Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Letters

Light-narrowed parametric resonance magnetometer with the fundamental sensitivity beyond the spin-exchange limit

Guiying Zhang, Hongjian Zeng, Ruihan Guo, Qing Zhang, Wenyue Yu, Qiang Lin

Published Aug 14, 2023• 7 citations
Publisher

Abstract

In the field of biomagnetic measurements, one of the most important recent challenges is to perform measurements in a magnetically unshielded environment. This first requires that atomic magnetometers can operate in a finite magnetic field, and have enough high sensitivity. To meet these requirements, we develop a light-narrowed parametric resonance (LPR) magnetometer. By adding a modulation magnetic field to the large longitudinal magnetic field, our LPR magnetometer can measure small transverse magnetic fields with an intrinsic sensitivity of 3.5 fT/Hz 1/2 in a longitudinal magnetic field of μ T range. Moreover, we have also demonstrated that in contrast to the previous light-narrowed scalar magnetometers, our LPR magnetometer has the potential to achieve higher sensitivity. Because in our case spin-exchange relaxation suppression by using light narrowing can lead to an improvement of fundamental sensitivity limit regardless of which quantum noise is dominant, and hence the fundamental sensitivity is no longer limited by spin-exchange, and approaches the fundamental limit set by the spin-exchange and spin-destruction cross sections.

DOI
10.1364/ol.496076

Related papers

Zero-field atomic magnetometer to extract longitudinal magnetic field

Shuying Wang, Jixi Lu, Kaixuan Zhang +3 more

Zero-field atomic ensembles enable the development of ultrahigh-sensitivity magnetometry. However, their intrinsic insensitivity to longitudinal magnetic fields along the pumping direction poses a fundamental limitation, restricting precise weak-field quantification and complex system decoupling. Herein, we propose a novel zero-field weak parametric modulation scheme capable of ultrahigh-sensitivity extraction of longitudinal magnetic fields. Transverse modulation is employed to manifest the electron spin polarization projection induced by the longitudinal fields. Based on the perturbation model established, first-order parametric resonance associated with the longitudinal magnetic field yields significant signal enhancement under low-frequency and weak modulation conditions, while simultaneously suppressing spin-exchange relaxation caused by magnetic field modulation. We experimentally achieved a longitudinal measurement sensitivity of 16 fT / Hz 1 / 2 , more than an order of magnitude improved over traditional schemes, with a bandwidth of 70 Hz. Benefiting from low spin relaxation, the noise floor of the transverse magnetic field measurement is preserved at 4 fT / Hz 1 / 2 . The proposed scheme pushes the boundaries of existing weak magnetic field measurement, providing critical capabilities for state-of-the-art precision experiments including new physical quantity detection.

Physical Review Research•Jul 18, 2025•5 citations

Radio-Frequency Magnetometry Based on Parametric Resonances

Wei Xiao, Xiyu Liu, Teng Wu +2 more

We propose and demonstrate a radio-frequency (rf) atomic magnetometer based on parametric resonances. Previously, most rf atomic magnetometers are based on magnetic resonances and their sensitivities are often limited by spin-exchange relaxation. Here, we introduce a novel scheme for an rf magnetometer where the rf magnetic field is measured by exciting the parametric resonances instead of magnetic resonances using parametric modulation fields. In this way, the spin-exchange relaxation is almost eliminated. Benefiting from the low spin relaxation rate, the parametric resonance scheme exhibits a narrower linewidth and stronger signal, which results in a higher sensitivity. With a 6×6×3 mm^{3} Rb atomic vapor cell, we developed an rf atomic magnetometer with a noise floor of 2 fT/Hz^{1/2}, which is about one order of magnitude higher than the sensitivity achieved in the magnetic-resonance-based scheme. The presented rf detection scheme holds promise in advancing rf atomic magnetometers and brings new insight into their various applications.

Physical Review Letters•Aug 27, 2024•24 citations

All-Optical Parametric-Resonance Magnetometer Based on 4He Atomic Alignment

Bowen Wang, Xiang Peng, Haidong Wang +2 more

Parametric-resonance magnetometer is a high-sensitivity quantum sensor characterized by applying the non-resonant radio-frequency (RF) fields to the atomic ensemble. The RF fields lead to crosstalk in the multi-sensor design, thus disturbing the magnetic-field measurement results. We propose an optically modulated alignment-based 4He parametric-resonance magnetometer. By using the fictitious field generated by the modulated light shift, parametric resonance is realized, and crosstalk caused by the magnetic RF field is prevented. The relative intensity noise of the lasers is suppressed to optimize the sensitivity of the magnetometer. Our magnetometer experimentally demonstrates a magnetic-field noise floor of 130 fT/Hz1/2 in both open- and closed-loop operations and has the potential to reach 70 fT/Hz1/2 when compared with the optimized magnetic RF scheme. It provides near-zero magnetic-field measurements with a 2 kHz bandwidth at room temperature, which is useful for high-bandwidth measurements in biomagnetic applications.

Sensors•May 31, 2022•4 citations

A High Sensitivity Closed-Loop Spin-Exchange Relaxation-Free Atomic Magnetometer With Broad Bandwidth

Qingqian Guo, Tao Hu, Chun-qiao Chen +6 more

Spin-exchange relaxation-free (SERF) atomic magnetometers are the promising non-cryogenic sensors to potentially replace the superconducting quantum interference device (SQUID) in the ultra-weak magnetic-field measurements. Although the SERF magnetometers have achieved a sensitivity of sub-femtotesla, the bandwidth is limited at a narrow range. In this work, we developed a closed-loop SERF magnetometer under proportional-integral (PI) control, the bandwidth could be adaptively tuned and extended above 1.2 kHz. A nearly 40-fold enhancement of the typical bandwidth was achieved in comparison with the open-loop system and the sensitivity was maintained at 15 fT/Hz1/2from 30 Hz to 750 Hz. Moreover, the magnetic field dynamic range could also be greatly improved. This proposed atomic magnetometer with higher bandwidth, sensitivity, and dynamic range has a good prospect in developing a compact, portable, and non-cryogenic magnetic field sensor and may find more applications in biomedical, nuclear magnetic resonance, and fundamental physics research.

IEEE Sensors Journal•Aug 3, 2021•36 citations

Compact, high-sensitivity atomic magnetometer utilizing the light-narrowing effect and in-phase excitation

Yuhao Guo, Shuangai Wan, Xiaoguang Sun +1 more

A high-sensitivity optically pumped atomic magnetometer working in the geomagnetic range utilizing the light-narrowing effect and in-phase excitation is described. The setup is based on a simple pump–probe arrangement built around a Cs vapor cell whose active volume is 64 mm3. The transverse oscillating field is applied parallel to the probe beam to drive Zeeman resonance, and the in-phase component of the resonance signal is measured to determine the field. The sensitivity of the magnetometer is improved by pumping most atoms into the stretched state. Consequently, spin-exchange relaxation is suppressed, and a sensitivity of 0.1 pT/Hz1/2 in the range of 10 μT is achieved. This magnetometer has the advantages of large dynamic range, high performance of low-frequency stabilization, high response speed, and compact size. It can be used for many cutting-edge applications such as detection of magnetic anomalies.

Applied Optics•Jan 17, 2019•29 citations

High-sensitivity closed-loop three-axis atomic magnetometer using two elliptically polarized laser beams

Yeguang Yan, Jixi Lu, Kun Wang +5 more

The high-sensitivity three-axis detection of magnetic fields is widely used in various applications.Our study demonstrates an atomic magnetometer detecting vector magnetic field, of which the core components are one glass cell and two elliptically polarized laser beams.The light-intensity noise is suppressed by differential detection technology, so a higher sensitivity is obtained compared with our previous work.The three-axis average sensitivities of the atomic magnetometer simultaneously reached 14 fT/Hz 1/2 along the x axis, 11 fT/Hz 1/2 along the y axis, and 25 fT/Hz 1/2 along the z axis.Furthermore, the atomic magnetometer's dynamic range was further improved to 150 nT, and its bandwidth was increased to over 200 Hz using a closed-loop control system.The proposed three-axis atomic magnetometer with a large dynamic range and a wide bandwidth holds great promise for biomagnetic measurement in a more challenging environment.

Chinese Optics Letters•Jan 1, 2024•1 citation
In the field of biomagnetic measurements, one of the most important recent challenges is to perform measurements in a magnetically unshielded environment. This first requires that atomic magnetometers can operate in a finite magnetic field, and have enough high sensitivity. To meet these requirements, we develop a light-narrowed parametric resonance (LPR) magnetometer. By adding a modulation magnetic field to the large longitudinal magnetic field, our LPR magnetometer can measure small transverse magnetic fields with an intrinsic sensitivity of 3.5 fT/Hz 1/2 in a longitudinal magnetic field of μ T range. Moreover, we have also demonstrated that in contrast to the previous light-narrowed scalar magnetometers, our LPR magnetometer has the potential to achieve higher sensitivity. Because in our case spin-exchange relaxation suppression by using light narrowing can lead to an improvement of fundamental sensitivity limit regardless of which quantum noise is dominant, and hence the fundamental sensitivity is no longer limited by spin-exchange, and approaches the fundamental limit set by the spin-exchange and spin-destruction cross sections.
Zero-field atomic ensembles enable the development of ultrahigh-sensitivity magnetometry. However, their intrinsic insensitivity to longitudinal magnetic fields along the pumping direction poses a fundamental limitation, restricting precise weak-field quantification and complex system decoupling. Herein, we propose a novel zero-field weak parametric modulation scheme capable of ultrahigh-sensitivity extraction of longitudinal magnetic fields. Transverse modulation is employed to manifest the electron spin polarization projection induced by the longitudinal fields. Based on the perturbation model established, first-order parametric resonance associated with the longitudinal magnetic field yields significant signal enhancement under low-frequency and weak modulation conditions, while simultaneously suppressing spin-exchange relaxation caused by magnetic field modulation. We experimentally achieved a longitudinal measurement sensitivity of 16 fT / Hz 1 / 2 , more than an order of magnitude improved over traditional schemes, with a bandwidth of 70 Hz. Benefiting from low spin relaxation, the noise floor of the transverse magnetic field measurement is preserved at 4 fT / Hz 1 / 2 . The proposed scheme pushes the boundaries of existing weak magnetic field measurement, providing critical capabilities for state-of-the-art precision experiments including new physical quantity detection.
We propose and demonstrate a radio-frequency (rf) atomic magnetometer based on parametric resonances. Previously, most rf atomic magnetometers are based on magnetic resonances and their sensitivities are often limited by spin-exchange relaxation. Here, we introduce a novel scheme for an rf magnetometer where the rf magnetic field is measured by exciting the parametric resonances instead of magnetic resonances using parametric modulation fields. In this way, the spin-exchange relaxation is almost eliminated. Benefiting from the low spin relaxation rate, the parametric resonance scheme exhibits a narrower linewidth and stronger signal, which results in a higher sensitivity. With a 6×6×3 mm^{3} Rb atomic vapor cell, we developed an rf atomic magnetometer with a noise floor of 2 fT/Hz^{1/2}, which is about one order of magnitude higher than the sensitivity achieved in the magnetic-resonance-based scheme. The presented rf detection scheme holds promise in advancing rf atomic magnetometers and brings new insight into their various applications.
Parametric-resonance magnetometer is a high-sensitivity quantum sensor characterized by applying the non-resonant radio-frequency (RF) fields to the atomic ensemble. The RF fields lead to crosstalk in the multi-sensor design, thus disturbing the magnetic-field measurement results. We propose an optically modulated alignment-based 4He parametric-resonance magnetometer. By using the fictitious field generated by the modulated light shift, parametric resonance is realized, and crosstalk caused by the magnetic RF field is prevented. The relative intensity noise of the lasers is suppressed to optimize the sensitivity of the magnetometer. Our magnetometer experimentally demonstrates a magnetic-field noise floor of 130 fT/Hz1/2 in both open- and closed-loop operations and has the potential to reach 70 fT/Hz1/2 when compared with the optimized magnetic RF scheme. It provides near-zero magnetic-field measurements with a 2 kHz bandwidth at room temperature, which is useful for high-bandwidth measurements in biomagnetic applications.
Spin-exchange relaxation-free (SERF) atomic magnetometers are the promising non-cryogenic sensors to potentially replace the superconducting quantum interference device (SQUID) in the ultra-weak magnetic-field measurements. Although the SERF magnetometers have achieved a sensitivity of sub-femtotesla, the bandwidth is limited at a narrow range. In this work, we developed a closed-loop SERF magnetometer under proportional-integral (PI) control, the bandwidth could be adaptively tuned and extended above 1.2 kHz. A nearly 40-fold enhancement of the typical bandwidth was achieved in comparison with the open-loop system and the sensitivity was maintained at 15 fT/Hz1/2from 30 Hz to 750 Hz. Moreover, the magnetic field dynamic range could also be greatly improved. This proposed atomic magnetometer with higher bandwidth, sensitivity, and dynamic range has a good prospect in developing a compact, portable, and non-cryogenic magnetic field sensor and may find more applications in biomedical, nuclear magnetic resonance, and fundamental physics research.
A high-sensitivity optically pumped atomic magnetometer working in the geomagnetic range utilizing the light-narrowing effect and in-phase excitation is described. The setup is based on a simple pump–probe arrangement built around a Cs vapor cell whose active volume is 64 mm3. The transverse oscillating field is applied parallel to the probe beam to drive Zeeman resonance, and the in-phase component of the resonance signal is measured to determine the field. The sensitivity of the magnetometer is improved by pumping most atoms into the stretched state. Consequently, spin-exchange relaxation is suppressed, and a sensitivity of 0.1 pT/Hz1/2 in the range of 10 μT is achieved. This magnetometer has the advantages of large dynamic range, high performance of low-frequency stabilization, high response speed, and compact size. It can be used for many cutting-edge applications such as detection of magnetic anomalies.
The high-sensitivity three-axis detection of magnetic fields is widely used in various applications.Our study demonstrates an atomic magnetometer detecting vector magnetic field, of which the core components are one glass cell and two elliptically polarized laser beams.The light-intensity noise is suppressed by differential detection technology, so a higher sensitivity is obtained compared with our previous work.The three-axis average sensitivities of the atomic magnetometer simultaneously reached 14 fT/Hz 1/2 along the x axis, 11 fT/Hz 1/2 along the y axis, and 25 fT/Hz 1/2 along the z axis.Furthermore, the atomic magnetometer's dynamic range was further improved to 150 nT, and its bandwidth was increased to over 200 Hz using a closed-loop control system.The proposed three-axis atomic magnetometer with a large dynamic range and a wide bandwidth holds great promise for biomagnetic measurement in a more challenging environment.