Physical Review Applied

Femtotesla triaxial 4 He magnetometer via parametric resonance

Zejia Lin, Kaiwen Yi, Zixuan Xiao, Teng Wu, Xiang Peng, Hong Guo

Published Nov 3, 2026• 0 citations
Publisher

Abstract

We demonstrate a vector magnetometer based on parametric resonance, featuring a compact field configuration that requires only a linearly polarized optical beam and a radio-frequency (RF) field. The transverse components are measured simultaneously, followed by determination of the longitudinal component via a time-multiplexed application of a bias field, thereby achieving triaxial sensing. Validated experimentally and supported by theoretical modeling, the magnetometer operates at room temperature using spin-aligned metastable 4 He atoms, achieving kHz-scale bandwidth and directional sensitivities of 7 , 16 , and 24 f T / H z along the three orthogonal axes. Such a configuration circumvents the inherent sensitivity degradation and complexity typical of multi-beam or multi-RF-field schemes, offering a compact yet high-performance platform for vector magnetometry. Our work facilitates the miniaturization of vector magnetometers and supports advanced applications such as magnetic source localization and magnetic field imaging.

DOI
10.1103/y8zx-tj5m

Related papers

Three-axis isotropic-sensitivity He4 magnetometer with alignment-based longitudinal parametric resonance

Bowen Wang, Xiang Peng, Wei Xiao +1 more

For measurements in near-zero magnetic fields, vector atomic magnetometers are promising alternatives to scalar versions, but generally suffer from inconsistent performance over three axes. We present a single-beam vector magnetometer with three-axis isotropic sensitivity based on $^{4}\mathrm{He}$ atomic alignment. Longitudinal parametric resonance with atoms pumped by linearly polarized light is proposed for the $z$-axis measurement, while the Hanle effect in transverse geometry is used for $x$- and $y$-axis measurements. The evolution of atomic alignment multipole components and expressions of the three-axis magnetic responses are analyzed in detail. We describe the experimental operation of the proposed magnetometer with a magnetic-field noise floor of $150\phantom{\rule{0.16em}{0ex}}\mathrm{fT}/{\mathrm{Hz}}^{1/2}$ for the three axes, which is attractive for biomagnetism requiring vector characterization and source reconstruction.

Physical Review A•Dec 12, 2022•6 citations

Triaxial Vector Operation in Near-Zero Field of Atomic Magnetometer With Femtotesla Sensitivity

Fei Lu, Jixi Lu, Bo Li +5 more

Compact atomic magnetometer has become an important approach for noise measurement of magnetic shielding systems as well as biomagnetic measurement. In this study, we propose a novel method that enables time-shard triaxial magnetic field measurements in near-zero magnetic field through a compact high-performance atomic magnetometer with femtotesla sensitivity. With pump–probe orthogonal configuration, the magnetometer can be operated without optical and magnetic modulation. They-axis magnetic field measurement was realized in zero field, whereas thex- andz- axes magnetic fields were measured by the cross-application of the bias magnetic fields operating in near-zero field. The maximum response amplitude and sensitivity with bandwidths of 46.8 Hz (x- axis), 10.5 Hz (y-axis), and 10.9 Hz (z-axis) are achieved under bias magnetic fields of$B_{z-\mathrm {offset}}= 8$nT and$B_{x-\mathrm {offset}} = 2$nT. The bandwidth alongx- axis was extended to 232 Hz under$B_{z-\mathrm {offset}} = 32$nT, which can further be improved by increasing$B_{z-\mathrm {offset}}$. The linear interval of measurable magnetic field are between −11.7 to +11.7 nT (x- axis), −0.8 to +0.8 nT (y-axis), and −28.2 to +28.2 nT (z-axis). Forx- andz-axes, the measurable interval can further be improved by increasing$B_{z-\mathrm {offset}}$and$B_{x-\mathrm {offset}}$, respectively. The triaxial sensitivities achieved through our method reached 3.1 ± 0.3 fT/Hz1/2(x- axis), 2.0 ± 0.1 fT/Hz1/2(y- axis), and 6.0 ± 0.5 fT/Hz1/2(z- axis). This system is measured in a low-noise ferrite magnetic shield to ensure extra-low magnetic noise condition. Furthermore, the non-modulation triaxial vector operation demonstrated in this study is advantageous for reducing interference and spin-exchange relaxation caused by magnetic field modulation.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2022•27 citations

All-Optical Parametric-Resonance Magnetometer Based on 4He Atomic Alignment

Bowen Wang, Xiang Peng, Haidong Wang +2 more

Parametric-resonance magnetometer is a high-sensitivity quantum sensor characterized by applying the non-resonant radio-frequency (RF) fields to the atomic ensemble. The RF fields lead to crosstalk in the multi-sensor design, thus disturbing the magnetic-field measurement results. We propose an optically modulated alignment-based 4He parametric-resonance magnetometer. By using the fictitious field generated by the modulated light shift, parametric resonance is realized, and crosstalk caused by the magnetic RF field is prevented. The relative intensity noise of the lasers is suppressed to optimize the sensitivity of the magnetometer. Our magnetometer experimentally demonstrates a magnetic-field noise floor of 130 fT/Hz1/2 in both open- and closed-loop operations and has the potential to reach 70 fT/Hz1/2 when compared with the optimized magnetic RF scheme. It provides near-zero magnetic-field measurements with a 2 kHz bandwidth at room temperature, which is useful for high-bandwidth measurements in biomagnetic applications.

Sensors•May 31, 2022•4 citations

Triaxial Alignment Magnetometer Utilizing Free-Spin Precession in the Geomagnetic Range

Jin, Ge, Tao Shi, Sheng Zou

In this paper, we present a triaxial alignment magnetometer based on free-spin precession deployed in the geomagnetic range. Existing vector measurement methods often require complex optical setups, heating structures, and laser modulation. This study addresses this challenge by employing a linearly polarized probe beam to induce atomic alignment and subsequently detecting the optical polarization rotation caused by the pulsed radio frequency field. The experiment is conducted in a paraffin-coated cell without buffer gas at room temperature, containing rubidium with natural abundance. We report triaxial measurements with a static magnetic field amplitude of approximately 50 $μ{\text{T}}$ (close to Earth's magnetic field), where the noise levels for each axis are approximately 5.3 ${\text{pT/}}\sqrt{\text{Hz}}$, 4.7 ${\text{pT/}}\sqrt{\text{Hz}}$, and 9.3 ${\text{pT/}}\sqrt{\text{Hz}}$ respectively. The proposed method demonstrates a simple structure suitable for cost-effective and versatile applications.

arXiv:2502.11512•Feb 17, 2025•0 citations

Single-beam triaxial spin-exchange relaxation-free atomic magnetometer utilizing transverse modulation fields

Lin Li, Junjian Tang, Binbin Zhao +3 more

We display a single-beam triaxial spin-exchange relaxation-free (SERF) atomic magnetometer by utilizing two orthogonal transverse modulation fields perpendicular to the light. The magnetic field’s three-axis vector components can be extracted simultaneously and independently from the transmitted light by lock-in amplifiers with reference to the different demodulated frequencies. We find that the residual magnetic field is a significant factor that could affect triaxial coupling, and specially the influence of the z -axis remanence on xy -axis coupling is studied in detail. Under the optimal parameters, the three-axis sensitivities are 20 fT Hz − 1 / 2 in the x - and y - axis, and 230 fT Hz − 1 / 2 in the z -axis. Meanwhile, the three-axis bandwidths are 110 Hz, 138 Hz and 211 Hz in the x -, y - and z -axis, respectively. The proposed single-beam triaxial SERF atomic magnetometer could be used to construct a compact and low-cost atomic sensor that is particularly suitable for the vector measurement of the biomagnetic such as magnetoencephalography and magnetocardiography.

Journal of Physics D Applied Physics•Nov 2, 2022•23 citations

Room temperature femtotesla radio-frequency atomic magnetometer

Witold Chałupczak, R. M. Godun, Szymon Pustelny +1 more

A radio-frequency tunable atomic magnetometer with a sensitivity of about 1 fT/Hz1/2 in a range of 10–500 kHz is demonstrated. The magnetometer is operated in the orientation configuration in which atoms are pumped to the stretched atomic state by a scheme based on indirect optical pumping using only one unmodulated, low-power laser. The magnetometer operates with cesium atoms, which have sufficient vapor pressure near room temperature to enable high magnetometric sensitivities. The technique enables a compact and robust module to be constructed that could become an in-the-field device.

Applied Physics Letters•Jun 11, 2012•88 citations
We demonstrate a vector magnetometer based on parametric resonance, featuring a compact field configuration that requires only a linearly polarized optical beam and a radio-frequency (RF) field. The transverse components are measured simultaneously, followed by determination of the longitudinal component via a time-multiplexed application of a bias field, thereby achieving triaxial sensing. Validated experimentally and supported by theoretical modeling, the magnetometer operates at room temperature using spin-aligned metastable 4 He atoms, achieving kHz-scale bandwidth and directional sensitivities of 7 , 16 , and 24 f T / H z along the three orthogonal axes. Such a configuration circumvents the inherent sensitivity degradation and complexity typical of multi-beam or multi-RF-field schemes, offering a compact yet high-performance platform for vector magnetometry. Our work facilitates the miniaturization of vector magnetometers and supports advanced applications such as magnetic source localization and magnetic field imaging.
For measurements in near-zero magnetic fields, vector atomic magnetometers are promising alternatives to scalar versions, but generally suffer from inconsistent performance over three axes. We present a single-beam vector magnetometer with three-axis isotropic sensitivity based on 4He^{4}\mathrm{He}4He atomic alignment. Longitudinal parametric resonance with atoms pumped by linearly polarized light is proposed for the zzz-axis measurement, while the Hanle effect in transverse geometry is used for xxx- and yyy-axis measurements. The evolution of atomic alignment multipole components and expressions of the three-axis magnetic responses are analyzed in detail. We describe the experimental operation of the proposed magnetometer with a magnetic-field noise floor of 150fT/Hz1/2150\phantom{\rule{0.16em}{0ex}}\mathrm{fT}/{\mathrm{Hz}}^{1/2}150fT/Hz1/2 for the three axes, which is attractive for biomagnetism requiring vector characterization and source reconstruction.
Compact atomic magnetometer has become an important approach for noise measurement of magnetic shielding systems as well as biomagnetic measurement. In this study, we propose a novel method that enables time-shard triaxial magnetic field measurements in near-zero magnetic field through a compact high-performance atomic magnetometer with femtotesla sensitivity. With pump–probe orthogonal configuration, the magnetometer can be operated without optical and magnetic modulation. They-axis magnetic field measurement was realized in zero field, whereas thex- andz- axes magnetic fields were measured by the cross-application of the bias magnetic fields operating in near-zero field. The maximum response amplitude and sensitivity with bandwidths of 46.8 Hz (x- axis), 10.5 Hz (y-axis), and 10.9 Hz (z-axis) are achieved under bias magnetic fields ofBz−offset=8B_{z-\mathrm {offset}}= 8Bz−offset​=8nT andBx−offset=2B_{x-\mathrm {offset}} = 2Bx−offset​=2nT. The bandwidth alongx- axis was extended to 232 Hz underBz−offset=32B_{z-\mathrm {offset}} = 32Bz−offset​=32nT, which can further be improved by increasingBz−offsetB_{z-\mathrm {offset}}Bz−offset​. The linear interval of measurable magnetic field are between −11.7 to +11.7 nT (x- axis), −0.8 to +0.8 nT (y-axis), and −28.2 to +28.2 nT (z-axis). Forx- andz-axes, the measurable interval can further be improved by increasingBz−offsetB_{z-\mathrm {offset}}Bz−offset​andBx−offsetB_{x-\mathrm {offset}}Bx−offset​, respectively. The triaxial sensitivities achieved through our method reached 3.1 ± 0.3 fT/Hz1/2(x- axis), 2.0 ± 0.1 fT/Hz1/2(y- axis), and 6.0 ± 0.5 fT/Hz1/2(z- axis). This system is measured in a low-noise ferrite magnetic shield to ensure extra-low magnetic noise condition. Furthermore, the non-modulation triaxial vector operation demonstrated in this study is advantageous for reducing interference and spin-exchange relaxation caused by magnetic field modulation.
Parametric-resonance magnetometer is a high-sensitivity quantum sensor characterized by applying the non-resonant radio-frequency (RF) fields to the atomic ensemble. The RF fields lead to crosstalk in the multi-sensor design, thus disturbing the magnetic-field measurement results. We propose an optically modulated alignment-based 4He parametric-resonance magnetometer. By using the fictitious field generated by the modulated light shift, parametric resonance is realized, and crosstalk caused by the magnetic RF field is prevented. The relative intensity noise of the lasers is suppressed to optimize the sensitivity of the magnetometer. Our magnetometer experimentally demonstrates a magnetic-field noise floor of 130 fT/Hz1/2 in both open- and closed-loop operations and has the potential to reach 70 fT/Hz1/2 when compared with the optimized magnetic RF scheme. It provides near-zero magnetic-field measurements with a 2 kHz bandwidth at room temperature, which is useful for high-bandwidth measurements in biomagnetic applications.
In this paper, we present a triaxial alignment magnetometer based on free-spin precession deployed in the geomagnetic range. Existing vector measurement methods often require complex optical setups, heating structures, and laser modulation. This study addresses this challenge by employing a linearly polarized probe beam to induce atomic alignment and subsequently detecting the optical polarization rotation caused by the pulsed radio frequency field. The experiment is conducted in a paraffin-coated cell without buffer gas at room temperature, containing rubidium with natural abundance. We report triaxial measurements with a static magnetic field amplitude of approximately 50 μTμ{\text{T}}μT (close to Earth's magnetic field), where the noise levels for each axis are approximately 5.3 pT/Hz{\text{pT/}}\sqrt{\text{Hz}}pT/Hz​, 4.7 pT/Hz{\text{pT/}}\sqrt{\text{Hz}}pT/Hz​, and 9.3 pT/Hz{\text{pT/}}\sqrt{\text{Hz}}pT/Hz​ respectively. The proposed method demonstrates a simple structure suitable for cost-effective and versatile applications.
We display a single-beam triaxial spin-exchange relaxation-free (SERF) atomic magnetometer by utilizing two orthogonal transverse modulation fields perpendicular to the light. The magnetic field’s three-axis vector components can be extracted simultaneously and independently from the transmitted light by lock-in amplifiers with reference to the different demodulated frequencies. We find that the residual magnetic field is a significant factor that could affect triaxial coupling, and specially the influence of the z -axis remanence on xy -axis coupling is studied in detail. Under the optimal parameters, the three-axis sensitivities are 20 fT Hz − 1 / 2 in the x - and y - axis, and 230 fT Hz − 1 / 2 in the z -axis. Meanwhile, the three-axis bandwidths are 110 Hz, 138 Hz and 211 Hz in the x -, y - and z -axis, respectively. The proposed single-beam triaxial SERF atomic magnetometer could be used to construct a compact and low-cost atomic sensor that is particularly suitable for the vector measurement of the biomagnetic such as magnetoencephalography and magnetocardiography.
A radio-frequency tunable atomic magnetometer with a sensitivity of about 1 fT/Hz1/2 in a range of 10–500 kHz is demonstrated. The magnetometer is operated in the orientation configuration in which atoms are pumped to the stretched atomic state by a scheme based on indirect optical pumping using only one unmodulated, low-power laser. The magnetometer operates with cesium atoms, which have sufficient vapor pressure near room temperature to enable high magnetometric sensitivities. The technique enables a compact and robust module to be constructed that could become an in-the-field device.