IEEE Transactions on Instrumentation and Measurement

Triaxial Vector Operation in Near-Zero Field of Atomic Magnetometer With Femtotesla Sensitivity

Fei Lu, Jixi Lu, Bo Li, Yeguang Yan, Shaowen Zhang, Kaifeng Yin, Mao Ye, Bangcheng Han

Published Jan 1, 2022• 27 citations
Publisher

Abstract

Compact atomic magnetometer has become an important approach for noise measurement of magnetic shielding systems as well as biomagnetic measurement. In this study, we propose a novel method that enables time-shard triaxial magnetic field measurements in near-zero magnetic field through a compact high-performance atomic magnetometer with femtotesla sensitivity. With pump–probe orthogonal configuration, the magnetometer can be operated without optical and magnetic modulation. They-axis magnetic field measurement was realized in zero field, whereas thex- andz- axes magnetic fields were measured by the cross-application of the bias magnetic fields operating in near-zero field. The maximum response amplitude and sensitivity with bandwidths of 46.8 Hz (x- axis), 10.5 Hz (y-axis), and 10.9 Hz (z-axis) are achieved under bias magnetic fields of$B_{z-\mathrm {offset}}= 8$nT and$B_{x-\mathrm {offset}} = 2$nT. The bandwidth alongx- axis was extended to 232 Hz under$B_{z-\mathrm {offset}} = 32$nT, which can further be improved by increasing$B_{z-\mathrm {offset}}$. The linear interval of measurable magnetic field are between −11.7 to +11.7 nT (x- axis), −0.8 to +0.8 nT (y-axis), and −28.2 to +28.2 nT (z-axis). Forx- andz-axes, the measurable interval can further be improved by increasing$B_{z-\mathrm {offset}}$and$B_{x-\mathrm {offset}}$, respectively. The triaxial sensitivities achieved through our method reached 3.1 ± 0.3 fT/Hz1/2(x- axis), 2.0 ± 0.1 fT/Hz1/2(y- axis), and 6.0 ± 0.5 fT/Hz1/2(z- axis). This system is measured in a low-noise ferrite magnetic shield to ensure extra-low magnetic noise condition. Furthermore, the non-modulation triaxial vector operation demonstrated in this study is advantageous for reducing interference and spin-exchange relaxation caused by magnetic field modulation.

DOI
10.1109/tim.2022.3162282

Related papers

Single-beam triaxial spin-exchange relaxation-free atomic magnetometer utilizing transverse modulation fields

Lin Li, Junjian Tang, Binbin Zhao +3 more

We display a single-beam triaxial spin-exchange relaxation-free (SERF) atomic magnetometer by utilizing two orthogonal transverse modulation fields perpendicular to the light. The magnetic field’s three-axis vector components can be extracted simultaneously and independently from the transmitted light by lock-in amplifiers with reference to the different demodulated frequencies. We find that the residual magnetic field is a significant factor that could affect triaxial coupling, and specially the influence of the z -axis remanence on xy -axis coupling is studied in detail. Under the optimal parameters, the three-axis sensitivities are 20 fT Hz − 1 / 2 in the x - and y - axis, and 230 fT Hz − 1 / 2 in the z -axis. Meanwhile, the three-axis bandwidths are 110 Hz, 138 Hz and 211 Hz in the x -, y - and z -axis, respectively. The proposed single-beam triaxial SERF atomic magnetometer could be used to construct a compact and low-cost atomic sensor that is particularly suitable for the vector measurement of the biomagnetic such as magnetoencephalography and magnetocardiography.

Journal of Physics D Applied Physics•Nov 2, 2022•23 citations

基于交叉偏置磁场的单光束三轴原子磁力仪

吴梓楠 Wu Zinan, 张佳龙 Zhang Jialong, 何孟阳 He Mengyang +6 more

We report a single-beam triaxial atomic magnetometer based on cross bias magnetic field. Based on Bloch equation, the theory of single-beam scheme to achieve triaxial magnetic field detection is studied. To achieve triaxial magnetic field detection, the method of using cross bias magnetic field to rotate the atomic spin polarization direction is proposed and experimentally verified. By using only one single modulation magnetic field, it is possible to suppress low frequency noise and avoid the problem of magnetic field cross-talk. The experimental results show that the system response bandwidth to the magnetic field along X-axis is 90 Hz and the system sensitivity is 21 fT/(Hz1/2) under the zero-field condition. The system response bandwidth to the magnetic field along Y-axis is 130 Hz and the system sensitivity is 26 fT/(Hz1/2) when a bias magnetic field of 34 nT is applied in the Z-axis. The system response bandwidth to the magnetic field along Z-axis is 128 Hz and the system sensitivity is 29 fT/(Hz1/2) when a bias magnetic field of 38 nT is applied in the Y-axis. The proposed triaxial atomic magnetometer has the advantages of small size, simple structure and low fabrication cost, and is expected to be used in the biomedical and other fields.

Laser & Optoelectronics Progress•Jan 1, 2024•0 citations

Static bias magnetic field assisted optical modulation triaxial SERF atomic magnetometer

Xiaoyu Li, Bangcheng Han, Shushan Gao +4 more

High-sensitivity triaxial magnetic field measurements are crucial in various scientific and industrial applications, with spin-exchange relaxation-free (SERF) atomic magnetometers (AMs) standing out for their exceptional sensitivity. However, conventional methods for achieving triaxial measurements in SERF magnetometers typically involve multiple modulated magnetic fields, which introduce crosstalk challenges in array-based configurations. We propose a static bias magnetic field assisted optical modulation triaxial AM to address this limitation. In this configuration, the detuned circularly polarized light is utilized to achieve synchronous modulation of the fictitious magnetic field and pumping rate while incorporating a static bias magnetic field to generate a transverse projection component. We develop a comprehensive triaxial response model that fully considers the effects of the longitudinal spin polarization deflection. Building upon this model, we derive the relationship between the transverse spin component and the triaxial magnetic field and introduce parameter optimization methods to obtain optimal parameters, thus enabling triaxial measurements of 12 fT Hz −1/2 , 10 fT Hz −1/2 , and 15 fT Hz −1/2 along the x-, y -, and z -axes. Our approach offers significant advantages over existing methods, particularly in minimizing crosstalk and mitigating spin-exchange relaxation introduced by multiple modulated magnetic fields. Moreover, the effective detection of simulated magnetocardiography signals highlights the practical applicability and reliability of the proposed method in real-world scenarios.

Measurement Science and Technology•Nov 18, 2025•3 citations

In situ triaxial magnetic field compensation for the spin-exchange-relaxation-free atomic magnetometer

Jiancheng Fang, Jie Qin

The spin-exchange-relaxation-free (SERF) atomic magnetometer is an ultra-high sensitivity magnetometer, but it must be operated in a magnetic field with strength less than about 10 nT. Magnetic field compensation is an effective way to shield the magnetic field, and this paper demonstrates an in situ triaxial magnetic field compensation system for operating the SERF atomic magnetometer. The proposed hardware is based on optical pumping, which uses some part of the SERF atomic magnetometer itself, and the compensation method is implemented by analyzing the dynamics of the atomic spin. The experimental setup for this compensation system is described, and with this configuration, a residual magnetic field of strength less than 2 nT (±0.38 nT in the x axis, ±0.43 nT in the y axis, and ±1.62 nT in the z axis) has been achieved after compensation. The SERF atomic magnetometer was then used to verify that the residual triaxial magnetic fields were coincident with what were achieved by the compensation system.

Review of Scientific Instruments•Oct 1, 2012•74 citations

Femtotesla triaxial 4 He magnetometer via parametric resonance

Zejia Lin, Kaiwen Yi, Zixuan Xiao +3 more

We demonstrate a vector magnetometer based on parametric resonance, featuring a compact field configuration that requires only a linearly polarized optical beam and a radio-frequency (RF) field. The transverse components are measured simultaneously, followed by determination of the longitudinal component via a time-multiplexed application of a bias field, thereby achieving triaxial sensing. Validated experimentally and supported by theoretical modeling, the magnetometer operates at room temperature using spin-aligned metastable 4 He atoms, achieving kHz-scale bandwidth and directional sensitivities of 7 , 16 , and 24 f T / H z along the three orthogonal axes. Such a configuration circumvents the inherent sensitivity degradation and complexity typical of multi-beam or multi-RF-field schemes, offering a compact yet high-performance platform for vector magnetometry. Our work facilitates the miniaturization of vector magnetometers and supports advanced applications such as magnetic source localization and magnetic field imaging.

Physical Review Applied•Nov 3, 2026•0 citations

Single-beam three-axis atomic magnetometer

Haichao Huang, Haifeng Dong, Lin Chen +1 more

A single-beam atomic magnetometer being operated near zero-field and measuring three-axis fields simultaneously is demonstrated. We produce a rotating field on the x-0-y plane with the frequency of 90 Hz and a modulation field in the z axis at 130 Hz. The rotating field enables a nonzero z axis output when the transverse fields are zeroed using feedback systems. Based on the phase difference of π/2, x and y axes fields can be measured using one lock-in amplifier. Magnetic field sensitivities of 300 fT/Hz1∕2 in x and y axes and 3 pT/Hz1∕2 in the z axis are achieved.

Applied Physics Letters•Aug 8, 2016•79 citations
Compact atomic magnetometer has become an important approach for noise measurement of magnetic shielding systems as well as biomagnetic measurement. In this study, we propose a novel method that enables time-shard triaxial magnetic field measurements in near-zero magnetic field through a compact high-performance atomic magnetometer with femtotesla sensitivity. With pump–probe orthogonal configuration, the magnetometer can be operated without optical and magnetic modulation. They-axis magnetic field measurement was realized in zero field, whereas thex- andz- axes magnetic fields were measured by the cross-application of the bias magnetic fields operating in near-zero field. The maximum response amplitude and sensitivity with bandwidths of 46.8 Hz (x- axis), 10.5 Hz (y-axis), and 10.9 Hz (z-axis) are achieved under bias magnetic fields ofBz−offset=8B_{z-\mathrm {offset}}= 8Bz−offset​=8nT andBx−offset=2B_{x-\mathrm {offset}} = 2Bx−offset​=2nT. The bandwidth alongx- axis was extended to 232 Hz underBz−offset=32B_{z-\mathrm {offset}} = 32Bz−offset​=32nT, which can further be improved by increasingBz−offsetB_{z-\mathrm {offset}}Bz−offset​. The linear interval of measurable magnetic field are between −11.7 to +11.7 nT (x- axis), −0.8 to +0.8 nT (y-axis), and −28.2 to +28.2 nT (z-axis). Forx- andz-axes, the measurable interval can further be improved by increasingBz−offsetB_{z-\mathrm {offset}}Bz−offset​andBx−offsetB_{x-\mathrm {offset}}Bx−offset​, respectively. The triaxial sensitivities achieved through our method reached 3.1 ± 0.3 fT/Hz1/2(x- axis), 2.0 ± 0.1 fT/Hz1/2(y- axis), and 6.0 ± 0.5 fT/Hz1/2(z- axis). This system is measured in a low-noise ferrite magnetic shield to ensure extra-low magnetic noise condition. Furthermore, the non-modulation triaxial vector operation demonstrated in this study is advantageous for reducing interference and spin-exchange relaxation caused by magnetic field modulation.
We display a single-beam triaxial spin-exchange relaxation-free (SERF) atomic magnetometer by utilizing two orthogonal transverse modulation fields perpendicular to the light. The magnetic field’s three-axis vector components can be extracted simultaneously and independently from the transmitted light by lock-in amplifiers with reference to the different demodulated frequencies. We find that the residual magnetic field is a significant factor that could affect triaxial coupling, and specially the influence of the z -axis remanence on xy -axis coupling is studied in detail. Under the optimal parameters, the three-axis sensitivities are 20 fT Hz − 1 / 2 in the x - and y - axis, and 230 fT Hz − 1 / 2 in the z -axis. Meanwhile, the three-axis bandwidths are 110 Hz, 138 Hz and 211 Hz in the x -, y - and z -axis, respectively. The proposed single-beam triaxial SERF atomic magnetometer could be used to construct a compact and low-cost atomic sensor that is particularly suitable for the vector measurement of the biomagnetic such as magnetoencephalography and magnetocardiography.
We report a single-beam triaxial atomic magnetometer based on cross bias magnetic field. Based on Bloch equation, the theory of single-beam scheme to achieve triaxial magnetic field detection is studied. To achieve triaxial magnetic field detection, the method of using cross bias magnetic field to rotate the atomic spin polarization direction is proposed and experimentally verified. By using only one single modulation magnetic field, it is possible to suppress low frequency noise and avoid the problem of magnetic field cross-talk. The experimental results show that the system response bandwidth to the magnetic field along X-axis is 90 Hz and the system sensitivity is 21 fT/(Hz1/2) under the zero-field condition. The system response bandwidth to the magnetic field along Y-axis is 130 Hz and the system sensitivity is 26 fT/(Hz1/2) when a bias magnetic field of 34 nT is applied in the Z-axis. The system response bandwidth to the magnetic field along Z-axis is 128 Hz and the system sensitivity is 29 fT/(Hz1/2) when a bias magnetic field of 38 nT is applied in the Y-axis. The proposed triaxial atomic magnetometer has the advantages of small size, simple structure and low fabrication cost, and is expected to be used in the biomedical and other fields.
High-sensitivity triaxial magnetic field measurements are crucial in various scientific and industrial applications, with spin-exchange relaxation-free (SERF) atomic magnetometers (AMs) standing out for their exceptional sensitivity. However, conventional methods for achieving triaxial measurements in SERF magnetometers typically involve multiple modulated magnetic fields, which introduce crosstalk challenges in array-based configurations. We propose a static bias magnetic field assisted optical modulation triaxial AM to address this limitation. In this configuration, the detuned circularly polarized light is utilized to achieve synchronous modulation of the fictitious magnetic field and pumping rate while incorporating a static bias magnetic field to generate a transverse projection component. We develop a comprehensive triaxial response model that fully considers the effects of the longitudinal spin polarization deflection. Building upon this model, we derive the relationship between the transverse spin component and the triaxial magnetic field and introduce parameter optimization methods to obtain optimal parameters, thus enabling triaxial measurements of 12 fT Hz −1/2 , 10 fT Hz −1/2 , and 15 fT Hz −1/2 along the x-, y -, and z -axes. Our approach offers significant advantages over existing methods, particularly in minimizing crosstalk and mitigating spin-exchange relaxation introduced by multiple modulated magnetic fields. Moreover, the effective detection of simulated magnetocardiography signals highlights the practical applicability and reliability of the proposed method in real-world scenarios.
The spin-exchange-relaxation-free (SERF) atomic magnetometer is an ultra-high sensitivity magnetometer, but it must be operated in a magnetic field with strength less than about 10 nT. Magnetic field compensation is an effective way to shield the magnetic field, and this paper demonstrates an in situ triaxial magnetic field compensation system for operating the SERF atomic magnetometer. The proposed hardware is based on optical pumping, which uses some part of the SERF atomic magnetometer itself, and the compensation method is implemented by analyzing the dynamics of the atomic spin. The experimental setup for this compensation system is described, and with this configuration, a residual magnetic field of strength less than 2 nT (±0.38 nT in the x axis, ±0.43 nT in the y axis, and ±1.62 nT in the z axis) has been achieved after compensation. The SERF atomic magnetometer was then used to verify that the residual triaxial magnetic fields were coincident with what were achieved by the compensation system.
We demonstrate a vector magnetometer based on parametric resonance, featuring a compact field configuration that requires only a linearly polarized optical beam and a radio-frequency (RF) field. The transverse components are measured simultaneously, followed by determination of the longitudinal component via a time-multiplexed application of a bias field, thereby achieving triaxial sensing. Validated experimentally and supported by theoretical modeling, the magnetometer operates at room temperature using spin-aligned metastable 4 He atoms, achieving kHz-scale bandwidth and directional sensitivities of 7 , 16 , and 24 f T / H z along the three orthogonal axes. Such a configuration circumvents the inherent sensitivity degradation and complexity typical of multi-beam or multi-RF-field schemes, offering a compact yet high-performance platform for vector magnetometry. Our work facilitates the miniaturization of vector magnetometers and supports advanced applications such as magnetic source localization and magnetic field imaging.
A single-beam atomic magnetometer being operated near zero-field and measuring three-axis fields simultaneously is demonstrated. We produce a rotating field on the x-0-y plane with the frequency of 90 Hz and a modulation field in the z axis at 130 Hz. The rotating field enables a nonzero z axis output when the transverse fields are zeroed using feedback systems. Based on the phase difference of π/2, x and y axes fields can be measured using one lock-in amplifier. Magnetic field sensitivities of 300 fT/Hz1∕2 in x and y axes and 3 pT/Hz1∕2 in the z axis are achieved.