Abstract With the help of Stokes operator Ŝ 2 squeezed state (also called polarization squeezed state (PSS)) of 795 nm light, rubidium-87 ( 87 Rb) atomic magnetometer based on Faraday rotation (FR) has been implemented and characterized. The PSS of Stokes operator Ŝ 2 of 795 nm light has been prepared by means of coherently combining the polarization coherent state (PCS) of a linearly p-polarized bright 795 nm light beam and a linearly s-polarized squeezed vacuum state (SVS) generated by a 397.5 nm ultraviolet laser pumped sub-threshold optical parametric oscillator (OPO) with a PPKTP bulk crystal inside the OPO cavity. PSS with a squeezing level of −3.7 ± 0.3 dB has been achieved around the analysis frequency of 10 kHz. At different transitions of D 1 line, various frequency detuning, and reasonable atomic vapor cell’s temperature, FR has been measured and compared. To decrease absorption (scattering) losses and the back-action from atomic spin noise to the probe beam’s polarization noise for maintaining the quantum properties of PSS of Stokes operator Ŝ 2 of 795 nm light, we had to run our magnetometer with 87 Rb vapor cell’s temperature below 60 °C, at which the PSS was almost destroyed. The sensitivities of magnetic field measurement were characterized via measuring signal-to-noise ratio of the alternating current calibrated magnetic field signal with a balanced polarimeter. Under the conditions of the atomic number density of ∼5.8 × 10 10 cm −3 ( T ∼ 40 °C) and the probe beam with a detuning of ∼−400 MHz relative to the 5S 1/2 ( F g = 2) − 5P 1/2 ( F e = 1) transition of 87 Rb D 1 line, a typical sensitivity of ∼19.5 pT (Hz 1/2 ) −1 has been achieved employing PSS of Stokes operator Ŝ 2 as the probe, compared with a sensitivity of ∼28.3pT (Hz 1/2 ) −1 using PCS as the probe. We preliminarily demonstrated that the quantum-enhanced sensitivity in a Faraday-rotation-based 87 Rb atomic magnetometer with the help of PSS of 795 nm light.
Abstract With the help of Stokes operator Ŝ 2 squeezed state (also called polarization squeezed state (PSS)) of 795 nm light, rubidium-87 ( 87 Rb) atomic magnetometer based on Faraday rotation (FR) has been implemented and characterized. The PSS of Stokes operator Ŝ 2 of 795 nm light has been prepared by means of coherently combining the polarization coherent state (PCS) of a linearly p-polarized bright 795 nm light beam and a linearly s-polarized squeezed vacuum state (SVS) generated by a 397.5 nm ultraviolet laser pumped sub-threshold optical parametric oscillator (OPO) with a PPKTP bulk crystal inside the OPO cavity. PSS with a squeezing level of −3.7 ± 0.3 dB has been achieved around the analysis frequency of 10 kHz. At different transitions of D 1 line, various frequency detuning, and reasonable atomic vapor cell’s temperature, FR has been measured and compared. To decrease absorption (scattering) losses and the back-action from atomic spin noise to the probe beam’s polarization noise for maintaining the quantum properties of PSS of Stokes operator Ŝ 2 of 795 nm light, we had to run our magnetometer with 87 Rb vapor cell’s temperature below 60 °C, at which the PSS was almost destroyed. The sensitivities of magnetic field measurement were characterized via measuring signal-to-noise ratio of the alternating current calibrated magnetic field signal with a balanced polarimeter. Under the conditions of the atomic number density of ∼5.8 × 10 10 cm −3 ( T ∼ 40 °C) and the probe beam with a detuning of ∼−400 MHz relative to the 5S 1/2 ( F g = 2) − 5P 1/2 ( F e = 1) transition of 87 Rb D 1 line, a typical sensitivity of ∼19.5 pT (Hz 1/2 ) −1 has been achieved employing PSS of Stokes operator Ŝ 2 as the probe, compared with a sensitivity of ∼28.3pT (Hz 1/2 ) −1 using PCS as the probe. We preliminarily demonstrated that the quantum-enhanced sensitivity in a Faraday-rotation-based 87 Rb atomic magnetometer with the help of PSS of 795 nm light.
We measured the spin noise spectroscopy (SNS) of rubidium atomic ensemble with two different kinds of atomic vapor cells (filled with buffer gas or coated with paraffin film on the inner wall) and demonstrated the enhancement of the signal-to-noise ratio (SNR) by using polarization squeezed state (PSS) of 795-nm light field with Stokes operator S Λ 2 squeezed. The PSS is prepared by locking the relative phase between the squeezed vacuum state of light obtained with a sub-threshold optical parametric oscillator and the orthogonally polarized local oscillator beam by means of the quantum noise lock. Under the same conditions, the PSS can be employed not only to improve the SNR, but also to keep the full width at half maximum (FWHM) of SNS, compared with the case of using the polarization coherent state (PCS), enhancement of SNR is positively correlated with the squeezing level of the PSS. With increasing probe laser power and atomic number density, the SNR and FWHM of SNS will increase correspondingly. With the help of the PSS of the Stokes operator S Λ 2 , quantum improvements of both the SNR and FWHM of SNS signal has been demonstrated by controlling optical power of polarization squeezed light beam or atomic number density in our experiments.
We report on an optical magnetometer enhanced by vacuum-squeezed light, employing an Mx magnetometer based on 87Rb vapor in a micrometer-scale cell (~100 μm). Using the well-established polarization self-rotation effect in a room-temperature 87Rb vapor cell, we achieve -3 dB of vacuum squeezing within the noise spectral window of 100 Hz to several MHz, corresponding to 3.5 dB squeezing when accounting for optical losses. Leveraging this level of squeezing, we demonstrate a magnetic field sensitivity of approx. 1 pT/Hz. The combination of vacuum-squeezed light and micrometer-scale vapor cells paves the way for compact, low-power-consumption atomic sensors with enhanced performance.
We report a rubidium atomic magnetometer based on pump-probe nonlinear magneto-optical rotation. The rubidium vapor cell is placed in a five-layer magnetic shield with inner coils that can generate uniform magnetic fields along the direction of pump beam, and the cell is also placed in the center of a Helmholtz coil that can generate an oscillating magnetic field perpendicular to the direction of pump beam. The atoms are optically pumped by circularly polarized pump beam along a constant magnetic field in a period of time, then the pump beam is turned off and a /2 pulse of oscillating magnetic field for 87Rb atoms is applied. After the above process, the individual atomic magnetic moments become phase coherent, resulting in a transverse magnetization vector precessing at the Larmor frequency in the magnetic field. The linearly polarized probing beam is perpendicular to the direction of magnetic field, and can be seen as a superposition of the left and right circularly polarized light. Because of the different absorptions and dispersions of the left and right circularly polarized light by rubidium atoms, the polarization direction of probing beam rotates when probing beam passes through rubidium vapor cell. The rotation of the polarization is subsequently converted into an electric signal through a polarizing beam splitter. Finally, the decay signal related to the transverse magnetization vector is measured. The Larmor frequency proportional to magnetic field is obtained by the Fourier transform of the decay signal. The value of magnetic field is calculated from the formula:B=(2/) f, where and f are the gyromagnetic ratio and Larmor frequency, respectively. In order to measure the magnetic field in a wide range, the tracking lock mode is proposed and tested. The atomic magnetometer can track the magnetic field jump of 1000 nT or 10000 nT, indicating that the atomic magnetometer has strong locking ability and can be easily locked after start-up. The main performances in different magnetic fields are tested. The results show that the measurement range of the atomic magnetometer is from 100 nT to 100000 nT, the extreme sensitivity is 0.2 pT/Hz1/2, and the magnetic field resolution is 0.1 pT. The transverse relaxation times of the transverse magnetization vector in different magnetic fields are obtained, and the relaxation time decreases with the increase of the magnetic field. When the measurement range is from 5000 nT to 100000 nT, the magnetic field sampling rate of the atomic magnetometer can be adjusted in a range from 1 Hz to 1000 Hz. The atomic magnetometer in high sampling rate can measure weak alternating magnetic field at low frequency. This paper provides an important reference for developing the atomic magnetometer with large measurement range, high sensitivity and high sampling rate.
(English) This thesis describes experiments that employ squeezed light to improve the performance of a sensitive optically-pumped magnetometer (OPM). The squeezed light source employs parametric amplification of vacuum fluctuations to produce squeezed vacuum and polarization-squeezed light tunable around the Rb D1 line. The OPM employs Bell-Bloom optical pumping of a high density vapor (with atom number density 10^{13}) and paramagnetic Faraday rotation, also on the Rb D1 line. The setup allows convenient switching from probing with laser light to probing with polarization-squeezed light, to study the use of the latter in atomic magnetometry. The magnetometer shows sub-pT/Hz^{1/2} sensitivity, limited by quantum noise; spin projection noise at low frequencies (<100Hz) and photon shot noise at high frequencies. Probing with polarization squeezed light suppresses the photon shot noise by 2dB, limited by the available squeezing and optical losses in passing through the vapor. This shot-noise suppression improves the high-frequency sensitivity and increases the measurement bandwidth, with no observed loss of sensitivity at any frequency. This result confirms experimentally the expected evasion of measurement back-action noise in the Bell-Bloom magnetometer. The thesis also develops a physical model to explain the observed spin dynamics of the Bell-Bloom magnetometer. The model describes the combined spin and optical polarization dynamics using Bloch equations with stochastic drive and detection noise terms. A perturbative approach and Fourier methods are then used to obtain analytic expressions for the magnetometer's frequency response, spin projection noise and photon shot noise. The role of measurement back-action emerges from a study of this model. As polarization squeezing reduces optical noise in the detected Stokes parameter, the accompanying ellipticity anti-squeezing is shunted into the unmeasured spin component. The thesis also reports a study of squeezed-light-enhanced magnetometry at a range of atomic densities, from 2.18 10^{12} atoms/cm3 to 1.13 10^{13} atoms/cm3 . Operating with fixed conditions of optical pumping, the signal amplitude, instrument noise spectrum and magnetic resonance width are measured as a function of atomic number density, for both laser- and squeezed-light probing. The equivalent magnetic noise spectra are then calculated. In the photon-shot-noise-limited portion of the spectrum, the squeezed light probing improves the magnetometer's sensitivity and measurement bandwidth for the full range of atomic density values. In particular, the laser-probed magnetometer shows a sensitivity optimum at n ~ 6 10 ^{12} atoms/cm3, and the squeezed-light-probed magnetometer surpasses this sensitivity. The thesis concludes with a discussion of the potential of stronger optical squeezing to enhance the instrument's sensitivity in different portions of the spectrum. Using the theory model we estimate the enhancement of the equivalent magnetic noise spectrum for 2 dB , 5.6 dB and perfect squeezing (zero noise in the detected polarization component) at the input to the atomic medium. (Català) Aqueta tesi descriu la millora d’un magnetòmetre de bombeig òptic (OPM) mitjançant l’ús d’estats de llum amb incertesa comprimida (squeezed states). S’usa amplificació paramètrica per a comprimir la incertesa de la font de llum. En concret, es comprimeix la incertesa de l’estat de buit quàntic, com també de la polarització òptica, amb la possibilitar d’ajustar la longitud d’ona al voltant de la transició atòmica D1 de 87Rb. L’OPM usa bombeig òptic Bell-Bloom de vapors d’alta densitat (amb densitats atòmiques properes a 1013) i rotació de Faraday, també al voltant de la transició atòmica D1 de 87Rb. L’aparell experimental permet canviar de mostreig amb llum coherent làser a mostreig amb llum de polarització comprimida, amb la finalitat d’avaluar el seu impacte en la sensitivitat del magnetòmetre. El magnetòmetre té una sensitivitat de sub-pT{ ?Hz , principalment limitada per soroll quàntic; soroll de projecció de spin a baixes freqüències (À 100 Hz) i soroll de quantització fotònica a altes freqüències. L’ús d’estats de llum amb polarització comprimida permet reduir el soroll fotònic en „ 2 dB, limitat per la compressió disponible i les pèrdues en travessar el vapor atòmic. La supressió del soroll fotònic augmenta l’amplada de banda del sistema amb l’avantatge de no perdre sensitivitat a cap banda de freqüència. Els resultats experimentals confirmen l’esperada supressió de retroalimentació de soroll en magnetòmetres de Bell-Bloom. La tesi també estudia el model teòric darrere les dinàmiques de spin en un magnetòmetre de tipus Bell-Bloom. El model descriu la combinació de les dinàmiques de spin i de la polarització òptica mitjançant equacions de Bloch forcades estocàsticament i amb termes de soroll de detecció. Es treballa en el límit pertorbatiu on mitjançant mètodes de Fourier s’obtenen expressions analítiques de la resposta en freqüència del magnetòmetre, dels sorolls de projecció de spin i del soroll de quantització fotònica. El rol de la retroalimentació de soroll també s’extrau d’aquest model. En concret, s’observa que la compressió en polarització redueix el soroll en els paràmetres de Stokes detectats, mentre els paràmetres de spin no mesurats experimenten una expansió de la seva incertesa (anti-squeezing). La tesi estudia magnetòmetres òptics de llum amb incertesa comprimida per a densitats entre 2.18 ˆ 1012 atoms{cm3 i 1.13 ˆ 1013 atoms{cm3. Es mesuren l’amplitud de senyal, l’espectre de soroll i l’amplada de la ressonància magnètica en funció de la densitat atòmica, per a un bombeig òptic constant i per a ambdós tipus de mostreig òptic (llum coherent i llum de polarització comprimida). A continuació, es calculen els espectres de soroll equivalents. En la part d’espectre on domina el soroll de quantització fotònica, s’observa que l’ús de llum de polarització comprimida millora la sensitivitat del magnetòmetre al llarg de tot el rang de densitats atòmics. En concret, la sensitivitat del magnetòmetre amb mostreig coherent és òptima per a n « 6ˆ1012 atoms{cm3 i es demostra una millora amb l’ús de mostreig amb llum comprimida. Es conclou amb una discussió sobre l’efecte de compressions més severes en la sensitivitat del magnetòmetre. Mitjançant el model teòric s’estima la millora en la sensitivitat per a compressions de 2 dB, 5.6 dB i “compressió perfecta” a l’entrada del medi atòmic
Squeezed states are important sources in quantum physics, which have potential applications in fields such as quantum teleportation, quantum information networks, quantum memory, and quantum metrology and precise measurements. For our interest, the squeezed vacuum will be used in the quantum-enhanced optical atomic magnetometers, filling the vacuum port of the probe beam to improve measurement sensitivity. Based on the sub-threshold optical parametric oscillator (OPO) with PPKTP crystal, the squeezed vacuum at rubidium D1 line of 795 nm is obtained. In our work, we investigate the noise sources in an OPO system. By carefully controlling the classical noise source, the squeezing band extends to the analysis frequency of 2.6 kHz. The flat squeezing trace is 2.8 dB below the shot noise limit. In our work, we focus on the difference between the squeezing results at the analysis frequency of kilohertz regime at two different wavelengths, 1064 nm and 795 nm. The difference mainly comes from the absorption of 795 nm laser and its second harmonic at 397.5 nm in crystal (397.5 nm laser is at the edge of transparent window of PPKTP crystal that has an absorption index much higher than at other wavelength). The absorption induced nonlinear loss and thermal instability greatly affect the squeezing results, which is discussed in our work. Squeezing level at 795 nm is worse than at 1064 nm due to the above-mentioned factors. Noise coupling to the detection system limits the squeezing band. In the audio frequency band, squeezing is easily submerged in roll-up noises and the measured squeezing level is limited. Two factors limit the obtained squeezing:the technical noise induced in the detection and the squeezing degradation by the noise coupling of the control beams. In experiment, we carefully control the classical noise at analytical frequency of kilohertz by means of a vacuum-injected OPO, a counter-propagating cavity locking beam with orthogonal polarization, low noise homodyne detector, stable experimental system and quantum noise locking method for squeezing phase locking. Firstly, to preclude the classical noise from coupling the laser source, we use the vacuum injected OPO. A signal beam helps optimize the parametric gain and is blocked in the squeezing measurement process. In order to maintain the OPO, a counter-propagating beam with orthogonal polarization is used for locking the cavity. Then, a low noise balanced homodyne detector with a common-mode rejection ratio of 45 dB helps improve the audio frequency detection. Finally, the quantum noise locking provides a method to lock the relative phase between the coherent beam and the squeezed vacuum field. With the combination of these technical improvements, a squeezed vacuum of 2.8 dB is obtained at the analysis frequency of 2.6-100 kHz. The obtained squeezing level is mainly limited by the relatively large loss in OPO, which is induced by ultra-violet absorption in PPKTP crystal. The generated squeezed field is used to reduce the polarization noise of probe beam in an optical magnetometer, in order to increase detection sensitivity.
Nonclassical states of light are of increasing interest due to their applications in the emerging field of quantum information processing and communication. Squeezed light is such a state of the electromagnetic field in which the quantum noise properties are altered compared with those of coherent light. Squeezed light and squeezed vacuum states are potentially useful for quantum information protocols as well as optical measurements, where sensitivities can be limited by quantum noise. We experimentally study a source of squeezed vacuum resulting from the interaction of near-resonant light with both cold and hot Rb atoms via the nonlinear polarization self-rotation effect (PSR). We investigate the optimal conditions for noise reduction in the resulting squeezed states, reaching quadrature squeezing levels of up to 2.6 dB below shot noise, as well as observing noise reduction for a broad range of detection frequencies, from tens of kHz to several MHz. We use this source of squeezed vacuum at 795 nm to further study the noise properties of these states and how they are affected by resonant atomic interactions. This includes the use of a squeezed light probe to give a quantum enhancement to an optical magnetometer, as well as studying the propagation of squeezed vacuum in an atomic medium under conditions of electromagnetically induced transparency (EIT). We also investigate the propagation of pulses of quantum squeezed light through a dispersive atomic medium, where we examine the possibilities for quantum noise signals traveling at subluminal and superluminal velocities. The interaction of squeezed light with resonant atomic vapors finds various potential applications in both quantum measurements and continuous variable quantum memories.