Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optical and Quantum Sensing and Precision Metrology II

Atomic magnetometer based on electromagnetically induced transparency (EIT)

Mario Alberto González Maldonado

Published Mar 19, 2025• 0 citations
Publisher
DOI
10.1117/12.3053444

Related papers

Magnetometry based on electromagnetically induced transparency

Alfred Meidinger

•Jun 1, 2000•0 citations

All-optical magnetometer based on electromagnetically induced transparency

Roland Lammegger, Arno Huss, Laurentius Windholz +1 more

We present an experimental module on electromagnetically induced transparency (EIT) in a Hanle configuration aimed to application for precise metrology. The EIT line width of the order of hundred hertz equivalent to nano-Tesla magnetic flux density has been achieved in rubidium atomic vapors with Ne buffer gases at room temperature. It can be interest for build of EIT based all-optical compact magnetometers, competitive to the most sensitive magnetometers based on superconducting quantum interference devices.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 2, 2004•2 citations

Stable vector magnetometers based on electromagnetically induced transparency (EIT)

Ying-Ju Wang

Magnetic sensors are widely used in many applications including medical diagnostics, geomagnetic survey, etc. Scalar atomic magnetometers that have demonstrated sensitivity at and below fT/ Hz^1/2 level can be adapted to include measurement of magnetic field orientation but usually at the cost of accuracy and with limitation of dynamic range. Magnetometry using electromagnetically induced transparency (EIT) instead was used to provide both scalar accuracy and vector information with angle resolution at a level of 10-3 deg/Hz^1/2. We present a scheme for EIT vector magnetic field measurement with the common-mode drift suppression by probing multiple EIT resonances. The demonstrated sensitivity is stable to < 200 pT/ Hz^1/2 at 1 mHz.

Optical and Quantum Sensing and Precision Metrology II•Mar 13, 2024•0 citations

Magnetic field measurements based on Electromagnetically Induced Transparency

Arno Huss, Roland Lammegger, Laurentius Windholz

•Jan 1, 2003•0 citations

Experimental Investigation on a Highly Sensitive Atomic Magnetometer

李曙光, 徐云飞, 王兆英 +2 more

Chinese Physics Letters•Jan 1, 2009•1 citation

Vector magnetometry based on electromagnetically induced transparency in linearly polarized light

Valeriy I. Yudin, А. В. Тайченачев, Yaroslav O. Dudin +3 more

We develop a generalized principle of electromagnetically induced transparency (EIT) vector magnetometry based on high-contrast EIT resonances and the symmetry of atom-light interaction in the linearly polarized bichromatic fields. Operation of such vector magnetometer on the ${D}_{1}$ line of $^{87}\mathrm{Rb}$ has been demonstrated. The proposed compass-magnetometer has an increased immunity to shifts produced by quadratic Zeeman and ac-Stark effects, as well as by atom-buffer gas and atom-atom collisions. In our proof-of-principle experiment the detected angular sensitivity to magnetic field orientation is ${10}^{\ensuremath{-}3}$ deg/Hz${}^{1/2}$, which is limited by laser intensity fluctuations, light polarization quality, and magnitude of the magnetic field.

Physical Review A•Sep 13, 2010•111 citations
We present an experimental module on electromagnetically induced transparency (EIT) in a Hanle configuration aimed to application for precise metrology. The EIT line width of the order of hundred hertz equivalent to nano-Tesla magnetic flux density has been achieved in rubidium atomic vapors with Ne buffer gases at room temperature. It can be interest for build of EIT based all-optical compact magnetometers, competitive to the most sensitive magnetometers based on superconducting quantum interference devices.
Magnetic sensors are widely used in many applications including medical diagnostics, geomagnetic survey, etc. Scalar atomic magnetometers that have demonstrated sensitivity at and below fT/ Hz^1/2 level can be adapted to include measurement of magnetic field orientation but usually at the cost of accuracy and with limitation of dynamic range. Magnetometry using electromagnetically induced transparency (EIT) instead was used to provide both scalar accuracy and vector information with angle resolution at a level of 10-3 deg/Hz^1/2. We present a scheme for EIT vector magnetic field measurement with the common-mode drift suppression by probing multiple EIT resonances. The demonstrated sensitivity is stable to < 200 pT/ Hz^1/2 at 1 mHz.
We develop a generalized principle of electromagnetically induced transparency (EIT) vector magnetometry based on high-contrast EIT resonances and the symmetry of atom-light interaction in the linearly polarized bichromatic fields. Operation of such vector magnetometer on the D1{D}_{1}D1​ line of 87Rb^{87}\mathrm{Rb}87Rb has been demonstrated. The proposed compass-magnetometer has an increased immunity to shifts produced by quadratic Zeeman and ac-Stark effects, as well as by atom-buffer gas and atom-atom collisions. In our proof-of-principle experiment the detected angular sensitivity to magnetic field orientation is ${10}^{\ensuremath{-}3}$ deg/Hz1/2{}^{1/2}1/2, which is limited by laser intensity fluctuations, light polarization quality, and magnitude of the magnetic field.