Michelson interferometer can be applied to not only the building block of the fundamental research of physics, but also the precise measurement, such as the direct observation of gravity wave signal. Therefore, high performance Michelson interferometer is the key step towards the implementation of direct observation of weak gravity wave signal. Recently, the vacuum noise was reduced by injecting squeezed vacuum into the unused port of Michelson interferomter, and the phase signal optical field in Mach-Zender interferometer is amplified based on the four-wave mixing in hot Rubidium atom. Here we study high sensitivity quantum Michelson interferometer. In the Michelson interferometer, the linear optical beam splitter is replaced by a non-degenerated optical parametric amplifier to realize the splitting and combining of optical fields, and the squeezed vacuum is also injected into the unused port of interferomter, so that the high signal-to-noise ratio and high sensitivity of phase measurement can be realized. Due to the inevitable optical losses, the losses inside and outside the Michelson interferometer are considered in our theoretical model. We investigate the influences of the losses inside and outside the Michelson interferometer on the sensitivity of phase measurement. By theoretical calculation, we analyze the dependence of sensitivity of phase measurement on system parameters, such as intensity of optical fields for phase sensing, gain factor of non-degenerated optical parametric amplifier, the losses inside and outside the Michelson interferometer, and the squeezing parameter of input squeezed vacuum, and thus the condition of high sensitivity nonlinear Michelson interferometer can be obtained. In a broad system parametric range, the quantum Michaleson interferometer can surpass standard quantum limit, and the nonlinear Michaleson interferometer with squeezed state injection can provide the optimal sensitivity for phase measurement. The nonlinear Michelson interferometer with squeezed state is suitable for weak signal measurement. While the gain factor of non-degenerated optical parametric amplifier is large enough, the nonlinear Michelson interferometer without injecting the squeezed vacuum can still reach the optimal sensitivity, which reduces the use of quantum resources. When the phase sensing optical field is strong, the linear Michelson interferometer with injecting the squeezed vacuum can also reach the optimal sensitivity, and the sensitivity is robust for both losses inside and outside the interferometer. All the kinds of interferometers are more sensitive to the loss inside the interferometer than outside the interferometer, and the sensitivity of phase measurement can be improved by reducing the loss inside the interferometer. Our result provides direct reference of experimental implementation of high performance interferometer for high precision quantum metrology.
Michelson interferometer can be applied to not only the building block of the fundamental research of physics, but also the precise measurement, such as the direct observation of gravity wave signal. Therefore, high performance Michelson interferometer is the key step towards the implementation of direct observation of weak gravity wave signal. Recently, the vacuum noise was reduced by injecting squeezed vacuum into the unused port of Michelson interferomter, and the phase signal optical field in Mach-Zender interferometer is amplified based on the four-wave mixing in hot Rubidium atom. Here we study high sensitivity quantum Michelson interferometer. In the Michelson interferometer, the linear optical beam splitter is replaced by a non-degenerated optical parametric amplifier to realize the splitting and combining of optical fields, and the squeezed vacuum is also injected into the unused port of interferomter, so that the high signal-to-noise ratio and high sensitivity of phase measurement can be realized. Due to the inevitable optical losses, the losses inside and outside the Michelson interferometer are considered in our theoretical model. We investigate the influences of the losses inside and outside the Michelson interferometer on the sensitivity of phase measurement. By theoretical calculation, we analyze the dependence of sensitivity of phase measurement on system parameters, such as intensity of optical fields for phase sensing, gain factor of non-degenerated optical parametric amplifier, the losses inside and outside the Michelson interferometer, and the squeezing parameter of input squeezed vacuum, and thus the condition of high sensitivity nonlinear Michelson interferometer can be obtained. In a broad system parametric range, the quantum Michaleson interferometer can surpass standard quantum limit, and the nonlinear Michaleson interferometer with squeezed state injection can provide the optimal sensitivity for phase measurement. The nonlinear Michelson interferometer with squeezed state is suitable for weak signal measurement. While the gain factor of non-degenerated optical parametric amplifier is large enough, the nonlinear Michelson interferometer without injecting the squeezed vacuum can still reach the optimal sensitivity, which reduces the use of quantum resources. When the phase sensing optical field is strong, the linear Michelson interferometer with injecting the squeezed vacuum can also reach the optimal sensitivity, and the sensitivity is robust for both losses inside and outside the interferometer. All the kinds of interferometers are more sensitive to the loss inside the interferometer than outside the interferometer, and the sensitivity of phase measurement can be improved by reducing the loss inside the interferometer. Our result provides direct reference of experimental implementation of high performance interferometer for high precision quantum metrology.
High-sensitivity interferometers are one of the basic tools for precision measurement, and their sensitivity is limited by their shot noise limit (SNL), which is determined by vacuum fluctuations of the probe field. The quantum interferometer with novel structures can break the SNL and measure the weak signals, such as the direct observation of gravity wave signal. Combining classical interferometers and the optical parametric amplifier (OPA) can enhance the signal; meanwhile, the quantum noise is kept at the vacuum level, so that the sensitivity of the nonlinear interferometer beyond the SNL can be achieved. By analyzing in detail the influence of system parameters on the precision of quantum metrology, including the intensity of optical fields for phase sensing, the gain factor of OPA, and the losses inside and outside the interferometers, the application conditions of high-sensitivity nonlinear quantum interferometers are obtained. Quantum interferometer-based OPAs provide the direct references for the practical development of quantum precise measurement.
A nonlinear interferometer uses nonlinear elements as beam splitters to split and to recombine optical waves for interference. As a result, the interference fringe size has a nonlinear dependence on the intensity of the field for phase sensing and leads to an enhanced phase signal. In this paper, a practical scheme of nonlinear interferometry for precision phase measurement is analyzed with parametric amplifiers as the nonlinear beam splitters. It is found that the signal due to phase shift is enhanced by a factor of the amplification gain as compared to a linear interferometer with the same phase-sensing light intensity while the quantum noise is kept at the vacuum level, thus, effectively increasing the signal-to-noise ratio (SNR) beyond the standard quantum limit. Furthermore, the scheme is not as sensitive to the detection loss as the linear scheme with a squeezed state for noise reduction. However, losses inside the interferometer limit the enhancement factor in SNR. We apply the concept to a Michelson interferometer but with parametric amplifiers involved for gravitational-wave detection. We find that effective power is increased by the gain of the amplifiers without actually increasing the cycling power inside the interferometer. Furthermore, the full benefits with squeezed input and variational output or the combination of a quantum nondemolition interferometer for sensitivity beyond the standard quantum limit apply here with even better results. Such a nonlinear interferometer will find wide applications in precision measurements.
An important part of optical sensing is interferometry, where direct or homodyne detection at the output of an interferometer yields information about small phase shifts. Classical interferometry operates at the shot-noise limit (SNL), caused by the photon structure of light and reached when an interferometer is fed with coherent light. The use of nonclassical light at the input of an interferometer enables overcoming the SNL. In particular, squeezed light is known to be less noisy than coherent light. An interferometer fed with strongly squeezed light can, in principle, provide the phase sensitivity at the Heisenberg limit, the ultimate limit allowed by the laws of physics. However, this supersensitive operation is strongly degraded by loss – both inside the interferometer and outside it, at the stage of detection. While the former (internal loss) seems to be inevitable, the latter (detection loss) can be overcome, and we demonstrate it in our recent experiment. The clue is to amplify light at the interferometer output using a phase-sensitive optical parametric amplifier. This device does not introduce additional noise, but it amplifies the fragile quantum signal and thus makes it tolerant to loss at the detection stage. In a proof-of-principle experiment, we build a polarization Mach-Zehnder interferometer and feed it with coherent light in one port and a squeezed vacuum in another port. At one output port, we amplify light with an optical parametric amplifier and measure a phase sensitivity of 13 mrad for 1500 photons in the interferometer. This result, achieved with 50% detection efficiency, overcomes the SNL by 3 dB. Moreover, by using stronger amplification, we can overcome the SNL under detection efficiency as low as 13%. Our results outline a way to use squeezed light for real-life sensing, where the detection efficiency cannot be very high, especially in spectral ranges like middle-infrared or terahertz.
In this paper, a quantum hybrid interferometer consisting of a nonlinear beam splitter and a linear beam splitter is proposed in theory. The nonlinear beam splitter is composed of a nonlinear parametric process combined with linear coherent feedback of a quantum squeezed source to improve the phase sensitivity of the quantum hybrid interferometer. Specifically, the optical parametric amplifier (OPA) output beam and the quantum squeezed source are linearly fed back to the input end to obtain a pair of dual-mode squeezed beams with controllable entanglement. Combined with the linear beam combination, the feedback quantum hybrid interferometer is constructed. The results show that compared with the non-feedback quantum hybrid interferometer, the scheme can increase the number of phase-sensitive photons by adjusting the feedback intensity to an appropriate range to improve the interference signal intensity and enhance the degree of entanglement between the two interference arms to reduce the interference noise. In addition, the squeezed vacuum state as the input state of the feedback loop structure can further reduce the noise of the detection signal. Therefore, this scheme can effectively improve the measurement sensitivity of the hybrid interferometer from the above three aspects. Even in the case of lossy, the feedback quantum hybrid interferometer compared with without feedback still has better phase sensitivity and anti-damage ability, which is expected to be applied in the field of quantum metrology.
Significance A quantum interferometer is one of the core tools in the field of quantum precision measurement, combining quantum manipulation technology with interferometric measurement technology to achieve precision measurements beyond classical limits. Leveraging the advantages of quantum resources, this technology demonstrates significant application potential in quantum sensing fields such as displacement measurement, imaging, magnetic field measurement, angular velocity measurement, and electric field measurement. The typical workflow of a quantum interferometer includes quantum state preparation, phase modulation, interferometric measurement, and signal extraction. Based on interferometer structures, they are primarily classified into two types: linear interferometers and nonlinear interferometers. The core principle of linear quantum interferometers is to utilize the linear coherent superposition and interference effects of quantum states for phase measurement. This architecture combines the advantages of classical interferometers in terms of large phase-sensitive particle numbers with quantum advantages and high measurement precision, and has been successfully applied to quantum-enhanced detection of gravitational waves. Unlike linear quantum interferometers, nonlinear quantum interferometers utilize nonlinear interactions to control the interference process of quantum states. Their primary operational mechanisms include nonlinear phase-sensitive amplification and quantum correlation enhancement. As a result, they possess inherent advantages in suppressing nonlinear noise and amplifying signals, demonstrating greater adaptability in terms of environmental robustness. Optimization research on quantum interferometers will break through classical limits, laying the technological foundation for practical applications in the field of quantum sensing. Progress In the field of quantum interferometers, researchers have proposed and realized two configurations: linear interference (Fig. 1) and nonlinear interference (Fig. 2). Additionally, they have innovatively proposed a hybrid interferometer combining light and atoms on the physical carrier of the interference arm (Fig. 3). Due to the inherent fragility and complexity of quantum resources, the challenge of how to fully leverage quantum advantages in lossy environments to enhance the phase sensitivity of quantum interferometers has become a key obstacle to advancing their practical applications. In linear quantum interferometers, researchers have proposed optimal quantum resource allocation schemes (Fig. 5) to address internal losses and optimized quantum amplification compensation schemes (Fig. 6) to address external losses. Both types of schemes can reduce the impact of losses on quantum resources. In nonlinear quantum interferometers, researchers have proposed various optimization schemes, including: an asymmetric gain optimization scheme applicable to both external (Fig. 7) and internal (Fig. 8) losses; coherent feedback optimization (Fig. 9); and photon-level operations (Fig. 10). In the application field of quantum interferometers, typical technological breakthroughs include: LIGO achieving a 3 dB quantum noise advantage in low-frequency (around 50 Hz) gravitational wave detection (Fig. 11); approximately 1.2 dB electric field quantum enhancement measurement being achieved using common-path interference (Fig. 12); achieving a 5.5 dB quantum enhancement measurement of magnetic fields using entangled beams generated via four-wave mixing, with sensitivity reaching 18 fT/(cm?Hz) at 20 Hz (Fig. 13); achieving approximately 0.95 (°)/h angular rate bias stability by combining entangled photon pairs with a fiber-optic gyroscope (Fig. 14); quantum interference effects being used to suppress four-wave mixing noise in quantum memory (Fig. 15); a photon number quantum non-destructive measurement scheme based on light-atom hybrid interference being proposed (Fig. 16). Additionally, to maintain long-term stability of the quantum state, a multi-parameter dynamic optimization model constructed using deep neural networks is employed to achieve stable quantum state output for 2 h (Fig. 17). Conclusions and Prospects Quantum interferometers surpass the standard quantum limit (SQL) by leveraging quantum state resources, yet their phase sensitivity advantage is highly susceptible to degradation from photon loss and limited detection efficiency. Maintaining this quantum advantage presents a core challenge: achieving stable, high-sensitivity quantum manipulation. This paper systematically reviews research progress in this field. Theoretically, new mechanisms like optimal resource allocation and gain compensation have been developed. Technically, key breakthroughs include high-loss-tolerant designs and noise suppression techniques. Although existing loss mitigation schemes show significant promise, the fundamental problem of absolute sensitivity decaying with loss remains unresolved. Notably, multi-parameter control techniques based on artificial intelligence have effectively enhanced quantum light source stability, offering new pathways to suppress environmental disturbances. Developing intelligent control methods to simultaneously address quantum decoherence and phase instability will be critical for realizing practical quantum precision measurement systems.
We theoretically study the phase sensitivity of an SU(1,1) interferometer with a coherent state in one input port and a squeezed-vacuum state in the other input port using the method of homodyne detection. In this interferometer, beam splitting and recombination are generated by the parametric amplifiers instead of the beam splitters. Compared with the traditional Mach–Zehnder interferometer, the phase sensitivity of this interferometer can be improved due to the amplification process of the parametric amplifiers. Combined with the squeezed state input, the sensitivity can be improved further due to the noise reduction. The phase sensitivity of our scheme can approach the Heisenberg limit and the associated optimal condition is analyzed. The scheme can be implemented with current experimental technology.