Physical Review A

Vector magnetometry based on electromagnetically induced transparency in linearly polarized light

Valeriy I. Yudin, А. В. Тайченачев, Yaroslav O. Dudin, Vladimir L Velichansky, Alexander S. Zibrov, Sergei A. Zibrov

Published Sep 13, 2010• 111 citations
Publisher

Abstract

We develop a generalized principle of electromagnetically induced transparency (EIT) vector magnetometry based on high-contrast EIT resonances and the symmetry of atom-light interaction in the linearly polarized bichromatic fields. Operation of such vector magnetometer on the ${D}_{1}$ line of $^{87}\mathrm{Rb}$ has been demonstrated. The proposed compass-magnetometer has an increased immunity to shifts produced by quadratic Zeeman and ac-Stark effects, as well as by atom-buffer gas and atom-atom collisions. In our proof-of-principle experiment the detected angular sensitivity to magnetic field orientation is ${10}^{\ensuremath{-}3}$ deg/Hz${}^{1/2}$, which is limited by laser intensity fluctuations, light polarization quality, and magnitude of the magnetic field.

DOI
10.1103/physreva.82.033807

Related papers

EIT-based Vector Magnetometry in Linear Polarized Light

Valeriy I. Yudin, A. V. Taǐchenachev, Yuri Dudin +3 more

We develop a generalized principle of EIT vector magnetometry based on high-contrast EIT-resonances and the symmetry of atom-light interaction in the linearly polarized bichromatic fields. Operation of such vector magnetometer on the D1 line of 87Rb has been demonstrated. The proposed compass-magnetometer has an increased immunity to shifts produced by quadratic Zeeman and ac-Stark effects, as well as by atom-buffer gas and atom-atom collisions. In our proof-of-principle experiment the detected sensitivity to magnetic field orientation is 10^{-3} deg/Hz^{1/2}, which is limited by laser intensity fluctuations, light polarization quality, and the magnitude of the magnetic field.

arXiv:1004.3969•Apr 22, 2010•0 citations

Measurements of the magnetic field vector using multiple electromagnetically induced transparency resonances in Rb vapor

Kevin C. Cox, Valeriy I. Yudin, А. В. Тайченачев +2 more

We study the dependence of electromagnetically induced transparency (EIT) resonance amplitudes on the external magnetic field direction in a linearly polarized bichromatic light ($\mathit{lin}||\mathit{lin}$) configuration in $^{87}\mathrm{Rb}$ vapor. We demonstrate that all seven resolvable EIT resonances exhibit maxima or minima at certain orientations of the laser polarization relative to the wave vector and magnetic field. This effect can be used for the development of a high-precision EIT vector magnetometer.

arXiv:1011.0503•Physical Review A•Jan 14, 2011•94 citations

Sensitivity of a vector atomic magnetometer based on electromagnetically induced transparency

Mario Alberto González Maldonado, Owen Rollins, Alex Toyryla +8 more

We present a realization of a magnetic sensor based on electromagnetically induced transparency (EIT) resonances observed in hot Rb vapor using lin$\parallel$lin polarized dichromatic light and evaluate scalar and vector capabilities of the sensor for measuring Earth-like magnetic fields. We demonstrate scalar measurement sensitivity of 2 pT/Hz^1/2 in the 1-100~Hz spectral frequency band using a cm^3 Rb vapor cell, significantly improving the performance for such a configuration if compared with earlier measurements of large magnetic fields. By using a single linearly polarized dichromatic optical field, we are also able to determine the direction of the magnetic field with respect to the light propagation direction and polarization, taking advantage of the symmetries of the interaction scheme. We accomplish that by combining the polarization-sensitive transmission measurements and sparse sensing machine learning techniques. A path for further improvement of the sensitivity and elimination of systematic effects, such as heading error, is discussed.

Optics Express•Jun 12, 2024•14 citations

Sensitivity of a vector atomic magnetometer based on electromagnetically induced transparency

Irina V. Novikova, Eugeniy E. Mikhailov, John E. Kitching +8 more

We present a realization of a magnetic sensor based on electromagnetically induced transparency (EIT) resonances observed in hot Rb vapor using lin$\parallel$lin polarized dichromatic light and evaluate scalar and vector capabilities of the sensor for measuring Earth-like magnetic fields. We demonstrate scalar measurement sensitivity of 2 pT/Hz^1/2 in the 1-100~Hz spectral frequency band using a cm^3 Rb vapor cell, significantly improving the performance for such a configuration if compared with earlier measurements of large magnetic fields. By using a single linearly polarized dichromatic optical field, we are also able to determine the direction of the magnetic field with respect to the light propagation direction and polarization, taking advantage of the symmetries of the interaction scheme. We accomplish that by combining the polarization-sensitive transmission measurements and sparse sensing machine learning techniques. A path for further improvement of the sensitivity and elimination of systematic effects, such as heading error, is discussed.

•Jun 14, 2024•0 citations

On the Development of an Optical Rubidium Vector Atomic Magnetometer

James McKelvy, Irina V. Novikova, Eugeniy E. Mikhailov +6 more

The precise measurement of magnetic fields is a fundamental tool of remote sensing. However, accurately measuring the direction of magnetic fields is challenging with atomic magnetometers. In this work, we discuss progress on the development of an all-optical vector atomic magnetometer that uses electromagnetically induced transparency (EIT) on87Rb vapor. The magnitude of the magnetic field is evaluated by measuring the separation of the laser transmission peaks of the Zeeman-resolved EIT spectra, and the direction is measured by evaluating the relative peak contrast using a lightweight machine learning algorithm involving principal component analysis (PCA). We have demonstrated a scalar sensitivity of $ < 10pT/\sqrt {Hz} $ in the 1–100 Hz band and an angular accuracy of < 1°. This approach for vector magnetometry does not require an array of sensors or calibration coils, ultimately setting the groundwork for the design of a new magnetometer that is lighter and more accurate than conventional vector magnetometer configurations.

IEEE International Geoscience and Remote Sensing Symposium (IGARSS)•Jul 16, 2023•2 citations

Vector magnetometry using electromagnetically induced transparency with $lin\perp lin$ polarization

Bankim Chandra Das, Arpita Das, Dipankar Bhattacharyya +1 more

Vector magnetometry was studied using the electromagnetically induced transparency (EIT) with linear $\perp$ linear ($lin \perp lin$) polarization of the probe and the pump beams in $^{87}Rb$ - $D_2$ transition. The dependence of the EIT on the direction of the quantization axis and the relative orientation of the polarization of the applied electric fields was studied experimentally. We have shown that from the relative strengths of the $σ$ and $π$ EIT peaks, the direction of the magnetic field can be found. Moreover from the relative separation between the $σ$ and $π$ EIT peaks, the strengths of the magnetic field can be calculated. We have also demonstrated that the EIT peak amplitudes show oscillatory behaviour depending upon the orientation of the laser polarization relative to the magnetic field direction. Using the positions of the maxima and minima, the direction of the magnetic field can be calculated. To understand the experimental observation, a theoretical study has been done numerically considering all the thirteen Zeeman sub-levels. Apart from the numerical model, a toy model has also been considered to obtain an analytical response of the medium considering the velocity distribution. The dependencies of the magnetic field direction and the polarization direction of the electric fields have been explicitly derived in the analytical model. Further the direction of the magnetic field is calculated using the analytical solution. This study can be helpful in order to make an EIT based atomic vector magnetometer at room temperature.

arXiv:1907.00756•Jul 1, 2019•0 citations
We develop a generalized principle of electromagnetically induced transparency (EIT) vector magnetometry based on high-contrast EIT resonances and the symmetry of atom-light interaction in the linearly polarized bichromatic fields. Operation of such vector magnetometer on the D1{D}_{1}D1​ line of 87Rb^{87}\mathrm{Rb}87Rb has been demonstrated. The proposed compass-magnetometer has an increased immunity to shifts produced by quadratic Zeeman and ac-Stark effects, as well as by atom-buffer gas and atom-atom collisions. In our proof-of-principle experiment the detected angular sensitivity to magnetic field orientation is 10\ensuremath−3{10}^{\ensuremath{-}3}10\ensuremath−3 deg/Hz1/2{}^{1/2}1/2, which is limited by laser intensity fluctuations, light polarization quality, and magnitude of the magnetic field.
We develop a generalized principle of EIT vector magnetometry based on high-contrast EIT-resonances and the symmetry of atom-light interaction in the linearly polarized bichromatic fields. Operation of such vector magnetometer on the D1 line of 87Rb has been demonstrated. The proposed compass-magnetometer has an increased immunity to shifts produced by quadratic Zeeman and ac-Stark effects, as well as by atom-buffer gas and atom-atom collisions. In our proof-of-principle experiment the detected sensitivity to magnetic field orientation is 10^{-3} deg/Hz^{1/2}, which is limited by laser intensity fluctuations, light polarization quality, and the magnitude of the magnetic field.
We study the dependence of electromagnetically induced transparency (EIT) resonance amplitudes on the external magnetic field direction in a linearly polarized bichromatic light (lin∣∣lin\mathit{lin}||\mathit{lin}lin∣∣lin) configuration in 87Rb^{87}\mathrm{Rb}87Rb vapor. We demonstrate that all seven resolvable EIT resonances exhibit maxima or minima at certain orientations of the laser polarization relative to the wave vector and magnetic field. This effect can be used for the development of a high-precision EIT vector magnetometer.
We present a realization of a magnetic sensor based on electromagnetically induced transparency (EIT) resonances observed in hot Rb vapor using lin∥\parallel∥lin polarized dichromatic light and evaluate scalar and vector capabilities of the sensor for measuring Earth-like magnetic fields. We demonstrate scalar measurement sensitivity of 2 pT/Hz^1/2 in the 1-100~Hz spectral frequency band using a cm^3 Rb vapor cell, significantly improving the performance for such a configuration if compared with earlier measurements of large magnetic fields. By using a single linearly polarized dichromatic optical field, we are also able to determine the direction of the magnetic field with respect to the light propagation direction and polarization, taking advantage of the symmetries of the interaction scheme. We accomplish that by combining the polarization-sensitive transmission measurements and sparse sensing machine learning techniques. A path for further improvement of the sensitivity and elimination of systematic effects, such as heading error, is discussed.
We present a realization of a magnetic sensor based on electromagnetically induced transparency (EIT) resonances observed in hot Rb vapor using lin∥\parallel∥lin polarized dichromatic light and evaluate scalar and vector capabilities of the sensor for measuring Earth-like magnetic fields. We demonstrate scalar measurement sensitivity of 2 pT/Hz^1/2 in the 1-100~Hz spectral frequency band using a cm^3 Rb vapor cell, significantly improving the performance for such a configuration if compared with earlier measurements of large magnetic fields. By using a single linearly polarized dichromatic optical field, we are also able to determine the direction of the magnetic field with respect to the light propagation direction and polarization, taking advantage of the symmetries of the interaction scheme. We accomplish that by combining the polarization-sensitive transmission measurements and sparse sensing machine learning techniques. A path for further improvement of the sensitivity and elimination of systematic effects, such as heading error, is discussed.
The precise measurement of magnetic fields is a fundamental tool of remote sensing. However, accurately measuring the direction of magnetic fields is challenging with atomic magnetometers. In this work, we discuss progress on the development of an all-optical vector atomic magnetometer that uses electromagnetically induced transparency (EIT) on87Rb vapor. The magnitude of the magnetic field is evaluated by measuring the separation of the laser transmission peaks of the Zeeman-resolved EIT spectra, and the direction is measured by evaluating the relative peak contrast using a lightweight machine learning algorithm involving principal component analysis (PCA). We have demonstrated a scalar sensitivity of $ < 10pT/\sqrt {Hz} $ in the 1–100 Hz band and an angular accuracy of < 1°. This approach for vector magnetometry does not require an array of sensors or calibration coils, ultimately setting the groundwork for the design of a new magnetometer that is lighter and more accurate than conventional vector magnetometer configurations.
Vector magnetometry using electromagnetically induced transparency with lin⊥linlin\perp linlin⊥lin polarization
Vector magnetometry was studied using the electromagnetically induced transparency (EIT) with linear ⊥\perp⊥ linear (lin⊥linlin \perp linlin⊥lin) polarization of the probe and the pump beams in 87Rb^{87}Rb87Rb - D2D_2D2​ transition. The dependence of the EIT on the direction of the quantization axis and the relative orientation of the polarization of the applied electric fields was studied experimentally. We have shown that from the relative strengths of the σσσ and πππ EIT peaks, the direction of the magnetic field can be found. Moreover from the relative separation between the σσσ and πππ EIT peaks, the strengths of the magnetic field can be calculated. We have also demonstrated that the EIT peak amplitudes show oscillatory behaviour depending upon the orientation of the laser polarization relative to the magnetic field direction. Using the positions of the maxima and minima, the direction of the magnetic field can be calculated. To understand the experimental observation, a theoretical study has been done numerically considering all the thirteen Zeeman sub-levels. Apart from the numerical model, a toy model has also been considered to obtain an analytical response of the medium considering the velocity distribution. The dependencies of the magnetic field direction and the polarization direction of the electric fields have been explicitly derived in the analytical model. Further the direction of the magnetic field is calculated using the analytical solution. This study can be helpful in order to make an EIT based atomic vector magnetometer at room temperature.