Physical Review Letters

Radio-Frequency Magnetometry Based on Parametric Resonances

Wei Xiao, Xiyu Liu, Teng Wu, Xiang Peng, Hong Mei Guo

Published Aug 27, 2024• 24 citations
Publisher

Abstract

We propose and demonstrate a radio-frequency (rf) atomic magnetometer based on parametric resonances. Previously, most rf atomic magnetometers are based on magnetic resonances and their sensitivities are often limited by spin-exchange relaxation. Here, we introduce a novel scheme for an rf magnetometer where the rf magnetic field is measured by exciting the parametric resonances instead of magnetic resonances using parametric modulation fields. In this way, the spin-exchange relaxation is almost eliminated. Benefiting from the low spin relaxation rate, the parametric resonance scheme exhibits a narrower linewidth and stronger signal, which results in a higher sensitivity. With a 6×6×3 mm^{3} Rb atomic vapor cell, we developed an rf atomic magnetometer with a noise floor of 2 fT/Hz^{1/2}, which is about one order of magnitude higher than the sensitivity achieved in the magnetic-resonance-based scheme. The presented rf detection scheme holds promise in advancing rf atomic magnetometers and brings new insight into their various applications.

DOI
10.1103/physrevlett.133.093201

Related papers

Tunable Atomic Magnetometer for Detection of Radio-Frequency Magnetic Fields

Igor Savukov, Scott J. Seltzer, Michael V. Romalis +1 more

We describe an alkali-metal magnetometer for detection of weak magnetic fields in the radio-frequency (rf) range. High sensitivity is achieved by tuning the Zeeman resonance of alkali atoms to the rf frequency and partially suppressing spin-exchange collisions in the alkali-metal vapor. We demonstrate magnetic field sensitivity of 2 fT/Hz(1/2) at a frequency of 99 kHz with a resonance width of 400 Hz. We also derive a simple analytic expression for the fundamental limit on the sensitivity of the rf magnetometer and show that a sensitivity of about 0.01 fT/Hz(1/2) can be achieved in a practical system with a measurement volume of 200 cm3.

Physical Review Letters•Aug 3, 2005•312 citations

Light-narrowed parametric resonance magnetometer with the fundamental sensitivity beyond the spin-exchange limit

Guiying Zhang, Hongjian Zeng, Ruihan Guo +3 more

In the field of biomagnetic measurements, one of the most important recent challenges is to perform measurements in a magnetically unshielded environment. This first requires that atomic magnetometers can operate in a finite magnetic field, and have enough high sensitivity. To meet these requirements, we develop a light-narrowed parametric resonance (LPR) magnetometer. By adding a modulation magnetic field to the large longitudinal magnetic field, our LPR magnetometer can measure small transverse magnetic fields with an intrinsic sensitivity of 3.5 fT/Hz 1/2 in a longitudinal magnetic field of μ T range. Moreover, we have also demonstrated that in contrast to the previous light-narrowed scalar magnetometers, our LPR magnetometer has the potential to achieve higher sensitivity. Because in our case spin-exchange relaxation suppression by using light narrowing can lead to an improvement of fundamental sensitivity limit regardless of which quantum noise is dominant, and hence the fundamental sensitivity is no longer limited by spin-exchange, and approaches the fundamental limit set by the spin-exchange and spin-destruction cross sections.

Optics Letters•Aug 14, 2023•7 citations

Spin-Damping in an Ultra-Sensitive Tunable RF Atomic Magnetometer

Orang Alem

Optically pumped radio frequency (RF) atomic magnetometers have been shown to have an improved sensitivity over standard tuned coils for frequencies less than 50 MHz, making these RF magnetometers attractive for the detection of nuclear quadrupole resonance (NQR) and low-field nuclear magnetic resonance (NMR) signals. In an atomic magnetometer a linearly polarized probe beam measures, through Faraday rotation, the transverse atomic magnetization induced by the resonant RF signal. The resonance, or Larmor, frequency of the magnetometer is easily tuned with a small magnetic field. We construct an atomic magnetometer based on a potassium vapor cell with a measured sensitivity of 0.22 ± 0.02 fT/ √ Hz and a detection bandwidth of 334 ± 11 Hz when tuned to 423 kHz, giving a Q of over 1200. While high Q magnetometers are sensitive to weak magnetic fields, they are also sensitive to magnetic transients, such as those associated with the excitation pulses needed for magnetic resonance. The ringing created by such transients can obscure the signal of interest. This is particularly detrimental for magnetic resonance signals that decay faster than the transverse relaxation rate. We demonstrate that by feeding back part of the optical signal to orthogonal electromagnetic coils, this unwanted ringing can be quickly damped out leaving the magnetometer ready for the detection of the signal. This negative feedback as applied to the K spins is called spin-damping and can be used to relax the K atoms faster by more than two orders of magnitude. Using spin-damping we reduce the dead-time before data acquisition from 0.8 to 0.2 ms in the detection of NQR signals from ammonium nitrate, one of the so-called fertilizer bomb explosives with an NQR frequency of 423 kHz. Furthermore, we discover that spin-damping can not only be used to suppress signals, it can also be used to suppress noise. We show that it can be used to suppress both environmental noise and more fundamental quantum noise, such as photon shot and spin projection noise. The latter suppression opens the door for its use in quantum control to initialize spin systems before measurements. For phase-sensitive detection, as is often used in magnetic resonance, spin-damping suppresses signal and noise in such a way as to increase the sensitivity bandwidth of the magnetometer. We prove, both theoretically and experimentally, that it is possible to increase the magnetometer detection bandwidth by a factor of 3 or more without significant loss in sensitivity. Such gains in bandwidth for a high Q magnetometer translate into savings in detection time, particularly for substance detection where the frequency of the signal of interest may not be completely known.

•Aug 18, 2011•1 citation

All-Optical Parametric-Resonance Magnetometer Based on 4He Atomic Alignment

Bowen Wang, Xiang Peng, Haidong Wang +2 more

Parametric-resonance magnetometer is a high-sensitivity quantum sensor characterized by applying the non-resonant radio-frequency (RF) fields to the atomic ensemble. The RF fields lead to crosstalk in the multi-sensor design, thus disturbing the magnetic-field measurement results. We propose an optically modulated alignment-based 4He parametric-resonance magnetometer. By using the fictitious field generated by the modulated light shift, parametric resonance is realized, and crosstalk caused by the magnetic RF field is prevented. The relative intensity noise of the lasers is suppressed to optimize the sensitivity of the magnetometer. Our magnetometer experimentally demonstrates a magnetic-field noise floor of 130 fT/Hz1/2 in both open- and closed-loop operations and has the potential to reach 70 fT/Hz1/2 when compared with the optimized magnetic RF scheme. It provides near-zero magnetic-field measurements with a 2 kHz bandwidth at room temperature, which is useful for high-bandwidth measurements in biomagnetic applications.

Sensors•May 31, 2022•4 citations

Radio-frequency atomic magnetometers: an analysis of interrogation regimes

Jenelle Rajroop

An atomic magnetometer is a sensor which is used to measure a magnetic field through its interaction with the atomic sample. Significant research into atomic magnetometry has led to the development of very sensitive atomic sensors capable of matching the sensitivity of the most sensitive magnetometers, superconducting quantum interference devices (SQUIDs). Because SQUIDS require cryogenics to operate, atomic magnetometers provide a sensitive, yet low-cost alternative. They have found use in many areas such as medicine, security, explosives detection and fundamental physics research. One of the primary factors influencing sensitivity is the detuning of the probe beam from the resonant transitions of the atomic ground state. A caesium room temperature radio-frequency (rf) magnetometer is constructed and used to investigate the influence of the probe beam detuning on the magnetometer signal of the F = 3 and F = 4 ground states. The results of probing near and far from resonance revealed an off-resonant regime and two absorptive regimes. In the off-resonant regime, the atomic spins are unperturbed by the probe beam; it is a quantum non-demolition (QND) interaction. The two absorptive regimes, found when the probe beam is in the vicinity of either the 62S1 2 F = 3 → 6 2P3 2 F 0 = 2,3,4 or the 62S1 2 F = 4 → 6 2P3 2 F 0 = 3,4,5 transitions, is characterised as a non-QND interaction in which the probe beam influences the measurement. The sensitivity of the rf magnetometer is determined to be ≈ 1.98 fT/ √ Hz. In addition, the exploration of the relationship between the signal to noise ratio (SNR) and probe beam detuning revealed that the SNR is constant with detuning but the larger the detuning, the higher the probe beam power needs to be to reach the optimum SNR.

•Jun 28, 2018•0 citations

Spin-exchange-relaxation-free magnetometry with Cs vapor

M. P. Ledbetter, Igor Savukov, Víctor M. Acosta +2 more

We describe a Cs atomic magnetometer operating in the spin-exchange-relaxation-free (SERF) regime. With a vapor cell temperature of $103\text{ }\ifmmode^\circ\else\textdegree\fi{}\text{C}$ we achieve intrinsic magnetic resonance widths $\ensuremath{\Delta}B=17\text{ }\ensuremath{\mu}\text{G}$ corresponding to an electron spin-relaxation rate of $300\text{ }{\text{s}}^{\ensuremath{-}1}$ when the spin-exchange rate is ${\ensuremath{\Gamma}}_{\text{SE}}=14\text{ }000\text{ }{\text{s}}^{\ensuremath{-}1}$. We also observe an interesting narrowing effect due to diffusion. Signal-to-noise measurements yield a sensitivity of about $400\text{ }\text{pG}/\sqrt{\text{Hz}}$. Based on photon shot noise, we project a sensitivity of $40\text{ }\text{pG}/\sqrt{\text{Hz}}$. A theoretical optimization of the magnetometer indicates sensitivities on the order of $2\text{ }\text{pG}/\sqrt{\text{Hz}}$ should be achievable in a $1\text{ }{\text{cm}}^{3}$ volume. Because Cs has a higher saturated vapor pressure than other alkali metals, SERF magnetometers using Cs atoms are particularly attractive in applications requiring lower temperatures.

arXiv:0708.1012•Physical Review A•Mar 13, 2008•400 citations
We propose and demonstrate a radio-frequency (rf) atomic magnetometer based on parametric resonances. Previously, most rf atomic magnetometers are based on magnetic resonances and their sensitivities are often limited by spin-exchange relaxation. Here, we introduce a novel scheme for an rf magnetometer where the rf magnetic field is measured by exciting the parametric resonances instead of magnetic resonances using parametric modulation fields. In this way, the spin-exchange relaxation is almost eliminated. Benefiting from the low spin relaxation rate, the parametric resonance scheme exhibits a narrower linewidth and stronger signal, which results in a higher sensitivity. With a 6×6×3 mm^{3} Rb atomic vapor cell, we developed an rf atomic magnetometer with a noise floor of 2 fT/Hz^{1/2}, which is about one order of magnitude higher than the sensitivity achieved in the magnetic-resonance-based scheme. The presented rf detection scheme holds promise in advancing rf atomic magnetometers and brings new insight into their various applications.
We describe an alkali-metal magnetometer for detection of weak magnetic fields in the radio-frequency (rf) range. High sensitivity is achieved by tuning the Zeeman resonance of alkali atoms to the rf frequency and partially suppressing spin-exchange collisions in the alkali-metal vapor. We demonstrate magnetic field sensitivity of 2 fT/Hz(1/2) at a frequency of 99 kHz with a resonance width of 400 Hz. We also derive a simple analytic expression for the fundamental limit on the sensitivity of the rf magnetometer and show that a sensitivity of about 0.01 fT/Hz(1/2) can be achieved in a practical system with a measurement volume of 200 cm3.
In the field of biomagnetic measurements, one of the most important recent challenges is to perform measurements in a magnetically unshielded environment. This first requires that atomic magnetometers can operate in a finite magnetic field, and have enough high sensitivity. To meet these requirements, we develop a light-narrowed parametric resonance (LPR) magnetometer. By adding a modulation magnetic field to the large longitudinal magnetic field, our LPR magnetometer can measure small transverse magnetic fields with an intrinsic sensitivity of 3.5 fT/Hz 1/2 in a longitudinal magnetic field of μ T range. Moreover, we have also demonstrated that in contrast to the previous light-narrowed scalar magnetometers, our LPR magnetometer has the potential to achieve higher sensitivity. Because in our case spin-exchange relaxation suppression by using light narrowing can lead to an improvement of fundamental sensitivity limit regardless of which quantum noise is dominant, and hence the fundamental sensitivity is no longer limited by spin-exchange, and approaches the fundamental limit set by the spin-exchange and spin-destruction cross sections.
Optically pumped radio frequency (RF) atomic magnetometers have been shown to have an improved sensitivity over standard tuned coils for frequencies less than 50 MHz, making these RF magnetometers attractive for the detection of nuclear quadrupole resonance (NQR) and low-field nuclear magnetic resonance (NMR) signals. In an atomic magnetometer a linearly polarized probe beam measures, through Faraday rotation, the transverse atomic magnetization induced by the resonant RF signal. The resonance, or Larmor, frequency of the magnetometer is easily tuned with a small magnetic field. We construct an atomic magnetometer based on a potassium vapor cell with a measured sensitivity of 0.22 ± 0.02 fT/ √ Hz and a detection bandwidth of 334 ± 11 Hz when tuned to 423 kHz, giving a Q of over 1200. While high Q magnetometers are sensitive to weak magnetic fields, they are also sensitive to magnetic transients, such as those associated with the excitation pulses needed for magnetic resonance. The ringing created by such transients can obscure the signal of interest. This is particularly detrimental for magnetic resonance signals that decay faster than the transverse relaxation rate. We demonstrate that by feeding back part of the optical signal to orthogonal electromagnetic coils, this unwanted ringing can be quickly damped out leaving the magnetometer ready for the detection of the signal. This negative feedback as applied to the K spins is called spin-damping and can be used to relax the K atoms faster by more than two orders of magnitude. Using spin-damping we reduce the dead-time before data acquisition from 0.8 to 0.2 ms in the detection of NQR signals from ammonium nitrate, one of the so-called fertilizer bomb explosives with an NQR frequency of 423 kHz. Furthermore, we discover that spin-damping can not only be used to suppress signals, it can also be used to suppress noise. We show that it can be used to suppress both environmental noise and more fundamental quantum noise, such as photon shot and spin projection noise. The latter suppression opens the door for its use in quantum control to initialize spin systems before measurements. For phase-sensitive detection, as is often used in magnetic resonance, spin-damping suppresses signal and noise in such a way as to increase the sensitivity bandwidth of the magnetometer. We prove, both theoretically and experimentally, that it is possible to increase the magnetometer detection bandwidth by a factor of 3 or more without significant loss in sensitivity. Such gains in bandwidth for a high Q magnetometer translate into savings in detection time, particularly for substance detection where the frequency of the signal of interest may not be completely known.
Parametric-resonance magnetometer is a high-sensitivity quantum sensor characterized by applying the non-resonant radio-frequency (RF) fields to the atomic ensemble. The RF fields lead to crosstalk in the multi-sensor design, thus disturbing the magnetic-field measurement results. We propose an optically modulated alignment-based 4He parametric-resonance magnetometer. By using the fictitious field generated by the modulated light shift, parametric resonance is realized, and crosstalk caused by the magnetic RF field is prevented. The relative intensity noise of the lasers is suppressed to optimize the sensitivity of the magnetometer. Our magnetometer experimentally demonstrates a magnetic-field noise floor of 130 fT/Hz1/2 in both open- and closed-loop operations and has the potential to reach 70 fT/Hz1/2 when compared with the optimized magnetic RF scheme. It provides near-zero magnetic-field measurements with a 2 kHz bandwidth at room temperature, which is useful for high-bandwidth measurements in biomagnetic applications.
An atomic magnetometer is a sensor which is used to measure a magnetic field through its interaction with the atomic sample. Significant research into atomic magnetometry has led to the development of very sensitive atomic sensors capable of matching the sensitivity of the most sensitive magnetometers, superconducting quantum interference devices (SQUIDs). Because SQUIDS require cryogenics to operate, atomic magnetometers provide a sensitive, yet low-cost alternative. They have found use in many areas such as medicine, security, explosives detection and fundamental physics research. One of the primary factors influencing sensitivity is the detuning of the probe beam from the resonant transitions of the atomic ground state. A caesium room temperature radio-frequency (rf) magnetometer is constructed and used to investigate the influence of the probe beam detuning on the magnetometer signal of the F = 3 and F = 4 ground states. The results of probing near and far from resonance revealed an off-resonant regime and two absorptive regimes. In the off-resonant regime, the atomic spins are unperturbed by the probe beam; it is a quantum non-demolition (QND) interaction. The two absorptive regimes, found when the probe beam is in the vicinity of either the 62S1 2 F = 3 → 6 2P3 2 F 0 = 2,3,4 or the 62S1 2 F = 4 → 6 2P3 2 F 0 = 3,4,5 transitions, is characterised as a non-QND interaction in which the probe beam influences the measurement. The sensitivity of the rf magnetometer is determined to be ≈ 1.98 fT/ √ Hz. In addition, the exploration of the relationship between the signal to noise ratio (SNR) and probe beam detuning revealed that the SNR is constant with detuning but the larger the detuning, the higher the probe beam power needs to be to reach the optimum SNR.
We describe a Cs atomic magnetometer operating in the spin-exchange-relaxation-free (SERF) regime. With a vapor cell temperature of $103\text{ }\ifmmode^\circ\else\textdegree\fi{}\text{C}$ we achieve intrinsic magnetic resonance widths $\ensuremath{\Delta}B=17\text{ }\ensuremath{\mu}\text{G}$ corresponding to an electron spin-relaxation rate of $300\text{ }{\text{s}}^{\ensuremath{-}1}$ when the spin-exchange rate is ${\ensuremath{\Gamma}}_{\text{SE}}=14\text{ }000\text{ }{\text{s}}^{\ensuremath{-}1}$. We also observe an interesting narrowing effect due to diffusion. Signal-to-noise measurements yield a sensitivity of about 400 pG/Hz400\text{ }\text{pG}/\sqrt{\text{Hz}}400 pG/Hz​. Based on photon shot noise, we project a sensitivity of 40 pG/Hz40\text{ }\text{pG}/\sqrt{\text{Hz}}40 pG/Hz​. A theoretical optimization of the magnetometer indicates sensitivities on the order of 2 pG/Hz2\text{ }\text{pG}/\sqrt{\text{Hz}}2 pG/Hz​ should be achievable in a 1 cm31\text{ }{\text{cm}}^{3}1 cm3 volume. Because Cs has a higher saturated vapor pressure than other alkali metals, SERF magnetometers using Cs atoms are particularly attractive in applications requiring lower temperatures.