIS mixer, since the mixing process relies on heating of the electron gas. In fact, rf power is absorbed more uniformly above the gap frequency. The mixer noise should be near quantum-limited, and the local oscillator (LO) power requirement is very low: / 10 nW for a Nb device. One of the unique features of this device is that it employs rapid electron diffusion into a normal metal, rather than phonon emission, as the thermal conductance that cools the heated electrons. In order for diffusion to dominate over phonon emission, the device must be short, less than 0.5.

Related papers

Low-noise and wideband hot-electron superconductive mixer for terahertz frequencies

Boris S. Karasik, Anders J. Skalare, William R. McGrath +7 more

Superconductive hot-electron bolometer (HEB) mixers have been built and tested in the frequency range from 1.1 THz to 2.5 THz. The mixer device is a 0.15 - 0.3 micrometer microbridge made from a 10 nm thick Nb film. This device employs diffusion as a cooling mechanism for hot electrons. The double sideband noise temperature was measured to be less than or equal to 3000 K at 2.5 THz and the mixer IF bandwidth is expected to be at least 10 GHz for a 0.1 micrometer long device. The local oscillator (LO) power dissipated in the HEB microbridge was 20 - 100 nW. Further improvement of the mixer characteristics can be potentially achieved by using Al microbridges. The advantages and parameters of such devices are evaluated. The HEB mixer is a primary candidate for ground based, airborne and spaceborne heterodyne instruments at THz frequencies. HEB receivers are planned for use on the NASA Stratospheric Observatory for Infrared Astronomy (SOFIA) and the ESA Far Infrared and Submillimeter Space Telescope (FIRST). The prospects of a submicron-size YBa2Cu3O7-(delta ) (YBCO) HEB are discussed. The expected LO power of 1 - 10 (mu) W and SSB noise temperature of approximately equals 2000 K may make this mixer attractive for various remote sensing applications.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Nov 13, 1998•1 citation

Low-noise and wideband hot-electron superconductive mixers for THz frequencies

Boris S. Karasik, Anders J. Skalare, Rolf A. Wyss +5 more

Superconductive hot-electron bolometer (HEB) mixers have been built and tested in the frequency range 1.1-2.5 THz. The mixer device is a 0.15-03 /spl mu/m microbridge made from a 10 nm thick Nb film. This device employs diffusion as a cooling mechanism for hot electrons. The double sideband noise temperature was measured to be /spl les/3000 K at 2.5 THz and the mixer IF bandwidth is /spl ap/9-10 GHz for a 0.1 /spl mu/m long device. The local oscillator (LO) power dissipated in the HEB microbridge was 20-100 nW. Further improvement of the mixer characteristics can be potentially achieved by using Al microbridges. The advantages and parameters of such devices are evaluated The HEB mixer Is a primary candidate for ground based, airborne and spaceborne heterodyne instruments at THz frequencies. HEB receivers are planned for use on the NASA Stratospheric Observatory for Infrared Astronomy (SOFIA) and the ESA Far Infrared and Submillimeter Space Telescope (FIRST). The prospects of a submicron-size YBa/sub 2/Cu/sub 3/O/sub 7-/spl delta// (YBCO) HEB are also discussed. The expected LO power of 1-10 /spl mu/W and SSB noise temperature of /spl ap/2000 K may make this mixer attractive for various remote sensing applications.

IEEE International Conference on Terahertz Electronics (THz)•Nov 27, 2002•5 citations

Aluminum hot-electron bolometer mixers at submillimeter wavelengths

Anders J. Skalare, William R. McGrath, P. M. Echternach +4 more

Diffusion-cooled aluminum hot-electron bolometer (HEB) mixers are of interest for low-noise high resolution THz-frequency spectroscopy within astrophysics. Al HEB mixers offer operation with an order of magnitude less local oscillator power, higher intermediate frequency bandwidth and potentially lower noise than competing devices made from other materials. We report on mixer experiments at 618 GHz with devices fabricated from films with sheet resistances in the range from about 55 /spl Omega/ down to about 9 /spl Omega/ per square. Intermediate frequency bandwidths of up to 3 GHz were measured (1 /spl mu/m long device), with absorbed local oscillator power levels of 0.5 to 6 nW and mixer conversion up to -21.5 dB. High input coupling efficiency implies that the electrons in the device are able to thermalize before escaping from the device. It was found that the long coherence length complicates mixer operations due to the proximity of the contact pads. Also, saturation at the IF frequency may be a concern for this type of device, and warrants further studies.

IEEE Transactions on Applied Superconductivity•Mar 1, 2001•17 citations

Fabrication of High-Tc Hot-Electron Bolometric Mixers for Submillimeter Heterodyne Applications

Michael J. Burns, Alan W. Kleinsasser, Boris S. Karasik +2 more

Superconducting hot-electron bolometers are the most promising candidate for heterodyne mixers at frequencies above 1 THz. These devices operate by heating of electrons in the superconductor, and thus have no energy gap related frequency limitation, such as exists in SIS mixers, for example. Nb hot-electron bolometric mixers have recently demonstrated superior performance to competing Schottky mixers at frequencies above 1 THz, but of course must be operated at liquid helium temperatures. YBa 2Cu307_,5 hot-electron bolometric mixers introduce the possibility of sensitive, low power heterodyne detectors operating at temperatures approaching 90 K for high-background applications, such as earth observing missions. We describe the fabrication of high-T, devices based on ultrathin (<20 nm) YBa2Cu307_ 5 films for use as 2.5 THz mixers.

•Jan 1, 1997•0 citations

Nb–Au bilayer hot-electron bolometers for low-noise THz heterodyne detection

Irfan A. Siddiqi, D. E. Prober

The sensitivity of present Nb diffusion-cooled hot-electron bolometer (HEB) mixers is not quantum limited, and can be improved by reducing the superconducting transition temperature TC. Lowering TC reduces thermal fluctuations, resulting in a decrease of the mixer noise temperature TM. However, lower TC mixers have reduced dynamic range and saturate more easily due to background noise. We present 30 GHz microwave measurements on a bilayer HEB system, Nb–Au, in which TC can be tuned with Au layer thickness to obtain the maximum sensitivity for a given noise background. These measurements are intended as a guide for the optimization of THz mixers. Using a Nb–Au mixer with TC=1.6 K, we obtain TM=50 K with 2 nW of local oscillator (LO) power. Good mixer performance is observed over a wide range of LO power and bias voltage and such a device should not exhibit saturation in a THz receiver.

Applied Physics Letters•Feb 12, 2004•8 citations

Hot-electron superconductive mixers for THz frequencies

William R. McGrath, Boris S. Karasik, Anders J. Skalare +3 more

Superconductive hot-electron bolometer (HEB) mixers have been built and tested in the frequency range from 1.1 THz to 2.5 THz. The mixer device employs diffusion as a cooling mechanism for hot electrons. The double sideband receiver noise temperature was measured to be approximately equals 2750 K at 2.5 K at 2.5 THz; and mixer IF bandwidths as high as 9 GHz are achieved for 0.1 micrometers long devices. The local oscillator power dissipated in the HEB microbridge was in the range 20- 100 nW. Further reductions in LO power and mixer noise can be potentially achieved by using Al microbridges. The advantages and parameters of such devices are evaluated. A distributed-temperature model has been developed to properly describe the operation of the diffusion-cooled HEB mixer. The HEB mixer is a primary candidate for ground based, airborne and spaceborne heterodyne instruments at THz frequencies.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 29, 1999•9 citations
Recently a novel superconductive hot-electron micro-bolometer has been proposed which is both fast and sensitive (D. E. Prober, Appl. Phys. Lett. 62, 2119, 1993). This device has several important properties which make it useful as a heterodyne sensor for radioastronomy applications at frequencies above 1 THz. The thermal response time of the device is fast enough, several 10's of picoseconds, to allow for IF's of several GHz. This bolometer mixer should operate well up to at least 10 THz. There is no energy gap limitation as in an SIS mixer, since the mixing process relies on heating of the electron gas. In fact, rf power is absorbed more uniformly above the gap frequency. The mixer noise should be near quantum-limited, and the local oscillator (LO) power requirement is very low: / 10 nW for a Nb device. One of the unique features of this device is that it employs rapid electron diffusion into a normal metal, rather than phonon emission, as the thermal conductance that cools the heated electrons. In order for diffusion to dominate over phonon emission, the device must be short, less than 0.5.
Superconductive hot-electron bolometer (HEB) mixers have been built and tested in the frequency range from 1.1 THz to 2.5 THz. The mixer device is a 0.15 - 0.3 micrometer microbridge made from a 10 nm thick Nb film. This device employs diffusion as a cooling mechanism for hot electrons. The double sideband noise temperature was measured to be less than or equal to 3000 K at 2.5 THz and the mixer IF bandwidth is expected to be at least 10 GHz for a 0.1 micrometer long device. The local oscillator (LO) power dissipated in the HEB microbridge was 20 - 100 nW. Further improvement of the mixer characteristics can be potentially achieved by using Al microbridges. The advantages and parameters of such devices are evaluated. The HEB mixer is a primary candidate for ground based, airborne and spaceborne heterodyne instruments at THz frequencies. HEB receivers are planned for use on the NASA Stratospheric Observatory for Infrared Astronomy (SOFIA) and the ESA Far Infrared and Submillimeter Space Telescope (FIRST). The prospects of a submicron-size YBa2Cu3O7-(delta ) (YBCO) HEB are discussed. The expected LO power of 1 - 10 (mu) W and SSB noise temperature of approximately equals 2000 K may make this mixer attractive for various remote sensing applications.
Superconductive hot-electron bolometer (HEB) mixers have been built and tested in the frequency range 1.1-2.5 THz. The mixer device is a 0.15-03 /spl mu/m microbridge made from a 10 nm thick Nb film. This device employs diffusion as a cooling mechanism for hot electrons. The double sideband noise temperature was measured to be /spl les/3000 K at 2.5 THz and the mixer IF bandwidth is /spl ap/9-10 GHz for a 0.1 /spl mu/m long device. The local oscillator (LO) power dissipated in the HEB microbridge was 20-100 nW. Further improvement of the mixer characteristics can be potentially achieved by using Al microbridges. The advantages and parameters of such devices are evaluated The HEB mixer Is a primary candidate for ground based, airborne and spaceborne heterodyne instruments at THz frequencies. HEB receivers are planned for use on the NASA Stratospheric Observatory for Infrared Astronomy (SOFIA) and the ESA Far Infrared and Submillimeter Space Telescope (FIRST). The prospects of a submicron-size YBa/sub 2/Cu/sub 3/O/sub 7-/spl delta// (YBCO) HEB are also discussed. The expected LO power of 1-10 /spl mu/W and SSB noise temperature of /spl ap/2000 K may make this mixer attractive for various remote sensing applications.
Diffusion-cooled aluminum hot-electron bolometer (HEB) mixers are of interest for low-noise high resolution THz-frequency spectroscopy within astrophysics. Al HEB mixers offer operation with an order of magnitude less local oscillator power, higher intermediate frequency bandwidth and potentially lower noise than competing devices made from other materials. We report on mixer experiments at 618 GHz with devices fabricated from films with sheet resistances in the range from about 55 /spl Omega/ down to about 9 /spl Omega/ per square. Intermediate frequency bandwidths of up to 3 GHz were measured (1 /spl mu/m long device), with absorbed local oscillator power levels of 0.5 to 6 nW and mixer conversion up to -21.5 dB. High input coupling efficiency implies that the electrons in the device are able to thermalize before escaping from the device. It was found that the long coherence length complicates mixer operations due to the proximity of the contact pads. Also, saturation at the IF frequency may be a concern for this type of device, and warrants further studies.
Superconducting hot-electron bolometers are the most promising candidate for heterodyne mixers at frequencies above 1 THz. These devices operate by heating of electrons in the superconductor, and thus have no energy gap related frequency limitation, such as exists in SIS mixers, for example. Nb hot-electron bolometric mixers have recently demonstrated superior performance to competing Schottky mixers at frequencies above 1 THz, but of course must be operated at liquid helium temperatures. YBa 2Cu307_,5 hot-electron bolometric mixers introduce the possibility of sensitive, low power heterodyne detectors operating at temperatures approaching 90 K for high-background applications, such as earth observing missions. We describe the fabrication of high-T, devices based on ultrathin (<20 nm) YBa2Cu307_ 5 films for use as 2.5 THz mixers.
The sensitivity of present Nb diffusion-cooled hot-electron bolometer (HEB) mixers is not quantum limited, and can be improved by reducing the superconducting transition temperature TC. Lowering TC reduces thermal fluctuations, resulting in a decrease of the mixer noise temperature TM. However, lower TC mixers have reduced dynamic range and saturate more easily due to background noise. We present 30 GHz microwave measurements on a bilayer HEB system, Nb–Au, in which TC can be tuned with Au layer thickness to obtain the maximum sensitivity for a given noise background. These measurements are intended as a guide for the optimization of THz mixers. Using a Nb–Au mixer with TC=1.6 K, we obtain TM=50 K with 2 nW of local oscillator (LO) power. Good mixer performance is observed over a wide range of LO power and bias voltage and such a device should not exhibit saturation in a THz receiver.
Superconductive hot-electron bolometer (HEB) mixers have been built and tested in the frequency range from 1.1 THz to 2.5 THz. The mixer device employs diffusion as a cooling mechanism for hot electrons. The double sideband receiver noise temperature was measured to be approximately equals 2750 K at 2.5 K at 2.5 THz; and mixer IF bandwidths as high as 9 GHz are achieved for 0.1 micrometers long devices. The local oscillator power dissipated in the HEB microbridge was in the range 20- 100 nW. Further reductions in LO power and mixer noise can be potentially achieved by using Al microbridges. The advantages and parameters of such devices are evaluated. A distributed-temperature model has been developed to properly describe the operation of the diffusion-cooled HEB mixer. The HEB mixer is a primary candidate for ground based, airborne and spaceborne heterodyne instruments at THz frequencies.