Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Acta Sinica Quantum Optica

相干反馈增强型量子混合干涉仪

刘攀 Pan LIU, 于志飞 Zhi-fei YU, 黄文峰 Wen-feng HUANG, 吴媛 Yuan WU, 陈丽清 Li-qing CHEN

Published Jan 1, 2023• 0 citations
Publisher

Abstract

In this paper, a quantum hybrid interferometer consisting of a nonlinear beam splitter and a linear beam splitter is proposed in theory. The nonlinear beam splitter is composed of a nonlinear parametric process combined with linear coherent feedback of a quantum squeezed source to improve the phase sensitivity of the quantum hybrid interferometer. Specifically, the optical parametric amplifier (OPA) output beam and the quantum squeezed source are linearly fed back to the input end to obtain a pair of dual-mode squeezed beams with controllable entanglement. Combined with the linear beam combination, the feedback quantum hybrid interferometer is constructed. The results show that compared with the non-feedback quantum hybrid interferometer, the scheme can increase the number of phase-sensitive photons by adjusting the feedback intensity to an appropriate range to improve the interference signal intensity and enhance the degree of entanglement between the two interference arms to reduce the interference noise. In addition, the squeezed vacuum state as the input state of the feedback loop structure can further reduce the noise of the detection signal. Therefore, this scheme can effectively improve the measurement sensitivity of the hybrid interferometer from the above three aspects. Even in the case of lossy, the feedback quantum hybrid interferometer compared with without feedback still has better phase sensitivity and anti-damage ability, which is expected to be applied in the field of quantum metrology.

DOI
10.3788/jqo20232902.0202

Related papers

基于光学参量放大器反馈的非线性干涉仪

符婧 Fu Jing, 王绪彤 Wang Xutong, 刘胜帅 Liu Shengshuai +1 more

High-precision interferometers play a critical role in the field of metrology. The uncertainty of phase estimation can be used to evaluate the precision of an interferometer. The lower the uncertainty of phase estimation, the higher the phase sensitivity. We theoretically propose a nonlinear interferometer composed of an optical parametric amplifier and a linear optical beam splitter (BS). An optical parametric amplifier based on the hot rubidium-85 atomic ensemble four-wave mixing (FWM) process is used to combine and separate the beams in the interferometer. As a feedback controller, the BS controls the proportion of the output light returning to the input light port in the FWM process by controlling the reflectivity of the device. Through theoretical calculations, it is proved that the phase sensitivity of a nonlinear interferometer based on optical parametric amplifier feedback is enhanced compared with that of traditional interferometers. Our research results are expected to have potential applications in the field of quantum metrology.

Laser & Optoelectronics Progress•Jan 1, 2023•3 citations

Enhancement of the phase-measurement sensitivity beyond the standard quantum limit by a nonlinear interferometer

Z. Y. Ou

A nonlinear interferometer uses nonlinear elements as beam splitters to split and to recombine optical waves for interference. As a result, the interference fringe size has a nonlinear dependence on the intensity of the field for phase sensing and leads to an enhanced phase signal. In this paper, a practical scheme of nonlinear interferometry for precision phase measurement is analyzed with parametric amplifiers as the nonlinear beam splitters. It is found that the signal due to phase shift is enhanced by a factor of the amplification gain as compared to a linear interferometer with the same phase-sensing light intensity while the quantum noise is kept at the vacuum level, thus, effectively increasing the signal-to-noise ratio (SNR) beyond the standard quantum limit. Furthermore, the scheme is not as sensitive to the detection loss as the linear scheme with a squeezed state for noise reduction. However, losses inside the interferometer limit the enhancement factor in SNR. We apply the concept to a Michelson interferometer but with parametric amplifiers involved for gravitational-wave detection. We find that effective power is increased by the gain of the amplifiers without actually increasing the cycling power inside the interferometer. Furthermore, the full benefits with squeezed input and variational output or the combination of a quantum nondemolition interferometer for sensitivity beyond the standard quantum limit apply here with even better results. Such a nonlinear interferometer will find wide applications in precision measurements.

Physical Review A•Feb 14, 2012•199 citations

相干反馈的级联简并光学参量放大器量子特性研究

黄东海 Donghai HUANG, 付佳佳 Jiajia FU, 卢建刚 Jiangang LU +4 more

ObjectiveThe squeezed states can not only verify the fundamental principles of quantum physics, but also have important applications in the field of quantum information processing. In the field of quantum communications, the speed and fidelity of communication depend on the squeezing degree of the squeezed states. A degenerated optical parametric amplifier (DOPA) is efficient approach on the production of the squeezed states. In the paper, a coherent feedback controlled cascaded DOPA on the squeezing enhancement is discussed.MethodsBase on quantum Langevin equation, the input-output relation of the quadratures noise of the output field can be obtained. The output of the first DOPA is seeded to the second DOPA. Then, the noise of the light from the second DOPA can also be obtained. Further, the output of the second DOPA is partially feed back to the input of the first DOPA through a beam splitter. Based on the input-output relation of the beam splitter, the noise formula of the coherent feedback controlled cascaded DOPA is acquired.Results and DiscussionsBased on the noise formula, the dependence of squeezing from the coherent feedback controlled cascaded DOPA on feedback intensity, the phase delay of the feedback loop, pump parameter, the propagation loss of the feedback loop is numerically simulated and presented in the paper. These results show that the squeezing can be significantly enhanced with a certain parameter range.ConclusionsThis paper discusses a cascaded DOPA with coherent feedback, which uses a beam splitter as a feedback controller to feed the squeezed light output from the cascaded DOPA back to the input port. Our research results show that within a certain range of feedback intensity and specific feedback phase, coherent feedback can further enhance the quantum squeezing characteristics of the output light field from a cascaded DOPA. The paper has also studied the dependence of squeezing enhancement effect on system physical parameters. The research results of this paper can provide theoretical reference for improving the squeezing of the squeezed light for the short-wavelength range, laying the foundation for their application in quantum communication and quantum information fields.

Acta Sinica Quantum Optica•Jan 1, 2025•0 citations

Quantum metrology with parametric amplifier-based photon correlation interferometers

Florian Hudelist, Jia Kong, Cunjin Liu +3 more

Conventional interferometers usually utilize beam splitters for wave splitting and recombination. These interferometers are widely used for precision measurement. Their sensitivity for phase measurement is limited by the shot noise, which can be suppressed with squeezed states of light. Here we study a new type of interferometer in which the beam splitting and recombination elements are parametric amplifiers. We observe an improvement of 4.1±0.3 dB in signal-to-noise ratio compared with a conventional interferometer under the same operating condition, which is a 1.6-fold enhancement in rms phase measurement sensitivity beyond the shot noise limit. The improvement is due to signal enhancement. Combined with the squeezed state technique for shot noise suppression, this interferometer promises further improvement in sensitivity. Furthermore, because nonlinear processes are involved in this interferometer, we can couple a variety of different waves and form new types of hybrid interferometers, opening a door for many applications in metrology. Interferometers play a key role in precision measurements and metrology. Here, the authors demonstrate a new type of interferometer that replaces the standard beam splitter elements with parametric amplifiers, which provides enhanced performance compared with a Mach–Zehnder interferometer.

Nature Communications•Jan 29, 2014•472 citations

Nonlinear Sagnac fiber interferometer based on coherent feedback control

Xiaoyu Feng, Min Nie, Guang Yang

In order to improve the phase sensitivity of nonlinear Sagnac interferometer, a nonlinear Sagnac fiber optic interferometer based on feedback control is designed to improve the phase sensitivity by introducing a feedback control loop into the nonlinear Sagnac interferometer. This design adopts the composite feedback control structure of Nonlinear Beam Splitter (NBS) and Linear Beam Splitter (BS). By adjusting the reflectivity of the Linear Beam Splitter, the intensity of the feedback signal can be effectively changed to regulate the phase sensitivity of the interferometer. The feedback amplified signal light passes through the Sagnac fiber optic ring before being processed by a second NBS for quantum enhancement to further improve the phase sensitivity of the interferometer. The simulation results show that the phase sensitivity of the interferometer with certain feedback strength is better than that without feedback. Especially when the phase difference is π, the phase sensitivity of the interferometer with low and medium feedback strengths is improved by 33.3% and 28.9% respectively; In addition, the gain coefficient of the NBS is a key parameter affecting the performance of the interferometer, and a suitable gain coefficient can further optimize the phase sensitivity of the interferometer.

International Conference on Optoelectronic Information and Optical Engineering (OIOE)•Jun 10, 2025•0 citations

High sensitivity quantum Michelson interferometer

Zuo Xiao-Jie, Sun Ying-Rong, Yan Zhi-Hui +1 more

Michelson interferometer can be applied to not only the building block of the fundamental research of physics, but also the precise measurement, such as the direct observation of gravity wave signal. Therefore, high performance Michelson interferometer is the key step towards the implementation of direct observation of weak gravity wave signal. Recently, the vacuum noise was reduced by injecting squeezed vacuum into the unused port of Michelson interferomter, and the phase signal optical field in Mach-Zender interferometer is amplified based on the four-wave mixing in hot Rubidium atom. Here we study high sensitivity quantum Michelson interferometer. In the Michelson interferometer, the linear optical beam splitter is replaced by a non-degenerated optical parametric amplifier to realize the splitting and combining of optical fields, and the squeezed vacuum is also injected into the unused port of interferomter, so that the high signal-to-noise ratio and high sensitivity of phase measurement can be realized. Due to the inevitable optical losses, the losses inside and outside the Michelson interferometer are considered in our theoretical model. We investigate the influences of the losses inside and outside the Michelson interferometer on the sensitivity of phase measurement. By theoretical calculation, we analyze the dependence of sensitivity of phase measurement on system parameters, such as intensity of optical fields for phase sensing, gain factor of non-degenerated optical parametric amplifier, the losses inside and outside the Michelson interferometer, and the squeezing parameter of input squeezed vacuum, and thus the condition of high sensitivity nonlinear Michelson interferometer can be obtained. In a broad system parametric range, the quantum Michaleson interferometer can surpass standard quantum limit, and the nonlinear Michaleson interferometer with squeezed state injection can provide the optimal sensitivity for phase measurement. The nonlinear Michelson interferometer with squeezed state is suitable for weak signal measurement. While the gain factor of non-degenerated optical parametric amplifier is large enough, the nonlinear Michelson interferometer without injecting the squeezed vacuum can still reach the optimal sensitivity, which reduces the use of quantum resources. When the phase sensing optical field is strong, the linear Michelson interferometer with injecting the squeezed vacuum can also reach the optimal sensitivity, and the sensitivity is robust for both losses inside and outside the interferometer. All the kinds of interferometers are more sensitive to the loss inside the interferometer than outside the interferometer, and the sensitivity of phase measurement can be improved by reducing the loss inside the interferometer. Our result provides direct reference of experimental implementation of high performance interferometer for high precision quantum metrology.

Acta Physica Sinica•Jan 1, 2018•3 citations
In this paper, a quantum hybrid interferometer consisting of a nonlinear beam splitter and a linear beam splitter is proposed in theory. The nonlinear beam splitter is composed of a nonlinear parametric process combined with linear coherent feedback of a quantum squeezed source to improve the phase sensitivity of the quantum hybrid interferometer. Specifically, the optical parametric amplifier (OPA) output beam and the quantum squeezed source are linearly fed back to the input end to obtain a pair of dual-mode squeezed beams with controllable entanglement. Combined with the linear beam combination, the feedback quantum hybrid interferometer is constructed. The results show that compared with the non-feedback quantum hybrid interferometer, the scheme can increase the number of phase-sensitive photons by adjusting the feedback intensity to an appropriate range to improve the interference signal intensity and enhance the degree of entanglement between the two interference arms to reduce the interference noise. In addition, the squeezed vacuum state as the input state of the feedback loop structure can further reduce the noise of the detection signal. Therefore, this scheme can effectively improve the measurement sensitivity of the hybrid interferometer from the above three aspects. Even in the case of lossy, the feedback quantum hybrid interferometer compared with without feedback still has better phase sensitivity and anti-damage ability, which is expected to be applied in the field of quantum metrology.
High-precision interferometers play a critical role in the field of metrology. The uncertainty of phase estimation can be used to evaluate the precision of an interferometer. The lower the uncertainty of phase estimation, the higher the phase sensitivity. We theoretically propose a nonlinear interferometer composed of an optical parametric amplifier and a linear optical beam splitter (BS). An optical parametric amplifier based on the hot rubidium-85 atomic ensemble four-wave mixing (FWM) process is used to combine and separate the beams in the interferometer. As a feedback controller, the BS controls the proportion of the output light returning to the input light port in the FWM process by controlling the reflectivity of the device. Through theoretical calculations, it is proved that the phase sensitivity of a nonlinear interferometer based on optical parametric amplifier feedback is enhanced compared with that of traditional interferometers. Our research results are expected to have potential applications in the field of quantum metrology.
A nonlinear interferometer uses nonlinear elements as beam splitters to split and to recombine optical waves for interference. As a result, the interference fringe size has a nonlinear dependence on the intensity of the field for phase sensing and leads to an enhanced phase signal. In this paper, a practical scheme of nonlinear interferometry for precision phase measurement is analyzed with parametric amplifiers as the nonlinear beam splitters. It is found that the signal due to phase shift is enhanced by a factor of the amplification gain as compared to a linear interferometer with the same phase-sensing light intensity while the quantum noise is kept at the vacuum level, thus, effectively increasing the signal-to-noise ratio (SNR) beyond the standard quantum limit. Furthermore, the scheme is not as sensitive to the detection loss as the linear scheme with a squeezed state for noise reduction. However, losses inside the interferometer limit the enhancement factor in SNR. We apply the concept to a Michelson interferometer but with parametric amplifiers involved for gravitational-wave detection. We find that effective power is increased by the gain of the amplifiers without actually increasing the cycling power inside the interferometer. Furthermore, the full benefits with squeezed input and variational output or the combination of a quantum nondemolition interferometer for sensitivity beyond the standard quantum limit apply here with even better results. Such a nonlinear interferometer will find wide applications in precision measurements.
ObjectiveThe squeezed states can not only verify the fundamental principles of quantum physics, but also have important applications in the field of quantum information processing. In the field of quantum communications, the speed and fidelity of communication depend on the squeezing degree of the squeezed states. A degenerated optical parametric amplifier (DOPA) is efficient approach on the production of the squeezed states. In the paper, a coherent feedback controlled cascaded DOPA on the squeezing enhancement is discussed.MethodsBase on quantum Langevin equation, the input-output relation of the quadratures noise of the output field can be obtained. The output of the first DOPA is seeded to the second DOPA. Then, the noise of the light from the second DOPA can also be obtained. Further, the output of the second DOPA is partially feed back to the input of the first DOPA through a beam splitter. Based on the input-output relation of the beam splitter, the noise formula of the coherent feedback controlled cascaded DOPA is acquired.Results and DiscussionsBased on the noise formula, the dependence of squeezing from the coherent feedback controlled cascaded DOPA on feedback intensity, the phase delay of the feedback loop, pump parameter, the propagation loss of the feedback loop is numerically simulated and presented in the paper. These results show that the squeezing can be significantly enhanced with a certain parameter range.ConclusionsThis paper discusses a cascaded DOPA with coherent feedback, which uses a beam splitter as a feedback controller to feed the squeezed light output from the cascaded DOPA back to the input port. Our research results show that within a certain range of feedback intensity and specific feedback phase, coherent feedback can further enhance the quantum squeezing characteristics of the output light field from a cascaded DOPA. The paper has also studied the dependence of squeezing enhancement effect on system physical parameters. The research results of this paper can provide theoretical reference for improving the squeezing of the squeezed light for the short-wavelength range, laying the foundation for their application in quantum communication and quantum information fields.
Conventional interferometers usually utilize beam splitters for wave splitting and recombination. These interferometers are widely used for precision measurement. Their sensitivity for phase measurement is limited by the shot noise, which can be suppressed with squeezed states of light. Here we study a new type of interferometer in which the beam splitting and recombination elements are parametric amplifiers. We observe an improvement of 4.1±0.3 dB in signal-to-noise ratio compared with a conventional interferometer under the same operating condition, which is a 1.6-fold enhancement in rms phase measurement sensitivity beyond the shot noise limit. The improvement is due to signal enhancement. Combined with the squeezed state technique for shot noise suppression, this interferometer promises further improvement in sensitivity. Furthermore, because nonlinear processes are involved in this interferometer, we can couple a variety of different waves and form new types of hybrid interferometers, opening a door for many applications in metrology. Interferometers play a key role in precision measurements and metrology. Here, the authors demonstrate a new type of interferometer that replaces the standard beam splitter elements with parametric amplifiers, which provides enhanced performance compared with a Mach–Zehnder interferometer.
In order to improve the phase sensitivity of nonlinear Sagnac interferometer, a nonlinear Sagnac fiber optic interferometer based on feedback control is designed to improve the phase sensitivity by introducing a feedback control loop into the nonlinear Sagnac interferometer. This design adopts the composite feedback control structure of Nonlinear Beam Splitter (NBS) and Linear Beam Splitter (BS). By adjusting the reflectivity of the Linear Beam Splitter, the intensity of the feedback signal can be effectively changed to regulate the phase sensitivity of the interferometer. The feedback amplified signal light passes through the Sagnac fiber optic ring before being processed by a second NBS for quantum enhancement to further improve the phase sensitivity of the interferometer. The simulation results show that the phase sensitivity of the interferometer with certain feedback strength is better than that without feedback. Especially when the phase difference is π, the phase sensitivity of the interferometer with low and medium feedback strengths is improved by 33.3% and 28.9% respectively; In addition, the gain coefficient of the NBS is a key parameter affecting the performance of the interferometer, and a suitable gain coefficient can further optimize the phase sensitivity of the interferometer.
Michelson interferometer can be applied to not only the building block of the fundamental research of physics, but also the precise measurement, such as the direct observation of gravity wave signal. Therefore, high performance Michelson interferometer is the key step towards the implementation of direct observation of weak gravity wave signal. Recently, the vacuum noise was reduced by injecting squeezed vacuum into the unused port of Michelson interferomter, and the phase signal optical field in Mach-Zender interferometer is amplified based on the four-wave mixing in hot Rubidium atom. Here we study high sensitivity quantum Michelson interferometer. In the Michelson interferometer, the linear optical beam splitter is replaced by a non-degenerated optical parametric amplifier to realize the splitting and combining of optical fields, and the squeezed vacuum is also injected into the unused port of interferomter, so that the high signal-to-noise ratio and high sensitivity of phase measurement can be realized. Due to the inevitable optical losses, the losses inside and outside the Michelson interferometer are considered in our theoretical model. We investigate the influences of the losses inside and outside the Michelson interferometer on the sensitivity of phase measurement. By theoretical calculation, we analyze the dependence of sensitivity of phase measurement on system parameters, such as intensity of optical fields for phase sensing, gain factor of non-degenerated optical parametric amplifier, the losses inside and outside the Michelson interferometer, and the squeezing parameter of input squeezed vacuum, and thus the condition of high sensitivity nonlinear Michelson interferometer can be obtained. In a broad system parametric range, the quantum Michaleson interferometer can surpass standard quantum limit, and the nonlinear Michaleson interferometer with squeezed state injection can provide the optimal sensitivity for phase measurement. The nonlinear Michelson interferometer with squeezed state is suitable for weak signal measurement. While the gain factor of non-degenerated optical parametric amplifier is large enough, the nonlinear Michelson interferometer without injecting the squeezed vacuum can still reach the optimal sensitivity, which reduces the use of quantum resources. When the phase sensing optical field is strong, the linear Michelson interferometer with injecting the squeezed vacuum can also reach the optimal sensitivity, and the sensitivity is robust for both losses inside and outside the interferometer. All the kinds of interferometers are more sensitive to the loss inside the interferometer than outside the interferometer, and the sensitivity of phase measurement can be improved by reducing the loss inside the interferometer. Our result provides direct reference of experimental implementation of high performance interferometer for high precision quantum metrology.