Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Acta Physica Sinica

Improving the sensitivity of an optically pumped rubidium atomic magnetometer by using of a repumping laser beam

Lulu Zhang, Le-Le Bai, Yu-Lin Yang, Yongbiao Yang, Yanhua Wang, Xin Wen, Jun He, Junmin Wang

Published Jan 1, 2021• 5 citations
Publisher

Abstract

For the experimental implementation of an optically pumped atomic magnetometer, the magnetic resonance signal with a narrow linewidth and a high signal-to-noise ratio (SNR) is required for achieving a high sensitivity. Using 795-nm laser as both the pumping and the probe laser, we compare the magnetic resonance signals from different rubidium atomic vapor cells and investigate the variations of magnetic resonance signals with temperature. Optimized magnetic resonance signal is achieved with a paraffin-coated rubidium atomic vapor cell. Then the 780-nm laser at rubidium D2 line is introduced as a repumping laser, and we explore the changes of linewidth and SNR of the magnetic resonance signal under different power of the pumping laser and the repumping laser. Owing to the 780-nm repumping laser beam, the signal amplitude of rubidium-85 magnetic resonance signal is improved remarkably because more rubidium-85 atoms are spin- polarized by the 795-nm pumping laser beam. At the same time, the linewidth of rubidium-85 magnetic resonance signal is roughly not broadened anymore. We realize a closed-loop optically pumped rubidium-85 atomic magnetometer with a bandwidth of ~1.2 kHz, and the sensitivity is calibrated to be ~245.5 pT/Hz1/2 only with the 795-nm pumping laser beam. Owing to the employment of the 780-nm repumping laser beam, the sensitivity is improved to be ~26.4 pT/Hz1/2 which is improved roughly by one order of magnitude. We also calibrate the measurement accuracy and deviation of a commercial fluxgate magnetometer by using the enhanced rubidium magnetic resonance signal.

DOI
10.7498/aps.70.20210920

Related papers

Multi-Parameter Optimization of Rubidium Laser Optically Pumped Magnetometers with Geomagnetic Field Intensity

Kun Xu, Xiuyan Ren, Yujie Xiang +7 more

Rubidium laser optically pumped magnetometers (OPMs) are widely used magnetic sensors based on the Zeeman effect, laser pumping, and magnetic resonance principles. They measure the magnetic field by measuring the magnetic resonance signal passing through a rubidium atomic gas cell. The quality of the magnetic resonance signal is a necessary condition for a magnetometer to achieve high sensitivity. In this research, to obtain the best magnetic resonance signal of rubidium laser OPMs in the Earth’s magnetic field intensity, the experiment system of rubidium laser OPMs is built with a rubidium atomic gas cell as the core component. The linewidth and amplitude ratio (LAR) of magnetic resonance signals is utilized as the optimization objective function. The magnetic resonance signals of the magnetometer experiment system are experimentally measured for different laser frequencies, radio frequency (RF) intensities, laser powers, and atomic gas cell temperatures in a background magnetic field of 50,765 nT. The experimental results indicate that optimizing these parameters can reduce the LAR by one order of magnitude. This shows that the optimal parameter combination can effectively improve the sensitivity of the magnetometer. The sensitivity defined using the noise spectral density measured under optimal experimental parameters is 1.5 pT/Hz1/2@1 Hz. This work will provide key technical support for rubidium laser OPMs’ product development.

Sensors•Nov 2, 2023•6 citations

Sensitivity Improvement of Spin-Exchange Relaxation Free Atomic Magnetometers by Hybrid Optical Pumping of Potassium and Rubidium

Yosuke Ito, Hiroyuki Ohnishi, Keigo Kamada +1 more

An optically pumped atomic magnetometer using a hybrid cell of potassium and rubidium atoms was demonstrated to yield high sensitivity to magnetic fields. We operated the magnetometer with the four possible combinations of optically pumped and optically probed atoms and found that the combination of optically pumped potassium and optically probed rubidium showed the highest sensitivity among the four combinations because the rubidium atoms were denser than those of potassium. Furthermore, we investigated the dependence of the sensitivity on the power densities of the pump and probe beams and the wavelength of the probe beam. The magnetometer using the hybrid cell required higher pump-beam power and had narrower magnetic linewidth than those of the single alkali-metal cell. However, the magnetic linewidth was larger than the theoretical value, ignoring the spin relaxation caused by the spin-exchange collisions. By adjusting the laser conditions, the highest sensitivity approached 30 fTrms/Hz1/2.

IEEE Transactions on Magnetics•Oct 1, 2011•53 citations

A Multi-Pass Optically Pumped Rubidium Atomic Magnetometer with Free Induction Decay

Lulu Zhang, Yongbiao Yang, Ni Zhao +2 more

A free-induction-decay (FID) type optically-pumped rubidium atomic magnetometer driven by a radio-frequency (RF) magnetic field is presented in this paper. Influences of parameters, such as the temperature of rubidium vapor cell, the power of pump beam, and the strength of RF magnetic field and static magnetic field on the amplitude and the full width at half maximum (FWHM) of the FID signal, have been investigated in the time domain and frequency domain. At the same time, the sensitivities of the magnetometer for the single-pass and the triple-pass probe beam cases have been compared by changing the optical path of the interaction between probe beam and atomic ensemble. Compared with the sensitivity of ∼21.2 pT/Hz1/2 in the case of the single-pass probe beam, the amplitude of FID signal in the case of the triple-pass probe beam has been significantly enhanced, and the sensitivity has been improved to ∼13.4 pT/Hz1/2. The research in this paper provids a reference for the subsequent study of influence of different buffer gas pressure on the FWHM and also a foundation for further improving the sensitivity of FID rubidium atomic magnetometer by employing a polarization-squeezed light as probe beam, to achieve a sensitivity beyond the photo-shot-noise level.

arXiv:2301.08437•Sensors•Oct 7, 2022•18 citations

Research on an pump-probe rubidium magnetometer

Zhiguo Wang, Luo Hui, Fan Zhenfang +1 more

In order to measure a weak alternating magnetic field, an optically-pumped Rb magnetometer based on pump-probe structure is investigated and demonstrated. The pumping light and probing light propagate along the z axis and x axis, respectively. A constant polarization magnetic field along the pumping light is applied, which not only stabilizes the polarization of Rb atoms but also tunes resonance frequency of Rb atoms. When a weak alternating magnetic field is applied perpendicularly to the constant magnetic field, the magnetic moment will tip off the z axis and rotate around the z axis. And then the polarization plane of probing light is modulated correspondingly. The x component of the magnetic moment can be obtained with a balanced detector. As a result, a signal proportional to weak alternating magnetic field can be obtained.In order to obtain the magnetic response of the magnetometer, we analyze the signal amplitude as a function of polarization magnetic field strength B0 and transverse relaxation time 2 with numerical simulation. The amplitude-frequency response of the magnetometer is determined mainly by two parameters, namely cutoff frequency c=1/2 and resonance frequency 0= B0, where is the gyromagnetic ratio of Rb atom. At low frequency, that is a0 and a 0c2, the magnetometer has a flat response, here a is the frequency of the weak alternating magnetic field. If 0c, the signal amplitude will be large for large 0 or small c. For a given c, the peak response appears at 0=c. In the vicinity of resonance frequency, if c0, a peak will appear and if c 0, no peak occurs. At high frequency, the amplitude will decrease with the increase of a.We verify the above analyses in experiment. A vapor cell with a short transverse relaxation time is used to obtain large frequency response bandwidth. Through optimizing the powers and frequencies of pumping laser and probing laser, high polarization and detection sensitivity of atomic spin can be obtained. Moreover, through choosing an appropriate polarization magnetic field, the magnetometer can be maximally sensitive to the magnetic field to be measured. The experimental results show that the magnetometer has a sensitivity of about m 0.2; pT/HzHz and bandwidth of about 3.5 kHz. It can be used to detect low field magnetic resonance and high frequency abnormal physical phenomena.

Acta Physica Sinica•Jan 1, 2016•4 citations

Improving the sensitivity of optically pumped magnetometers by hyperfine repumping

V. Schultze, Theo Scholtes, R.P.J. IJsselsteijn +1 more

Most optically pumped magnetometers based on alkali atom vapor cells and pumped by a single narrow-band laser suffer from a loss of signal since atoms become trapped in the ground hyperfine states that are not coupled to the laser beam. This can be counteracted by additional optical repumping of these ground-state levels. We study hyperfine repumping using cesium vapor cells with partly overlapped ground-state splitting due to their nitrogen buffer-gas filling. We implement two methods of repumping and compare them to the conventional case of F=4 pumping: F=3 repumping with an additional repumper laser and combined pumping/repumping in the light-narrowing mode, where a single high-power laser is tuned near the F=3 transitions. All these modes are investigated for two different methods of spin-phase synchronization: the Mx and intensity modulation methods. For both methods, any kind of repumping results in a clear improvement of the magnetometer sensitivity compared to no repumping, but in the Mx mode it is more pronounced (about 50 versus 200 fT/√Hz for a 50 mm3 Cs vapor cell). The mechanisms responsible for the distinct results in the different working modes are discussed.

Journal of the Optical Society of America B•Apr 2, 2015•20 citations

Quantum-enhanced rubidium atomic magnetometer based on Faraday rotation via 795 nm stokes operator squeezed light

Lele Bai, Xin Wen, Yu-Lin Yang +4 more

Abstract With the help of Stokes operator Ŝ 2 squeezed state (also called polarization squeezed state (PSS)) of 795 nm light, rubidium-87 ( 87 Rb) atomic magnetometer based on Faraday rotation (FR) has been implemented and characterized. The PSS of Stokes operator Ŝ 2 of 795 nm light has been prepared by means of coherently combining the polarization coherent state (PCS) of a linearly p-polarized bright 795 nm light beam and a linearly s-polarized squeezed vacuum state (SVS) generated by a 397.5 nm ultraviolet laser pumped sub-threshold optical parametric oscillator (OPO) with a PPKTP bulk crystal inside the OPO cavity. PSS with a squeezing level of −3.7 ± 0.3 dB has been achieved around the analysis frequency of 10 kHz. At different transitions of D 1 line, various frequency detuning, and reasonable atomic vapor cell’s temperature, FR has been measured and compared. To decrease absorption (scattering) losses and the back-action from atomic spin noise to the probe beam’s polarization noise for maintaining the quantum properties of PSS of Stokes operator Ŝ 2 of 795 nm light, we had to run our magnetometer with 87 Rb vapor cell’s temperature below 60 °C, at which the PSS was almost destroyed. The sensitivities of magnetic field measurement were characterized via measuring signal-to-noise ratio of the alternating current calibrated magnetic field signal with a balanced polarimeter. Under the conditions of the atomic number density of ∼5.8 × 10 10 cm −3 ( T ∼ 40 °C) and the probe beam with a detuning of ∼−400 MHz relative to the 5S 1/2 ( F g = 2) − 5P 1/2 ( F e = 1) transition of 87 Rb D 1 line, a typical sensitivity of ∼19.5 pT (Hz 1/2 ) −1 has been achieved employing PSS of Stokes operator Ŝ 2 as the probe, compared with a sensitivity of ∼28.3pT (Hz 1/2 ) −1 using PCS as the probe. We preliminarily demonstrated that the quantum-enhanced sensitivity in a Faraday-rotation-based 87 Rb atomic magnetometer with the help of PSS of 795 nm light.

arXiv:2112.00186•Journal of Optics•Aug 1, 2021•28 citations
For the experimental implementation of an optically pumped atomic magnetometer, the magnetic resonance signal with a narrow linewidth and a high signal-to-noise ratio (SNR) is required for achieving a high sensitivity. Using 795-nm laser as both the pumping and the probe laser, we compare the magnetic resonance signals from different rubidium atomic vapor cells and investigate the variations of magnetic resonance signals with temperature. Optimized magnetic resonance signal is achieved with a paraffin-coated rubidium atomic vapor cell. Then the 780-nm laser at rubidium D2 line is introduced as a repumping laser, and we explore the changes of linewidth and SNR of the magnetic resonance signal under different power of the pumping laser and the repumping laser. Owing to the 780-nm repumping laser beam, the signal amplitude of rubidium-85 magnetic resonance signal is improved remarkably because more rubidium-85 atoms are spin- polarized by the 795-nm pumping laser beam. At the same time, the linewidth of rubidium-85 magnetic resonance signal is roughly not broadened anymore. We realize a closed-loop optically pumped rubidium-85 atomic magnetometer with a bandwidth of ~1.2 kHz, and the sensitivity is calibrated to be ~245.5 pT/Hz1/2 only with the 795-nm pumping laser beam. Owing to the employment of the 780-nm repumping laser beam, the sensitivity is improved to be ~26.4 pT/Hz1/2 which is improved roughly by one order of magnitude. We also calibrate the measurement accuracy and deviation of a commercial fluxgate magnetometer by using the enhanced rubidium magnetic resonance signal.
Rubidium laser optically pumped magnetometers (OPMs) are widely used magnetic sensors based on the Zeeman effect, laser pumping, and magnetic resonance principles. They measure the magnetic field by measuring the magnetic resonance signal passing through a rubidium atomic gas cell. The quality of the magnetic resonance signal is a necessary condition for a magnetometer to achieve high sensitivity. In this research, to obtain the best magnetic resonance signal of rubidium laser OPMs in the Earth’s magnetic field intensity, the experiment system of rubidium laser OPMs is built with a rubidium atomic gas cell as the core component. The linewidth and amplitude ratio (LAR) of magnetic resonance signals is utilized as the optimization objective function. The magnetic resonance signals of the magnetometer experiment system are experimentally measured for different laser frequencies, radio frequency (RF) intensities, laser powers, and atomic gas cell temperatures in a background magnetic field of 50,765 nT. The experimental results indicate that optimizing these parameters can reduce the LAR by one order of magnitude. This shows that the optimal parameter combination can effectively improve the sensitivity of the magnetometer. The sensitivity defined using the noise spectral density measured under optimal experimental parameters is 1.5 pT/Hz1/2@1 Hz. This work will provide key technical support for rubidium laser OPMs’ product development.
An optically pumped atomic magnetometer using a hybrid cell of potassium and rubidium atoms was demonstrated to yield high sensitivity to magnetic fields. We operated the magnetometer with the four possible combinations of optically pumped and optically probed atoms and found that the combination of optically pumped potassium and optically probed rubidium showed the highest sensitivity among the four combinations because the rubidium atoms were denser than those of potassium. Furthermore, we investigated the dependence of the sensitivity on the power densities of the pump and probe beams and the wavelength of the probe beam. The magnetometer using the hybrid cell required higher pump-beam power and had narrower magnetic linewidth than those of the single alkali-metal cell. However, the magnetic linewidth was larger than the theoretical value, ignoring the spin relaxation caused by the spin-exchange collisions. By adjusting the laser conditions, the highest sensitivity approached 30 fTrms/Hz1/2.
A free-induction-decay (FID) type optically-pumped rubidium atomic magnetometer driven by a radio-frequency (RF) magnetic field is presented in this paper. Influences of parameters, such as the temperature of rubidium vapor cell, the power of pump beam, and the strength of RF magnetic field and static magnetic field on the amplitude and the full width at half maximum (FWHM) of the FID signal, have been investigated in the time domain and frequency domain. At the same time, the sensitivities of the magnetometer for the single-pass and the triple-pass probe beam cases have been compared by changing the optical path of the interaction between probe beam and atomic ensemble. Compared with the sensitivity of ∼21.2 pT/Hz1/2 in the case of the single-pass probe beam, the amplitude of FID signal in the case of the triple-pass probe beam has been significantly enhanced, and the sensitivity has been improved to ∼13.4 pT/Hz1/2. The research in this paper provids a reference for the subsequent study of influence of different buffer gas pressure on the FWHM and also a foundation for further improving the sensitivity of FID rubidium atomic magnetometer by employing a polarization-squeezed light as probe beam, to achieve a sensitivity beyond the photo-shot-noise level.
In order to measure a weak alternating magnetic field, an optically-pumped Rb magnetometer based on pump-probe structure is investigated and demonstrated. The pumping light and probing light propagate along the z axis and x axis, respectively. A constant polarization magnetic field along the pumping light is applied, which not only stabilizes the polarization of Rb atoms but also tunes resonance frequency of Rb atoms. When a weak alternating magnetic field is applied perpendicularly to the constant magnetic field, the magnetic moment will tip off the z axis and rotate around the z axis. And then the polarization plane of probing light is modulated correspondingly. The x component of the magnetic moment can be obtained with a balanced detector. As a result, a signal proportional to weak alternating magnetic field can be obtained.In order to obtain the magnetic response of the magnetometer, we analyze the signal amplitude as a function of polarization magnetic field strength B0 and transverse relaxation time 2 with numerical simulation. The amplitude-frequency response of the magnetometer is determined mainly by two parameters, namely cutoff frequency c=1/2 and resonance frequency 0= B0, where is the gyromagnetic ratio of Rb atom. At low frequency, that is a0 and a 0c2, the magnetometer has a flat response, here a is the frequency of the weak alternating magnetic field. If 0c, the signal amplitude will be large for large 0 or small c. For a given c, the peak response appears at 0=c. In the vicinity of resonance frequency, if c0, a peak will appear and if c 0, no peak occurs. At high frequency, the amplitude will decrease with the increase of a.We verify the above analyses in experiment. A vapor cell with a short transverse relaxation time is used to obtain large frequency response bandwidth. Through optimizing the powers and frequencies of pumping laser and probing laser, high polarization and detection sensitivity of atomic spin can be obtained. Moreover, through choosing an appropriate polarization magnetic field, the magnetometer can be maximally sensitive to the magnetic field to be measured. The experimental results show that the magnetometer has a sensitivity of about m 0.2; pT/HzHz and bandwidth of about 3.5 kHz. It can be used to detect low field magnetic resonance and high frequency abnormal physical phenomena.
Most optically pumped magnetometers based on alkali atom vapor cells and pumped by a single narrow-band laser suffer from a loss of signal since atoms become trapped in the ground hyperfine states that are not coupled to the laser beam. This can be counteracted by additional optical repumping of these ground-state levels. We study hyperfine repumping using cesium vapor cells with partly overlapped ground-state splitting due to their nitrogen buffer-gas filling. We implement two methods of repumping and compare them to the conventional case of F=4 pumping: F=3 repumping with an additional repumper laser and combined pumping/repumping in the light-narrowing mode, where a single high-power laser is tuned near the F=3 transitions. All these modes are investigated for two different methods of spin-phase synchronization: the Mx and intensity modulation methods. For both methods, any kind of repumping results in a clear improvement of the magnetometer sensitivity compared to no repumping, but in the Mx mode it is more pronounced (about 50 versus 200 fT/√Hz for a 50 mm3 Cs vapor cell). The mechanisms responsible for the distinct results in the different working modes are discussed.
Abstract With the help of Stokes operator Ŝ 2 squeezed state (also called polarization squeezed state (PSS)) of 795 nm light, rubidium-87 ( 87 Rb) atomic magnetometer based on Faraday rotation (FR) has been implemented and characterized. The PSS of Stokes operator Ŝ 2 of 795 nm light has been prepared by means of coherently combining the polarization coherent state (PCS) of a linearly p-polarized bright 795 nm light beam and a linearly s-polarized squeezed vacuum state (SVS) generated by a 397.5 nm ultraviolet laser pumped sub-threshold optical parametric oscillator (OPO) with a PPKTP bulk crystal inside the OPO cavity. PSS with a squeezing level of −3.7 ± 0.3 dB has been achieved around the analysis frequency of 10 kHz. At different transitions of D 1 line, various frequency detuning, and reasonable atomic vapor cell’s temperature, FR has been measured and compared. To decrease absorption (scattering) losses and the back-action from atomic spin noise to the probe beam’s polarization noise for maintaining the quantum properties of PSS of Stokes operator Ŝ 2 of 795 nm light, we had to run our magnetometer with 87 Rb vapor cell’s temperature below 60 °C, at which the PSS was almost destroyed. The sensitivities of magnetic field measurement were characterized via measuring signal-to-noise ratio of the alternating current calibrated magnetic field signal with a balanced polarimeter. Under the conditions of the atomic number density of ∼5.8 × 10 10 cm −3 ( T ∼ 40 °C) and the probe beam with a detuning of ∼−400 MHz relative to the 5S 1/2 ( F g = 2) − 5P 1/2 ( F e = 1) transition of 87 Rb D 1 line, a typical sensitivity of ∼19.5 pT (Hz 1/2 ) −1 has been achieved employing PSS of Stokes operator Ŝ 2 as the probe, compared with a sensitivity of ∼28.3pT (Hz 1/2 ) −1 using PCS as the probe. We preliminarily demonstrated that the quantum-enhanced sensitivity in a Faraday-rotation-based 87 Rb atomic magnetometer with the help of PSS of 795 nm light.