Optical and Quantum Sensing and Precision Metrology II

Stable vector magnetometers based on electromagnetically induced transparency (EIT)

Ying-Ju Wang

Published Mar 13, 2024• 0 citations
Publisher

Abstract

Magnetic sensors are widely used in many applications including medical diagnostics, geomagnetic survey, etc. Scalar atomic magnetometers that have demonstrated sensitivity at and below fT/ Hz^1/2 level can be adapted to include measurement of magnetic field orientation but usually at the cost of accuracy and with limitation of dynamic range. Magnetometry using electromagnetically induced transparency (EIT) instead was used to provide both scalar accuracy and vector information with angle resolution at a level of 10-3 deg/Hz^1/2. We present a scheme for EIT vector magnetic field measurement with the common-mode drift suppression by probing multiple EIT resonances. The demonstrated sensitivity is stable to < 200 pT/ Hz^1/2 at 1 mHz.

DOI
10.1117/12.3011714

Related papers

Sensitivity of a vector atomic magnetometer based on electromagnetically induced transparency

Irina V. Novikova, Eugeniy E. Mikhailov, John E. Kitching +8 more

We present a realization of a magnetic sensor based on electromagnetically induced transparency (EIT) resonances observed in hot Rb vapor using lin$\parallel$lin polarized dichromatic light and evaluate scalar and vector capabilities of the sensor for measuring Earth-like magnetic fields. We demonstrate scalar measurement sensitivity of 2 pT/Hz^1/2 in the 1-100~Hz spectral frequency band using a cm^3 Rb vapor cell, significantly improving the performance for such a configuration if compared with earlier measurements of large magnetic fields. By using a single linearly polarized dichromatic optical field, we are also able to determine the direction of the magnetic field with respect to the light propagation direction and polarization, taking advantage of the symmetries of the interaction scheme. We accomplish that by combining the polarization-sensitive transmission measurements and sparse sensing machine learning techniques. A path for further improvement of the sensitivity and elimination of systematic effects, such as heading error, is discussed.

•May 6, 2024•0 citations

Sensitivity of a vector atomic magnetometer based on electromagnetically induced transparency

Irina V. Novikova, Eugeniy E. Mikhailov, John E. Kitching +8 more

We present a realization of a magnetic sensor based on electromagnetically induced transparency (EIT) resonances observed in hot Rb vapor using lin$\parallel$lin polarized dichromatic light and evaluate scalar and vector capabilities of the sensor for measuring Earth-like magnetic fields. We demonstrate scalar measurement sensitivity of 2 pT/Hz^1/2 in the 1-100~Hz spectral frequency band using a cm^3 Rb vapor cell, significantly improving the performance for such a configuration if compared with earlier measurements of large magnetic fields. By using a single linearly polarized dichromatic optical field, we are also able to determine the direction of the magnetic field with respect to the light propagation direction and polarization, taking advantage of the symmetries of the interaction scheme. We accomplish that by combining the polarization-sensitive transmission measurements and sparse sensing machine learning techniques. A path for further improvement of the sensitivity and elimination of systematic effects, such as heading error, is discussed.

•Jun 14, 2024•0 citations

Optimization of an electromagnetically induced transparency (EIT)-based vector atomic magnetometer

Mario Alberto González Maldonado, Chester Zimmerman, Owen Rollins +8 more

We optimize various experimental parameters to improve the sensitivity of magnetic field measurements based on lin||lin EIT resonances. We achieve scalar magne-tometer sensitivity <3pT/Hz in a 100 mm3 vapor cell and demonstrated vector measurements capabilities.

Conference on Lasers and Electro-Optics•Jan 1, 2024•0 citations

Vector magnetometry based on electromagnetically induced transparency in linearly polarized light

Valeriy I. Yudin, А. В. Тайченачев, Yaroslav O. Dudin +3 more

We develop a generalized principle of electromagnetically induced transparency (EIT) vector magnetometry based on high-contrast EIT resonances and the symmetry of atom-light interaction in the linearly polarized bichromatic fields. Operation of such vector magnetometer on the ${D}_{1}$ line of $^{87}\mathrm{Rb}$ has been demonstrated. The proposed compass-magnetometer has an increased immunity to shifts produced by quadratic Zeeman and ac-Stark effects, as well as by atom-buffer gas and atom-atom collisions. In our proof-of-principle experiment the detected angular sensitivity to magnetic field orientation is ${10}^{\ensuremath{-}3}$ deg/Hz${}^{1/2}$, which is limited by laser intensity fluctuations, light polarization quality, and magnitude of the magnetic field.

arXiv:1004.3969•Physical Review A•Sep 13, 2010•118 citations

Sensitivity of a vector atomic magnetometer based on electromagnetically induced transparency

Mario Alberto González Maldonado, Owen Rollins, Alex Toyryla +8 more

We present a realization of a magnetic sensor based on electromagnetically induced transparency (EIT) resonances observed in hot Rb vapor using lin∥lin polarized dichromatic light and evaluate scalar and vector capabilities of the sensor for measuring Earth-like magnetic fields. We demonstrate scalar measurement sensitivity of 2pT/Hz in the 1–100 Hz spectral frequency band using a ~1 cm 3 Rb vapor cell, significantly improving the performance for such a configuration if compared with earlier measurements of large magnetic fields. By using a single linearly polarized dichromatic optical field, we are also able to determine the direction of the magnetic field with respect to the light propagation direction and polarization, taking advantage of the symmetries of the interaction scheme. We accomplish that by combining the polarization-sensitive transmission measurements and sparse sensing machine learning techniques. A path for further improvement of the sensitivity and elimination of systematic effects, such as heading errors, is discussed.

Optics Express•Jun 26, 2024•19 citations

Pulsed vector atomic magnetometer using an alternating fast-rotating field

Tao Wang, Wonjae Lee, Mark E. Limes +3 more

We introduce a vector atomic magnetometer that employs a fast-rotating magnetic field applied to a pulsed 87Rb scalar atomic magnetometer. This approach enables simultaneous measurements of the total magnetic field and its two polar angles relative to the rotation plane. Operating in gradiometer mode, the magnetometer achieves a total field gradient sensitivity of 35 $${{{\rm{fT}}}}/\sqrt{{{{\rm{Hz}}}}}$$ fT / Hz (0.7 parts per billion) and angular resolutions of 6 $${{{\rm{nrad}}}}/\sqrt{{{{\rm{Hz}}}}}$$ nrad / Hz at a 50 μT Earth field strength. The noise spectra remain flat down to 1 Hz and 0.1 Hz, respectively. Here we show that this method overcomes several metrological challenges commonly faced by vector magnetometers and gradiometers. We propose a unique peak-altering modulation technique to mitigate systematic effects, including a newly identified dynamic heading error. Additionally, we establish the fundamental sensitivity limits of the sensor, demonstrating that its vector sensitivity approaches scalar sensitivity while preserving the inherent accuracy and calibration benefits of scalar sensors. This high-dynamic-range, ultrahigh-resolution magnetometer offers exceptional versatility for diverse applications.

arXiv:2304.00214•Nature Communications•Feb 5, 2025•39 citations
Magnetic sensors are widely used in many applications including medical diagnostics, geomagnetic survey, etc. Scalar atomic magnetometers that have demonstrated sensitivity at and below fT/ Hz^1/2 level can be adapted to include measurement of magnetic field orientation but usually at the cost of accuracy and with limitation of dynamic range. Magnetometry using electromagnetically induced transparency (EIT) instead was used to provide both scalar accuracy and vector information with angle resolution at a level of 10-3 deg/Hz^1/2. We present a scheme for EIT vector magnetic field measurement with the common-mode drift suppression by probing multiple EIT resonances. The demonstrated sensitivity is stable to < 200 pT/ Hz^1/2 at 1 mHz.
We present a realization of a magnetic sensor based on electromagnetically induced transparency (EIT) resonances observed in hot Rb vapor using lin∥\parallel∥lin polarized dichromatic light and evaluate scalar and vector capabilities of the sensor for measuring Earth-like magnetic fields. We demonstrate scalar measurement sensitivity of 2 pT/Hz^1/2 in the 1-100~Hz spectral frequency band using a cm^3 Rb vapor cell, significantly improving the performance for such a configuration if compared with earlier measurements of large magnetic fields. By using a single linearly polarized dichromatic optical field, we are also able to determine the direction of the magnetic field with respect to the light propagation direction and polarization, taking advantage of the symmetries of the interaction scheme. We accomplish that by combining the polarization-sensitive transmission measurements and sparse sensing machine learning techniques. A path for further improvement of the sensitivity and elimination of systematic effects, such as heading error, is discussed.
We present a realization of a magnetic sensor based on electromagnetically induced transparency (EIT) resonances observed in hot Rb vapor using lin∥\parallel∥lin polarized dichromatic light and evaluate scalar and vector capabilities of the sensor for measuring Earth-like magnetic fields. We demonstrate scalar measurement sensitivity of 2 pT/Hz^1/2 in the 1-100~Hz spectral frequency band using a cm^3 Rb vapor cell, significantly improving the performance for such a configuration if compared with earlier measurements of large magnetic fields. By using a single linearly polarized dichromatic optical field, we are also able to determine the direction of the magnetic field with respect to the light propagation direction and polarization, taking advantage of the symmetries of the interaction scheme. We accomplish that by combining the polarization-sensitive transmission measurements and sparse sensing machine learning techniques. A path for further improvement of the sensitivity and elimination of systematic effects, such as heading error, is discussed.
We develop a generalized principle of electromagnetically induced transparency (EIT) vector magnetometry based on high-contrast EIT resonances and the symmetry of atom-light interaction in the linearly polarized bichromatic fields. Operation of such vector magnetometer on the D1{D}_{1}D1​ line of 87Rb^{87}\mathrm{Rb}87Rb has been demonstrated. The proposed compass-magnetometer has an increased immunity to shifts produced by quadratic Zeeman and ac-Stark effects, as well as by atom-buffer gas and atom-atom collisions. In our proof-of-principle experiment the detected angular sensitivity to magnetic field orientation is ${10}^{\ensuremath{-}3}$ deg/Hz1/2{}^{1/2}1/2, which is limited by laser intensity fluctuations, light polarization quality, and magnitude of the magnetic field.
We present a realization of a magnetic sensor based on electromagnetically induced transparency (EIT) resonances observed in hot Rb vapor using lin∥lin polarized dichromatic light and evaluate scalar and vector capabilities of the sensor for measuring Earth-like magnetic fields. We demonstrate scalar measurement sensitivity of 2pT/Hz in the 1–100 Hz spectral frequency band using a ~1 cm 3 Rb vapor cell, significantly improving the performance for such a configuration if compared with earlier measurements of large magnetic fields. By using a single linearly polarized dichromatic optical field, we are also able to determine the direction of the magnetic field with respect to the light propagation direction and polarization, taking advantage of the symmetries of the interaction scheme. We accomplish that by combining the polarization-sensitive transmission measurements and sparse sensing machine learning techniques. A path for further improvement of the sensitivity and elimination of systematic effects, such as heading errors, is discussed.
We introduce a vector atomic magnetometer that employs a fast-rotating magnetic field applied to a pulsed 87Rb scalar atomic magnetometer. This approach enables simultaneous measurements of the total magnetic field and its two polar angles relative to the rotation plane. Operating in gradiometer mode, the magnetometer achieves a total field gradient sensitivity of 35 fT/Hz{{{\rm{fT}}}}/\sqrt{{{{\rm{Hz}}}}}fT/Hz​ fT / Hz (0.7 parts per billion) and angular resolutions of 6 nrad/Hz{{{\rm{nrad}}}}/\sqrt{{{{\rm{Hz}}}}}nrad/Hz​ nrad / Hz at a 50 μT Earth field strength. The noise spectra remain flat down to 1 Hz and 0.1 Hz, respectively. Here we show that this method overcomes several metrological challenges commonly faced by vector magnetometers and gradiometers. We propose a unique peak-altering modulation technique to mitigate systematic effects, including a newly identified dynamic heading error. Additionally, we establish the fundamental sensitivity limits of the sensor, demonstrating that its vector sensitivity approaches scalar sensitivity while preserving the inherent accuracy and calibration benefits of scalar sensors. This high-dynamic-range, ultrahigh-resolution magnetometer offers exceptional versatility for diverse applications.