具有时钟恢复和功率监测功能的时域平衡零拍探测器

郭旭波 Xu-bo GUO, 王旭阳 Xu-yang WANG, Yan-Xiang Jia, 张瑜 Yu ZHANG, 侯一卓 Yi-zhuo HOU, 李永民 yong-min LI

Published Jan 1, 2024• 0 citations
Publisher

Abstract

The time-domain balanced homodyne detector (TBHD) can be used to detect the quadratures of the pulsed optical signal directly, and it is a crucial component of the continuous variable quantum key distribution (CVQKD) system. At the receiver side of the CVQKD system, the recovery of clock signal and the monitoring of local oscillator (LO) power is realized using fiber optic couplers, photodetectors and power meters usually. The fiber optical couplers not only reduce the LO power but also introduce security vulnerability. To simplify the structure of the receiver side, reduce the cost and increase the security of CVQKD system, we design and experimentally realize a new type TBHD with clock recovery and power monitoring functions. The detector makes full use of the photoelectron current generated by the cascaded photodiode. It can not only measure the quadratures of the pulsed optical signal, but also monitor the LO power in real-time and generate the clock signal with the same frequency as the LO beam. In experiment, a common mode rejection ratio of 75 dB could be obtained, and a maximum signal-to-noise ratio of 13.50 dB could be measured at a repetition rate of 1 MHz. At the same time, the clock signals with the same frequency as the LO beam were generated, and the output voltage value scales with the LO power was measured. A good linear relationship between the output voltages and the LO powers was obtained. The fitting slope or gain is 2.52×10−7 V/photon, and the sum of residual error squares is 2.51×10−4 V2. Then the output voltage can be used to predict the LO power and the corresponding shot noise variance without using a fiber optical coupler and power meter. The new type TBHD can significantly reduce the complexity and cost of the receiver side of CVQKD system. At the same time, it effectively avoids the security vulnerability due to the varying ratio of the fiber optical coupler and enhance the actual security of the system.

DOI
10.3788/jqo20243002.0304

Related papers

Highprecision auto-balance of the time-domain pulsed homodyne detector

Jianqiang Liu, Xuyang Wang, Bai Zeng-Liang +1 more

Quantum key distributions, which could make legitimate communication parties Alice and Bob achieve the same random key with unconditional security, will have broad applications in defense, commerce, and communication. The protocol of the continuous variable quantum key distribution (CVQKD) has many advantages, such as easy preparation of the light source, high detector efficiency, and good compatibility with the classic fiber-optic communication systems. In recent years, great progress in the research of CVQKD has been made both theoretically and experimentally. In the protocol, the quadratures of the optical field with Gaussian or Non-Gaussian modulation are employed as the carriers of the key.The quadratures of the pulsed optical quantum states in CVQKD can be detected with a time-domain pulsed homodyne detector. The performance of the detector has great influences on the excess noises and the safe key rate of the quantum communication system. The measurement accuracy, which depends crucially on the common mode rejection ratio and the long-term stability, is the key performance of the detector. In order to improve the accuracy of measurement and avoid saturating the detector, we propose and demonstrate a technique to balance the two output beams of a 50/50 fiber coupler of the homodyne detector automatically. The auto-balance technique, which improves the long-term stability and high common mode rejection ratio, is described in the following.Firstly, the relation between the balance degree and the measurement accuracy is theoretically analyzed in detail. The result shows that a balance degree larger than 10-4 should be reached to ensure a high precision measurement when the intensity of the local oscillator pulse is 108 photons per pulse. Secondly, a fiber-based variable attenuator based on computer-controlled linear stepper motor is designed. The linear stepper motor that is used to drive the fiber coils has a small dimension of 20 cm20 cm28 cm and a minimum step size of 78 nm, and is controlled through the I/O port of a multifunction data acquisition card connected to a computer. The attenuations of the fiber coils of different radii are detected. The precision of attenuation is estimated to be on the order of 10-6 per 100 nm.The principle of the feedback control is described. A method of changing step-size which depends on the balance degree is proposed to fulfill a fast auto-balance process. Using the auto-feedback-control system, a balance degree of about 1.5610-6 can be achieved. The procedure of auto-balance takes about 1 s, and the evolution curves that represent the transformation process from various unbalanced states to the balanced state are presented.The auto-balance apparatus can ensure that the time-domain pulsed homodyne detector run stably in a longterm with a high common mode rejection ratio. The nonlinear and saturation effects due to the drift of the balance point are eliminated. The presented auto-balance time-domain pulsed homodyne detector can be well integrated into the continuous variable quantum key distribution system, and is expected to play an important role in improving the measurement accuracy and reducing the excess noises of the system. We believe that it could also be found to have potential applications in other areas.

Acta Physica Sinica•Jan 1, 2016•9 citations

Accurate Shot-Noise-Limited Calibration of a Time-Domain Balanced Homodyne Detector for Continuous-Variable Quantum Key Distribution

Xuyang Wang, Xubo Guo, Yan-Xiang Jia +4 more

The time-domain balanced homodyne detector (TBHD) is critical component in continuous-variable quantum key distribution (CVQKD). The shot-noise-limited attribute of a TBHD depends on the whole frequency spectrum of the detector, in contrast to a frequency-domain balanced homodyne detector that focuses only on part of the frequency spectrum. We propose a method for accurate calibration of the shot-noise-limited attribute of the TBHD by overlapping the gain lines of the TBHD and an integral photodetector which is realized by blocking one photodiode of the TBHD. The overlapping of two lines indicates that the detector is indeed shot noise limited, which is crucial to the security of CVQKD. Experimentally, we use this method to obtain a calibration error of$\pm 1$‰. Theoretical analysis showed that the CVQKD security is very sensitive to calibration errors of shot noise, and proper countermeasure was proposed to eliminate this issue. The presented methods are expected to contribute to CVQKD security and TBHD standardization.

Journal of Lightwave Technology•Apr 3, 2023•14 citations

基于R‑C耦合跨阻设计的1 kHz~200 MHz宽带平衡零拍探测器

王少锋 Wang Shaofeng, 刘宣泽 Liu Xuanze, 李汉卿 Li Hanqing +2 more

Objective The balanced homodyne detector (BHD) is widely used in quantum noise measurement, gravitational wave detection, high-sensitivity interferometric timing measurement, continuous-variable quantum key distribution, and quantum random number generation. Highly sensitive to the amplitude and phase of the incident light, the BHD can reliably extract quantum fluctuations, suppress the classical common-mode noise, and amplify quantum fluctuations to the macro level. However, the performance of the BHD is limited by the bandwidth, signal-to-noise ratio (SNR), and common-mode rejection ratio (CMRR) of the detector. The optimal design of the BHD has always been a research hotspot. The transimpedance circuit based on a direct current (DC) coupled circuit is not suitable for detecting quantum noise. The reason is that as the power of the incident light increases, the unbalanced DC increases rapidly, and the transimpedance amplifier is saturated, which significantly reduces the dynamic range of the BHD. The BHD based on an inductor-capacitor (L-C) coupled circuit generates higher electronic noise at an analyzing frequency in the kHz range. It is not suitable for low-frequency measurements due to the parasitic effect of the inductor and the low impedance of the inductor at an analyzing frequency in the kHz range. In this paper, the noise sources of the BHD are analyzed theoretically, and a resistor-capacitor (R-C) coupled transimpedance circuit is used to improve the performance of the BHD at an analyzing frequency in the kHz range. Furthermore, the transimpedance circuit is optimized to increase the bandwidth to 200 MHz. The CMRR of the BHD is improved by designing a self-subtraction photodetector scheme, a variable optical attenuator, and an adjustable reverse bias voltage. These designs allow the BHD to meet the low-frequency and high-frequency measurements with high SNR and CMRR in quantum noise measurement. Methods To enable the BHD to measure both low-frequency and high-frequency signals with high sensitivity, this paper adopts the BHD based on an R-C coupled transimpedance circuit. Two photodiodes are connected in series, and the balanced current signal in the two photodiodes is divided into a DC signal and an alternating current (AC) signal by the R-C coupled structure. The AC signal is converted into a voltage signal by a transimpedance amplifier (TIA) and is further used to measure the shot-noise power of the incident light. The DC signal is converted into a voltage signal by a load resistor and is then used to measure the balance between the two incident lights. To reduce the crosstalk between the DC circuit and the AC circuit, an isolation amplifier is added after the load resistor. An adjustable bias voltage (BV) circuit is used to adjust the junction capacitance of the photodiodes and further improve the CMRR. To compensate for the difference in the amplitude of the two photodiodes and thereby improve the CMRR of the BHD, the paper also utilizes a variable optical attenuator based on fiber bending, where variable attenuation is achieved by changing the radius of the bent fiber. The attenuation of the fiber is precisely adjusted to balance the photocurrent. In addition, an equivalent noise model is constructed. The electronic noise from the TIA circuit includes four parts, i.e., the noise introduced by the dark current in the photodiodes, the thermal noise in the feedback resistor, the noise generated by the input current noise in the TIA, and the noise produced by the input voltage noise. On the basis of theoretical analysis, reasonable DC load resistance and feedback capacitance, photodiodes with low dark current and low junction capacitance, and a TIA with low input noise are selected to reduce the electronic noise and improve the SNR of the BHD. Results and Discussions A BHD with an R-C coupled circuit structure is designed (Fig. 1). A test device is built to test the performance of the BHD. The AC output is connected with a spectrometer to measure the bandwidth and the SNR of the BHD. The DC output is connected with an oscilloscope to make sure that the power of the two incident lights is balanced (Fig. 3). When the incident optical power is 8, 4, 2, and 1 mW, respectively, the paper tests the shot-noise spectrum and the electronic noise spectrum of the BHD with different analyzing frequencies. The test results show that the 3-dB bandwidth of the BHD is 1 kHz-200 MHz. The resolution bandwidth (RBW) and the video bandwidth (VBW) of the spectrum analyzer are set to 10 Hz and 1 Hz, respectively, and the number of averaging times is set to 40. In this case, the SNR is 12 dB at the analyzing frequency of 5 kHz under an incident optical power of 8 mW. The SNR is 20 dB at the analyzing frequency of 100 MHz when the RBW is 200 kHz and the VBW is 100 Hz. Moreover, in the analyzing frequency range of 10 kHz-200 MHz, the shot-noise power decreases by about 3 dB when the incident optical power decreases by half, indicating that the AC output of the BHD has favorable linear gain characteristics in the range of 1 mW to 8 mW (Fig. 4). In addition, 5 kHz and 100 MHz sinusoidal signals are loaded into an electro-optical amplitude modulator to modulate the incident light and thereby test the CMRR. The results show that the CMRR is 70 dB at the analyzing frequency of 5 kHz and 66 dB at the analyzing frequency of 100 MHz (Fig. 5). Conclusions By analyzing the noise sources of the BHD, adopting the R-C coupled transimpedance circuit, and optimizing the TIA circuit, this paper implements a broadband balanced homodyne detector that works in the bandwidth range from 1 kHz to 200 MHz with low noise and high CMRR. In the case of an incident optical power of 8 mW@1550 nm, the shot-noise power is 12 dB higher than the electronic noise power and the CMRR reaches 70 dB at the analyzing frequency of 5 kHz, and the shot-noise power is 20 dB higher than the electronic noise power and the CMRR reaches 66 dB at the analyzing frequency of 100 MHz. Such a homodyne detector can serve as a high-performance detection tool in various applications, such as low-frequency gravitational wave detection, high-speed continuous-variable quantum key distribution, and high-speed quantum random number generation.

Acta Optica Sinica•Jan 1, 2023•7 citations

多像素平衡零拍探测器研究

王少锋 Wang Shaofeng, 李汉卿 Li Hanqing, 李康康 Li Kangkang +3 more

Objective As an important tool for quantum optical measurement, the balanced homodyne detector (BHD) is highly sensitive to the amplitude and phase of the incident light. It can reliably extract quantum fluctuations, suppress classical common-mode noise, and amplify quantum fluctuations to the macro level. Additionally, it has been widely employed in quantum noise measurement, gravitational wave detection, high-sensitivity interferometric timing measurement, continuous variable quantum key distribution, and quantum random number generator. The common-mode rejection ratio (CMRR), operating bandwidth, and signal-to-noise ratio (SNR) of the detector have been the research focuses. The optical frequency comb contains a large number of equally spaced longitudinal modes, which is a good multi-mode resource. The spectrum width of the optical frequency comb is in the order of nanometers. The quantum optical frequency comb which breaks the limit of shot noise can be generated by nonlinear processes. Quantum optical frequency comb has a great application prospect in quantum precision measurement. Spectrally resolved balanced homodyne detection is an important detection method of quantum optical frequency comb. We analyze the noise source of the balanced homodyne detector theoretically and design the multi-pixel balanced homodyne detector (MBHD) based on photodiode array and multi-channel inductance-capacitance (L-C) coupled transimpedance amplifier (TIA) circuit. These designs enable MBHD to meet multi-channel parallel and high-SNR quantum noise measurements. Methods The MBHD consists of two highly symmetrical multi-pixel photodetectors (MPDs) and a multi-channel subtracter (Fig. 1). Each MPD includes a photodiode array, a multi-channel L-C coupled structure, AC amplification, and DC amplification. The photocurrent generated by the corresponding pair of pixels in the two MPD flows through their respective AC amplification outputs, and the common-mode signal in the detection result is eliminated by the subtracter to complete the multi-pixel parallel balanced homodyne detection. Multi-channel DC output monitors the optical power of all pixels by a multi-function data acquisition card (DAQ). In the amplification circuit structure of the single pixel in MPD, the generated photocurrent signal is divided into DC signal and AC signal through the L-C coupled circuit. The AC signal is converted into a voltage signal by a TIA and is further adopted to measure the intensity noise power of the incident light. The DC signal is converted into a voltage signal by a load resistor and a isolation amplifier. Additionally, an equivalent noise model is built to analyze the electronic noise. Due to the multi-channel parallel structure of the MBHD, each channel is similar to each other and independent. The electronic noise of the single-pixel channel includes the noise generated by the dark current of the photodiode, the thermal noise generated by the feedback resistance in the transimpedance amplifier circuit, the noise generated by the input voltage noise of the transimpedance amplifier, and the noise generated by the input current noise of the transimpedance amplifier. Theoretical analysis shows that a reasonable selection of feedback resistance and inductance, photodiode with low dark current and low junction capacitance, and the TIA with low input noise can reduce the electronic noise of the detector. Meanwhile, the L-C coupled structure is better than the R-C coupled structure in experimental conditions (Fig. 2). Results and Discussions The device is constructed to test the performance of MBHD (Fig. 3). AC output of MBHD is connected to a spectrometer to measure the bandwidth and SNR. The DC signals of each pixel are measured by a DAQ to monitor the optical powers of each pixel. When the optical power is distributed on all pixel channels, the distribution of the shot noise power in each channel is proportional to the distribution of the incident optical power, which verifies that the multi-pixel BHD can achieve spectrally resolved multi-channel parallel balanced homodyne detection (Fig. 4). When the incident optical power is 1.660 mW, 0.834 mW, 0.418 mW, 0.208 mW, and 0.102 mW respectively, the shot noise spectrum and electronic noise spectrum of one pixel are measured at different analysis frequencies (Fig. 5). The test results show that the 3 dB bandwidth of MBHD is 5 MHz. The resolution bandwidth is set to 100 kHz, the video bandwidth is 100 Hz, and the number of averaging times is 10. When the incident optical power is 1.660 mW, the shot noise power is 23 dB higher than the electronic noise power at the analysis frequency of 2 MHz. By comparing the shot noise power under different incident optical power, the shot noise power decreases by 3 dB when the incident optical power decreases by half, which indicates that the detector has a good linear gain within 0.102 mW to 1.660 mW of the optical power. Conclusions Based on the noise model of the BHD, the electronic noise source is analyzed theoretically. The results indicate that the L-C coupled structure is better. By adopting the multi-pixel photodiode array and L-C coupled structure, a high-performance multi-pixel BHD is developed. In each pixel channel, when the 815 nm laser with optical power of 1.660 mW is incident, the shot noise power is 23 dB higher than the electronic noise at the analysis frequency of 2 MHz. By employing the grating to scatter the incident light horizontally, the shot noise power in each channel is proportional to the incident optical power. It is verified that the multi-pixel BHD can realize the spectrally resolved multi-channel parallel balanced homodyne detection. The detector provides a high-performance detection tool for quantum precision measurement based on quantum optical frequency comb.

Acta Optica Sinica•Jan 1, 2024•2 citations

高性能GHz带宽平衡零拍探测器的研制

段放世 Fangshi DUAN, 李超 Chao LI, 索普一 Puyi SUO +1 more

ObjectiveHigh performance balanced homodyne detectors with high bandwidth, high quantum efficiency, reasonable gain, and high common-mode rejection ratio are critical in the fields of high-speed quantum communication, broadband squeezed light and entangled light detection, and broadband quantum precision measurement. However, it is challenging to design and develop GHz bandwidth balanced homodyne detectors with overall high performance. For example, the actually achieved bandwidth and gain are usually limited by the distributed capacitance of the circuit board. Furthermore, high common-mode rejection ratio, linear response and low noise performance are also technically challenging due to fabrication and soldering processes of the printed circuit board (PCB).MethodsIn comparison with other high bandwidth balanced homodyne detectors developed in previous works, we have adopted a design that separates alternating current (AC) and direct current (DC). The DC output helps us monitor the optical power and ensures the balance of the two photodiodes, which is crucial for balanced homodyne detection in quantum optical experiments. Our circuit board design involves placing two photodiodes on opposite sides of the PCB. This makes it easier to ensure the circuit lengths of the two photodiodes are exactly the same and reduce the distributed capacitance of the circuit board. This is important for enhancing the detector bandwidth and improving the common-mode rejection ratio. Additionally, this design is more convenient for quantum optical experiment operations.Results and DiscussionsWe used two photodiodes with 95% quantum efficiency, low capacitance and dark current for our balanced homodyne detector. The DC gain of the balanced homodyne detector is 1003.6 V/W, which is at a reasonable level for optical power monitor. We also took the noise power spectra of the balanced homodyne detector at different optical powers. We demonstrate the detector response is linear at five different frequencies. An effective bandwidth of 1 GHz and a maximum signal-to-noise ratio of 12 dB were realized at 1550 nm. The common-mode rejection ratio of the homodyne detector was tested by modulating the input beam with an electro-optical modulator. By placing two photodiodes symmetrically on the front and back sides of the double-sided PCB board, a common-mode rejection ratio of 60.65 dB at 20 MHz was achieved. Subsequently, the balanced homodyne detector was used to measure 1550 nm quadrature amplitude squeezed light. Up to -2.5 dB squeezing was observed over a bandwidth range from 3.5 MHz to 71.5 MHz.ConclusionsIn this paper, we designed and developed a balanced homodyne detector with GHz bandwidth, high quantum efficiency, reasonable gain, and high common-mode rejection ratio. The results show that the balanced homodyne detector with high bandwidth and high common-mode rejection ratio are useful in broadband squeezed state measurement.

Acta Sinica Quantum Optica•Jan 1, 2025•0 citations

Silicon photonics-integrated time-domain balanced homodyne detector for quantum tomography and quantum key distribution

Yan-Xiang Jia, Xuyang Wang, Xiao Hu +8 more

We designed and experimentally demonstrated a silicon photonics-integrated time-domain balanced homodyne detector (TBHD), containing an optical part of dimensions of 1.5 mm × 0.4 mm. To automatically and accurately balance the detector, new variable optical attenuators were used, and a common mode rejection ratio of 86.9 dB could be achieved. In the quantum tomography experiment, the density matrix and Wigner function of a coherent state were reconstructed with 99.97% fidelity. The feasibility of this TBHD in a continuous-variable quantum key distribution (CVQKD) system was also demonstrated. Our TBHD technologies are expected to be used in silicon photonics-integrated CVQKD system and silicon photonics-integrated BB84 heterodyne system.

arXiv:2305.03419•New Journal of Physics•Oct 1, 2023•26 citations
The time-domain balanced homodyne detector (TBHD) can be used to detect the quadratures of the pulsed optical signal directly, and it is a crucial component of the continuous variable quantum key distribution (CVQKD) system. At the receiver side of the CVQKD system, the recovery of clock signal and the monitoring of local oscillator (LO) power is realized using fiber optic couplers, photodetectors and power meters usually. The fiber optical couplers not only reduce the LO power but also introduce security vulnerability. To simplify the structure of the receiver side, reduce the cost and increase the security of CVQKD system, we design and experimentally realize a new type TBHD with clock recovery and power monitoring functions. The detector makes full use of the photoelectron current generated by the cascaded photodiode. It can not only measure the quadratures of the pulsed optical signal, but also monitor the LO power in real-time and generate the clock signal with the same frequency as the LO beam. In experiment, a common mode rejection ratio of 75 dB could be obtained, and a maximum signal-to-noise ratio of 13.50 dB could be measured at a repetition rate of 1 MHz. At the same time, the clock signals with the same frequency as the LO beam were generated, and the output voltage value scales with the LO power was measured. A good linear relationship between the output voltages and the LO powers was obtained. The fitting slope or gain is 2.52×10−7 V/photon, and the sum of residual error squares is 2.51×10−4 V2. Then the output voltage can be used to predict the LO power and the corresponding shot noise variance without using a fiber optical coupler and power meter. The new type TBHD can significantly reduce the complexity and cost of the receiver side of CVQKD system. At the same time, it effectively avoids the security vulnerability due to the varying ratio of the fiber optical coupler and enhance the actual security of the system.
Quantum key distributions, which could make legitimate communication parties Alice and Bob achieve the same random key with unconditional security, will have broad applications in defense, commerce, and communication. The protocol of the continuous variable quantum key distribution (CVQKD) has many advantages, such as easy preparation of the light source, high detector efficiency, and good compatibility with the classic fiber-optic communication systems. In recent years, great progress in the research of CVQKD has been made both theoretically and experimentally. In the protocol, the quadratures of the optical field with Gaussian or Non-Gaussian modulation are employed as the carriers of the key.The quadratures of the pulsed optical quantum states in CVQKD can be detected with a time-domain pulsed homodyne detector. The performance of the detector has great influences on the excess noises and the safe key rate of the quantum communication system. The measurement accuracy, which depends crucially on the common mode rejection ratio and the long-term stability, is the key performance of the detector. In order to improve the accuracy of measurement and avoid saturating the detector, we propose and demonstrate a technique to balance the two output beams of a 50/50 fiber coupler of the homodyne detector automatically. The auto-balance technique, which improves the long-term stability and high common mode rejection ratio, is described in the following.Firstly, the relation between the balance degree and the measurement accuracy is theoretically analyzed in detail. The result shows that a balance degree larger than 10-4 should be reached to ensure a high precision measurement when the intensity of the local oscillator pulse is 108 photons per pulse. Secondly, a fiber-based variable attenuator based on computer-controlled linear stepper motor is designed. The linear stepper motor that is used to drive the fiber coils has a small dimension of 20 cm20 cm28 cm and a minimum step size of 78 nm, and is controlled through the I/O port of a multifunction data acquisition card connected to a computer. The attenuations of the fiber coils of different radii are detected. The precision of attenuation is estimated to be on the order of 10-6 per 100 nm.The principle of the feedback control is described. A method of changing step-size which depends on the balance degree is proposed to fulfill a fast auto-balance process. Using the auto-feedback-control system, a balance degree of about 1.5610-6 can be achieved. The procedure of auto-balance takes about 1 s, and the evolution curves that represent the transformation process from various unbalanced states to the balanced state are presented.The auto-balance apparatus can ensure that the time-domain pulsed homodyne detector run stably in a longterm with a high common mode rejection ratio. The nonlinear and saturation effects due to the drift of the balance point are eliminated. The presented auto-balance time-domain pulsed homodyne detector can be well integrated into the continuous variable quantum key distribution system, and is expected to play an important role in improving the measurement accuracy and reducing the excess noises of the system. We believe that it could also be found to have potential applications in other areas.
The time-domain balanced homodyne detector (TBHD) is critical component in continuous-variable quantum key distribution (CVQKD). The shot-noise-limited attribute of a TBHD depends on the whole frequency spectrum of the detector, in contrast to a frequency-domain balanced homodyne detector that focuses only on part of the frequency spectrum. We propose a method for accurate calibration of the shot-noise-limited attribute of the TBHD by overlapping the gain lines of the TBHD and an integral photodetector which is realized by blocking one photodiode of the TBHD. The overlapping of two lines indicates that the detector is indeed shot noise limited, which is crucial to the security of CVQKD. Experimentally, we use this method to obtain a calibration error of±1\pm 1±1‰. Theoretical analysis showed that the CVQKD security is very sensitive to calibration errors of shot noise, and proper countermeasure was proposed to eliminate this issue. The presented methods are expected to contribute to CVQKD security and TBHD standardization.
Objective The balanced homodyne detector (BHD) is widely used in quantum noise measurement, gravitational wave detection, high-sensitivity interferometric timing measurement, continuous-variable quantum key distribution, and quantum random number generation. Highly sensitive to the amplitude and phase of the incident light, the BHD can reliably extract quantum fluctuations, suppress the classical common-mode noise, and amplify quantum fluctuations to the macro level. However, the performance of the BHD is limited by the bandwidth, signal-to-noise ratio (SNR), and common-mode rejection ratio (CMRR) of the detector. The optimal design of the BHD has always been a research hotspot. The transimpedance circuit based on a direct current (DC) coupled circuit is not suitable for detecting quantum noise. The reason is that as the power of the incident light increases, the unbalanced DC increases rapidly, and the transimpedance amplifier is saturated, which significantly reduces the dynamic range of the BHD. The BHD based on an inductor-capacitor (L-C) coupled circuit generates higher electronic noise at an analyzing frequency in the kHz range. It is not suitable for low-frequency measurements due to the parasitic effect of the inductor and the low impedance of the inductor at an analyzing frequency in the kHz range. In this paper, the noise sources of the BHD are analyzed theoretically, and a resistor-capacitor (R-C) coupled transimpedance circuit is used to improve the performance of the BHD at an analyzing frequency in the kHz range. Furthermore, the transimpedance circuit is optimized to increase the bandwidth to 200 MHz. The CMRR of the BHD is improved by designing a self-subtraction photodetector scheme, a variable optical attenuator, and an adjustable reverse bias voltage. These designs allow the BHD to meet the low-frequency and high-frequency measurements with high SNR and CMRR in quantum noise measurement. Methods To enable the BHD to measure both low-frequency and high-frequency signals with high sensitivity, this paper adopts the BHD based on an R-C coupled transimpedance circuit. Two photodiodes are connected in series, and the balanced current signal in the two photodiodes is divided into a DC signal and an alternating current (AC) signal by the R-C coupled structure. The AC signal is converted into a voltage signal by a transimpedance amplifier (TIA) and is further used to measure the shot-noise power of the incident light. The DC signal is converted into a voltage signal by a load resistor and is then used to measure the balance between the two incident lights. To reduce the crosstalk between the DC circuit and the AC circuit, an isolation amplifier is added after the load resistor. An adjustable bias voltage (BV) circuit is used to adjust the junction capacitance of the photodiodes and further improve the CMRR. To compensate for the difference in the amplitude of the two photodiodes and thereby improve the CMRR of the BHD, the paper also utilizes a variable optical attenuator based on fiber bending, where variable attenuation is achieved by changing the radius of the bent fiber. The attenuation of the fiber is precisely adjusted to balance the photocurrent. In addition, an equivalent noise model is constructed. The electronic noise from the TIA circuit includes four parts, i.e., the noise introduced by the dark current in the photodiodes, the thermal noise in the feedback resistor, the noise generated by the input current noise in the TIA, and the noise produced by the input voltage noise. On the basis of theoretical analysis, reasonable DC load resistance and feedback capacitance, photodiodes with low dark current and low junction capacitance, and a TIA with low input noise are selected to reduce the electronic noise and improve the SNR of the BHD. Results and Discussions A BHD with an R-C coupled circuit structure is designed (Fig. 1). A test device is built to test the performance of the BHD. The AC output is connected with a spectrometer to measure the bandwidth and the SNR of the BHD. The DC output is connected with an oscilloscope to make sure that the power of the two incident lights is balanced (Fig. 3). When the incident optical power is 8, 4, 2, and 1 mW, respectively, the paper tests the shot-noise spectrum and the electronic noise spectrum of the BHD with different analyzing frequencies. The test results show that the 3-dB bandwidth of the BHD is 1 kHz-200 MHz. The resolution bandwidth (RBW) and the video bandwidth (VBW) of the spectrum analyzer are set to 10 Hz and 1 Hz, respectively, and the number of averaging times is set to 40. In this case, the SNR is 12 dB at the analyzing frequency of 5 kHz under an incident optical power of 8 mW. The SNR is 20 dB at the analyzing frequency of 100 MHz when the RBW is 200 kHz and the VBW is 100 Hz. Moreover, in the analyzing frequency range of 10 kHz-200 MHz, the shot-noise power decreases by about 3 dB when the incident optical power decreases by half, indicating that the AC output of the BHD has favorable linear gain characteristics in the range of 1 mW to 8 mW (Fig. 4). In addition, 5 kHz and 100 MHz sinusoidal signals are loaded into an electro-optical amplitude modulator to modulate the incident light and thereby test the CMRR. The results show that the CMRR is 70 dB at the analyzing frequency of 5 kHz and 66 dB at the analyzing frequency of 100 MHz (Fig. 5). Conclusions By analyzing the noise sources of the BHD, adopting the R-C coupled transimpedance circuit, and optimizing the TIA circuit, this paper implements a broadband balanced homodyne detector that works in the bandwidth range from 1 kHz to 200 MHz with low noise and high CMRR. In the case of an incident optical power of 8 mW@1550 nm, the shot-noise power is 12 dB higher than the electronic noise power and the CMRR reaches 70 dB at the analyzing frequency of 5 kHz, and the shot-noise power is 20 dB higher than the electronic noise power and the CMRR reaches 66 dB at the analyzing frequency of 100 MHz. Such a homodyne detector can serve as a high-performance detection tool in various applications, such as low-frequency gravitational wave detection, high-speed continuous-variable quantum key distribution, and high-speed quantum random number generation.
Objective As an important tool for quantum optical measurement, the balanced homodyne detector (BHD) is highly sensitive to the amplitude and phase of the incident light. It can reliably extract quantum fluctuations, suppress classical common-mode noise, and amplify quantum fluctuations to the macro level. Additionally, it has been widely employed in quantum noise measurement, gravitational wave detection, high-sensitivity interferometric timing measurement, continuous variable quantum key distribution, and quantum random number generator. The common-mode rejection ratio (CMRR), operating bandwidth, and signal-to-noise ratio (SNR) of the detector have been the research focuses. The optical frequency comb contains a large number of equally spaced longitudinal modes, which is a good multi-mode resource. The spectrum width of the optical frequency comb is in the order of nanometers. The quantum optical frequency comb which breaks the limit of shot noise can be generated by nonlinear processes. Quantum optical frequency comb has a great application prospect in quantum precision measurement. Spectrally resolved balanced homodyne detection is an important detection method of quantum optical frequency comb. We analyze the noise source of the balanced homodyne detector theoretically and design the multi-pixel balanced homodyne detector (MBHD) based on photodiode array and multi-channel inductance-capacitance (L-C) coupled transimpedance amplifier (TIA) circuit. These designs enable MBHD to meet multi-channel parallel and high-SNR quantum noise measurements. Methods The MBHD consists of two highly symmetrical multi-pixel photodetectors (MPDs) and a multi-channel subtracter (Fig. 1). Each MPD includes a photodiode array, a multi-channel L-C coupled structure, AC amplification, and DC amplification. The photocurrent generated by the corresponding pair of pixels in the two MPD flows through their respective AC amplification outputs, and the common-mode signal in the detection result is eliminated by the subtracter to complete the multi-pixel parallel balanced homodyne detection. Multi-channel DC output monitors the optical power of all pixels by a multi-function data acquisition card (DAQ). In the amplification circuit structure of the single pixel in MPD, the generated photocurrent signal is divided into DC signal and AC signal through the L-C coupled circuit. The AC signal is converted into a voltage signal by a TIA and is further adopted to measure the intensity noise power of the incident light. The DC signal is converted into a voltage signal by a load resistor and a isolation amplifier. Additionally, an equivalent noise model is built to analyze the electronic noise. Due to the multi-channel parallel structure of the MBHD, each channel is similar to each other and independent. The electronic noise of the single-pixel channel includes the noise generated by the dark current of the photodiode, the thermal noise generated by the feedback resistance in the transimpedance amplifier circuit, the noise generated by the input voltage noise of the transimpedance amplifier, and the noise generated by the input current noise of the transimpedance amplifier. Theoretical analysis shows that a reasonable selection of feedback resistance and inductance, photodiode with low dark current and low junction capacitance, and the TIA with low input noise can reduce the electronic noise of the detector. Meanwhile, the L-C coupled structure is better than the R-C coupled structure in experimental conditions (Fig. 2). Results and Discussions The device is constructed to test the performance of MBHD (Fig. 3). AC output of MBHD is connected to a spectrometer to measure the bandwidth and SNR. The DC signals of each pixel are measured by a DAQ to monitor the optical powers of each pixel. When the optical power is distributed on all pixel channels, the distribution of the shot noise power in each channel is proportional to the distribution of the incident optical power, which verifies that the multi-pixel BHD can achieve spectrally resolved multi-channel parallel balanced homodyne detection (Fig. 4). When the incident optical power is 1.660 mW, 0.834 mW, 0.418 mW, 0.208 mW, and 0.102 mW respectively, the shot noise spectrum and electronic noise spectrum of one pixel are measured at different analysis frequencies (Fig. 5). The test results show that the 3 dB bandwidth of MBHD is 5 MHz. The resolution bandwidth is set to 100 kHz, the video bandwidth is 100 Hz, and the number of averaging times is 10. When the incident optical power is 1.660 mW, the shot noise power is 23 dB higher than the electronic noise power at the analysis frequency of 2 MHz. By comparing the shot noise power under different incident optical power, the shot noise power decreases by 3 dB when the incident optical power decreases by half, which indicates that the detector has a good linear gain within 0.102 mW to 1.660 mW of the optical power. Conclusions Based on the noise model of the BHD, the electronic noise source is analyzed theoretically. The results indicate that the L-C coupled structure is better. By adopting the multi-pixel photodiode array and L-C coupled structure, a high-performance multi-pixel BHD is developed. In each pixel channel, when the 815 nm laser with optical power of 1.660 mW is incident, the shot noise power is 23 dB higher than the electronic noise at the analysis frequency of 2 MHz. By employing the grating to scatter the incident light horizontally, the shot noise power in each channel is proportional to the incident optical power. It is verified that the multi-pixel BHD can realize the spectrally resolved multi-channel parallel balanced homodyne detection. The detector provides a high-performance detection tool for quantum precision measurement based on quantum optical frequency comb.
ObjectiveHigh performance balanced homodyne detectors with high bandwidth, high quantum efficiency, reasonable gain, and high common-mode rejection ratio are critical in the fields of high-speed quantum communication, broadband squeezed light and entangled light detection, and broadband quantum precision measurement. However, it is challenging to design and develop GHz bandwidth balanced homodyne detectors with overall high performance. For example, the actually achieved bandwidth and gain are usually limited by the distributed capacitance of the circuit board. Furthermore, high common-mode rejection ratio, linear response and low noise performance are also technically challenging due to fabrication and soldering processes of the printed circuit board (PCB).MethodsIn comparison with other high bandwidth balanced homodyne detectors developed in previous works, we have adopted a design that separates alternating current (AC) and direct current (DC). The DC output helps us monitor the optical power and ensures the balance of the two photodiodes, which is crucial for balanced homodyne detection in quantum optical experiments. Our circuit board design involves placing two photodiodes on opposite sides of the PCB. This makes it easier to ensure the circuit lengths of the two photodiodes are exactly the same and reduce the distributed capacitance of the circuit board. This is important for enhancing the detector bandwidth and improving the common-mode rejection ratio. Additionally, this design is more convenient for quantum optical experiment operations.Results and DiscussionsWe used two photodiodes with 95% quantum efficiency, low capacitance and dark current for our balanced homodyne detector. The DC gain of the balanced homodyne detector is 1003.6 V/W, which is at a reasonable level for optical power monitor. We also took the noise power spectra of the balanced homodyne detector at different optical powers. We demonstrate the detector response is linear at five different frequencies. An effective bandwidth of 1 GHz and a maximum signal-to-noise ratio of 12 dB were realized at 1550 nm. The common-mode rejection ratio of the homodyne detector was tested by modulating the input beam with an electro-optical modulator. By placing two photodiodes symmetrically on the front and back sides of the double-sided PCB board, a common-mode rejection ratio of 60.65 dB at 20 MHz was achieved. Subsequently, the balanced homodyne detector was used to measure 1550 nm quadrature amplitude squeezed light. Up to -2.5 dB squeezing was observed over a bandwidth range from 3.5 MHz to 71.5 MHz.ConclusionsIn this paper, we designed and developed a balanced homodyne detector with GHz bandwidth, high quantum efficiency, reasonable gain, and high common-mode rejection ratio. The results show that the balanced homodyne detector with high bandwidth and high common-mode rejection ratio are useful in broadband squeezed state measurement.
We designed and experimentally demonstrated a silicon photonics-integrated time-domain balanced homodyne detector (TBHD), containing an optical part of dimensions of 1.5 mm × 0.4 mm. To automatically and accurately balance the detector, new variable optical attenuators were used, and a common mode rejection ratio of 86.9 dB could be achieved. In the quantum tomography experiment, the density matrix and Wigner function of a coherent state were reconstructed with 99.97% fidelity. The feasibility of this TBHD in a continuous-variable quantum key distribution (CVQKD) system was also demonstrated. Our TBHD technologies are expected to be used in silicon photonics-integrated CVQKD system and silicon photonics-integrated BB84 heterodyne system.