Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review A

Light-induced line narrowing of the magnetic resonance in a parametric resonance optically pumped rubidium magnetometer

Yongbiao Yang, Yang Li, Zhengyu Su, Jun He, Xiaojun Jia, Yanhua Wang, Junmin Wang

Published Oct 14, 2026• 0 citations
Publisher
DOI
10.1103/sbb6-t133

Related papers

Improving the sensitivity of an optically pumped rubidium atomic magnetometer by using of a repumping laser beam

Lulu Zhang, Le-Le Bai, Yu-Lin Yang +5 more

For the experimental implementation of an optically pumped atomic magnetometer, the magnetic resonance signal with a narrow linewidth and a high signal-to-noise ratio (SNR) is required for achieving a high sensitivity. Using 795-nm laser as both the pumping and the probe laser, we compare the magnetic resonance signals from different rubidium atomic vapor cells and investigate the variations of magnetic resonance signals with temperature. Optimized magnetic resonance signal is achieved with a paraffin-coated rubidium atomic vapor cell. Then the 780-nm laser at rubidium D2 line is introduced as a repumping laser, and we explore the changes of linewidth and SNR of the magnetic resonance signal under different power of the pumping laser and the repumping laser. Owing to the 780-nm repumping laser beam, the signal amplitude of rubidium-85 magnetic resonance signal is improved remarkably because more rubidium-85 atoms are spin- polarized by the 795-nm pumping laser beam. At the same time, the linewidth of rubidium-85 magnetic resonance signal is roughly not broadened anymore. We realize a closed-loop optically pumped rubidium-85 atomic magnetometer with a bandwidth of ~1.2 kHz, and the sensitivity is calibrated to be ~245.5 pT/Hz1/2 only with the 795-nm pumping laser beam. Owing to the employment of the 780-nm repumping laser beam, the sensitivity is improved to be ~26.4 pT/Hz1/2 which is improved roughly by one order of magnitude. We also calibrate the measurement accuracy and deviation of a commercial fluxgate magnetometer by using the enhanced rubidium magnetic resonance signal.

Acta Physica Sinica•Jan 1, 2021•5 citations

Optically pumped rubidium atomic magnetometer with elliptically polarized light

Zhichao Ding, Jie Yuan, Zhiguo Wang +2 more

Optik•Mar 11, 2016•21 citations

Research of optimal pump light intensity in rubidium atomic magnetometers

Jiajia Li, Ding Zhichao, Zhiguo Wang +2 more

Laser Technology•Jan 1, 2016•0 citations

Anomalous narrowing of magnetic-resonance linewidths in optically pumped alkali-metal vapors

T. McClelland, L. K. Lam, T. M. Kwon

Narrowing of magnetic-resonance lines in a dense optically pumped alkali-metal vapor ${(}^{87}$Rb) has been observed. This observation is shown to be a result of optical pumping with a monochromatic light source tuned such that the real part of the vapor polarizability, which is responsible for light shifts, is essentially zero. A model based on the Bloch equations is used to describe the observed narrowing effect, and results of numerical calculations based on this model are presented. The results agree qualitatively with observations, and show correctly the disappearance of the effect at low light levels. This narrowing effect is of importance to the development of precision frequency standards and magnetometers utilizing monochromatic light sources (such as semiconductor lasers).

Physical Review A•Mar 1, 1986•6 citations

Light modulation by a magnetic resonance in a paramagnet

Andrei V. Butashin, S. O. Demokritov, Natalia M. Kreines +1 more

ZhETF Pisma Redaktsiiu•Nov 1, 1983•0 citations

In Situ Calibration of Magnetic Field Coils Using Parametric Resonance in Optically-pumped Magnetometers

Wei Xiao, He Wang, Xiangzhi Zhang +5 more

In this article, we propose an in situ method to calibrate the magnetic-field coil systems in optically-pumped magnetometers. The method is based on parametric resonance induced by nonresonant radio-frequency (RF) fields, and is especially suitable for microfabricated single-beam zero-field atomic magnetometers. We have experimentally and theoretically demonstrated this method with a single-beam spin-exchange-relaxation-free (SERF) magnetometer, and the experiment results are in line with theoretical expectations.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 7, 2021•4 citations
For the experimental implementation of an optically pumped atomic magnetometer, the magnetic resonance signal with a narrow linewidth and a high signal-to-noise ratio (SNR) is required for achieving a high sensitivity. Using 795-nm laser as both the pumping and the probe laser, we compare the magnetic resonance signals from different rubidium atomic vapor cells and investigate the variations of magnetic resonance signals with temperature. Optimized magnetic resonance signal is achieved with a paraffin-coated rubidium atomic vapor cell. Then the 780-nm laser at rubidium D2 line is introduced as a repumping laser, and we explore the changes of linewidth and SNR of the magnetic resonance signal under different power of the pumping laser and the repumping laser. Owing to the 780-nm repumping laser beam, the signal amplitude of rubidium-85 magnetic resonance signal is improved remarkably because more rubidium-85 atoms are spin- polarized by the 795-nm pumping laser beam. At the same time, the linewidth of rubidium-85 magnetic resonance signal is roughly not broadened anymore. We realize a closed-loop optically pumped rubidium-85 atomic magnetometer with a bandwidth of ~1.2 kHz, and the sensitivity is calibrated to be ~245.5 pT/Hz1/2 only with the 795-nm pumping laser beam. Owing to the employment of the 780-nm repumping laser beam, the sensitivity is improved to be ~26.4 pT/Hz1/2 which is improved roughly by one order of magnitude. We also calibrate the measurement accuracy and deviation of a commercial fluxgate magnetometer by using the enhanced rubidium magnetic resonance signal.
Narrowing of magnetic-resonance lines in a dense optically pumped alkali-metal vapor (87{(}^{87}(87Rb) has been observed. This observation is shown to be a result of optical pumping with a monochromatic light source tuned such that the real part of the vapor polarizability, which is responsible for light shifts, is essentially zero. A model based on the Bloch equations is used to describe the observed narrowing effect, and results of numerical calculations based on this model are presented. The results agree qualitatively with observations, and show correctly the disappearance of the effect at low light levels. This narrowing effect is of importance to the development of precision frequency standards and magnetometers utilizing monochromatic light sources (such as semiconductor lasers).
In this article, we propose an in situ method to calibrate the magnetic-field coil systems in optically-pumped magnetometers. The method is based on parametric resonance induced by nonresonant radio-frequency (RF) fields, and is especially suitable for microfabricated single-beam zero-field atomic magnetometers. We have experimentally and theoretically demonstrated this method with a single-beam spin-exchange-relaxation-free (SERF) magnetometer, and the experiment results are in line with theoretical expectations.