arXiv:2305.03419 · New Journal of Physics

Silicon photonics-integrated time-domain balanced homodyne detector for quantum tomography and quantum key distribution

Yan-Xiang Jia, Xuyang Wang, Xiao Hu, Xin Hua, Yu Zhang, Xubo Guo, Shengxiang Zhang, Xi Xiao, Shaohua Yu, Jun Zou, Yongmin Li

Published Sep 25, 2023• 15 citations
arXivHTMLPDF

Abstract

Abstract We designed and experimentally demonstrated a silicon photonics-integrated time-domain balanced homodyne detector (TBHD), containing an optical part of dimensions of 1.5 mm × 0.4 mm. To automatically and accurately balance the detector, new variable optical attenuators were used, and a common mode rejection ratio of 86.9 dB could be achieved. In the quantum tomography experiment, the density matrix and Wigner function of a coherent state were reconstructed with 99.97% fidelity. The feasibility of this TBHD in a continuous-variable quantum key distribution (CVQKD) system was also demonstrated. Our TBHD technologies are expected to be used in silicon photonics-integrated CVQKD system and silicon photonics-integrated BB84 heterodyne system.

DOI
10.1088/1367-2630/acfcd4

Related papers

Accurate Shot-Noise-Limited Calibration of a Time-Domain Balanced Homodyne Detector for Continuous-Variable Quantum Key Distribution

Xuyang Wang, Xubo Guo, Yan-Xiang Jia +4 more

Abstract The time-domain balanced homodyne detector (TBHD) is critical component in continuous-variable quantum key distribution (CVQKD). The shot-noise-limited attribute of a TBHD depends on the whole spectrum of detector, in contrast to a frequency-domain balanced homodyne detector that focuses only on part of the spectrum. We propose a method for accurate calibration of the shot-noise-limited attribute of the TBHD by overlapping the gain lines of the TBHD and an integrated photodetector. The overlapping of two lines indicates that the detector is indeed shot noise limited, which is crucial to the security of CVQKD. Experimentally, we use this method to obtain a calibration error of ±1‰. Theoretical analysis showed that the CVQKD performance is very sensitive to calibration errors of shot noise, and proper countermeasures should be employed to eliminate this issue. The presented methods are expected to contribute to CVQKD security and TBHD standardization.

Journal of Lightwave Technology•Apr 3, 2023•12 citations

Integrated balanced homodyne photonic–electronic detector for beyond 20 GHz shot-noise-limited measurements

Cédric Bruynsteen, Michael Vanhoecke, Johan Bauwelinck +1 more

Optical homodyne detection is used in numerous quantum and classical applications that demand high levels of sensitivity. However, performance is typically limited due to the use of bulk optics and discrete receiver electronics. To address these performance issues, in this work we present a co-integrated balanced homodyne detector consisting of a silicon photonics optical front end and a custom integrated transimpedance amplifier designed in a 100 nm GaAs pHEMT technology. The high level of co-design and integration provides enhanced levels of stability, bandwidth, and noise performance. The presented detector shows a linear operation up to 28 dB quantum shot noise clearance and a high degree of common-mode rejection, at the same time achieving a shot-noise-limited bandwidth of more than 20 GHz. The high performance of the developed devices provide enhanced operation to many sensitive quantum applications such as continuous variable quantum key distribution, quantum random number generation, or high-speed quantum tomography.

Optica•Jul 23, 2021•90 citations

Design and characterization of wideband balanced homodyne detectors for quantum homodyne tomography

Erick Barrios Barocio

This thesis reports the realization and applications of a versatile wideband balanced homodyne detector operating in the time domain and intended for Quantum Optical Tomography. The detector can work with high repetition rate lasers used for the production and measurement of the electric field quadratures of quantum states of light. Full characterization of the detector by shot-noise measurements and by verifying its capability to reconstruct the density matrix and Wigner function of various states of interest is given. By overcoming photodiodes response mismatch, high frequency electronics issues and by choosing an appropriate optical set-up, a high level of common mode suppression (52.4dB) and a low electronic noise gave a shot-to-electronic noise ratio of I3dB for a Local Oscillator with 6.2 x 108 photons-per-pulse on a ~ 100MHz bandwidth. Results for the characterization of a single-photon Fock state are presented. An average efficiency of 56% was obtained for the generation/detection of the state.

•Jan 1, 2012•0 citations

Integrated balanced homodyne detector using CMOS capacitive-feedback TIA for quantum measurements

Sarah Bastiaens, Cedric Bruynsteen, Simone Cammarata +5 more

A low-noise, high-speed balanced homodyne detector is demonstrated, combining a capacitive-feedback transimpedance amplifier implemented in 28 nm CMOS with a custom photonic integrated circuit fabricated in imec's iSiPP200 silicon photonics platform. The receiver achieves a 3-dB bandwidth of 7.6 GHz, a maximum shot noise clearance of 27 dB, a shot noise-limited bandwidth of 13.7 GHz and a common-mode rejection ratio up to 54.8 dB. These results demonstrate the suitability of CMOS capacitive-feedback transimpedance amplifiers for demanding quantum and coherent sensing optical applications, including continuous-variable quantum key distribution, quantum random number generation, and optical coherence tomography.

quant-pharXiv:2609.37671•Sep 30, 2026•0 citations

1.2-GHz Balanced Homodyne Detector for Continuous-Variable Quantum Information Technology

Xiaoxiong Zhang, Yichen Zhang, Zhengyu Li +2 more

Balanced homodyne detector (BHD) that can measure the field quadratures of coherent states has been widely used in a range of quantum information technologies. Generally, the BHD tends to suffer from narrow bands and an expanding bandwidth behavior usually traps into a compromise with the gain, electronic noise, and quantum to classical noise ratio, etc. In this paper, we design and construct a wideband BHD based on radio frequency and integrated circuit technology. Our BHD shows bandwidth behavior up to 1.2 GHz and its quantum to classical noise ratio is around 18 dB. Simultaneously, the BHD has a linear performance with a gain of 4.86 k and its common mode rejection ratio has also been tested as 57.9 dB. With this BHD, the secret key rate of continuous-variable quantum key distribution system has a potential to achieve 66.55 Mb/s and 2.87 Mb/s, respectively, at the transmission distance of 10 and 45 km. Besides, with this BHD, the generation rate of quantum random number generator could reach up to 6.53 Gb/s.

arXiv:1806.09393•IEEE photonics journal•Aug 23, 2018•99 citations

Ultrasensitive pulsed, balanced homodyne detector: application to time-domain quantum measurements

Hauke Hansen, Thomas Aichele, Christian Hettich +4 more

A pulsed, balanced homodyne detector has been developed for precise measurement of the electric field quadratures of pulsed optical quantum states. A high level of common mode suppression (>85 dB) and low electronic noise (730 electrons per pulse) provide a signal-to-noise ratio of 14 dB for measurement of the quantum noise of individual pulses. Measurements at repetition rates as high as 1 MHz are possible. As a test, quantum tomography of the coherent state was performed, and the Wigner function and the density matrix were reconstructed with 99.5% fidelity. The detection system can be used for ultrarsensitive balanced detection in cw mode, e.g., for weak absorption measurements.

arXiv:quant-ph/0104084•Optics Letters•Nov 1, 2001•143 citations
Abstract We designed and experimentally demonstrated a silicon photonics-integrated time-domain balanced homodyne detector (TBHD), containing an optical part of dimensions of 1.5 mm × 0.4 mm. To automatically and accurately balance the detector, new variable optical attenuators were used, and a common mode rejection ratio of 86.9 dB could be achieved. In the quantum tomography experiment, the density matrix and Wigner function of a coherent state were reconstructed with 99.97% fidelity. The feasibility of this TBHD in a continuous-variable quantum key distribution (CVQKD) system was also demonstrated. Our TBHD technologies are expected to be used in silicon photonics-integrated CVQKD system and silicon photonics-integrated BB84 heterodyne system.
Abstract The time-domain balanced homodyne detector (TBHD) is critical component in continuous-variable quantum key distribution (CVQKD). The shot-noise-limited attribute of a TBHD depends on the whole spectrum of detector, in contrast to a frequency-domain balanced homodyne detector that focuses only on part of the spectrum. We propose a method for accurate calibration of the shot-noise-limited attribute of the TBHD by overlapping the gain lines of the TBHD and an integrated photodetector. The overlapping of two lines indicates that the detector is indeed shot noise limited, which is crucial to the security of CVQKD. Experimentally, we use this method to obtain a calibration error of ±1‰. Theoretical analysis showed that the CVQKD performance is very sensitive to calibration errors of shot noise, and proper countermeasures should be employed to eliminate this issue. The presented methods are expected to contribute to CVQKD security and TBHD standardization.
Optical homodyne detection is used in numerous quantum and classical applications that demand high levels of sensitivity. However, performance is typically limited due to the use of bulk optics and discrete receiver electronics. To address these performance issues, in this work we present a co-integrated balanced homodyne detector consisting of a silicon photonics optical front end and a custom integrated transimpedance amplifier designed in a 100 nm GaAs pHEMT technology. The high level of co-design and integration provides enhanced levels of stability, bandwidth, and noise performance. The presented detector shows a linear operation up to 28 dB quantum shot noise clearance and a high degree of common-mode rejection, at the same time achieving a shot-noise-limited bandwidth of more than 20 GHz. The high performance of the developed devices provide enhanced operation to many sensitive quantum applications such as continuous variable quantum key distribution, quantum random number generation, or high-speed quantum tomography.
This thesis reports the realization and applications of a versatile wideband balanced homodyne detector operating in the time domain and intended for Quantum Optical Tomography. The detector can work with high repetition rate lasers used for the production and measurement of the electric field quadratures of quantum states of light. Full characterization of the detector by shot-noise measurements and by verifying its capability to reconstruct the density matrix and Wigner function of various states of interest is given. By overcoming photodiodes response mismatch, high frequency electronics issues and by choosing an appropriate optical set-up, a high level of common mode suppression (52.4dB) and a low electronic noise gave a shot-to-electronic noise ratio of I3dB for a Local Oscillator with 6.2 x 108 photons-per-pulse on a ~ 100MHz bandwidth. Results for the characterization of a single-photon Fock state are presented. An average efficiency of 56% was obtained for the generation/detection of the state.
A low-noise, high-speed balanced homodyne detector is demonstrated, combining a capacitive-feedback transimpedance amplifier implemented in 28 nm CMOS with a custom photonic integrated circuit fabricated in imec's iSiPP200 silicon photonics platform. The receiver achieves a 3-dB bandwidth of 7.6 GHz, a maximum shot noise clearance of 27 dB, a shot noise-limited bandwidth of 13.7 GHz and a common-mode rejection ratio up to 54.8 dB. These results demonstrate the suitability of CMOS capacitive-feedback transimpedance amplifiers for demanding quantum and coherent sensing optical applications, including continuous-variable quantum key distribution, quantum random number generation, and optical coherence tomography.
Balanced homodyne detector (BHD) that can measure the field quadratures of coherent states has been widely used in a range of quantum information technologies. Generally, the BHD tends to suffer from narrow bands and an expanding bandwidth behavior usually traps into a compromise with the gain, electronic noise, and quantum to classical noise ratio, etc. In this paper, we design and construct a wideband BHD based on radio frequency and integrated circuit technology. Our BHD shows bandwidth behavior up to 1.2 GHz and its quantum to classical noise ratio is around 18 dB. Simultaneously, the BHD has a linear performance with a gain of 4.86 k and its common mode rejection ratio has also been tested as 57.9 dB. With this BHD, the secret key rate of continuous-variable quantum key distribution system has a potential to achieve 66.55 Mb/s and 2.87 Mb/s, respectively, at the transmission distance of 10 and 45 km. Besides, with this BHD, the generation rate of quantum random number generator could reach up to 6.53 Gb/s.
A pulsed, balanced homodyne detector has been developed for precise measurement of the electric field quadratures of pulsed optical quantum states. A high level of common mode suppression (>85 dB) and low electronic noise (730 electrons per pulse) provide a signal-to-noise ratio of 14 dB for measurement of the quantum noise of individual pulses. Measurements at repetition rates as high as 1 MHz are possible. As a test, quantum tomography of the coherent state was performed, and the Wigner function and the density matrix were reconstructed with 99.5% fidelity. The detection system can be used for ultrarsensitive balanced detection in cw mode, e.g., for weak absorption measurements.