Physical Review A

Real-time compensation scheme for the accurate measurement of the differential phase in a dual-atom-interferometer gyroscope

Ze-Xi Lu, Zhan-Wei Yao, Honghui Chen, Yin-Fei Mao, Si-Bin Lu, Min Jiang, Shao-Kang Li, Ke Min, Jie Gu, An-Qing Zhang, Runbing Li, Jin Wang, Mingsheng Zhan

Published Mar 10, 2025• 3 citations
Publisher

Abstract

A dual-atom-interferometer gyroscope has high sensitivity for accurate rotation measurements because of its immunity to common-mode noise. However, a measurement error is induced as the common phase noise, e.g., vibration noise, increases. In this work, we demonstrated a real-time compensation (RTC) scheme to improve the accuracy of measurements of the differential phase in dual atom interferometers. The vibration noise was measured by two seismometers and its induced phase shift was fed back to the Raman lasers after this shift was calculated based on the sensitivity function of the atom interferometers. After the RTC module was applied, the interference signals obtained via the square modulation method were stabilized at their midfringe points, which caused the vibration-induced phase noise for each of the atom interferometers to decrease from 495 mrad to 165 mrad. The differential phase error obtained by the dual atom interferometers and two seismometers was reduced from 114.8 mrad to 49.6 mrad, which implies that the rotation measurement error was improved by a factor of 2.3. This work paves the way to accurately measuring the rotation signal and has promising applications in fields of precision measurements.

DOI
10.1103/physreva.111.033305

Related papers

A dual-atom-interferometric gyroscope–accelerometer with simultaneous fringe locking

Huibin Yao, 岳旭光, Wenju Wei +9 more

Dual-atom-interferometer configurations are widely used in gyroscopes and gradiometers to suppress common-mode noise and extract inertial signals with high precision. However, phase coupling between the two interferometers arising from shared Raman laser fields poses a significant challenge to simultaneous fringe locking. Here, we demonstrate a dual-atom-interferometric gyroscope–accelerometer that simultaneously locks both interference fringes at their respective mid-fringe operating points using independent direct digital synthesizer (DDS) channels to control the Raman phase shifts of the two interferometers. The proposed dual-fringe-locking scheme independently stabilizes both interferometers while preserving the common-mode noise rejection inherent to the dual-interferometer configuration. Compared with conventional full-fringe scanning, the scheme enables simultaneous rotation-rate and acceleration measurements with a higher data rate and improved sensitivity in both channels. These results demonstrate the potential of dual-fringe locking for high-precision quantum inertial sensing.

Journal of Physics B Atomic Molecular and Optical Physics•Nov 12, 2026•0 citations

Restoring Velocity Immunity via Dynamic Mirror Compensation in a Large-Area Dual-Atom-Interferometer Gyroscope

Jie Gu, Yin-fei Mao, Zhan-Wei Yao +10 more

We propose and demonstrate a dynamical mirror compensation scheme to restore velocity immunity in a large-area dual-atom-interferometer gyroscope. In an ideal Mach-Zehnder configuration, the phase shift is inherently immune to atomic velocity, but this property is broken by the Earth's rotation via the Coriolis effect. We overcome this by actively rotating the Raman mirrors during the pulse sequence to cancel the time-dependent angular offset. The implementation relies on a decouplable calibration-compensation chain to remove rotation-induced time-dependent terms. The scheme is validated on a dual-atom-interferometer gyroscope with an interference area of 21.1 cm^2. After compensation, the phase's dependence on atomic velocity is reduced 40-fold, and the velocity contribution to scale-factor stability is evaluated to be 0.13 ppm. The sensor achieves a rotation sensitivity of 1.3\times10^{-8} rad/s/Hz^{1/2} and a stability of 1.9\times10^{-10} rad/s at 4500 s integration, together with a common-mode noise rejection ratio of up to 459, demonstrated in a seismic event. This work removes a key obstacle to scale-factor stabilization in atom-interferometer gyroscopes and paves the way for their applications in inertial navigation and geophysics.

physics.atom-phCross-listedarXiv:2605.29929•May 29, 2026•0 citations

Calibration of atomic trajectories in a large-area dual-atom-interferometer gyroscope

Zhan-Wei Yao, Si-Bin Lu, Runbing Li +3 more

We propose and demonstrate a method for calibrating atomic trajectories in a large-area dual-atom-interferometer gyroscope. The atom trajectories are monitored by modulating and delaying the Raman transition, and they are precisely calibrated by controlling the laser orientation and the bias magnetic field. To improve the immunity to the gravity effect and the common phase noise, the symmetry and the overlap of two large-area atomic interference loops are optimized by calibrating the atomic trajectories and by aligning the Raman-laser orientations. The dual-atom-interferometer gyroscope is applied in the measurement of the Earth's rotation. The sensitivity is $1.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}6}$ rad $\mathrm{s}{}^{\ensuremath{-}1}$ ${\text{Hz}}^{\ensuremath{-}1/2}$, and the long-term stability is $6.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}8}$ rad/s at 2000 s.

arXiv:1711.05872•Physical Review A•Jan 17, 2018•33 citations

High-performance gyroscope for rotational seismology.

Nathan Marliere, Mohamed Guessoum, Rémi Geiger +1 more

The Sagnac effect is at the heart of the modern precision inertial sensors. An interferometer with a physical area, when spun, exhibits a phase shift atits output. Measuring this phase-shift leads to a direct measurement of the rotation rate.The SYRTE dual-axis cold-atom gyroscope represents the state-of-art of atomic gyroscopes. With its large physical area (11cm2) and a long interrogation time of 800 ms, it offers both the sensitivity and stability 3 × 10^10 rad.s−1 to push the Sagnac measurement to an unprecedented accuracy level. Demonstrating such performance required the control and characterization of the experimental parameters and systematic effects and the precise knowledge of the scale factor. The cold-atom gyroscope experiment is based on atomic interferometry, where cooled Cesium-atoms (2μK) are launched vertically (∼ 5m/s) to be interrogated with a sequence of four Raman pulses (allowing an internal and external control over atomic states). The pulses play the role of atomic optics by splitting and guiding the matter-waves along the arms of the interferometer. By the end, transition probability measurement gives access to the phase-shift induced by rotation.I will present our recent work done to develop new methods that will improve the gyroscope sensitivity. The Double diffraction, atom diffraction inboth ±¯h⃗keff directions, should enables a measurement setup with no dead time based on the use of two correlated interleaved interferometers. Thus, the vibration and rotation noises that limits the sensitivity should average to achieve the detection noise, targeting the standard quantum projection noise.

•Sep 5, 2023•0 citations

Dual-atom-interferometric gyroscope with continuous cold atomic beams

Shengzhe Wang, Zhixin Meng, Peiqiang Yan +1 more

In closed-loop dual-atom interferometers, the initial phase shift is a non-inertial phase induced by Raman pulses. This initial optical phase affects the measurements of both acceleration and rotation rate. In this study, we present a method to modulate the initial optical phase of light pulse atom interferometers (LPAIs). Employing this modulation method, we investigated the influence of the initial optical phase on a closed-loop dual-atom interferometer. The results reveal a better short-term sensitivity in the rotation rate measurement at an initial optical phase of 0. Our closed-loop dual-atom interferometer allows for decoupled measurements of rotation rate and acceleration. With a short interrogation time of 2T = 1.73 ms, the short-term sensitivities of the rotation rate and acceleration measurements are 2.73 × 10 − 5 ( rad / s ) / Hz and 272 μ g / Hz , respectively.

Journal of Physics Conference Series•Nov 1, 2024•1 citation

Differential phase extraction in dual interferometers exploiting the correlation between classical and quantum sensors

Mehdi Langlois, Romain Caldani, Azer Trimeche +2 more

We perform the experimental demonstration of the method proposed earlier [F. P. Dos Santos, Phys. Rev. A 91, 063615 (2015)] to extract the differential phase in dual atom interferometers. From a single magneto-optical trap, we generate two atomic sources, vertically separated and free falling synchronously, with the help of an accelerated lattice. We drive simultaneous Raman interferometers onto the two sources and use the correlation with the vibration signal measured by a seismometer to extract the phase of each interferometer. We demonstrate an optimal sensitivity of the extracted differential phase between the two interferometers, free from vibration noise and limited by detection noise, when the two interferometers are in phase.

arXiv:1712.02071•Physical Review A•Nov 20, 2017•20 citations
A dual-atom-interferometer gyroscope has high sensitivity for accurate rotation measurements because of its immunity to common-mode noise. However, a measurement error is induced as the common phase noise, e.g., vibration noise, increases. In this work, we demonstrated a real-time compensation (RTC) scheme to improve the accuracy of measurements of the differential phase in dual atom interferometers. The vibration noise was measured by two seismometers and its induced phase shift was fed back to the Raman lasers after this shift was calculated based on the sensitivity function of the atom interferometers. After the RTC module was applied, the interference signals obtained via the square modulation method were stabilized at their midfringe points, which caused the vibration-induced phase noise for each of the atom interferometers to decrease from 495 mrad to 165 mrad. The differential phase error obtained by the dual atom interferometers and two seismometers was reduced from 114.8 mrad to 49.6 mrad, which implies that the rotation measurement error was improved by a factor of 2.3. This work paves the way to accurately measuring the rotation signal and has promising applications in fields of precision measurements.
Dual-atom-interferometer configurations are widely used in gyroscopes and gradiometers to suppress common-mode noise and extract inertial signals with high precision. However, phase coupling between the two interferometers arising from shared Raman laser fields poses a significant challenge to simultaneous fringe locking. Here, we demonstrate a dual-atom-interferometric gyroscope–accelerometer that simultaneously locks both interference fringes at their respective mid-fringe operating points using independent direct digital synthesizer (DDS) channels to control the Raman phase shifts of the two interferometers. The proposed dual-fringe-locking scheme independently stabilizes both interferometers while preserving the common-mode noise rejection inherent to the dual-interferometer configuration. Compared with conventional full-fringe scanning, the scheme enables simultaneous rotation-rate and acceleration measurements with a higher data rate and improved sensitivity in both channels. These results demonstrate the potential of dual-fringe locking for high-precision quantum inertial sensing.
We propose and demonstrate a dynamical mirror compensation scheme to restore velocity immunity in a large-area dual-atom-interferometer gyroscope. In an ideal Mach-Zehnder configuration, the phase shift is inherently immune to atomic velocity, but this property is broken by the Earth's rotation via the Coriolis effect. We overcome this by actively rotating the Raman mirrors during the pulse sequence to cancel the time-dependent angular offset. The implementation relies on a decouplable calibration-compensation chain to remove rotation-induced time-dependent terms. The scheme is validated on a dual-atom-interferometer gyroscope with an interference area of 21.1 cm^2. After compensation, the phase's dependence on atomic velocity is reduced 40-fold, and the velocity contribution to scale-factor stability is evaluated to be 0.13 ppm. The sensor achieves a rotation sensitivity of 1.3\times10^{-8} rad/s/Hz^{1/2} and a stability of 1.9\times10^{-10} rad/s at 4500 s integration, together with a common-mode noise rejection ratio of up to 459, demonstrated in a seismic event. This work removes a key obstacle to scale-factor stabilization in atom-interferometer gyroscopes and paves the way for their applications in inertial navigation and geophysics.
We propose and demonstrate a method for calibrating atomic trajectories in a large-area dual-atom-interferometer gyroscope. The atom trajectories are monitored by modulating and delaying the Raman transition, and they are precisely calibrated by controlling the laser orientation and the bias magnetic field. To improve the immunity to the gravity effect and the common phase noise, the symmetry and the overlap of two large-area atomic interference loops are optimized by calibrating the atomic trajectories and by aligning the Raman-laser orientations. The dual-atom-interferometer gyroscope is applied in the measurement of the Earth's rotation. The sensitivity is $1.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}6}$ rad $\mathrm{s}{}^{\ensuremath{-}1}$ ${\text{Hz}}^{\ensuremath{-}1/2}$, and the long-term stability is $6.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}8}$ rad/s at 2000 s.
The Sagnac effect is at the heart of the modern precision inertial sensors. An interferometer with a physical area, when spun, exhibits a phase shift atits output. Measuring this phase-shift leads to a direct measurement of the rotation rate.The SYRTE dual-axis cold-atom gyroscope represents the state-of-art of atomic gyroscopes. With its large physical area (11cm2) and a long interrogation time of 800 ms, it offers both the sensitivity and stability 3 × 10^10 rad.s−1 to push the Sagnac measurement to an unprecedented accuracy level. Demonstrating such performance required the control and characterization of the experimental parameters and systematic effects and the precise knowledge of the scale factor. The cold-atom gyroscope experiment is based on atomic interferometry, where cooled Cesium-atoms (2μK) are launched vertically (∼ 5m/s) to be interrogated with a sequence of four Raman pulses (allowing an internal and external control over atomic states). The pulses play the role of atomic optics by splitting and guiding the matter-waves along the arms of the interferometer. By the end, transition probability measurement gives access to the phase-shift induced by rotation.I will present our recent work done to develop new methods that will improve the gyroscope sensitivity. The Double diffraction, atom diffraction inboth ±¯h⃗keff directions, should enables a measurement setup with no dead time based on the use of two correlated interleaved interferometers. Thus, the vibration and rotation noises that limits the sensitivity should average to achieve the detection noise, targeting the standard quantum projection noise.
In closed-loop dual-atom interferometers, the initial phase shift is a non-inertial phase induced by Raman pulses. This initial optical phase affects the measurements of both acceleration and rotation rate. In this study, we present a method to modulate the initial optical phase of light pulse atom interferometers (LPAIs). Employing this modulation method, we investigated the influence of the initial optical phase on a closed-loop dual-atom interferometer. The results reveal a better short-term sensitivity in the rotation rate measurement at an initial optical phase of 0. Our closed-loop dual-atom interferometer allows for decoupled measurements of rotation rate and acceleration. With a short interrogation time of 2T = 1.73 ms, the short-term sensitivities of the rotation rate and acceleration measurements are 2.73 × 10 − 5 ( rad / s ) / Hz and 272 μ g / Hz , respectively.
We perform the experimental demonstration of the method proposed earlier [F. P. Dos Santos, Phys. Rev. A 91, 063615 (2015)] to extract the differential phase in dual atom interferometers. From a single magneto-optical trap, we generate two atomic sources, vertically separated and free falling synchronously, with the help of an accelerated lattice. We drive simultaneous Raman interferometers onto the two sources and use the correlation with the vibration signal measured by a seismometer to extract the phase of each interferometer. We demonstrate an optimal sensitivity of the extracted differential phase between the two interferometers, free from vibration noise and limited by detection noise, when the two interferometers are in phase.