Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Sensors

All-Optical Parametric-Resonance Magnetometer Based on 4He Atomic Alignment

Bowen Wang, Xiang Peng, Haidong Wang, Wei Xiao, Hong Mei Guo

Published May 31, 2022• 4 citations
Publisher

Abstract

Parametric-resonance magnetometer is a high-sensitivity quantum sensor characterized by applying the non-resonant radio-frequency (RF) fields to the atomic ensemble. The RF fields lead to crosstalk in the multi-sensor design, thus disturbing the magnetic-field measurement results. We propose an optically modulated alignment-based 4He parametric-resonance magnetometer. By using the fictitious field generated by the modulated light shift, parametric resonance is realized, and crosstalk caused by the magnetic RF field is prevented. The relative intensity noise of the lasers is suppressed to optimize the sensitivity of the magnetometer. Our magnetometer experimentally demonstrates a magnetic-field noise floor of 130 fT/Hz1/2 in both open- and closed-loop operations and has the potential to reach 70 fT/Hz1/2 when compared with the optimized magnetic RF scheme. It provides near-zero magnetic-field measurements with a 2 kHz bandwidth at room temperature, which is useful for high-bandwidth measurements in biomagnetic applications.

DOI
10.3390/s22114184

Related papers

Radio-Frequency Magnetometry Based on Parametric Resonances

Wei Xiao, Xiyu Liu, Teng Wu +2 more

We propose and demonstrate a radio-frequency (rf) atomic magnetometer based on parametric resonances. Previously, most rf atomic magnetometers are based on magnetic resonances and their sensitivities are often limited by spin-exchange relaxation. Here, we introduce a novel scheme for an rf magnetometer where the rf magnetic field is measured by exciting the parametric resonances instead of magnetic resonances using parametric modulation fields. In this way, the spin-exchange relaxation is almost eliminated. Benefiting from the low spin relaxation rate, the parametric resonance scheme exhibits a narrower linewidth and stronger signal, which results in a higher sensitivity. With a 6×6×3 mm^{3} Rb atomic vapor cell, we developed an rf atomic magnetometer with a noise floor of 2 fT/Hz^{1/2}, which is about one order of magnitude higher than the sensitivity achieved in the magnetic-resonance-based scheme. The presented rf detection scheme holds promise in advancing rf atomic magnetometers and brings new insight into their various applications.

Physical Review Letters•Aug 27, 2024•24 citations

Three-axis isotropic-sensitivity He4 magnetometer with alignment-based longitudinal parametric resonance

Bowen Wang, Xiang Peng, Wei Xiao +1 more

For measurements in near-zero magnetic fields, vector atomic magnetometers are promising alternatives to scalar versions, but generally suffer from inconsistent performance over three axes. We present a single-beam vector magnetometer with three-axis isotropic sensitivity based on $^{4}\mathrm{He}$ atomic alignment. Longitudinal parametric resonance with atoms pumped by linearly polarized light is proposed for the $z$-axis measurement, while the Hanle effect in transverse geometry is used for $x$- and $y$-axis measurements. The evolution of atomic alignment multipole components and expressions of the three-axis magnetic responses are analyzed in detail. We describe the experimental operation of the proposed magnetometer with a magnetic-field noise floor of $150\phantom{\rule{0.16em}{0ex}}\mathrm{fT}/{\mathrm{Hz}}^{1/2}$ for the three axes, which is attractive for biomagnetism requiring vector characterization and source reconstruction.

Physical Review A•Dec 12, 2022•6 citations

Light-narrowed parametric resonance magnetometer with the fundamental sensitivity beyond the spin-exchange limit

Guiying Zhang, Hongjian Zeng, Ruihan Guo +3 more

In the field of biomagnetic measurements, one of the most important recent challenges is to perform measurements in a magnetically unshielded environment. This first requires that atomic magnetometers can operate in a finite magnetic field, and have enough high sensitivity. To meet these requirements, we develop a light-narrowed parametric resonance (LPR) magnetometer. By adding a modulation magnetic field to the large longitudinal magnetic field, our LPR magnetometer can measure small transverse magnetic fields with an intrinsic sensitivity of 3.5 fT/Hz 1/2 in a longitudinal magnetic field of μ T range. Moreover, we have also demonstrated that in contrast to the previous light-narrowed scalar magnetometers, our LPR magnetometer has the potential to achieve higher sensitivity. Because in our case spin-exchange relaxation suppression by using light narrowing can lead to an improvement of fundamental sensitivity limit regardless of which quantum noise is dominant, and hence the fundamental sensitivity is no longer limited by spin-exchange, and approaches the fundamental limit set by the spin-exchange and spin-destruction cross sections.

Optics Letters•Aug 14, 2023•7 citations

Laser pumped 4He magnetometer with light shift suppression

Zaisheng Lin, He Wang, Xiang Peng +2 more

We report a laser-pumped 4He atomic magnetometer with light shift suppression through the atomic sensor itself. A linearly polarized light is used to optically align the 4He metastable atoms and we monitor the magneto-optical double resonance (MODR) signals produced by the left- and right-circularly orthogonal components. It is shown that light shift leads to the atomic alignment to orientation conversion effect, and thus, the difference between the two MODR signals. One of these two MODR signals is locked at the Larmor frequency and is used to measure the ambient magnetic field, while the differential signal is, simultaneously, fed back to suppress the light shift. The scheme could be of the advantage to the design of compact magnetometers by reducing the systematic errors due to light shift.

Review of Scientific Instruments•Nov 1, 2016•6 citations

An optically modulated zero-field atomic magnetometer with suppressed spin-exchange broadening

Ricardo Jiménez-Martínez, Svenja A. Knappe, John E. Kitching

We demonstrate an optically pumped (87)Rb magnetometer in a microfabricated vapor cell based on a zero-field dispersive resonance generated by optical modulation of the (87)Rb ground state energy levels. The magnetometer is operated in the spin-exchange relaxation-free regime where high magnetic field sensitivities can be achieved. This device can be useful in applications requiring array-based magnetometers where radio frequency magnetic fields can induce cross-talk among adjacent sensors or affect the source of the magnetic field being measured.

arXiv:1404.0374•Review of Scientific Instruments•Apr 1, 2014•51 citations

Room temperature femtotesla radio-frequency atomic magnetometer

Witold Chałupczak, R. M. Godun, Szymon Pustelny +1 more

A radio-frequency tunable atomic magnetometer with a sensitivity of about 1 fT/Hz1/2 in a range of 10–500 kHz is demonstrated. The magnetometer is operated in the orientation configuration in which atoms are pumped to the stretched atomic state by a scheme based on indirect optical pumping using only one unmodulated, low-power laser. The magnetometer operates with cesium atoms, which have sufficient vapor pressure near room temperature to enable high magnetometric sensitivities. The technique enables a compact and robust module to be constructed that could become an in-the-field device.

Applied Physics Letters•Jun 11, 2012•87 citations
Parametric-resonance magnetometer is a high-sensitivity quantum sensor characterized by applying the non-resonant radio-frequency (RF) fields to the atomic ensemble. The RF fields lead to crosstalk in the multi-sensor design, thus disturbing the magnetic-field measurement results. We propose an optically modulated alignment-based 4He parametric-resonance magnetometer. By using the fictitious field generated by the modulated light shift, parametric resonance is realized, and crosstalk caused by the magnetic RF field is prevented. The relative intensity noise of the lasers is suppressed to optimize the sensitivity of the magnetometer. Our magnetometer experimentally demonstrates a magnetic-field noise floor of 130 fT/Hz1/2 in both open- and closed-loop operations and has the potential to reach 70 fT/Hz1/2 when compared with the optimized magnetic RF scheme. It provides near-zero magnetic-field measurements with a 2 kHz bandwidth at room temperature, which is useful for high-bandwidth measurements in biomagnetic applications.
We propose and demonstrate a radio-frequency (rf) atomic magnetometer based on parametric resonances. Previously, most rf atomic magnetometers are based on magnetic resonances and their sensitivities are often limited by spin-exchange relaxation. Here, we introduce a novel scheme for an rf magnetometer where the rf magnetic field is measured by exciting the parametric resonances instead of magnetic resonances using parametric modulation fields. In this way, the spin-exchange relaxation is almost eliminated. Benefiting from the low spin relaxation rate, the parametric resonance scheme exhibits a narrower linewidth and stronger signal, which results in a higher sensitivity. With a 6×6×3 mm^{3} Rb atomic vapor cell, we developed an rf atomic magnetometer with a noise floor of 2 fT/Hz^{1/2}, which is about one order of magnitude higher than the sensitivity achieved in the magnetic-resonance-based scheme. The presented rf detection scheme holds promise in advancing rf atomic magnetometers and brings new insight into their various applications.
For measurements in near-zero magnetic fields, vector atomic magnetometers are promising alternatives to scalar versions, but generally suffer from inconsistent performance over three axes. We present a single-beam vector magnetometer with three-axis isotropic sensitivity based on 4He^{4}\mathrm{He}4He atomic alignment. Longitudinal parametric resonance with atoms pumped by linearly polarized light is proposed for the zzz-axis measurement, while the Hanle effect in transverse geometry is used for xxx- and yyy-axis measurements. The evolution of atomic alignment multipole components and expressions of the three-axis magnetic responses are analyzed in detail. We describe the experimental operation of the proposed magnetometer with a magnetic-field noise floor of 150fT/Hz1/2150\phantom{\rule{0.16em}{0ex}}\mathrm{fT}/{\mathrm{Hz}}^{1/2}150fT/Hz1/2 for the three axes, which is attractive for biomagnetism requiring vector characterization and source reconstruction.
In the field of biomagnetic measurements, one of the most important recent challenges is to perform measurements in a magnetically unshielded environment. This first requires that atomic magnetometers can operate in a finite magnetic field, and have enough high sensitivity. To meet these requirements, we develop a light-narrowed parametric resonance (LPR) magnetometer. By adding a modulation magnetic field to the large longitudinal magnetic field, our LPR magnetometer can measure small transverse magnetic fields with an intrinsic sensitivity of 3.5 fT/Hz 1/2 in a longitudinal magnetic field of μ T range. Moreover, we have also demonstrated that in contrast to the previous light-narrowed scalar magnetometers, our LPR magnetometer has the potential to achieve higher sensitivity. Because in our case spin-exchange relaxation suppression by using light narrowing can lead to an improvement of fundamental sensitivity limit regardless of which quantum noise is dominant, and hence the fundamental sensitivity is no longer limited by spin-exchange, and approaches the fundamental limit set by the spin-exchange and spin-destruction cross sections.
We report a laser-pumped 4He atomic magnetometer with light shift suppression through the atomic sensor itself. A linearly polarized light is used to optically align the 4He metastable atoms and we monitor the magneto-optical double resonance (MODR) signals produced by the left- and right-circularly orthogonal components. It is shown that light shift leads to the atomic alignment to orientation conversion effect, and thus, the difference between the two MODR signals. One of these two MODR signals is locked at the Larmor frequency and is used to measure the ambient magnetic field, while the differential signal is, simultaneously, fed back to suppress the light shift. The scheme could be of the advantage to the design of compact magnetometers by reducing the systematic errors due to light shift.
We demonstrate an optically pumped (87)Rb magnetometer in a microfabricated vapor cell based on a zero-field dispersive resonance generated by optical modulation of the (87)Rb ground state energy levels. The magnetometer is operated in the spin-exchange relaxation-free regime where high magnetic field sensitivities can be achieved. This device can be useful in applications requiring array-based magnetometers where radio frequency magnetic fields can induce cross-talk among adjacent sensors or affect the source of the magnetic field being measured.
A radio-frequency tunable atomic magnetometer with a sensitivity of about 1 fT/Hz1/2 in a range of 10–500 kHz is demonstrated. The magnetometer is operated in the orientation configuration in which atoms are pumped to the stretched atomic state by a scheme based on indirect optical pumping using only one unmodulated, low-power laser. The magnetometer operates with cesium atoms, which have sufficient vapor pressure near room temperature to enable high magnetometric sensitivities. The technique enables a compact and robust module to be constructed that could become an in-the-field device.