Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE

All-optical magnetometer based on electromagnetically induced transparency

Roland Lammegger, Arno Huss, Laurentius Windholz, Ji-Hua Xu

Published Aug 2, 2004• 2 citations
Publisher

Abstract

We present an experimental module on electromagnetically induced transparency (EIT) in a Hanle configuration aimed to application for precise metrology. The EIT line width of the order of hundred hertz equivalent to nano-Tesla magnetic flux density has been achieved in rubidium atomic vapors with Ne buffer gases at room temperature. It can be interest for build of EIT based all-optical compact magnetometers, competitive to the most sensitive magnetometers based on superconducting quantum interference devices.

DOI
10.1117/12.560595

Related papers

A magnetometer based on quantum interference effects

Roland Lammegger, Stefan Hatzl, Arno Huss +1 more

We have investigated some possibilities to use effect of Electromagnetically Induced Transparency (EIT), which is based on quantum interference, for measuring magnetic fields. Multi-frequency laser light is driving atomic transitions (e.g. in a Λ-type excitation scheme), and the atoms are decaying into a super positional dark state, in which the population is trapped, if the frequencies of the applied light fulfills certain conditions. Then the atomic medium becomes transparent for the exciting electromagnetic fields. The observed line width of this "transparency window" is not limited by the natural line width of the involved optical transitions and can be decreased down to a few hundredths of Hertz. As a consequence, this narrow feature can be used as a sensitive probe if the frequencies fulfill the required conditions, which are dependent on the energy positions of the involved atomic levels. These energy positions are influenced by external magnetic fields, thus the observation of EIT can be used to determine external magnetic fields strengths. In our approach a so called Hanle-configuration is used, where only one laser frequency is used to simultaneously excite σ+- and σ--transitions within a single hyperfine transition of the Rb87 Dl-line. In this configuration a resonant Λ-system is formed at zero magnetic field. The detuning from two-photon resonance is caused by a magnetic field scanned in laser propagation direction. Any additional probe magnetic field characteristically changes the width and shape of the EIT transparency window resonance; hence the probe magnetic field can be determined directly from the shape of this resonance.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 22, 2005•2 citations

On the Development of an Optical Rubidium Vector Atomic Magnetometer

James McKelvy, Irina V. Novikova, Eugeniy E. Mikhailov +6 more

The precise measurement of magnetic fields is a fundamental tool of remote sensing. However, accurately measuring the direction of magnetic fields is challenging with atomic magnetometers. In this work, we discuss progress on the development of an all-optical vector atomic magnetometer that uses electromagnetically induced transparency (EIT) on87Rb vapor. The magnitude of the magnetic field is evaluated by measuring the separation of the laser transmission peaks of the Zeeman-resolved EIT spectra, and the direction is measured by evaluating the relative peak contrast using a lightweight machine learning algorithm involving principal component analysis (PCA). We have demonstrated a scalar sensitivity of $ < 10pT/\sqrt {Hz} $ in the 1–100 Hz band and an angular accuracy of < 1°. This approach for vector magnetometry does not require an array of sensors or calibration coils, ultimately setting the groundwork for the design of a new magnetometer that is lighter and more accurate than conventional vector magnetometer configurations.

IEEE International Geoscience and Remote Sensing Symposium (IGARSS)•Jul 16, 2023•2 citations

Nonlinear properties of electromagnetically induced transparency in rubidium vapor

Dmitry Strekalov, Andrey B. Matsko, Lute Maleki

Nonlinear properties of electromagnetically induced transparency (EIT) with respect to a weak probe light are studied. We observe EIT in a rubidium vapor, measure the slow light group velocity and the EIT resonance width, and find that those parameters show a strong dependence on the probe power. We theoretically study the influence of the EIT probe dependence on the performance of the EIT-based optical delay lines and magnetometers.

Journal of the Optical Society of America B•Jan 1, 2005•12 citations

Vector atomic magnetometer based on EIT in Rb vapor

Irina V. Novikova, Eugeniy E. Mikhailov, Alex Toyryla +6 more

By analyzing the relative frequencies and amplitude of multiple electromagnetically induced transparency resonances in external magnetic field, we achieve scalar magnetometer sensitivity <5pT/Hz, and can determine the B-field direction with angular sensitivity < 1° using machine learning and optical lock techniques in a 100 mm3 atomic vapor cell.

•Jan 1, 2023•2 citations

A Review of Ground State Hanle Effect on Paraffin Coated Alkali Atoms under EIT and EIA

Muhammad Jehanzaib Aslam, Muhammad Umar Farooq, Kishore Chand +2 more

Introduction This review is specifically aimed at providing deeper understanding of the ground state Hanle effect through novel methods of atomic vapor interaction with resonant light. Electromagnetically Induced Transparency (EIT) and absorption (EIA) are the primary phenomena in this context. EIT is a process in which destructive interference at absorption frequencies within a medium is caused by a control laser and makes the medium clear to the probe laser light. It should be noted that this transparency is crucial for turning on/off the light pulses, slowing down or stopping in several cases, thus enhancing the effectiveness of atomic magnetometers. However, constructive interference that occurs in EIA raises the density of the medium, which is advantageous for achieveing precise measurements. Thus, studying Hanle effect contribute in development of commercially valuable applications and the improvement of atomic clocks. Objective The objective of this study is to review the fundamental principles of the Hanle effect, EIT, EIA, and coating methods for alkali atoms. These principles and techniques are essential for improving the sensitivity and functionality of atomic magnetometers and other quantum devices. By understanding and applying these phenomena, significant progress has been made in the development of high-precision measurement tools and quantum technologies. Results Advancements in atomic magnetometer sensitivity represent a rapidly growing area of interest that has made the significant progress in the development of quantum devices. This review consolidates the state of art research and development of fundamental principles and practical applications of the Hanle effect, EIT, EIA, and coating methods for alkali atoms. It highlights how advancements in EIT and EIA have contributed to the sensitivity improvements of atomic magnetometers, and show the importance of coating methods for maintaining system integrity and performance. These developments are essential in revolutioning of modern quantum technologies and precision measurement devices.

Results in Optics•Oct 11, 2024•3 citations

Vector Magnetometer Using Rb Vapor

Kevin C. Cox

This project demonstrates an optical method for measuring the strength and\ndirection of a magnetic field using electromagnetically induced transparency\n(EIT) in rubidium vapor. In rubidium atoms, the Zeeman effect causes atomic\nstates to shift when an external magnetic field is applied. The magnitude of\nthese shifts, and consequently the strength of the magnetic field, can be measured\nby recording electromagnetically induced transparency resonances with\ntuned laser fields. Furthermore, since the atom's interaction with the laser field\nis dependent on the direction of the magnetic field and the laser polarization,\nwe are able to determine the direction as well as the strength of the magnetic\nfield by analyzing relative intensities of EIT resonances. With a feasible precision\ndown to 10 picoTesla and the possibility of complete field mapping, this\nmagnetometer can be useful for medical, geophysical, and materials testing\napplications.

•May 4, 2011•0 citations
We present an experimental module on electromagnetically induced transparency (EIT) in a Hanle configuration aimed to application for precise metrology. The EIT line width of the order of hundred hertz equivalent to nano-Tesla magnetic flux density has been achieved in rubidium atomic vapors with Ne buffer gases at room temperature. It can be interest for build of EIT based all-optical compact magnetometers, competitive to the most sensitive magnetometers based on superconducting quantum interference devices.
We have investigated some possibilities to use effect of Electromagnetically Induced Transparency (EIT), which is based on quantum interference, for measuring magnetic fields. Multi-frequency laser light is driving atomic transitions (e.g. in a Λ-type excitation scheme), and the atoms are decaying into a super positional dark state, in which the population is trapped, if the frequencies of the applied light fulfills certain conditions. Then the atomic medium becomes transparent for the exciting electromagnetic fields. The observed line width of this "transparency window" is not limited by the natural line width of the involved optical transitions and can be decreased down to a few hundredths of Hertz. As a consequence, this narrow feature can be used as a sensitive probe if the frequencies fulfill the required conditions, which are dependent on the energy positions of the involved atomic levels. These energy positions are influenced by external magnetic fields, thus the observation of EIT can be used to determine external magnetic fields strengths. In our approach a so called Hanle-configuration is used, where only one laser frequency is used to simultaneously excite σ+- and σ--transitions within a single hyperfine transition of the Rb87 Dl-line. In this configuration a resonant Λ-system is formed at zero magnetic field. The detuning from two-photon resonance is caused by a magnetic field scanned in laser propagation direction. Any additional probe magnetic field characteristically changes the width and shape of the EIT transparency window resonance; hence the probe magnetic field can be determined directly from the shape of this resonance.
The precise measurement of magnetic fields is a fundamental tool of remote sensing. However, accurately measuring the direction of magnetic fields is challenging with atomic magnetometers. In this work, we discuss progress on the development of an all-optical vector atomic magnetometer that uses electromagnetically induced transparency (EIT) on87Rb vapor. The magnitude of the magnetic field is evaluated by measuring the separation of the laser transmission peaks of the Zeeman-resolved EIT spectra, and the direction is measured by evaluating the relative peak contrast using a lightweight machine learning algorithm involving principal component analysis (PCA). We have demonstrated a scalar sensitivity of $ < 10pT/\sqrt {Hz} $ in the 1–100 Hz band and an angular accuracy of < 1°. This approach for vector magnetometry does not require an array of sensors or calibration coils, ultimately setting the groundwork for the design of a new magnetometer that is lighter and more accurate than conventional vector magnetometer configurations.
Introduction This review is specifically aimed at providing deeper understanding of the ground state Hanle effect through novel methods of atomic vapor interaction with resonant light. Electromagnetically Induced Transparency (EIT) and absorption (EIA) are the primary phenomena in this context. EIT is a process in which destructive interference at absorption frequencies within a medium is caused by a control laser and makes the medium clear to the probe laser light. It should be noted that this transparency is crucial for turning on/off the light pulses, slowing down or stopping in several cases, thus enhancing the effectiveness of atomic magnetometers. However, constructive interference that occurs in EIA raises the density of the medium, which is advantageous for achieveing precise measurements. Thus, studying Hanle effect contribute in development of commercially valuable applications and the improvement of atomic clocks. Objective The objective of this study is to review the fundamental principles of the Hanle effect, EIT, EIA, and coating methods for alkali atoms. These principles and techniques are essential for improving the sensitivity and functionality of atomic magnetometers and other quantum devices. By understanding and applying these phenomena, significant progress has been made in the development of high-precision measurement tools and quantum technologies. Results Advancements in atomic magnetometer sensitivity represent a rapidly growing area of interest that has made the significant progress in the development of quantum devices. This review consolidates the state of art research and development of fundamental principles and practical applications of the Hanle effect, EIT, EIA, and coating methods for alkali atoms. It highlights how advancements in EIT and EIA have contributed to the sensitivity improvements of atomic magnetometers, and show the importance of coating methods for maintaining system integrity and performance. These developments are essential in revolutioning of modern quantum technologies and precision measurement devices.
This project demonstrates an optical method for measuring the strength and\ndirection of a magnetic field using electromagnetically induced transparency\n(EIT) in rubidium vapor. In rubidium atoms, the Zeeman effect causes atomic\nstates to shift when an external magnetic field is applied. The magnitude of\nthese shifts, and consequently the strength of the magnetic field, can be measured\nby recording electromagnetically induced transparency resonances with\ntuned laser fields. Furthermore, since the atom's interaction with the laser field\nis dependent on the direction of the magnetic field and the laser polarization,\nwe are able to determine the direction as well as the strength of the magnetic\nfield by analyzing relative intensities of EIT resonances. With a feasible precision\ndown to 10 picoTesla and the possibility of complete field mapping, this\nmagnetometer can be useful for medical, geophysical, and materials testing\napplications.