Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Laser Physics

Electromagnetically induced transparency with magnetically induced Δ F = 0 , m F = 0 → m F = 0 probe transition

Armen D. Sargsyan, David G. Sarkisyan, A. Papoyan

Published Jul 3, 2024• 2 citations
Publisher

Abstract

Abstract Interest in magnetically induced (MI) transitions of alkali metal atoms is caused by the fact that their intensities can exceed the intensities of ‘regular’ atomic transitions in a wide magnetic field range (200–4000 G). The goal of this work was to form and study, for the first time, electromagnetically induced transparency (EIT) resonance in a strong magnetic field using probe radiation tuned to | F g = F , m F = 0 ⟩ → | F e = F , m F = 0 ⟩ MI transition, which is forbidden in zero magnetic fields. Two narrow-band linearly polarized cw diode lasers were used to form EIT resonance on a Λ-type system of a Cs atomic D 2 line in a strong transverse magnetic field (up to 1000 G). The resonance was formed in a Cs atomic vapor nanocell with an atomic vapor column thickness of 850 nm.

DOI
10.1088/1555-6611/ad5157

Related papers

Resonance of Electromagnetically Induced Transparency in the Selective Reflection Signal of Atomic Cs Vapor

Armen D. Sargsyan, D. E. Bostanjyan, David G. Sarkisyan

Abstract The process of electromagnetically induced transparency (EIT) was investigated using two different probe radiations in Cs atomic vapor: in the first case probe radiation– transmission through a nanocell (NC) with the formation of EITT; in the second–selective reflection (SR) of laser radiation from the boundary of the atom-dielectric vapor (dielectric is nanocell window) with the formation of EITSR. To form EIT resonances, we used two continuous narrow-band lasers with λ = 852 nm and a nanocell with an atomic vapor column thickness in the range of 150–1500 nm. A comparison of the formation of EIT resonance in the first and second cases was carried out. Probe radiation containing EITT and EITSR-resonances propagates in opposite directions. It is noted that in a few cases, the formation of EIT resonance is more effective using SR radiation. The splitting of the EITSR-resonance in the longitudinal magnetic field into seven equidistant components was recorded, which allows remote monitoring of the magnetic field.

Journal of Contemporary Physics (Armenian Academy of Sciences)•Mar 1, 2025•2 citations

Electromagnetically induced transparency resonances inverted in magnetic field

Armen D. Sargsyan, David G. Sarkisyan, Y. Pashayan-Leroy +4 more

The phenomenon of electromagnetically induced transparency (EIT) is investigated in a Λ-system of the 87Rb D 1 line in an external transverse magnetic field. Two spectroscopic cells having strongly different values of the relaxation rates γrel are used: an Rb cell with antirelaxation coating (L ~ 1 cm) and an Rb nanometric- thin cell (nanocell) with a thickness of the atomic vapor column L = 795 nm. For the EIT in the nanocell, we have the usual EIT resonances characterized by a reduction in the absorption (dark resonance (DR)), whereas for the EIT in the Rb cell with an antirelaxation coating, the resonances demonstrate an increase in the absorption (bright resonances (BR)). We suppose that such an unusual behavior of the EIT resonances (i.e., the reversal of the sign from DR to BR) is caused by the influence of an alignment process. The influence of alignment strongly depends on the configuration of the coupling and probe frequencies as well as on the configuration of the magnetic field.

arXiv:1505.03856•Journal of Experimental and Theoretical Physics•Dec 1, 2015•15 citations

High-contrast dark resonances on the D1 line in cesium nanocell: the advantages compared with the other alkali D lines

Armen D. Sargsyan, Claude Leroy, Y. Pashayan-Leroy +2 more

Electromagnetically induced transparency (EIT) effect in a -system formed by Cs atoms line, enclosed in nanometric-thin cells, is studied both experimentally and theoretically for the first time. The atomic column thickness varies in the range of 50–1500 nm. It is demonstrated that when the coupling laser frequency is in exact resonance with the corresponding atomic transition, the parameters of the EIT resonance (also called dark resonance (DR)) depend weakly on , which allows us to detect DR at nm with the contrast of . The obtained DR parameters are the best as compared with those for Rb and lines and Cs line. The DR contrast and width are studied versus laser frequency detunings, coupling laser power, cell thickness, temperature, and applied external magnetic field. The well-resolved splitting of the DR resonance in a magnetic field for nm can be used for magnetometry with high spatial resolution. The theoretical model describes well the observed results.

Journal of Modern Optics•Feb 10, 2015•15 citations

Dark resonance formation with magnetically induced transitions: extension of spectral range and giant circular dichroism

Armen D. Sargsyan, A. Tonoyan, A. Papoyan +1 more

Dark resonances were formed via electromagnetically induced transparency for the first time, to the best of our knowledge, involving magnetically induced ΔF=±2 atomic transitions of alkali metal atoms, which are forbidden at zero magnetic field. The probability of these transitions undergoes rapid growth when 300–3000 G magnetic field is applied, allowing formation of dark resonances, widely tunable in the GHz range. It is established that for ΔF=+2 (ΔF=−2) transition, the coupling laser tuned to ΔF=+1 (ΔF=−1) transition of the hyperfine Λ-system must be σ+ (σ−) polarized, manifesting anomalous circular dichroism.

arXiv:1901.09226•Optics Letters•Mar 8, 2019•22 citations

The effect of electromagnetically induced transparency in a potassium nanocell

Armen D. Sargsyan, A. Amiryan, Claude Leroy +2 more

The effect of electromagnetically induced transparency (EIT) has been experimentally implemented for the first time for the (4S 1/2–4P 1/2–4S 1/2) Λ-system of potassium atom levels in a nanocell with a 770-nm-thick column of atomic vapor. It is shown that, at such a small thickness of the vapor column, the EIT resonance can be observed only when the coupling-laser frequency is in exact resonance with the frequency of the corresponding atomic transition. The EIT resonance disappears even if the coupling-laser frequency differs slightly (by ~50 MHz) from that of the corresponding atomic transition, which is due to the high thermal velocity of K atoms. The EIT resonance and related velocity selective optical pumping resonances caused by optical pumping (formed by the coupling) can be simultaneously recorded because of the small (~462 MHz) hyperfine splitting of the lower 4S 1/2 level.

Optics and Spectroscopy•Jul 1, 2017•12 citations

Application of Magnetically Induced Transitions of the 85Rb D2 Line in Coherent Processes

Armen D. Sargsyan, A. Tonoyan, David G. Sarkisyan

Abstract Magnetically induced Fg = 2 → Fe = 4 transitions corresponding to the 85Rb D2 line in the case of the σ+ circularly polarized radiation have been used for the first time to form optical dark resonances in strong magnetic fields up to 1 kG under electromagnetically induced transparency conditions. A 1.5-μm-thick cell filled with Rb atomic vapor has been used. The probabilities of two of five magnetically induced transitions, which are efficiently formed only with the σ+-polarized radiation, in the magnetic field range of 0.2–1 kG exceed the probabilities of “ordinary” atomic transitions. For this reason, it is appropriate to use them in Λ systems for the formation of the dark resonance. The following rule has been established: for the formation of the dark resonance in a Λ system with the use of the σ+-polarized probe radiation at the frequencies of magnetically induced transitions, the radiation of the coupling laser should also be σ+ polarized; the dark resonance is not formed if the radiation of the coupling laser is σ– polarized, which is confirmed by the calculated theoretical curve. A significant advantage of magnetically induced resonances for electromagnetically induced transparency compared to ordinary atomic transitions corresponding to the 85Rb D2 line has been demonstrated. The formation of dark resonances in strong magnetic fields, when their frequency is shifted by several gigahertzs, can be applied in practice.

Journal of Experimental and Theoretical Physics•Jul 1, 2021•5 citations
Abstract Interest in magnetically induced (MI) transitions of alkali metal atoms is caused by the fact that their intensities can exceed the intensities of ‘regular’ atomic transitions in a wide magnetic field range (200–4000 G). The goal of this work was to form and study, for the first time, electromagnetically induced transparency (EIT) resonance in a strong magnetic field using probe radiation tuned to | F g = F , m F = 0 ⟩ → | F e = F , m F = 0 ⟩ MI transition, which is forbidden in zero magnetic fields. Two narrow-band linearly polarized cw diode lasers were used to form EIT resonance on a Λ-type system of a Cs atomic D 2 line in a strong transverse magnetic field (up to 1000 G). The resonance was formed in a Cs atomic vapor nanocell with an atomic vapor column thickness of 850 nm.
Abstract The process of electromagnetically induced transparency (EIT) was investigated using two different probe radiations in Cs atomic vapor: in the first case probe radiation– transmission through a nanocell (NC) with the formation of EITT; in the second–selective reflection (SR) of laser radiation from the boundary of the atom-dielectric vapor (dielectric is nanocell window) with the formation of EITSR. To form EIT resonances, we used two continuous narrow-band lasers with λ = 852 nm and a nanocell with an atomic vapor column thickness in the range of 150–1500 nm. A comparison of the formation of EIT resonance in the first and second cases was carried out. Probe radiation containing EITT and EITSR-resonances propagates in opposite directions. It is noted that in a few cases, the formation of EIT resonance is more effective using SR radiation. The splitting of the EITSR-resonance in the longitudinal magnetic field into seven equidistant components was recorded, which allows remote monitoring of the magnetic field.
The phenomenon of electromagnetically induced transparency (EIT) is investigated in a Λ-system of the 87Rb D 1 line in an external transverse magnetic field. Two spectroscopic cells having strongly different values of the relaxation rates γrel are used: an Rb cell with antirelaxation coating (L ~ 1 cm) and an Rb nanometric- thin cell (nanocell) with a thickness of the atomic vapor column L = 795 nm. For the EIT in the nanocell, we have the usual EIT resonances characterized by a reduction in the absorption (dark resonance (DR)), whereas for the EIT in the Rb cell with an antirelaxation coating, the resonances demonstrate an increase in the absorption (bright resonances (BR)). We suppose that such an unusual behavior of the EIT resonances (i.e., the reversal of the sign from DR to BR) is caused by the influence of an alignment process. The influence of alignment strongly depends on the configuration of the coupling and probe frequencies as well as on the configuration of the magnetic field.
Electromagnetically induced transparency (EIT) effect in a -system formed by Cs atoms line, enclosed in nanometric-thin cells, is studied both experimentally and theoretically for the first time. The atomic column thickness varies in the range of 50–1500 nm. It is demonstrated that when the coupling laser frequency is in exact resonance with the corresponding atomic transition, the parameters of the EIT resonance (also called dark resonance (DR)) depend weakly on , which allows us to detect DR at nm with the contrast of . The obtained DR parameters are the best as compared with those for Rb and lines and Cs line. The DR contrast and width are studied versus laser frequency detunings, coupling laser power, cell thickness, temperature, and applied external magnetic field. The well-resolved splitting of the DR resonance in a magnetic field for nm can be used for magnetometry with high spatial resolution. The theoretical model describes well the observed results.
Dark resonances were formed via electromagnetically induced transparency for the first time, to the best of our knowledge, involving magnetically induced ΔF=±2 atomic transitions of alkali metal atoms, which are forbidden at zero magnetic field. The probability of these transitions undergoes rapid growth when 300–3000 G magnetic field is applied, allowing formation of dark resonances, widely tunable in the GHz range. It is established that for ΔF=+2 (ΔF=−2) transition, the coupling laser tuned to ΔF=+1 (ΔF=−1) transition of the hyperfine Λ-system must be σ+ (σ−) polarized, manifesting anomalous circular dichroism.
The effect of electromagnetically induced transparency (EIT) has been experimentally implemented for the first time for the (4S 1/2–4P 1/2–4S 1/2) Λ-system of potassium atom levels in a nanocell with a 770-nm-thick column of atomic vapor. It is shown that, at such a small thickness of the vapor column, the EIT resonance can be observed only when the coupling-laser frequency is in exact resonance with the frequency of the corresponding atomic transition. The EIT resonance disappears even if the coupling-laser frequency differs slightly (by ~50 MHz) from that of the corresponding atomic transition, which is due to the high thermal velocity of K atoms. The EIT resonance and related velocity selective optical pumping resonances caused by optical pumping (formed by the coupling) can be simultaneously recorded because of the small (~462 MHz) hyperfine splitting of the lower 4S 1/2 level.
Abstract Magnetically induced Fg = 2 → Fe = 4 transitions corresponding to the 85Rb D2 line in the case of the σ+ circularly polarized radiation have been used for the first time to form optical dark resonances in strong magnetic fields up to 1 kG under electromagnetically induced transparency conditions. A 1.5-μm-thick cell filled with Rb atomic vapor has been used. The probabilities of two of five magnetically induced transitions, which are efficiently formed only with the σ+-polarized radiation, in the magnetic field range of 0.2–1 kG exceed the probabilities of “ordinary” atomic transitions. For this reason, it is appropriate to use them in Λ systems for the formation of the dark resonance. The following rule has been established: for the formation of the dark resonance in a Λ system with the use of the σ+-polarized probe radiation at the frequencies of magnetically induced transitions, the radiation of the coupling laser should also be σ+ polarized; the dark resonance is not formed if the radiation of the coupling laser is σ– polarized, which is confirmed by the calculated theoretical curve. A significant advantage of magnetically induced resonances for electromagnetically induced transparency compared to ordinary atomic transitions corresponding to the 85Rb D2 line has been demonstrated. The formation of dark resonances in strong magnetic fields, when their frequency is shifted by several gigahertzs, can be applied in practice.